SEIH5KP1, SEIH6KP1 Installation Manual. Issue STROM- ELECTRICAL.

Similar documents
SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

SF15K SF05KSS, SF10KSS

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

INSTALLATION & TECHNICAL MANUAL

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

High kw Electric Tankless Water Heater Troubleshooting Guide

3 IN 1 BATHROOM HEATER

Operators manual Basic water heater

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Electronically Controlled Instantaneous Water Heaters Models: DEX & DBX

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION

Assembly and instructions

SELECTION, APPLICATION AND MAINTENANCE

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF)

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

OWNER S MANUAL & INSTALLATION GUIDE. Installation Details Owner s Information Warranty. 80L - 400L Electric Storage Water Heaters

Electric Instantaneous. Water Heaters. Service manual

Oil and Coolant Circulating Heating System. Model - OCSM

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

Owner s Manual. Installation Details Owner s Information. 80L to 400L Electric Storage Water Heaters

Elson Coral E. Open Vented Thermal Store providing mains pressure hot water heated by electricity. Installation, Servicing and User's Instructions

I N S T ALLATION INSTRUCTIONS & HOME OWNERS MANUAL IMPORTANT SAFETY INFORMATION

Installation and User Instructions Aquaheat Unvented Water Heaters Models: AH7/2.2, AH10/2.2, AH15/2.2

INFRARED QUARTZ WALL HEATER

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

Troubleshoot resources for homeowner

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting

Guidance Notes For Provision Of Water Expansion For 10 & 15 Litre Unvented Hot Water Heaters

Shower Handbook (Also covers 650 chrome variant)

STAINLESS STEEL TANK TABLE OF CONTENTS TROUBLESHOOTING... 1 TESTING WATER TEMPERATURE... 3 TANK & JACKET ASSEMBLY... 4.

Aquamax Australia Pty Ltd ABN

12 Volt 30 Amp Digital Solar Charge Controller

CTV-1500 Cooling Tower Vacuum Operating & Maintenance Manual

ELECTRIC CENTRAL HEATING FLOW BOILER

GeyserWise TSE. thermostat instruction manual. SANS 181 compliant

SunMaxx Solar Filling Station Operating Instructions

Baxi Combi 80e & 105e

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

Please also see 10 golden rules for correct Saniflo installation on

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

COMPRESSED AIR DRYER

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

SERVICE MANUAL Order No.WH0911S001V0

Ceiling Mount Air Handler Manual

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

User's Instructions. Alpha HE CB25/33 and HE SY25

INSTRUCTION MANUAL A REVISION A. Series E1 and E3 Instant Hot Water Recirculating Systems

Baxi Combi Instant 80e & 105e. User s Operating Instructions. Gas Fired Wall Mounted Combination Boiler

Electric Flow Boiler

ALL IN ONE. Heat Pump Water Heater

SERVICE MANUAL RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS. Troubleshooting Guide and Instructions for Service

Overheating limit control

INSTALLATION INSTRUCTIONS AND HOMEOWNER MANUAL

Calor de Hogar. Av Tecnológico 735, PB. San Salvador Tizatlalli. Metepec, 52172, Edo de México. Teléfono (722) (55)

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

Troubleshooting Salt Generators

CARING FOR YOUR WATER HEATER

Electric Flow Boiler

Triac Printed Circuit Board Replacement

SERIES VOLT ELECTRIC INSTANTANEOUS WATER HEATER FOR EMERGENCY SAFTEY EQUIPMENT INSTALLATION AND OWNERS MANUAL REQUIRED MANTENANCE

Elson 10/15L Unvented Water Heater

Owner & Installation Manual

STEAM HEATING SYSTEM TROUBLESHOOTING GUIDE

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

Float and Thermostatic Traps Series H, C and X

ELECTRIC INSTANTANEOUS WATER HEATER

Design Utility Lever Thermostatic Bath Shower Mixer

Reverse Cycle Inverter Split System Air Conditioner

For installation guide see reverse of book

Isotemp Basic, Slim/B & Slim Square

Trouble Shooting. Pump

MODEL INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS & OWNERS GUIDE

MANUAL. * Supply plugs may differ to suit your wall socket. EN 3. Continue to press the MODE-button to combine charging program with charging options.

Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.

REDRING POWERSTREAM-ECO UNVENTED INSTANTANEOUS WATER HEATER. Installation and User Guide

Neuton Solar Power Diverter Quick Installation Guide

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

1/3 HP Submersible Sump Pump with Vertical Float Switch

MAC FAUCETS. Owner s Manual. Models: FA444

Table Z. Troubleshooting Chart for Air Conditioners. Cause

KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119

INSTALLATION INSTRUCTIONS FOR MODELS 16NG50/16LP50, 16NG60/16LP60, 20NG50/20LP50, 20NG60/20LP60, 26NG50/26LP50, 26NG60/26LP60

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

OPL BASIC. Dosing System for Professional Laundry machines. Contents

WE-350 Series ¼ Turn Electric Actuator

Electric Water Heater

Installation and Operating Instruction Manual

Troubleshooting Guide for Dispenser Model #900172

I N S T A L L A T I O N I N S T R U C T I O N S F O R T H E H i l k o i l Energy S aving Hot Water Kit

PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

STABITHERM INSTALLATION & SERVICE BOOKLET

Transcription:

SEIH5KP1, SEIH6KP1 Installation Manual Issue 1 2015 STROM- ELECTRICAL www.strom-electrical.com

INTRODUCTION Thank you for purchasing your Strom-Electrical instaneous water heater, we are very proud of our products and we are sure that you will be happy with the years of service you get from your model. This product has been designed to operate at mains pressure and deliver instant hot water. SPECIFICATION MODEL SEIH5KP1 SEIH6KP1 Body Material High Strength ABS Casing Voltage 220-240v Rated Frequency 50-60Hz Power 5.5kW 6.8kW Rated Current 24A 29.6A Supplied Cable Size 2.5mm 2 4.0mm 2 Overheat Protection 67 o C Thermal Cut-Out 90 o C Control Mode Digitally Controlled Thermostat Temperature Range 30 o C - 55 o C Water Connections G1/2 Working Pressure 0.02-0.6mPa IMPORTANT NOTICE For your satisfaction and safety, read all instructions before installing or using this instant hot water heater. This appliance should be connected to a public mains water feed. This water heater may not be suitable for children or some elderly operators unattended due to the risk of scalding should the unit be incorrectly operated. Your Strom-Electrical water heater MUST be installed and maintained regularly by a qualified

professional in accordance with current electrical and plumbing regulations. If the chloride content exceeds 200ppm a filtration system should be fitted, failure to do so may invalidate your warrenty. This device has been designed for internal use only, if the system may be exposed to frost please drain down the system completely, and DO NOT attempt to use the device if you suspect it is frozen. Always ensure that the flow temperature is not excessive before use. If the water is too hot please increase the flow at the tap and wait for the temperature to reduce. As part of the product maintenance regularly clean the filter washer provided at the heater, failure to do so may reduce your flow rate over time. The heater is not designed for modification in any way, please do not fit anything to the unit unless otherwise recommended. When comissioning the water valve should be adjusted to increase or decrease the water flow to the unit, this in turn will control the temperature of water from the unit, slower increases the temperature, faster decreases the temperature. Each unit is tested at our factory before its departure, a little residual water is normal, and the product should be flushed through before use. Never try to operate this device if your water supply is blocked or turned off, doing so could cause premature failure of your device. Any damage to the wiring or integrity of your device should be assessed by a qualified electrician, and the device should not be used until the unit or wiring has been repaired. The minimum water supply available at the point of install is 0.02mPa. The unit must be installed in a vertical position with the connections facing downwards and should not be installed in an area with high magnetic interference. BEFORE INSTALLATION This installation must only be carried out by qualified professionals and installed to all relevent national and local electrical and plumbing regulations. Failure to do this could render the install both illegal and dangerous. Before installation please ensure the following: 1. Your Strom-Electrical appliance is intact, and the fittings are supplied & complete. 2. Please make sure the mains power supply, water pressure, earthing condition, and cabling reach the standards required for installation as required by all relevent regulations & laws. 3. The appliance must be properly earthed in accordance with all current regulations and laws. 4. If the unit is not to be used for a prolonged period of time please drain down and isolate the electrical supply of the product. 5. Position the unit upright with all plumbing connections at the bottom of the unit. 6. During the installation please test water flow is achieved at the tap before connecting the power supply. If the heater is activated without water supply the unit may be damaged. 7. This water heater may cause a small amount of water expansion due to residual heat after operation. In most systems this is easily accommodated by the distribution pipework and water supply system. In instances where problems may occur such as the existence of upstream non return valves close to the heater then it is recommended that a small shock arrestor/expansion vessel is fitted.

PRODUCT STRUCTURE Control Board Terminal Blocks Cable Clamp Thermal Cut-Out & Reset Triac Display Board Heating Chamber Temperature Sensor Flow Meter Hot Outlet Cold Inlet WIRING SCHEMATIC This diagram is provided for your reference of the internal wiring of your Strom-Electrical water heating product. No attempt should be made to change the internals of your water heater, doing so may be dangerous and will invalidate your warranty. Your product MUST always be wired by a qualified electrician in accordance with all the relevent regulations and laws in place at the time of installation.

PRODUCT MOUNTING Please remove the hanger bracket from the back of the water heater, and position on the wall in the orientation shown below. Drill three 6.00mm holes in accordance with the hanger bracket, these holes should be 100mm apart as shown below. Using wall plugs and suitably long screws secure the hanger bracket to the wall. Once the hanger bracket is installed and secure the heater unit can be mounted to the bracket. INSTALLATION Once your product has been sited in accordance with the diagrams above please connect your product to the mains water supply using a 1/2 tap hose to the blue connection of the unit, NOTE: a check valve should be fitted before your electrical water heater. Fit the supplied filter between the unit and the hose. We suggest fitting an isolation valve and ball valve before the unit to facilitate removal of the tap and servicing. Once the cold mains has been fitted you may use another 1/2 tap hose to connect your heater to the properties hot pipework circuit (this circuit could be 1 outlet or multiple outlets, please ensure your unit is capable of heating the number of outlets you are asking it to). REMEMBER: Before turning off the water supply to the unit you must isolate its electric supply, operating the unit while there is no water can cause premature failure and invalidate your warrenty. DO NOT turn on your electric supply at this time.

COMISSIONING 1. Please flush the system through completely by opening the hot tap on the water heater circuit furthest away from the heater. Allow all air, and debris to pass before closing the hot tap. 2. Turn on the power supply to the heater. 3. Using the button please turn the heater up to 45 o C. 4. When set, open as many hot outlets as likely to be used at once on the circuit, and adjust the ball valve until the temperature output at the taps matches that on the display of the unit. Increase or decrease the flow until just before the temperature drops, increasing the flow will make the target harder to achieve, decreasing the flow makes it easier to achieve. 5. This optimises the flow rate for 45 o C, if you wish to optimise for a different temperature, please set the device at the required temperature and repeat step 4. REMEMBER: Adjusting the flow to the unit up or down controls the flow at the tap which makes it easier or harder to achieve the set temperature. This may require some balancing to achieve the best results for your scenario. 6. The comissioning of your system is now complete. GENERAL USE Operation of this unit is simple: The heater automatically detects flow, so as soon as a tap is opened the heater will instantly begin to heat the flow of water in accordance with the settings provided to the heater. To control the output temperature of the heater use and buttons to set the target temperature. The LED display will show you the target temperature that has been set on the device. TOP TIP: If the unit is installed in a cupboard once the temperature has been set the cupboard can be locked, this prevents the temperature from being changed and makes the product safer for children. MAINTENANCE Always turn off the power supply before servicing your unit To ensure a long lasting and efficient product we recommend the following maintenance regime: The filter washer supplied and fitted should be cleaned to reduce any debris build up and ensure good consistent flow rates.

TROUBLESHOOTING SYSTEM ISSUE LIKELY CAUSE POSSIBLE SOLUTION Inlet or Outlet are leaking Fittings not tight enough Tighten the fittings Rubber seals have worn out Replace rubber seals There is no LED display The power supply is not live Get electrician to check supply LED Screen is damaged Have the LED Screen replaced Function keys not working There is no water flow Open a tap to allow flow Water is too hot Water is too cold Outlet flow rate is getting slower Water pressure is too low Key or PCB is damaged Temperature is set too high The water flow is too slow Temperature is set too low The water flow is too fast Inlet strainer is clogged Increase water pressure Replace the PCB Using the function keys reduce the target temperature Increase the flow to the unit Using the function keys increase the target temperature Reduce the flow to the unit Clean the filter washer out LED display shows E1 Outlet temperature is over 67 o C Reduce the set temperature Increase the water flow rate LED display shows E2 There is electricity leakage Please contact your electrician LED display shows E3 Temperature Sensor Failure Please contact Strom-Electrical GUARANTEE Your Strom-Electrical water heater is guaranteed for a period of 12 months from the date of purchase. The unit is only guaranteed if the water heater has been installed and maintained in accordance with these instructions. Full guarantee information can be found at: www.strom-electrical.com/guarantee The guarantee specifically excludes: Corrosion by incorrect maintenance of the water heater, or incorrect installation. Limscale build up. Consequential losses, including labour charges and damages to fittings. Any water heater that has not been maintained and installed in accordance with this manual.

www.strom-electrical.com STROM- ELECTRICAL www.strom-electrical.com