FUNDAMENTAL PRINCIPLES OF DIAPHRAGM METERS. Robert Bennett American Meter Company

Similar documents
Fundamental Principles of Rotary Displacement Meters

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

TYPE E Main Valve Sizes 3 /8 through 12

INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS

MODEL LP 225LP2 225LP4 Safety Relief Valves

Example. Fluid Power. Circuits

Float and Thermostatic Traps Series H, C and X

CYLINDER LEAKAGE CHECK (Compression)

AWWA Butterfly Valve Operation and Maintenance Manual Series 511A & 510A 20 and Smaller

PRESSURE REDUCING CONTROL VALVE

CHAPTER II. This chapter contains a simplified description of the pipeline safety requirements. The complete text can be found in 49 CFR Part 192.

Unit 24: Applications of Pneumatics and Hydraulics

BACKPACK SPRAYERS. MODEL NOS: KSP16 & KSP20 Part Nos: & OPERATING & MAINTENANCE INSTRUCTIONS GC04/12

Air Eliminators and Combination Air Eliminators Strainers

BOWIE PUMPS OPERATION - MAINTENANCE

Material taken from Fluid Power Circuits and Controls, John S. Cundiff, 2001

Application of the Orifice Meter for Accurate Gas Flow Measurement page 1. Application of the Orifice Meter for Accurate Gas Flow Measurement.

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

Selection and Use of Water Meters for Irrigation Water Measurement 1

Rexroth Hydraulic Pump A10VO Series User Manual

Class 5 to 7 Truck and Bus Hydraulic Brake System

CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

Oregon Fuel Injection

Signature and ISX CM870 Fuel System

INSTRUCTION MANUAL. FOR Air Balance Jib Lifter MODELS COVERED:DSL-300 & DSL-300-P

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

Vacuum Control. Vacuum Applications. Vacuum Regulators. Vacuum Breakers (Relief Valves) Vacuum Control Devices. Vacuum Terminology

The Secret of Hydraulic Schematics. BTPHydraulics

System Saver 318 Air Compressor for Mack E-Tech and ASET Engines

Model 43AP Pneumatic Controller, Style B

Compressed Gas Cylinder Program

Air/Vacuum Valves. Removal of Air from Pipelines. Allow the Entry of Air into Pipelines. Application:

FUNDAMENTALS OF GAS TURBINE METERS John Gorham Sensus Metering Systems 805 Liberty Blvd. DuBois, PA 15801

Unit 24: Applications of Pneumatics and Hydraulics

HYDRAULIC LIFT TABLE CART 2200-LB.

B Dinesh Prabhu, Asst. Professor, P E S College Engg., Mandya, KARNATAKA 1

MASTER CYLINDER. Section 2. Master Cylinder. Tandem Master Cylinder. Master Cylinder

FJ2. 2 Ton Trolley Floor Jack Assembly & Operating Instructions

Cane Creek Double Barrel Instructions

Pump ED 101. Positive Displacement Pumps. Part I Reciprocating Pumps

T U R B I N E G A S M E T E R

COUNTERBALANCE VALVES

Below Grade Spill Containment Manholes Gallon Gallon Gallon. Installation Instructions

TECHNICAL DATA. Dry 122a. November 12, 2013

Steam System Best Practices Condensate System Piping

Daniel. Liquid Control Valves Technical Guide. Technical Guide DAN-LIQ-TG-44-rev0813. DAN-LIQ-TG-44-rev0208. February 2008.

M A N U A L

PART 2 FORKLIFT HYDRAULIC SYSTEM

ENGINE FUEL FUEL FILTER... FUEL HEATER... INJECTOR... SUPPLY PUMP... COMMON RAIL... FUEL PRESSURE LIMITTER...

1805 Series Relief Valves

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

Section 11 - System Diagrams

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

4" SUBMERSIBLE PUMPS

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

CG PTFE Diaphragm Liquid Transfer Pump

3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide

Section 6 - System Diagrams

Maxi-Stamper. 200 to 1,000 Tons STAMPING OUT DOWNTIME

NFPA31FuelOilPiping 1 Revised

HYDRAULIC TABLE CART 500-LB.

APPENDIX A CONTROL VALVE TESTING PROCEDURES AND EQUATIONS FOR LIQUID FLOWS

1/29/2008 DR70. Baja Motorsports Inc. P.O. Box Phoenix, AZ Toll Free: PART NUMBERS PRICES ARE SUBJECT TO CHANGE 1 of 43

SureSite Magnetic Liquid Level Indicator

Flow divider (flow distributor), type TQ

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

1/29/2008 DR125 / DR150. Baja Motorsports Inc. P.O. Box Phoenix, AZ Toll Free: PARTS AND PRICES ARE SUBJECT TO CHANGE 1 of 55

1. A belt pulley is 3 ft. in diameter and rotates at 250 rpm. The belt which is 5 ins. wide makes an angle of contact of 190 over the pulley.

Index Page. Pumping Systems Intensifiers Gas Boosters High Pressure Generators

CENTRIFUGAL PUMP SELECTION, SIZING, AND INTERPRETATION OF PERFORMANCE CURVES

NITROUS TRANSFER PUMP INSTRUCTIONS

Cryogenic Vacuum Pumps

Manual piston sampler...m 11

Oxy-Fuel Gas Welding. Given a functional oxy-fuel gas unit, instruction and demonstration of use, each student will be able to:

Fuel System Description. Stromberg 175 CD-2 SE And SU-HS 6 Carburettors

LPM-06 CONVERSION KIT

DR125 and DR150 Hensim Dirt Runner 125cc and 150cc Dirt Bike (VIN PREFIX LLCH or LUAH)

IOM SERIES 820-E/P Electro-Pneumatic Positioner

Working Drawing and Assemblies. Chapter 10

PNEUMATIC - HIGH PRESSURE FLAT-FORM HEAVY LIFTING BAGS

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

PBX Series Quick Fit Connector Bimetallic Steam Traps

HYDRAULIC ANALYSIS OF PIPE LINED WITH MADISON S 100% SOLIDS STRUCTURAL POLYURETHANE COATINGS

Cooling system components, removing and installing

MAINTENANCE OF WHEELMOVE IRRIGATION SYSTEMS

Slide the new steering column shaft through the steering column from the driver compartment.

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Fuel Injection Pump, Rotary ( )

Hydraulic Trouble Shooting

BETTIS CONVERSION INSTRUCTIONS TO CONVERT HD SERIES ACTUATORS TO HD-M3, HD-SR-M3 HD-M3HW OR HD-SR-M3HW SERIES PNEUMATIC ACTUATORS

Instructions and precautions. Fork Height. Visit our website at:

1 DESCRIPTION OF THE APPLIANCE

University of Tennessee Safety Guidelines

James M. Pleasants Company

Innovative Products For Unique Applications. A Tradition of Excellence. Creative Engineering for Fluid Systems. Earthquake Proof Valves

AIR LINE VALVES AND GAUGES

Buy Karcher Parts Online: Need Technical Help? Call: Requests to:

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800) Internet Address:

Transcription:

FUNDAMENTAL PRINCIPLES OF DIAPHRAGM METERS Robert Bennett American Meter Company INTRODUCTION The first gas company in the U.S., The Gas Light Company of Baltimore, Maryland, founded in 1816, struggled for years with financial and technical problems while operating on a "flat rate" basis. Its growth was slow with the charge for gas service beyond the pocketbook of the majority. By comparison, the New York Gas Light Company, founded in 1823, prospered and expanded. They had built their system on "the use of gas meters to measure the supply of gas to customers, and a large one to register the quantity made at the station before it is conveyed to the gasometers. COMPONENTS A diaphragm meter is physically composed of: 1.) A body to contain the gas pressure and form part of the compartments that measure the gas, 2.) Diaphragms that move as gas pressure fluctuates on either side, 3.) Valve covers and seats that control the flow of gas into each side of the diaphragm, 4.) Linkage to connect the diaphragm with the valves and index, and finally 5.) The index which registers the number of revolutions of the entire mechanism. (See Figure 1.) The pattern of operation used by this New York company was quickly copied by other companies throughout the East Coast, including the Baltimore company. Seeing the success, New York businessmen formed new gas companies in Albany, Boston, Philadelphia, New York, etc. and the new U.S. gas distribution industry began to flourish. Since this early beginning, meters have been an important, integral element in every phase of gas industry operations. Various types of meters are used; diaphragm, rotary, turbine, and orifice; each serving a definite purpose and meeting specific requirements. These four common types of meters can be broken down into two distinct categories: positive displacement and inferential. Diaphragm and rotary meters fall into the positive displacement category because they have welldefined measurement compartments that alternately fill and empty as the meter rotates. By knowing the volume displaced in each meter revolution and by applying the proper gear ratio, the meter will read directly in cubic feet or cubic meters. Turbine and orifice meters, on the other hand, have no measurement compartments to trap and then release the gas. These meters are inferential meters in that the volume passing through them is "inferred" by observing or measuring some physical characteristic. Figure 1. Diaphragm Meter A diaphragm meter can be compared to a two-piston double-action engine in which the diaphragms correspond to pistons and the meter body to the cylinders. Each stroke of the diaphragm displaces a fixed volume of gas and the diaphragms operate 90 0 out of phase so that when one is fully stroked, the other is at mid-stroke This provides a smooth flow of gas to the meter outlet and insures the meter will always start regardless of its static position. When a demand for gas is made on the downstream side of the meter, a pressure drop is created across the meter and its diaphragms. This differential, which amounts to 0.1" W.C., provides the force to drive the meter.

Figure 3. Tangent Adjustments STANDARDS Figure 2. Movement of a Diaphragm Meter Above each diaphragm is a "D" shaped valve (See Figure 2.). Under the valve are three port openings that direct the flow of gas in and out of the case and diaphragm compartments. As the diaphragm expands, it forces the gas in the case compartment up through the case port. The valve directs the flow of gas into the center port that leads to the meter outlet. A similar process occurs when the diaphragm contracts. The stroke of the diaphragm is controlled by linkage in the upper port of the meter and a rod (flag rod) that extends down into the diaphragm compartment. The tangent link, as it is called, is attacked to the top of the meter crank and is adjustable in length. Increasing the tangent length increases the diaphragms stroke which increases the meter proof and vice versa (See Figure3.) The crank makes a certain number of turns per cubic cubic foot and transmits this motion to the front counter (index) by means of an axle shaft driven by a worn and wheel. The crank also drives the sliding valves, which are timed to the motion of the diaphragm. To provide some common base for rating the capacity of various manufacturers gas meters, the ANSI B109.1 gas meter standard establishes a set of guidelines for meters with a capacity of less than 500 Cubic Feet Per Hour. ANSI B109.2 is the standard for diaphragm meters handling more than 500 Cubic Feet Per Hour and ANSI B109.3 covers the "Rotary Type Gas Displacement Meter. Both B109.1 and B109.2 define diaphragm type gas meter capacity as that volume of 0.60 specific gravity gas at an absolute pressure of 14.73 PSIA that will result in an average pressure drop through the meter of 0.5 inch of water column, using specified inlet and outlet connections. This capacity rating is not to be construed as a maximum capacity but as a common capacity rating base. Within the B109.1, meters are divided up into several classes: Class Capacity (ft 3 /hr) Minimum Maximum 50 50 174 174 175 249 250 250 399 400 400 499 This standard calls for new meters to be +1.0% accurate and +2.0% after accelerated life tests. (See Figure 4. for small meter test apparatus.)

Diaphragm meters meeting the requirements of both B109.1 and B109.2 will measure the gas flow to a pilot light starting at.25 ft 3 /hour for a Class 250 meter and smaller and up to 7 ft 3 /hour for a class 3500. The allowable accuracy at this flow is +10%. A typical accuracy curve for a diaphragm meter is shown in Figure 6. Figure 6. Diaphragm Meter Accuracy Figure 4. Test Apparatus The B109.2 (500 Cubic Feet or More) also divides large volume meters into several classes. Class Capacity (ft 3 /hour) Minimum Maximum 500 500 899 900 900 1399 1400 1400 2299 2300 2300 3499 3500 3500 5599 In addition to the capacity of the meter, its body must be physically constructed to withstand the internal pressure of the gas. Modern diaphragm meters have sufficient structural integrity to withstand a minimum shell test of 10 PSI. This is necessary to meet the federal rules contained in Part 192 of Title 49, Department of Transportation, Office of Pipeline Safety regulations. The end connections must be of sufficient size to allow easy passage of gas through the meter and can be some type of insert, NPT screw connections, or flanges. (See Table 1 for capacities and connections.) (Figure 5. shows a typical test stand used to determine meter capacities for large volume meters.) Figure 5. Large Meter Test Apparatus Table 1. Diaphragm Meter Capacities

INSTALLATION Hand-tighten the swivels first and then tighten with a wrench approximately three flats (approximately 20 ft-lb). Do not over tighten since damage to the rubber gasket inside the swivel cap may occur. Check all connections for leaks. Slowly pressurize the system. MAINTENANCE The diaphragm meter really does not require much maintenance other than a periodic proof test. Factors that affect meter accuracy include: Figure 7. Typical Diaphragm Meter Installation Diaphragm meters should always be shipped, stored, and installed in an upright position. Dust caps on the inlet and outlet connections should be left in place until the meter is installed. Caution should be used with meters that have been removed from service since they may contain gas within the diaphragm chambers. The meter set should be in a location that is ventilated and readily accessible for examination, reading, replacement, or maintenance. The set should be protected from outside damage and at least three (3) feet from known sources of ignition or air intakes. Electrical isolation for cathodic protection purposes should be maintained. A diaphragm meter should be installed as close to level as possible. Tests have indicated that tilting a meter will affect its accuracy since, at high angles, the valves tend to come off the valve seat and let the gas bypass the diaphragm chambers. Therefore, the inlet and outlet connections should be within + 1/4" of each other. The meter should be installed in a manner to avoid undue stress on the connecting piping or meter. The use of a meter bar may be a consideration. If there is foreign material such as sand, rust scale, or welding beads in the gas supply; then a filter or strainer should be provided on the inlet side. The meter should not be installed at the low point since it may act as a trap for liquids. By-pass piping or some other type of testing components, pressure taps, and over-speed protection should be considered. Avoid having the meter body come in direct contact with soil or concrete walls since alkali in concrete can cause premature corrosion. Under no circumstances should the meter be buried. 1. Internal Friction that increases meter differential. Excessively dirty or tacky valves or binds in the meter will cause higher differential pressures. 2. Maintaining Constant Diaphragm Displacement. A precise and stable diaphragm displacement is required for each stroke of the meter. Therefore, the effective cross-sectional area of the diaphragm and the diaphragm stroke must remain constant. 3. External Leaks. Any opening, such as cover gaskets, index seal box, or meter connections that lets gas escape will affect its accuracy. 4. Internal leaks will cause the meter to run slow and are usually found in areas such as the diaphragm assembly, valves, or flag rod seals. 5. Wear can affect accuracy in several ways. Wear at either end of the short flag arm or in the tangent bearing will cause the check rate proof to decrease while not appreciably affecting the open rate proof. Wear of the crank or crank arms will affect the timing of the valves that will increase the open rate proof. To determine the accuracy of a diaphragm meter, it must be tested or proved using conventional testing equipment such as a transfer prover bell, or sonic nozzle or. (See Figure 8. for examples.) a. Transfer Prover

REFERENCES -Gas Measurement Manual, Part Two, Displacement Measurement, American Gas Association, 1985. -ANSI B109.1, 2000, Diaphragm Type Gas Displacement Meters, American gas Association -ANSI B109.2, 2000, Diaphragm Type Gas Displacement Meters, American Gas Association -ANSI B109.3, 2000, Rotary Type Gas Displacement Meters, American Gas Association -Product Specification, Aluminumcase Meter, Domestic Size, American Meter Company b. Bell Prover c. Sonic Nozzle Figure 8. Proving Methods CONCLUSION Diaphragm Positive Displacement meters are and will continue to play a major role in natural gas measurement in the U. S. for the foreseeable future. Understanding how they work, their specifications, and how to install and maintain them are critical to having them perform in an acceptable manner. Robert Bob Bennett