Accu-Tab System CHLORINATION SYSTEM. Municipal Water/Wastewater and Industrial Applications

Similar documents
MC4-50 Feeding System

Repair and Disinfection of Water Mains Water Protection Program fact sheet

Problems with Hypo: Best Design Practices for Smooth and Efficient Sodium Hypochlorite Feed Systems Chad Hantelman, City of Bremerton Jeff Zahller,

Chemical Feed System Operation and Design Considerations

BULK WATER HAULING GUIDELINES

A GROUNDWATER PROTECTION PLAN FOR HOME HEATING OIL TANKS

01 - Plastic Pipe Cements and Primers

Revised April (May) 2015

Chemical Handling : Bulk Liquid Chemical Unloading. Northern Michigan Wastewater Operators Seminar September 23, 2008

More inside :: Tackle even the toughest water treatment piping challenges with

Keep the Water Moving Rehabilitation of a 1-million Gallon Water Storage Tank

Stenner Pump Chlorinator Installation & Start Up Guide

December 2003 EPB 241B. Some sections are completed, some are partially complete and some are left blank.

EMERGENCY VAPOR SCRUBBER SYSTEMS

Septic Tank to Cistern Conversions. Saving Water & Saving Money

Source Water Protection Practices Bulletin Managing Sanitary Sewer Overflows and Combined Sewer Overflows to Prevent Contamination of Drinking Water

Wastewater Collection Practice Test #3 Page 1 of 15

Indiana Department of Environmental Management. Well Disinfection

Water System Disinfection

Spill Kits and Incidental Spill Response

What To Do When Your Well is Flooded. Common Sense Steps To Take If Your Well Is Covered by Flood Water

CWD BALDWIN PLANT NEW RESIDUALS HANDLING SYSTEM

SECTION DISINFECTION OF PIPE AND WATER STORAGE FACILITIES

POOL SUNSHINE IONIZER MODELS SPD, SPD2 AND SPS INSTALLATION INSTRUCTIONS

Water Quality Contingency Planning Standard EPB 540B

Sample Test Questions

The following sections provide hazardous waste safety guidelines and procedures. This section covers the following topics:

Clean, Crisp Water Bottled Water Versus Tap Water

Basic Chemistry of Chlorination

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Proposed standard significant deficiency language is provided in italics. Notes to staff are provided in blue and are [bracketed].

White Paper. Chemical dosing and blending - the role of precision actuators

Disinfecting Your Private Well

Title: Aircraft Parking

TECHNICAL SPECIFICATIONS FOR LIQUID SODIUM HYPOCHLORITE

FLUSHMATE FLUSHMATE FLUSHOMETER - TANK SYSTEM. Owner s Service Manual 503 and 504 Series

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

Inline Chlorinator Chlorine Chemical Feeder

SEPTIC SYSTEM. Taking care of your. ... what you need to know

b. Alkalinity make your life easier and get the alkalinity between 80 and 120 PPM. c. ph from 7.2 and 7.8 so that the other chemicals work properly

OPERATIONS & MAINTENANCE (O&M) FOR PROPANE STORAGE FACILITIES

Ion Exchange Softening

FERTIGATION. Lawrence J. Schwankl

WASTEWATER MANAGEMENT SYSTEM

Presented By: Fred J. Sánchez Water Quality Operations Supervisor

Cubetainer. The competition can t stack up to Snyder! Stackable Tanks, Stands and Containments

MATERIAL SAFETY DATA SHEET

Florida Department of Environmental Protection

Fusion Series Treatment Systems Small Scale Residential & Commercial Treatment Units

STEM WASTEW ASTEWATER. Enhances property value while protecting the environment

Occidental Chemical Corporation ACL Chlorinated Isocyanurates Product Details

Town of New Castle Utility Department Introduction

Sample Test Questions

After the reactor has been running and the air in the chamber has been purged the co2 can be introduced and the dial in process can begin.

HAZARDOUS WASTE SATELLITE ACCUMULATION MANAGER RESPONSIBILITIES

Western Plant Health Association DOT MC 330 & 331 NH3 Cargo Tank Inspection Checklist Form

Treatment options for hydrogen sulfide. Testing for hydrogen sulfide

IBC Tote Containment Sumps

Rutgers Environmental Health and Safety

Ingredient CAS Number Weight % ACGIH TLV PEL STEL Phosphoric Acid mg/m3 1 mg/m3 3 mg/m3

CHECKLIST FOR INSTALLING OR CONVERTING EQUIPMENT TO DISPENSE E15, E30 E85 AND OTHER BLENDS OF ETHANOL General Information:

Routine Maintenance and Inspection

FOOD GRADE INDUSTRIAL OILS & GREASES

When Completed - Fax to (410)

Testing Water for Gardening and Lawn Irrigation

Water Treatment & Purification Chemicals

Nature's Cleaning Process

UTILITIES DEPARTMENT

Disposal of Pharmaceuticals, and their empty containers, in the Workplace

Corrosivity of Water Supplies

Summary of Distributor Obligations Under the OSHA Hazard Communication Standard as Revised by GHS

INSTRUCTIONS/INFORMATION HOW TO PROPERLY FILL OUT THE INDIVIDUAL MECHANICAL TREATMENT PLANT WARRANTY INSPECTION / SERVICE REPORT

Adjusting Chemical Levels in a Swimming Pool

The Use of Magnesium Hydroxide Slurry as a Safe and Cost Effective Solution for H 2

CERTIFIED SEPTIC EVALUATION PREPARED FOR MATT HASHEM 1673 MT. MAJOR HWY, ALTON, NH 03810

E-Version SECTION CHLORINATION SYSTEM PART 1 - GENERAL PART 2 - PRODUCT

TEX-AIRE, INC Pearl Drive Bossier City, LA

1805 Series Relief Valves

=.03% CO2 10/4/2012. Carbon Dioxide (CO2) Safety. Carbon Dioxide (CO2) Safety. Carbon Dioxide (CO2) Safety. Carbon Dioxide (CO2) Safety

OIL SPILL EATER LISTING OF OSE II ON THE US EPA NCP LIST LETTER

Heating Water by Direct Steam Injection

TEACHER ACTIVITY GUIDE

Drum Dispensing Stations

The Original and Patented Stackable Poly Tanks. When You Want to Beat the Drum!

ABC CIRCUITS 10 Circuit Drive Circuit Town, IN SLUG CONTROL PLAN

Mission Hill Water Treatment Plant & Kalamalka Lake Pump Station Upgrades

EMERGENCY PHONE: or (651) (24 hours)

How To Size A Stenner Pump

Installation Instructions

INSTRUCTION MANUAL. Boil-Out TABLE OF CONTENTS SAFETY WARNINGS 2-3 RESPONSIBILITY 3 INTRODUCTION 3 PRE-BOIL OUT PROCEDURES 3-5 BOIL OUT PROCESS 5-9

Site Attendance Guidelines for Automated/Unattended Monitoring and Process Controlled Facilities

Hazardous Waste Procedures. Faculty of Science University of Ottawa

Ground Water Rule Request for 4-log Certification Chlorination

Septic Tank Maintenance Information

MATERIAL SAFETY DATA SHEET

5: Types of Hazardous Waste

Hazardous Materials Spill Response

Practice Tests Answer Keys

123 Industrial Loop Road Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

Lids, Leaks, Labels and Location All About Satellite Accumulation Martin E. Sánchez Principal Environmental Specialist

Transcription:

A Cost Effective Solution with the Accu-Tab System Municipal Water/Wastewater and Industrial Applications Simple, Low-Cost System for Improved Operational Performance CHLORINATION SYSTEM

As Effective as Gas, More Consistent than Bleach and Easier to Maintain than Both. The Accu-Tab TABLET CHLORINATION system As regulatory requirements and safety issues provide increasing incentive for water treatment plants to reconsider their chlorination systems, the Accu-Tab system tablet chlorine solution provides safety and low-maintenance benefits as well as small capital investment, improving the performance of your plant. Since its introduction to the water and wastewater treatment segments in 1993, the Accu-Tab system by Axiall has become a leader in tablet chlorination. It is used as a cost-effective solution to chlorinate water plants as large as 14 million gallons per day (MGD) to smaller communities facing the unique challenges of well water disinfection. Throughout the United States and Canada, the Accu-Tab system is used in drinking water applications for primary treatment or remote booster stations. As an effective and reliable alternative to gas and bleach, the Accu-Tab system combines specially engineered chlorinators with controlled-release 68% three-inch calcium hypochlorite tablets in a complete system that delivers consistent and controllable chlorine residuals. accu-tab.com

SAFER. The Accu-Tab system minimizes the safety concerns typically associated with the use of chlorine gas and bleach in water treatment. The Accu-Tab chlorination system: Removes the risk of leaks common with the use of chlorine gas cylinders. Eliminates the need for an expensive safety system. Just rubber gloves and safety goggles are needed to handle calcium hypochlorite tablets. Reduces the need for elaborate risk management programs associated with chlorine gas cylinders. SIMPLE. It doesn t get much easier than the Accu-Tab chlorination system: Integrates easily with existing systems and Axiall-trained specialists are available to provide expert installation and technical support. Requires only one person to load tablets and maintain the system. The unique three-inch calcium hypochlorite tablets are shipped in convenient and easy-to-store 55-lb. pails. Has few moving parts, no metering pumps, and no small openings that can clog making for a trouble-free, low maintenance solution to water treatment. EFFECTIVE. Providing consistent chlorine delivery for improved performance. The Accu-Tab chlorination system: Erodes controlled release tablets at a predictable rate. Reduces disagreeable tastes and odors while killing harmful bacteria.

How the Accu-Tab System Works The Accu-Tab system is easy to install and can be integrated into any existing system with low capital investment. Once in place, the system runs simply and efficiently with little to no maintenance. Before water is moved into distribution, a side stream flows through the chlorinator and contacts the Accu-Tab tablets inside. The tablets erode at a predictable rate based on the flow rate of the side stream, allowing for a consistent delivery of chlorine. Once the water is chlorinated, it is injected back into the main water line. The chlorinator automatically stops when the water flow is shut off, keeping the tablets dry when the unit is not in operation. A control valve at the inlet allows precise chlorine residual control. Both manual and automatic control systems are available for your plant s specific needs. A side stream flows to the chlorinator. Accu-Tab three-inch tablets sit on top of a sieve plate inside the chlorinator. Intake water flow to the chlorinator is adjusted to control chlorine delivery. Untreated water rises through holes in the sieve plate contacting with bottom of tablets. The balance of the tablets remain dry. Water is returned to the system with the appropriate amount of chlorine. Chlorinated water stream meets main water flow and continues to distribution. ACCU-TAB System POWERPRO CHLORINATOR SYSTEM PUMP accu-tab.com TO DISTRIBUTION SOURCE WATER

The Accu-Tab Chlorinator and Tablet Advantage Clockwise from top: Accu-Tab system PowerPro 3075 chlorination unit (shown with automated controller and weigh scale options); Accu-Tab Series 2075P chlorination unit; and Accu-Tab tablets. Accu-Tab chlorinators are made of rigid PVC with a wide range of sizes available to meet any chlorination need or requirement. With few moving parts, Accu-Tab chlorinators offer low maintenance and eliminate any concerns of spills or leaks. Accu-Tab tablets offer a more neutral ph level and are less corrosive than other chlorination methods. Only three inches in diameter, the tablets are easily dropped into the chlorinator and allow for easy storage with packaging in 55-lb. pails.

The Power of the Accu-Tab System Over Bleach and Gas FACTORS ACCU-TAB SYSTEM GAS BLEACH Safety Easy to handle, no spills Major gas leak concerns Spill and leak concerns Charging chemical Easy to add tablets, only one person needed Two trained persons needed, breathing protection required Hard to maneuver, heavy drums or lots of small carboys Material compatibility More neutral ph, less corrosive Low ph, very corrosive High ph, corrosive Convenience 55-lb. pail of tablets is easy to handle Hard to maneuver cylinders, special handling training needed Bleach drums are awkward to handle Maintains chlorine strength Small change over a year Consistently 100% chlorine Significant assay loss in a week Chlorine delivery control Consistent strength makes for easy, reliable control Troublesome regulators needed, harder to automate Ever-changing strength makes for control difficulty Storage convenience 55-lb. pails stacked three high, same space as 150-lb. cylinder, no separate room Separate room with special access needed, fans, scrubbers Drums or bulk tanks require space and possible containment pad Auxiliary equipment No moving parts in chlorinator itself Eductors, regulators have small orifices prone to plugging Troublesome metering pumps required accu-tab.com The Accu-Tab system offers a safe and state-of-the art approach to municipal water treatment for improved operational performance in your water treatment plant. The calcium hypochlorite technology of the Accu-Tab system is used worldwide and is certified or approved by NSF, USDA, EPA, FDA and AWWA. In addition to municipal water, Accu-Tab systems are used in applications for poultry plants, red meat processing, fruit and vegetable processing, beverage plants, irrigation and other specialized uses.

Visit www.accu-tab.com/ for more information. Accu-Tab System for Municipal Water SAFEr. Safe alternative to gas and bleach No leaks SIMPLE. Low maintenance Requires smaller footprint than similar bleach systems EFFECTIVE. As effective as gas, more consistent than bleach Low capital investment Contact your Accu-Tab system specialist to learn how the system can work for you.

Behind Every Accu-Tab System is the Power of Axiall Corporation At the intersection of chemistry and progress. Axiall represents a new kind of chemistry company; one that works to responsibly harness applied chemistry to solve common problems, improve everyday life and drive human progress. Blending a strong, downstream building products business with core materials capabilities, Axiall delivers life-enhancing benefits. Axiall s chemical products can be found in high performance plastics, pulp and paper production, packaging, chemical intermediates, pharmaceuticals, medical and agricultural applications and paints, acrylics and varnishes. With its scale and resources, Axiall is committed to being a leader in sustainable practices, a responsible environmental steward, and a force for progress. Accu-Tab System Certification and Approvals NSF Standard 60 and 61 listed for drinking water USDA approved uses: D2, G4, G5, G7 and Q4 for SI tablets AWWA Standard B-300 FDA Approval 21CFR178.1010 EPA Registration #748-295 Kosher approved CHLORINATION SYSTEM Axiall Water Treatment Products 11 Stanwix Street Pittsburgh, PA 15222 800-245-2974 www.accu-tab.com Statements and methods presented about the products mentioned herein are based upon the best available data and practices known to Axiall Corporation at present, but are not representations or warranties of performance, results or comprehensiveness, nor do they imply any recommendations to infringe any patent or any offer of license under any patent. The products mentioned herein can be hazardous if not properly used. All purchasers of these products should communicate all the health and safety information contained herein to their customers or employees, as the case may be. Axiall Corporation recommends that before anyone uses or handles the products mentioned herein, he or she read and understand the precautionary and other information on the product label, as well as in the material safety data sheet and product bulletin. Although the products mentioned herein are intended for industrial and manufacturing uses, they are potentially hazardous and must be kept out of the reach of children. Accu-Tab, the Accu-Tab system design, PowerPro and the Axiall logo are registered trademarks of Axiall Ohio. 2013 Axiall Corporation. All Rights Reserved. 3003 5M 1013