Refrigeration Air Dryers ADQ. Capacity: 21-4200 m 3 /h

Similar documents
Kompressoren. Compressed Air Filters PF/DF/MF/SF/AF

CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!

Kompressoren. Adsorption Dryer AD

Refrigerated Air Dryers. Catalogue

Kompressoren. Oil Water Separators OWS

Refrigeration Air Dryers. Catalogue

ThermoStar Refrigeration Air Dryers

ThermoSorb Desiccant Dryers

Refrigeration Compressed Air Dryer Buran Ultrapulse

Rotary screw compressors kw 5,5 7, , bar MODULO

ETC -SV. Class 0 oil-free compressed air through catalysis

Adsorption air dryers ADS 1 215

OIL-FREE ROTARY SCROLL COMPRESSOR. ECOLIFE 1,5 15 kw

MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM. Key features: NOVAIR quality and service:

clean and quiet dental

FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS


LG Electronics AE Company, Commercial Air Conditioning

Condensate Treatment Solutions. CTS Series Eliminator II Oil-Water Separators

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

Screw Compressors ESM Fixed Speed & VS Variable Speed

IV. Rear Mount System

Compressed Air Filters

Refrigeration Dryers SECOTEC Flow rate 0.6 to 14.3 m³/min

Medical Air Systems: Scroll

Rotary Screw Compressors UP-Series 4 & 5.5 kw

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

How To Clean Water From An Ammonia Refrigeration System

OIL-INJECTED ROTARY SCREW COMPRESSORS. GA (VSD) ( kw/ hp)

Troubleshooting HVAC/R systems using refrigerant superheat and subcooling

Owners Manual. Refrigerated Air Dryer. HX75 thru HX2400

High Pressure Dryer HLP-MSD 0055 to 0870, PN 100 to PN 400

Rotary Screw Compressor. MSM MINI 2, ,5 kw

Compressed air conditioning

GAS HANDLING SYSTEMS VACUUM INSTRUMENT CORPORATION

ultrafilter VARIOBLO Heat Regenerated Adsorption Dryer

Series IDU/IDF. Refrigerated Air Dryer

Atlas Copco. Oil-injected Rotary Screw Compressors GA 15-22/GA /GA VSD (11-30 kw/15-40 hp)

Basic Hydraulics and Pneumatics

Screw Compressors 11-22kW

EnviroAire Series. 15kW 110kW Oil-Less Rotary Screw Compressors ILLESS

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

DRYPOINT AC HP PREMIUM HIGH-PRESSURE DRYING

Oil-Free Screw Compressors. Water-injected Technology. Rely on GD to provide the perfect fit

Glossary of Heating, Ventilation and Air Conditioning Terms

Refrigerated Compressed Air Dryers

HYDRYER TYPE P Heat Regenerative Dryers ISO 9001 CERTIFIED

Nirvana. Cycling Refrigerated Dryers

Compact Air Solutions C Series kw Screw Compressors Want a 5. year warranty? Ask for details!

ultrafilter HEATLESS HL Adsorption Dryer

ECOCIAT. Domestic hot water heat recovery unit

AIRROLLAIR COMPRESSORS E

Dryaire Desiccant System

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

Electronic Condensate Drains ECO-DRAIN Series

In-Line Filters and Coalescers with Automatic Drains

Hot Water. Heat pump water heaters. Residential and Commercial R410a

DRYPOINT RA REFRIGERATION DRYER RANGE

ROTARY SCREW COMPRESSOR. RMD kw

Atlas Copco. On-site Industrial Gases Nitrogen & Oxygen Generators

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Refrigeration and Airconditioning Prof. M. Ramgopal Department of Mechanical Engineering Indian Institute of Technology, Kharagpur

On request of Akzo Nobel Dynamo Project Team we ve surveyed the energy efficiency of the compressed air system in the Barcelona Deco & A/AS plant.

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

Innovative to the Core

National Grid Small Business Energy Efficiency Program Overview. Central New York Energy Expo March 30, 2010

Quality air solutions. Refrigerant Dryers Adsorption Dryers Filters Oil-Water Separators Accessories

Automobile Air Conditioning Primer

Atlas Copco Compressed air dryers. CD series Heatless adsorption dryer series HIGH QUALITY DRY AIR

york air-conditioning products Residential & VRF News 2015

REFRIGERATED COMPRESSED AIR DRYERS

Compressed Air Filters KAESER FILTER Flow rate 0.60 to m³/min

III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014

GA GA VSD

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

USER S MANUAL HSC-24A

Atlas Copco Stationary air compressors

Under sill units. Type FSL-B-ZAS

CONDENSATE MANAGEMENT

Desiccant Air Dryers Heatless, Heated and Heated Blower

Thermostatic valve Type AVTA

Owners Manual Refrigerated Air Dryer

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

HP switch LP switch Discharge thermo Comp. Surface thermo

Owners Manual 2009 PRICE LIST DRYMAXTM. Compressed Air Treatment Products. Refrigerated Air Dryers

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

A discussion of condensate removal systems for clarifier and thickener drives for water and wastewater facilities.

New Trends in the Field of Automobile Air Conditioning

Medical Air Plant. uair Series (7-145 l/s / cfm)

DTC B1423/23 Pressure Sensor Circuit

Perfection for Professionals: Air Conditioner Service with Bosch ACS 751 and 651

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure

Refrigeration Basics 101. By: Eric Nelson

HELPFUL HINTS ON PREPARING COMPRESSED AIR

Water Separator. Main Line Filter. Mist Separator. Micro Mist Separator 150C 250C 350C 450C AMG 550C 2C 4C 8C 11C AFF 22C 37B 75B 150C 250C 350C 450C

Split units TH with hermetic compressors

Dehumidification Frequently Asked Questions

Lava. Precision Solutions. Site Planning and Installation Guide

Why and How we Use Capacity Control

Transcription:

Refrigeration Air Dryers Capacity: 21-4200 m 3 /h

Water Contamination in Compressed Air T he w a t er c o n t a i n e d i n a c o m p r e s s e d a i r s y s t e m w i l l va r y acc o r d i n g t o a m b i e n t c o n d i t i o n s, i. e. t e m p e r a t u r e a n d h u m i d i t y. A f t e r c o m p r e s s i o n t h e wa t e r va p o u r w i l l t r a v e l i n t o t h e s y s t em in e x a c t l y t h e s a m e w a y a s the co m p re s s e d a i r i t s e l f. A basic co m p re s s e d a i r s ys tem will include an af t e rco oler w h i c h w i l l a l l o w t h e r e m o v a l o f s o m e o f t h e c o n d e n s a t e, d e s p i t e t h i s h o we v e r a l a r g e q u a n t i t y o f w a t e r w i l l e nt e r t h e d i s t r i b u t i o n s ys te m. Fo l l ow i n g e n t r y i n t o t h e d i s t r i b u t i o n s ystem, the compressed air will undergo f u r ther co o l i n g a n d ex p a n s i o n a n d a s a result condensate will collec t in the d i s t r i b u t i o n p i p e wo r k a n d a n c i l l a r y d ev i ce s. O v e r t i m e t h e c o n d e n s a t e i n t h e p i p e w o r k m ay c a u s e co r r o s i o n a n d s u b s e q u e n t l y f a i l u r e a n d l e a k s. Fu r t h e r m o r e the c o n d e n s a t e p r e s e n t i n a l l o f t h e d ow n s t re a m p n e u m at i c e q u i p m e nt will c a u s e s e r i o u s d a m a g e re s u l t i n g i n b re a k d ow n s, a d d i t i o n a l m a i nt enance and incre a s e d p ro duc tion co s t s. I n a p p l i c a t i o n s w h e re co m p ressed air is in contac t with the f i n a l p r o d u c t, d a m a g e m ay o c c u r t o t h e p ro duc t i t s e l f i n c re a s i n g co s t s f u r t h e r. The refrigerated compressed air dryer employs refrigeration technology in order to cool the compressed air to the optimum temperature in order to remove condensate (dewpoint) and is designed to remove up to 99 % of the condensate present. THE DANGERS AND RISKS OF WATER CONTAMINATION - Corrosion to the distribution system: the water that collects in the system over time will cause corrosion and consequently leaks, increasing your compressed airconsumption and therefore energy costs. Furthermore the scale formed inside the pipe work distribution system as a result of corrosion will increase pressure losses resulting in a further increase in energy and operating costs. - Malfunction to pneumatically operated machinery and devices: The contamination in all of the pneumatic equipment will result in lower productivity, poor reliability, increased maintenance and down time resulting in an overall reduction in manufacturing efficiency. - Spoilt products: The contamination in compressed air will have a direct influence on the quality of the manufactured goods. Imperfections caused by poor finishing when paint spraying or the presence of contamination in packaging, electronic or pharmaceutical applications can have a dramatic impact on product quality and performance.

dryers Air purity For many companies in today's competitive global market, the treatment of compressed air is not an option, but a necessity to reduce operating costs and increase production efficiency. Being an efficient and simple technology, refrigeration dryers represent the preferred solution for the majority of these applications. The ALUP Kompressoren dryers have been developed to supply dry compressed air for your production process, with a minimum power requirement and low pressure drop for optimum efficiency. Pre-cooled air enters the air/refrigerant gas heat exchanger where the compressed air temperature is reduced. This causes condensate to develop and the correct dewpoint to be achieved. The cold air then passes through the air/air heat exchanger, raising it to a temperature where no condensate will ensue in the pipe distribution system. 9 6 7 1 In a sealed circuit, refrigeration gas is compressed, condensed, expanded and then cooled to form a liquid at approximately 0 C. Air Outlet 10 Air Inlet 8 2 Warm air entering the dryer is pre-cooled in an air/air heat exchanger by air that has been through the refrigeration circuit. Air Inlet Primary condensate flow Secondary condensate flow Air Outlet Refrigerant gas/liquid mixture 11 Cold air and water enter the condensate separator which separates the liquid water from the air. Water is then discharged by the automatic condensate discharge. Low pressure, cool refrigerant gas High pressure, hot refrigerant gas High pressure, refrigerant liquid Low pressure refrigerant liquid 5 4 3 1 Refrigerant compressor 2 Refrigerant condenser 3Fan 4 Refrigerant filter 5 Capillary tube 6 Air/refrigerant heat exchanger 7 Liquid separator 8 Hot gas by-pass valve 9 Air/air heat exchanger 10 Condensate separator 11 Automatic condensate discharge

TECHNICAL SPECIFICATIONS Types 21 36 51 72 110 141 180 2 246 312 390 462 600 720 900 1080 1440 1800 2100 3000 4200 Flow treated according to temperature of compressed air input 1 35 C. 40 C. m 3 /h. Cfm m 3 /h. Cfm 21 12.4 17.2 10.2 36 21.2 29.5 17.4 51 30.0 41.8 24.6 72 42.4 59.0 34.8 110 64.4 90.2 52.8 141 83.0 1 68 180 106 148 87 2 127 177 104 246 145 202 119 312 184 256 151 390 230 320 189 462 272 379 223 600 353 492 289 720 424 590 348 900 530 738 435 1080 636 886 522 1440 848 1181 695 1800 1060 1476 869 2100 1237 1722 1014 3000 1766 2460 1448 4200 2472 3444 2027 45 C. m 3 /h. Cfm 14.5 8.6 24.8 14.6 35.2 20.7 49.7 29.3 75.9 44.4 97 57.27 124 73 149 88 170 100 215 127 269 159 319 188 414 244 497 293 621 366 745 439 994 585 1242 731 1449 854 2070 1219 2898 1706 Nominal electrical power 1 kw 0. 0. 0.19 0.27 0.28 0.61 0.67 0.79 0.87 1.07 1.19 1.45 1.82 2.01 2.64 3.57 3.90 4.46 5.55 6.80 10.20 Power supply voltage V/Hz/Ph 230/50/1 400/50/3 Max. operating pressure bar Refrigerant gases R4a R404A Air connections gas/dn 1"F 1"F 3"F 3"F 3"F DN125 DN125 Weight Kg. 19 19 20 25 27 44 44 53 60 65 80 80 128 146 158 5 325 335 350 550 600 NOTES: 1 Reference conditions - Operating pressure : 7 bar (100 psi) - Operating temperature : 35 C - Room temperature : 25 C - Pressure dew point : +3 C +/- 1 - Available in different voltages and frequency values Limit conditions: - Working pressure : bar (232 psi) ( 21 up to 110) : bar (188 psi) ( 141 up to 4200) - Operating temperature : 55 C - Min/Max room temperature : +5 C; +45 C CORRECTION FACTOR FOR CONDITIONS DIFFERING FROM THE PROJECT K = A X B X C Room C 25 30 35 40 45 Operating C 30 35 40 45 50 55 temperature A 1.00 0.92 0.84 0.80 0.74 ( 21 up to 462) temperature B 1.24 1.00 0.82 0.69 0.58 0.45 ( 21 up to 462) 1.00 0.91 0.81 0.72 0.62 ( 600 up to 4200) 1.00 1.00 0.82 0.69 0.58 0.49 ( 600 up to 4200) Operation pressure bar 5 6 7 8 9 10 11 12 14 15 C 0.90 0.96 1.00 1.03 1.06 1.08 1.10 1.12 1. 1.15 1. 1.17 ( 21 up to 462) 0.90 0.97 1.00 1.03 1.05 1.07 1.09 1.11 1.12 ( 600 up to 4200) The new flow rate value can be obtained by dividing the current or real flow rate by the correction factor related to the real operation conditions. DIMENSIONS B C A A B C 21 to 110 350 484 511 141 to 180 370 764 515 2 to 312 460 789 575 390 to 462 580 899 604 Dimensions in mm A B C 600 to 1080 735 10 898 1440 to 2100 1020 1560 1082 3000 to 4200 100 1560 2099 Dimensions in mm C A B COMPACT INSTALLATION Unique, light, and compact design makes dryer handling easy. The installation of the dryer is simple and requires no special equipment or foundation work. To ensure operational reliability of the dryer range, it is recommended to install a ALUP Kompressoren pre-filter upstream of the dryer and a high efficiency oil removal filter downstream of the dryer to protect the air system against particle and oil contamination.

dryers 'AUTOMATIC ZERO LOSS' CONDENSATE DRAIN All models are fitted with a SMART condensate drain. Each unit is specifically sized to each dryer and provides extremely reliable operation. The drain allows the removal of condensate only with no wasteage of compressed air resulting in significant energy savings. The standard alarm facility warns the operator of any malfunction. Allows for the discharge of condensate only and NOT compressed air. Silent operation provides a more comfortable environment. OPTIONS FOR BY PASS VALVE + FILTER SUPPORT FILTER SUPPORT The optional by-pass facility allows the system to operate using the filters only during maintenance or malfunction to the dryer thus avoiding any down time. This option allows two filters to be installed on the rear side of the dryer, reducing overall dimensions and installation costs. PS: Filters are not included in the option. ENVIRONMENTALLY FRIENDLY A key objective in the design of the dryer was to arrive with a product that offers performance, reliability and safety with lowest possible environmental impact. Thanks to the use of new technology and materials this major achievement that would not have been possible even a few years ago is now a reality. No compressed air wastage during the condensate discharge phase. Noiseless condensate discharge operation. Environmentally friendly thanks to the use of R 4a and R404A gas. No impact on the ozone layer. Gas R4a Gas R404A High energy savings due to low pressure drops throughout the system. Cleaner compressed air distribution network for higher quality air supply applications.

Products, Concepts, Solutions Built on the needs of the customer For almost 100 years, we at ALUP have produced quality air compressors. With our innovative system concepts we offer customised solutions for almost all applications. Our endeavour lies not only in supplying compressors, we offer ourselves as a competent system provider, who is able to offer solutions to all users of compressed air. That does not only apply to the consultation and installation phase of your new compressor(s), but naturally continues in all areas of service, maintenance and visualisation. Challenge us! Screw compressors Piston compressors Blower Turbo compressors Complete accessories Control, regulate, monitor constant speed 2.2 400 kw/ 5 bar variable speed controlled and direct drive 5.5 260 kw/ 5 bar oil-free, with water injection 15 55 kw/ 5 10 bar oil-free, up to 10 bar 0.75 12 kw for normal pressure up to 10 bar 1.5 15 kw for medium pressure up to 15 bar 1.5 15 kw for high pressure up to 40 bar 2.2 45 kw as a booster for an input pressure up to 15 bar and an output pressure up to 40 bar 2.2 30 kw at constant speed 1.5 55 kw 300 1000 mbar with speed regulator and direct drive 3.0 55 kw 300 1000 mbar oil-free, up to 9 bar 65 370 kw refrigeration dryers 0.27 100 m 3 /min desiccant dryers 0.08 145 m 3 /min activated carbon adsorbers 0.08 145 m 3 /min filters, all particle sizes 0.5 225 m 3 /min complete condensate management up to 120 m 3 /min lead-lag control consumptiondependant control visualisation (we bring your compressed air to the PC) tele-monitoring (the hotline of your compressed air station) Your specialist ABAC UK LTD UNIT 11, GRANVILLE WAY CHAUCER BUSINESS PARK BICESTER OXON OX26 4JT TECHNE Tel: 01869 326226 Fax: 01869 3262 Email: enquiries@abac.co.uk Web: www.abac.co.uk