Bosch Climate Water Source Heat Pump

Similar documents
LG Electronics AE Company, Commercial Air Conditioning

york air-conditioning products Residential & VRF News 2015

Natural geothermal energy.

How To Use A Water Source Heat Pump

CRAC Precision climate control units for data centres

ECOCIAT. Domestic hot water heat recovery unit

GEOTHERMAL HEATING AND COOLING INTRODUCTION

Daikin Altherma hybrid heat pump. The natural combination

HVAC Systems: Overview

The heat is there let s use it! Using free environmental heat from the air with heat pump technology for central heating and domestic hot water

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

Hot Water. Heat pump water heaters. Residential and Commercial R410a

CoolTeg Plus Chilled Water (CW) version: AC-TCW

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

Create the right atmosphere with renewables.

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy

Daikin Altherma. hybrid heat pump. The natural combination

Yijun Gao, Wei Wu, Zongwei Han, Xianting Li *

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

Cooling kw Heating kw

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

Saving energy by solar collector and heat pump combination in hot water production in residential and hotel sectors

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

High-efficient gas boiler CompactGas

ROTEX gas hybrid heat pump. A strong team.

Renewable Heat Pumps. A guide for the technically minded

Chilled Water Precision Air Conditioner For Critical Application

HEATING, VENTILATION & AIR CONDITIONING

Commercial Hot Water. Make a difference...

Energy Efficiency and Intelligent Store Solutions

Creating Efficient HVAC Systems

Vicot Solar Air Conditioning. V i c o t A i r C o n d i t i o n i n g C o., l t d Tel: Fax:

The natural ombination

How a Ground Source Heat Pump Works for Commercial Buildings

Versati Air to Water Heat Pump

Development of Air-to-Water Heat Pump for Home Air conditioning/hot Water Supply Combination System with Chilled/Hot Water in European Markets

imagine SOLAR AIR CONDITIONING MADE EASY

State of the Art Energy Efficient Data Centre Air Conditioning

How Ground/Water Source Heat Pumps Work

Delivering exceptional performance and Ecovalue. Ecocent

Ground Source Heat Pumps The Fundamentals. Southington, Connecticut John F. Sima III P.E.

Steam and hot water boiler systems for industrial and municipal power generation Dr.-Ing. Wolfgang Sobbe VKK Standardkessel Köthen GmbH

Vitocaldens 222-F Compact Gas-Hybrid appliance

Nordic Heat Pump Product Guide

The ASHRAE HQ Building Can the energy efficiency of the different mechanical systems really be compared? RESIDENTIAL LIGHT COMMERCIAL COMMERCIAL

Variable Capacity Compressors, a new dimension for refrigeration engineers to explore

HP switch LP switch Discharge thermo Comp. Surface thermo

CA SERIES. Available in sizes from 3/4 through 1-1/4 tons the CA Series offers a wide range of features such as:

HOT & COLD. Basic Thermodynamics and Large Building Heating and Cooling

Gas Absorption Heat Pumps. Future proofing your heating and hot water

Refrigeration Compressed Air Dryer Buran Ultrapulse

DESIGN OF AIR CONDITIONING SYSTEM IN AUTOMOBILE

III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment. Precision Cooling For Business-Critical Continuity

HEAT PUMPS A KEY COMPONENT IN LOW CARBON FUTURE

Building Energy Systems. - HVAC: Heating, Distribution -

Glossary of Heating, Ventilation and Air Conditioning Terms

Air Conditioners Technical Data

DAikin Altherma low temperature heat pump. end user leaflet

Technical data. Danfoss DHP-A

Life Cycle Costing Analysis of Water-cooled Chillers. Chillventa Nuremburg, Germany

In the compression-refrigeration loop (air conditioning), which is likely to be warmer? 1. Condenser coil 2. Evaporator coil

The Concept. How Cassettair can benefit you. Applications. Selecting Cassettair

SustainE(Sustainable Energy)

How does solar air conditioning work?

A Comparison of an R22 and an R410A Air Conditioner Operating at High Ambient Temperatures

Geothermal Ice Arenas

Selection Tips For Air-Conditioning Cooling Systems

Fan Coil Units. Fan coil units with brushless DC motor with inverter. your comfort. our world. » Up to 70% energy saving with BLDC motor technology

GEOTHERMAL HEAT PUMPS - TRENDS AND COMPARISONS - John W. Lund Geo-Heat Center

KSV70HRF. KSV70HRF - 7.1kW Split System Air Conditioner - Reverse Cycle

Air conditioners Heating & Cooling

FULL DC INVERTER SYSTEMS

EnergyPro Building Energy Analysis. Assisted Living Building

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

Design and Implementation of Geothermal Systems for Heating and Air Conditioning

The Different Types of Air Conditioning Equipment for IT Environments

Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now

The natural ombination

Chapter 3.4: HVAC & Refrigeration System

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

How to choose a heat pump and use it wisely

Energy Efficiency Technologies Air Source Heat Pump vs. Ground Source Heat Pump

Energy Recovery Systems for the Efficient Cooling of Data Centers using Absorption Chillers and Renewable Energy Resources

Serenbe Green Geothermal Solutions with Bosch Thermotechnology

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

Direct Fresh Air Free Cooling of Data Centres

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

Chiller/Heat pumps 30AWH. Reversible. Monobloc inverter

CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!

International Telecommunication Union SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF TELECOMMUNICATION CABLES IN PUBLIC NETWORKS

Rotary screw compressors kw 5,5 7, , bar MODULO

Forty-one miles of submerged coils that heat and cool a high school of 2,400 students.

How a Ground Source Heat Pump Works for a School or College

1116, Suenaga, Takatsu-ku, Kawasaki , Japan

Transcription:

Bosch Climate 5000 Water Source Heat Pump

2 Water Source Heat Pump Introduction to Bosch Thermotechnology Bosch Thermotechnik GmbH is a leading supplier of resource-efficient heating products and hot water solutions in Europe. In fiscal 2013, the company generated sales of 3.1 billion Euros (68% outside Germany) and employed approximately 13,500 people. Bosch Thermotechnology has strong international and regional brands and manufactures a diversified product range in 21 plants in 11 European, North American and Asian countries. In 2013, Bosch Thermotechnology invested 129 million Euros in research and development. Intelligent networks and local systems for heating, ventilation, air-conditioning and electricity generation are fundamental technologies for the future building standard, which will generate more energy than is used. In Southeast Asia, Bosch Thermotechnology has been established in the middle of 2011 to provide a closer support to its local customers as well as to further extend its market position. The regional headquarter office is based in Singapore, overseeing business development in the Southeast Asia region. Nowadays, Bosch Thermotechnology has successfully established sales offices in Indonesia, Malaysia, Philippines, Singapore, Thailand and Vietnam with a representative office in Myanmar. Bosch Thermotechnology is mostly known in Southeast Asia for its large-scale, commercial and industrial boiler systems. In 2014, the product portfolio has been extended to cooling solutions which are energy efficient, eco-friendly and high quality products for commercial and industrial applications which help our customers to increase comfort and reduce energy cost. A comprehensive range of renewable heat pumps, chillers, fan coil units and air handling units meets almost all kinds of requirements from buildings like office, hospital, hotel, shopping mall or industrial plants. Bosch Climate 5000 Water Source Heat Pump is a product engineered with most advanced technology which brings you great energy saving, and an ultimate quiet and comfortable indoor environment. Achieve independence, save energy and protect the environment - for a secure future Higher energy prices and the increase in environmental pollution compel us to change our heating and cooling behavior and look at new forms of energy. Our future energy usage must include renewable energies for heating and cooling. Heat pumps are an excellent alternative when it comes to making efficient use of these free sources of energy. Renewable energies make you independent from oil/gas prices, protect the environment and your bank account. Natural heat: 100% efficient, and up to 80% free of charge As you know, heat is our element. But did you know that heat is in nearly every element? Nature is an excellent supplier of energy and stores the heat of the sun, for instance, in the ground and surface water. With Bosch heat pumps, you simply draw this energy into your own home and, what s more, it is practically free, up to 80% of the required heating energy is given to us by nature; you can see it in a significant reduction in your utility costs.

Water Source Heat Pump 3 I provide the climate. You feel the comfort! Bosch Water Source Heat Pumps The energy of the future Everything speaks in favour of Bosch heat pumps. Not only do they have reduced running costs, but also reduced environmental pollution effects, and as they produce zero emissions, so the choice is simple. Heat pump principle Water source heat pump is a kind of air conditioner. To explain how a heat pump works, the best place to start is the air conditioner in your house. Air conditioners remove heat from inside the room and transfer it to the outside. Heat pumps in heating mode essentially work in the same way- only in reverse. However, what is crucial here is how the heat is transported. This task is performed by a refrigerant- a fluid with a particularly low boiling point. The refrigerant absorbs the ambient heat from the ground water, for instance, and in doing so, it evaporates. A compressor compresses this vapor and raises the pressure. This increases the temperature further until it reaches the desired level, thus producing a flow of heat. The vapor transfers the heat to indoor air and then reverts to a fluid. An expansion valve reduces the pressure to its original level the fluid cools down and the cycle starts again: heat can be absorbed and transferred to the heating system. That is how simple heating can be. Incidentally, the heat pump does all this without producing any emissions.

4 Water Source Heat Pump Does heat come from the ground or from the water? Bosch has the right answer for you Heat is our element If you are banking on renewable energy for heating and cooling, you now have a good reason to think you re right. Using this technology you can save a lot of money and protect the environment from harmful emissions. Water source heat pump (WSHP) WSHPs are heat pumps which use water as source of heat for heating and cooling. They are always used in two kinds of heat pump systems-geothermal systems and water loop systems. Geothermal heat pump system Geothermal heat pump system uses the natural heat storage ability of the earth, ground water or surface water as main source for heating and cooling. It consists of water source heat pumps, ground heat exchanger, indoor air conditioning system and control systems. Typical designs for geothermal heat pumps include ground loop system (vertical loops in boreholes & horizontal loops in trenches), ground water system and surface water system. Geothermal heat pump system is one of the most energy efficient and environmentally friendly technologies available today and it s the smart choice for saving you money and preserving our environment. Vertical Ground Loop System Horizontal Ground Loop System Ground-Water Heat Pump System Surface-Water Heat Pump System Water loop heat pump system Water loop HP system is a decentralized system using a boiler/cooling tower as a backup heat source. The heat surplus in interior areas of building can make up heat loss in outer areas of building in this system, which leads to energy saving. Meanwhile, owners can control units of individual requirements and charge separately which equates and is convenient.

Water Source Heat Pump 5 No matter what your needs, Bosch has an HVAC unit designed for you! Expert Experience: Production since 1969, 40 years of heat pump experience. Flexible: Provide heating, cooling and domestic hot water. Economical: Higher efficiency which can save 40% to 60% operating cost compared with air-source heat pumps. Ecological: Environmentally friendly refrigerant R410a, CFC free. High Quality: Use of components from renowned brands. Wide Product Range: Multiple configurations designed for different buildings and systems. High Performance: High efficiency and reliable operation Quality starts with Bosch's good design. Secure & Convenient: Intelligent unit protection features ensure easy operation, greater comfort and reliability. Tailor-made solutions: Numerous unit options satisfy your particular demand. 40 Years Experience Flexible Secure & Convenient Economical Numerous Unit Options Bosch Water - Source Heat Pump High Quality Wide Product Range Outstanding Technology High Performance Ecological I get twice the benefit from my new heat pump because it doesn t just provide heat on cold days, when it gets really hot it can cool my home as well.

6 Water Source Heat Pump Be in harmony with nature: Bosch WSHP Are you looking for a device that provides both heating and cooling for your home? Do you want a heating facility with highest efficiency? Or are you looking for a heat source for your radiant floors? You have found the right solution to these problems because Bosch water source heat pumps are what you are looking for - all you have to do is to choose. Technical Characteristics: High efficiency Optimized refrigerant system design plus most advanced scroll compressor and coaxial heat exchanger Environmentally friendly refrigerant R410A, CFC free Modular design Making it easy to enlarge if needed Intelligent Self-diagnostic function Space saving and easy transportation Occupies less space and can be moved and transported easily through doorways, elevators or hallways Flexible Various unit sizes allow for installation in almost all kinds of buildings Multiple protections Overload protection, High/low voltage protection, Water shortage protection, Anti-freezing protection etc, make the unit more reliable Nomenclature Bosch Climate 5000 GL S H - 35 D 3 A Product Sequence: A Supply 1=220~230V/50Hz/1 Phase 3=380~400V/50Hz/3 Phase Refrigerant:D:R410a H:heat pump Compressor: S:Scroll Energy Source: WL:Water loop GW:Ground water GL:Ground loop

Water Source Heat Pump 7 Features Graphic Advantage Detail Robust structure.high strength aluminum frame inside.stable groove+strong connections= Professional connections Efficient compressor.lower pressure drop.high reliability, compliance, precise.100% volumetric efficiency.perfect low temperature performance.axial flexible seal.radial flexible seal Efficient coaxial heat exchanger Low noise level User-friendly controller.high efficiency.excellent corrosion resistance.outstanding Anti-freezing capability.clean.top case insulation material.sound absorption solution.sound insulation solution.damping solution.led display.touch-sensitive button.intelligent self-diagnostic function

8 Water Source Heat Pump Operating range 55 Load water inlet/ C 50 45 40-5, 42 0, 50 35 30-5 5 15 25 Source water inlet/ C Load water inlet/ C 20 16 13 10 15 20 30 40 Source water inlet/ C Explosive View 5 4 3 5 1 Compressor 6 7 8 1 2 2 Evaporator 3 Condenser 4 Dry filter 5 Thermostatic expansion valve 6 Controller 7 Controll box 8 4-way valve

Water Source Heat Pump 9 Specification 08D1A 12D3A 16D3A 20D3A 25D3A Water Loop Condition Capacity kw 5.8 9.3 12.4 13.3 22.3 Input kw 1.40 2.42 3.16 3.40 5.80 EER - 4.14 3.84 3.92 3.90 3.84 Capacity kw 8.0 11.7 16.3 19.6 32.9 Input kw 1.80 2.97 3.90 4.20 7.80 COP - 4.44 3.95 4.18 4.67 4.21 Load Water Flow m 3 /h 1.0 1.6 2.2 2.3 4.0 Load Water Pressure Drop kpa 25.0 25.4 21.0 20.0 21.0 Source Water Flow m 3 /h 1.4 1.9 2.7 2.9 4.7 Source Water Pressure Drop kpa 14.0 39.4 12.4 25.0 23.0 Ground Water Condition Capacity kw 6.6 10.1 13.5 14.5 24.4 Input kw 1.17 2.10 2.75 2.83 5.00 EER - 5.63 4.81 4.89 5.12 4.88 Capacity kw 7.0 10.5 13.7 16.2 27.7 Input kw 1.76 2.91 3.81 4.20 7.30 COP - 3.97 3.61 3.58 3.86 3.79 Load Water Flow m 3 /h 1.2 1.7 2.3 2.6 4.1 Load Water Pressure Drop kpa 20.0 29.5 13.0 14.0 15.0 Source Water Flow m 3 /h 0.7 0.9 1.3 1.5 2.4 Source Water Pressure Drop kpa 15.0 12.9 8.1 9.0 6.0 Ground Loop Condition Capacity kw 6.3 9.9 12.9 13.7 23.7 Input kw 1.25 2.20 2.84 3.00 5.23 EER - 5.01 4.49 4.53 4.56 4.53 Capacity kw 6.8 10.1 13.5 15.8 27.0 Input kw 1.77 2.88 3.79 4.24 7.25 COP - 3.85 3.52 3.57 3.73 3.72 Load Water Flow m 3 /h 1.1 1.7 2.2 2.3 4.1 Load Water Pressure Drop kpa 28.0 29.1 12.9 13.0 14.0 Source Water Flow m 3 /h 1.4 2.0 3.2 3.1 4.9 Source Water Pressure Drop kpa 11.0 43.3 20.7 34.0 25.0 General supply V/Ph/Hz 220/1/50 380/3/50 Refrigerant - R410A Refrigerant Charge kg 1.6 1.7 1.8 2.5 4.7 Compressor Type Scroll Compressor Compressor Qty unit 1 1 1 1 1 Compressor RLA - 12.8 5.8 7.3 10.7 18.6 Compressor LRA - 54 49 58 67 100 Load Water Pipe FPT Φ(mm) DN20 DN25 DN25 DN25 DN32 Source Water Pipe FPT Φ(mm) DN20 DN25 DN25 DN25 DN32 Net Dimension Width mm 826 826 826 826 1168 Depth mm 692 692 692 692 711 Height mm 648 648 648 648 953 Net Weight kg 100 110 124 140 241 Noise Level db(a) 50 51 51 52 53

10 Water Source Heat Pump 30D3A 35D3A 45D3A 67D3A 70D3A 100D3A Water Loop Condition Capacity kw 27.7 33.2 41.3 53.8 64.4 80.1 Input kw 6.39 7.55 10.04 12.52 14.79 19.67 EER - 4.34 4.40 4.11 4.30 4.35 4.07 Capacity kw 37.3 44.0 55.9 72.4 85.4 108.4 Input kw 8.10 9.60 12.37 15.87 18.81 24.24 COP - 4.60 4.58 4.52 4.56 4.54 4.47 Load Water Flow m 3 /h 4.7 5.4 7.2 9.2 11.1 13.8 Load Water Pressure Drop kpa 39.3 30.4 33.3 39.5 39.2 39.6 Source Water Flow m 3 /h 5.5 6.4 8 10.7 12.4 15.5 Source Water Pressure Drop kpa 48.8 27.6 28.1 57.7 60.1 71.2 Ground Water Condition Capacity kw 30.3 35.0 46.1 58.7 67.9 89.4 Input kw 5.55 6.52 8.74 10.87 12.78 17.13 EER - 5.45 5.36 5.27 5.40 5.31 5.22 Capacity kw 31.2 35.5 46.7 60.5 68.9 90.6 Input kw 8.06 9.45 11.88 15.48 18.52 23.28 COP - 3.87 3.76 3.93 3.91 3.72 3.89 Load Water Flow m 3 /h 5.0 6.2 7.8 10.1 11.7 15.4 Load Water Pressure Drop kpa 44 37.5 39.6 50.3 48.3 48.3 Source Water Flow m 3 /h 2.8 3.1 4 5.4 6 7.8 Source Water Pressure Drop kpa 8 6.0 5.5 16.5 15.2 15.3 Ground Loop Condition Capacity kw 29.0 33.3 43.1 56.2 64.6 83.6 Input kw 5.73 6.74 9.08 11.76 13.38 18.04 EER - 5.06 5.06 4.75 4.78 4.83 4.63 Capacity kw 31.5 35.4 46.0 61.1 68.7 89.2 Input kw 8.03 9.44 11.88 16.22 18.53 24.68 COP - 3.93 3.75 3.87 3.77 3.71 3.62 Load Water Flow m 3 /h 5.0 5.7 7.1 9.7 11.1 14.4 Load Water Pressure Drop kpa 45 34.7 37.1 47.2 39.7 41.5 Source Water Flow m 3 /h 5.5 6.6 8.4 11.5 12.8 16.3 Source Water Pressure Drop kpa 40.8 29.0 31.6 62.3 61.7 71.6 General supply V/Ph/Hz 380/3/50 Refrigerant - R410A Refrigerant Charge kg 3.6 6.0 5.9 7.0 9.5 13.0 Compressor Type Scroll Compressor Compressor Qty unit 1 1 1 2 2 2 Compressor RLA - 20 20.7 29.3 40 41.4 58.6 Compressor LRA - 110 110 174 220 220 348 Load Water Pipe FPT Φ(mm) DN32 DN40 DN40 DN50 DN50 DN50 Source Water Pipe FPT Φ(mm) DN32 DN40 DN40 DN50 DN50 DN50 Net Dimension Width mm 1168 1168 1168 1168 1168 1168 Depth mm 711 711 711 711 711 711 Height mm 953 953 953 1778 1778 1778 Net Weight kg 252 285 315 484 560 620 Noise Level db(a) 53 54 54 55 56 61 Note: - : Load Water inlet/outlet: 12 o C/7 o C; Source water inlet/outlet: 30 o C/35 o C(Water Loop),18 o C/29 o C(Ground Water), 25 o C/30 o C(Ground Loop). - : Load Water inlet/outlet: 40 o C/45 o C; Source water inlet: 20 o C/(Water Loop), 15 o C(Ground Water), 10 o C(Ground Loop). same source water flow as in cooling mode. - RLA: Rated load current; LRA: Locked Rotor current. - Glycol will be needed when source water inlet below 3 o C, Glycol concentration: 10%~20%; - Product specification might be changed without prior notice due to product engineering evolution. pls always refer to the nameplate of equipment.

Water Source Heat Pump 11 Coefficient table Water Loop ( o C) Source water inlet 20 25 30 35 40 Chilled water outlet 5 1.039 0.775 0.984 0.884 0.930 1.003 0.872 1.138 0.810 1.302 7 1.116 0.768 1.054 0.881 1.000 1.000 0.938 1.135 0.872 1.293 10 1.233 0.765 1.171 0.878 1.105 0.997 1.039 1.129 0.969 1.280 12 1.318 0.762 1.248 0.877 1.178 0.996 1.112 1.125 1.039 1.277 15 1.457 0.759 1.380 0.876 1.302 0.995 1.225 1.125 1.147 1.270 Ground Water ( o C) Source water inlet 15 18 20 22 25 Chilled water outlet 5 0.948 0.929 0.920 1.007 0.899 1.060 0.864 1.074 0.843 1.208 7 1.031 0.926 1.000 1.000 0.976 1.057 0.927 1.071 0.920 1.201 10 1.147 0.915 1.112 0.993 1.084 1.046 1.024 1.067 1.021 1.191 12 1.224 0.908 1.189 0.986 1.161 1.039 1.098 1.067 1.098 1.187 15 1.357 0.898 1.315 0.975 1.287 1.028 1.210 1.067 1.210 1.177 Ground Loop ( o C) Source water inlet 15 18 20 22 25 Chilled water outlet 5 0.951 0.929 0.923 1.007 0.867 1.148 0.811 1.307 0.748 1.491 7 1.031 0.926 1.000 1.000 0.941 1.141 0.881 1.300 0.818 1.481 10 1.147 0.915 1.112 0.993 1.045 1.131 0.983 1.290 0.916 1.466 12 1.224 0.908 1.189 0.986 1.119 1.124 1.056 1.283 0.983 1.456 15 1.357 0.898 1.315 0.975 1.245 1.117 1.168 1.272 1.091 1.445

12 Water Source Heat Pump Water Loop ( o C) Source water inlet 15 17 18 20 22 Hot water outlet 35 0.913 0.751 0.969 0.745 0.997 0.743 1.056 0.737 1.117 0.732 40 0.906 0.839 0.963 0.839 0.991 0.836 1.053 0.836 1.120 0.836 42 0.893 0.884 0.951 0.884 0.979 0.881 1.038 0.881 1.101 0.879 45 0.876 0.955 0.931 0.955 0.958 0.953 1.016 0.950 1.078 0.950 47 0.865 1.008 0.918 1.006 0.944 1.003 1.000 1.000 1.061 0.997 50 0.849 1.090 0.900 1.088 0.926 1.084 0.979 1.082 1.038 1.079 55 0.822 1.245 0.868 1.241 0.893 1.237 0.943 1.232 0.998 1.227 Ground Water ( o C) Source water inlet 12 15 18 22 25 Hot water outlet 35 0.978 0.782 1.066 0.774 1.162 0.766 1.300 0.755 1.395 0.747 40 0.944 0.887 1.038 0.880 1.180 0.871 1.300 0.863 1.387 0.856 42 0.925 0.935 1.015 0.926 1.147 0.916 1.261 0.909 1.367 0.902 45 0.917 1.012 1.000 1.000 1.128 0.988 1.241 0.981 1.342 0.974 47 0.908 1.065 0.992 1.053 1.117 1.041 1.226 1.031 1.323 1.024 50 0.899 1.151 0.979 1.137 1.100 1.122 1.202 1.110 1.300 1.103 55 0.880 1.307 0.957 1.295 1.069 1.271 1.165 1.259 1.255 1.247 Ground Loop ( o C) Source water inlet -3 0 3 6 10 Hot water outlet 35 0.726 0.803 0.796 0.797 0.870 0.789 0.952 0.784 1.066 0.774 40 0.709 0.910 0.776 0.900 0.848 0.900 0.925 0.890 1.033 0.880 42 0.703 0.960 0.768 0.950 0.838 0.940 0.913 0.940 1.021 0.930 45 0.692 1.030 0.757 1.020 0.826 1.020 0.897 1.010 1.000 1.000 47 - - 0.750 1.080 0.820 1.070 0.890 1.060 0.990 1.050 50 - - - - 0.800 1.160 0.870 1.150 0.970 1.140

Water Source Heat Pump 13 Dimension UNIT LEFT 610 UNIT FRONT OUT OUT LOAD SOURCE ElECTRICAL CONNECTIONS IN IN F G H Model Dimension (mm) A B C D E F G H I Water pipe GW/GL/WLSH-08D1A 61.5 45 390 93.5 106.5 652 692 634 648 DN20 GW/GL/WLSH-12D3A 58.5 35 384 100.5 93.5 652 692 634 648 DN25 GW/GL/WLSH-16D3A 94.5 35 305 97.5 129.5 652 692 634 648 DN25 GW/GL/WLSH-20D3A 89 34 352 65 123 652 692 634 648 DN25 UNIT REAR UNIT LEFT ElECTRICAL CONNECTIONS LOAD OUT LOAD IN SOURCE OUT SOURCE IN C B Model Dimension (mm) A B C D E F G H I J K Water pipe GW/GL/WLSH-25D3A 1168 711 953 208 223.5 265 210 271.5 299 217 264 DN32 GW/GL/WLSH-30D3A 1168 711 953 208 202 231 287 243 367 196 282 DN32 GW/GL/WLSH-35D3A 1168 711 953 173 212 217 248 223 301 171 264 DN40 GW/GL/WLSH-45D3A 1168 711 953 174 206 219 290 219 292 174 199 DN40

14 Water Source Heat Pump UNIT REAR UNIT LEFT SOURCE OUT ELECTRICAL CONNECTIONS LOAD OUT SOURCE IN LOAD IN Model Dimension (mm) A B C D E F G H Water pipe GW/GL/WLSH-67D3A 655.5 163.5 1040 288.5 739.5 276.5 1124 151.5 DN50 GW/GL/WLSH-70D3A 660.5 125.5 1101 263.5 695.5 257 1134 118.5 DN50 GW/GL/WLSH-100D3A 623 130 1087 265 707 265.5 1171 130.5 DN50

Water Source Heat Pump 15 Electrical parameters Model Compressor Max. fuse current (A) RLA LRA GW/GL/WLSH-08D1A 220V/1Ph/50Hz 12.8 54 16 GW/GL/WLSH-12D3A 380V/3Ph/50Hz 5.8 49 10 GW/GL/WLSH-16D3A 380V/3Ph/50Hz 7.3 58 10 GW/GL/WLSH-20D3A 380V/3Ph/50Hz 10.7 67 16 GW/GL/WLSH-25D3A 380V/3Ph/50Hz 18.6 100 25 GW/GL/WLSH-30D3A 380V/3Ph/50Hz 20 110 32 GW/GL/WLSH-35D3A 380V/3Ph/50Hz 20.7 110 32 GW/GL/WLSH-45D3A 380V/3Ph/50Hz 29.3 174 40 GW/GL/WLSH-67D3A 380V/3Ph/50Hz 40 220 63 GW/GL/WLSH-70D3A 380V/3Ph/50Hz 41.4 220 63 GW/GL/WLSH-100D3A 380V/3Ph/50Hz 58.6 348 80 RLA: Rated load current; LRA: Locked Rotor current.

Bosch Thermotechnology in Southeast Asia Singapore, Cambodia, Lao PDR, Myanmar Robert Bosch (SEA) Pte. Ltd. Thermotechnology Division 11 Bishan Street 21, #04-05 Singapore 573943 Tel +65 6258 5511 Fax +65 6571 2970 Indonesia (Jakarta): Indonesia (Surabaya) PT. Robert Bosch PT. Robert Bosch Arkadia Office Park Tower F Plaza BRI, Suite 1203 7th Floor, Suite 703-705 Jl. Jend. Basuki Rahmat No. 122 Jl. TB. Simatupang Kav.88, Surabaya 60271 Jakarta 12520 Indonesia Indonesia Tel: + 62 31 5356262 Tel: +62 21 3005 5800 Fax : +62 31 5356266 Fax: +62 213005 5801 Malaysia: Robert Bosch Sdn. Bhd Thermotechnology Division No. 8A, Jalan 13/6, 46200 Petaling Jaya, Selangor, Malaysia Tel. + 60 (3) 7966 3000 Fax + 60 (3) 7958 8833 Myanmar: Representative Office of Robert Bosch (SEA) Pte. Ltd. Thermotechnology Division No. 60B, Kabar Ayer Pagoda Road Mayangone Township Yangon, Myanmar Tel. + 95 1 663616 Fax + 95 1 663616 Philippines: Robert Bosch Inc. Thermotechnology Division 28 Floor, Fort Legend Tower 3rd Ave. Cor 31st St Fort Bonifacio Global City Metro Manila 1634 Philippines Tel. +63 2 870 3888 Fax +63 2 870 3830 Thailand: Robert Bosch Limited Thermotechnology Division 287 Liberty square building, 11th floor Silom Road, Bangrak Bangkok 10500 Thailand Tel. + 66 2 639 3111 Fax + 66 2 238 4783 Vietnam (Ho Chi Minh): Vietnam (Hanoi): Robert Bosch Vietnam Co., Ltd. Robert Bosch Vietnam Co., Ltd. Thermotechnology Division Thermotechnology Division 194 Golden Building Unit 03C, 2nd floor, International Center 473 Dien Bien Phu str. W.25 17 Ngo Quyen St., Hoan Kiem Dist., Binh Thanh Dist. - Ho Chi Minh City Ha Noi Vietnam Vietnam Tel +84 (8) 6258 3690 Tel +84 (4) 3939 3119 Fax +84 (8) 6258 3692 Fax +84 (4) 3936 2899 Bosch reserves the right to change any specification, design and information without any prior notice for further improvement on quality and performance. For more information: www.bosch-industrial.com