P/N: AX Ordering Part Numbers: Controller, SAE J1939: AX Mating Plug Kit: AX Electronic Assistant : AX070502

Similar documents
with Electronic Assistant

An internal gyroscope minimizes the influence of dynamic linear acceleration on slope sensor readings.

P/N: AX Applications: Mobile Equipment, Electric Vehicles for Material Handling, Lift Platforms

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

Ordering Part Numbers:

TECHNICAL DATASHEET #TDAX09000X 12/24V BATTERY CHARGER (10A) CAN bus (SAE J1939) Safety Interlock and I/O High Efficiency, Vehicle Mount

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Electronic Control Devices The European Product Catalogue 2007

NEW. EVEN MORE data acquisition and test stand automation

TECHNICAL DATASHEET #TD1000AX DUAL SOLENOID MULTIFUNCTION VALVE DRIVER With Joystick, Potentiometer and Control System Interface P/N: DSDA-SMB Series

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Measuring Temperature withthermistors a Tutorial David Potter

Signal Conditioning Amplifier System

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

USB I/O CONTROL BOX 8 relays, 8 digital I/O lines and 8 HV inputs

NETWORK ENABLED EQUIPMENT MONITOR

Electronic Control Devices The European Product Catalogue 2007

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

PCAN-MicroMod Universal I/O Module with CAN Interface. User Manual. Document version ( )

Develop a Dallas 1-Wire Master Using the Z8F1680 Series of MCUs

JUMPFLEX 857 Series ma V ma. Transducers / Relay and Optocoupler Modules

Wahl C50 Calibrator FEATURES

Wideband USB Synthesized Signal Generator. Dynamic range 70 db, output power from -60dBm to +10dBm in 0.25dB steps

ECONseries Low Cost USB DAQ


DC Electronic Loads 8500 series

HEOL-N103-OBD, GPS/GPRS Tracking Module with On Board Diagnostic

DCS Series 1 kw, 1.2 kw, & 3 kw

MultiViu Flex 7 Data Sheet

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Install the DeviceNet Module using the following procedure:

Everything you need for protection scheme testing

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

Data Acquisition Module with I2C interface «I2C-FLEXEL» User s Guide

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

O C M III. Open Channel Flow Monitor

CPU systron S S S 250c. systron S S S 250c. CPUs to the process modules. Stand-alone PLC

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

USB-500 Series Stand-Alone, Low-Cost Data Loggers

US-Key New generation of High performances Ultrasonic device

MACTek Corporation. USB HART Interface. Users Manual

Disturbance Recoder SPCR 8C27. Product Guide

Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification

PCAN-MicroMod Evaluation Test and Development Environment for the PCAN-MicroMod. User Manual. Document version ( )

PhidgetInterfaceKit 8/8/8

Monitores Equipos Móviles Especificaciones de Producto

USB Plus+ RFID Reader Setup Guide

User's Guide. Integrating Sound Level Datalogger. Model Introduction

USB-500/600 Series Low-Cost Data Loggers and Accessories

The Universal DAQ Device. Connect and measure immediately!

MP85 / MP85DP. Data sheet. Special features MP85 / MP85DP. B en

Unidirectional Transmitter/ Receiver Units Introduction

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Signal Manager Installation and Operation Manual

Automotive CAN gateway module

Versions. Q.station Q.station T. Q.station D. Q.station DT x x

Kvaser Mini PCI Express User s Guide

PowerBox PBX 180. Installation and Users Guide

Considerations When Specifying a DC Power Supply

ELECTRONIC CONTROL UNITS. Machine Management Systems. Description. EC-MMS-1012-H 10 inputs, 12 outputs meter-in systems controller 20

CAN bus board. EB018

USB-500 Series Low-Cost Data Loggers and Accessories

Non-Isolated Analog Voltage/Current Output module IC695ALG704 provides four configurable voltage or current output channels. Isolated +24 VDC Power

Analog Servo Drive 25A8

ATB50v1 GPRS / GPS Based Fleet Management Terminal. Datasheet

PCXpocket 440. Professional Digital Audio Card. User s manual. DU IS=A

Programmable Single-/Dual-/Triple- Tone Gong SAE 800

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Alcatel-Lucent OmniPCX Enterprise Communication Server TA-MMK (MMK V2)

Intelligent RS-485 I/O expansion unit: RU-87Pn Series

FREJA 300 Relay Testing System

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

Installation manual. Generator Paralleling Controller GPC multi-line C

MLC TM Maximum Productivity and Versatility for Control without Compromise!

Temperature & Humidity SMS Alert Controller

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

AUTOMATIC NIGHT LAMP WITH MORNING ALARM USING MICROPROCESSOR

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

RUDAT Key Features. Mini-Circuits P.O. Box , Brooklyn, NY (718)

SL Series AC and DC Electronic Loads

Technical Data Sheet. 3DLevelScanner

DS1104 R&D Controller Board

Brushless DC Motor Controller Product Specification Assembly 025F0129

Application Note. Line Card Redundancy Design With the XRT83SL38 T1/E1 SH/LH LIU ICs

Combi switchbox with integrated 3/2 way pilot valve

CPU ARM926EJ-S, 200MHz. Fast Ethernet 10/100 Mbps port. 6 digital input 2 digital open-drain alarm output

UniPi technical documentation REV 1.1

IR-PRO IR-PRO. Operation Guide. Professional Infrared Code Capture System

[F/T] [5] [KHz] [AMP] [3] [V] 4 ) To set DC offset to -2.5V press the following keys [OFS] [+/-] [2] [.] [5] [V]

sigpod Press ASSEMBLY PRESS-FIT MONITORING SYSTEM BENEFITS FEATURES

How To Use A Watt Saver On A Microcontroller (Watt Saver) On A Cell Phone Or Mp3 Player

1.44 kw Programmable DC Power Supplies XLN Series

User and installation manual

SCXI CHANNEL ISOTHERMAL TERMINAL BLOCK

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual

Transcription:

TECHNICAL DATASHEET #TDAX181000 TC/Analog Inputs to CAN Controller 4 Thermocouple, 7 Analog & 3 Signal Inputs 12 Vdc, 24 Vdc, 48 Vdc 2 CAN (SAE J1939) with Electronic Assistant Description: The TC/Analog Inputs to CAN Controller receives inputs from engine coolant, fuel and differential pressure sensors, engine temperature sensors, thermistors as well as thermocouples and is networked to a SAE J1939 based control system. Seven +5V references (10 ma) are provided to power the sensors. The 2 CAN ports are isolated from signal inputs and thermocouple inputs. P/N: AX181000 Using the Electronic Assistant programming tool, the user can select the desired inputs from the following signal options. 4 Thermocouples (Type J, K or T) 7 Analog Signals (0-5 V, 0-10V, 0-20 ma, 4-20 ma) 3 Universal Signal Inputs (0-5V, Thermistor, 0-20 ma, 4-20 ma, PWM, Frequency or Counter, Discrete) A rugged power supply interface accepts 12 Vdc, 24 Vdc or 48 Vdc nominal for battery powered machine applications. The unit carries an IP67 rating. It carries a CE mark. The rugged enclosure with four 12 pin Deutsch IPD connectors is suitable for diesel engine environments. It operates from -40 to 85 C (-40 to 185 F). Applications: power gen set engine control systems oil and gas equipment automation marine engine applications off-highway machine automation Ordering Part Numbers: Controller, SAE J1939: AX181000 Mating Plug Kit: AX070123 Electronic Assistant : AX070502

Technical Specifications: Specifications are indicative and subject to change. Actual performance will vary depending on the application and operating conditions. Users should satisfy themselves that the product is suitable for use in the intended application. All our products carry a limited warranty against defects in material and workmanship. Please refer to our Warranty, Application Approvals/Limitations and Return Materials Process as described on www.axiomatic.com/service.html. Block Diagram Control Logic From the software perspective, the AX181000 consists of a set of internal functional blocks, which can be individually programmed using the Simulink model to achieve the required system functionality. The functional blocks include: 1-7 analog inputs (voltage or current); 1-3 signal inputs; 1-4 Thermocouple inputs; 1-14 Can Transmit messages; and 1-14 DM1 messages. The model operates with Simulink for easy graphical programming in a model based simulation and development environment. The functional blocks have been readily implemented into the Simulink model. With the Simulink model it is possible for a customer to easily modify functional blocks to produce their own custom software. For example, input and CAN message connections can be altered, transfer functions can be added between inputs and CAN messages and initial values for functional block set points can be configured. The Axiomatic Hardware Interface Library (HWIL) is provided for this purpose. For simulating models using Axiomatic HWIL, licenses for Simulink and Stateflow are required. Code generation requires the Simulink Coder license in addition. Inputs Power Supply Input Protection Inputs Analog Grounds 12 Vdc, 24 Vdc or 48 Vdc nominal (9 60 Vdc power supply range) Reverse polarity protection Overvoltage protection is up to 120 V. 4 Thermocouple Inputs 7 Analog Signal Inputs (0-5 V, 0-10V, 0-20 ma, 4-20 ma) 3 Universal Signal Inputs (0-5V, Thermistor, 0-20 ma, 4-20 ma, PWM, Frequency or Counter, Discrete) User programmable (Refer to Table 1.0.) Inputs and Power are isolated from CAN. 10 provided TDAX181000 2

Table 1.0 Inputs User Programmable Options Thermocouple Inputs Reads up to 4 Type J, K or T thermocouple inputs Full channel to channel isolation and isolation from CAN line, other inputs and power supply Cold junction compensation is provided. Thermocouple input resolution is 0.1 C. Accuracy is +/-1 C throughout the entire range of the thermocouple input. 4 shield connections are provided. Analog Input Functions Voltage or Current Input Voltage Input 0-5 V (Impedance 200 KOhm) 0-10V (Impedance 150 KOhm) Current Input 0-20 ma (Impedance 125 Ohm) 4-20 ma (Impedance 125 Ohm) Digital Input Functions Discrete Input, PWM Input, Frequency Input Digital Input Level 12V or 24V Threshold: Low <1.5 V High >3.5V PWM Input 0 to 100% 100 Hz to 10 khz Note: Universal Inputs 2 and 3 share a timer in Frequency and PWM mode, thus they should be set on same frequency range. Frequency/RPM Input 0.5 Hz to 50 Hz; 10 Hz to 1 khz; or 100 Hz to 10 khz Digital Input Active High with pull-up (input 8-5kΩ, input 9 and input 10 1kΩ) Input Accuracy Input Type Input Range Accuracy Voltage 0-5V 0.1% 0-10V 0.1% Current 0(4)-20mA 0.1% Frequency 0.5Hz-50Hz 0.2% 10Hz-1kHz 0.17% 100Hz-10kHz 0.17% PWM Low Frequency 0.08% High Frequency 0.41% Table 2.0 - Input accuracy Input Resolution Outputs CAN bus Reference Voltages General Specifications Microprocessor Typical Quiescent Current Response Time Control Logic Communications User Interface 12-bit SAE J1939 7 provided +5V +/- 0.5% (10 ma) STM32F205 32-bit, 512 kbyte flash memory 84 ma@12vdc; 52 ma@24vdc 3 msec. Standard embedded software is provided. 2 Isolated CAN ports (SAE J1939) (CANopen on request) 300 Vrms The Electronic Assistant, P/N: AX070502, for Windows operating systems comes with a royalty-free license for use on multiple computers. It includes an Axiomatic USB- CAN converter to link the device s CAN port to a Windows-based PC. The setpoints can be viewed and programmed using the standard J1939 memory access protocol through the CAN port and the PC-based Axiomatic Electronic Assistant. The EA can store all setpoints in one setpoint file and then flash them into the unit in one operation. The setpoint file is created and stored on disk using a command Save Setpoint File from the EA menu or toolbar. The user then can open the setpoint file, view or print it and flash the setpoint file into the controller. TDAX181000 3

Operating Conditions Storage Temperature Protection Compliance Weight Packaging Electrical Connections -40 to 85 C (-40 to 185 F) -55 to 125 C (-67 to 257 F) IP67 CE mark 1.30 lbs. (0.59 kg) High Temperature Nylon housing, Deutsch IPD P/N: EEC-5X650B 4.03 x 4.25 x 1.68 inches 102.44 x 107.96 x 42.67 mm (L x W x H including integral connector) Refer to the dimensional drawing. 48 pin Deutsch IPD connector P/N: DT13-48PABCD-R015 Mates with: Deutsch IPD P/N s DT06-12SA Plug, DT 12 Way A Key DT06-12SB Plug, DT 12 Way B Key DT06-12SC Plug, DT 12 Way C Key DT06-12SD Plug, DT 12 Way D Key Network Termination For the electrical pin out, refer to Table 3.0. It is necessary to terminate the network with external termination resistors. The resistors are 120 Ohm, 0.25W minimum, metal film or similar type. They should be placed between CAN_H and CAN_L terminals at both ends of the network. TDAX181000 4

Dimensional Drawing Notes: Electronic Assistant is a registered US trademark of Axiomatic Technologies Corporation. Mathworks, Simulink, Stateflow and MATLAB are registered trademarks of The MathWorks, Inc. Simulink Coder is a trademark of the The Mathworks, Inc. Form: TDAX181000-04/17/15 TDAX181000 5