Handy type 10-channel logger midi LOGGER GL200A Sales Manual GRAPHTEC

Similar documents
USB-500 Series Low-Cost Data Loggers and Accessories

USB-500 Series Stand-Alone, Low-Cost Data Loggers

USB-500/600 Series Low-Cost Data Loggers and Accessories

Wireless Data Logger. Collect, Manage and Monitor Your Valuable Data via Wireless Communication. Register and Manage Remote Units by Groups

4-Channel Thermometer / Datalogger

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

USB-500/600 Series Low-Cost Data Loggers and Accessories

Temperature & Humidity SMS Alert Controller

User's Guide. Integrating Sound Level Datalogger. Model Introduction

User Guide. Temperature and Humidity Datalogger. Model 42280

Easy! Smooth! GP/ST-3500 Series->GP4000 Series Replacement Guidebook

NEW. EVEN MORE data acquisition and test stand automation

SNMP Web Management. User s Manual For SNMP Web Card/Box

Embest DSO2300 USB Oscilloscope

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Simplify Data Acquisition with a Built-in LXI Web Server

Standard Cables (Without electromagnetic brake, with electromagnetic brake) CC010ES-2. 1 m CC020ES-2. 2 m CC030ES-2. 3 m CC050ES-2.

Data Loggers for Real Time Temperature Monitoring - WiFi

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

Data Logging Solutions from Lascar Electronics

AXIS 262+ Network Video Recorder

Hand-held thermometer Model CTH7000

USER MANUAL V5.0 ST100

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

KACO-monitoring. onlinecomponents.com. Integrated monitoring available. Monitor up to 32 inverters per prolog. Reliable and accurate data

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

User Manual.

Current Monitoring Kit QUICK START GUIDE

Current Monitoring Kit

Quick Connect. quick - simple - efficient.

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

NETWORK ENABLED EQUIPMENT MONITOR

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

FC6 FOOT CONTROLLER OWNER S MANUAL

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Dash 18X / Dash 18 Data Acquisition Recorder

PD 100A. Printing data system

A-307. Mobile Data Terminal. Android OS Platform Datasheet

Electronic Control Devices The European Product Catalogue 2007

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

SNC-VL10P Video Network Camera

1. SAFETY INFORMATION

Field Service Application

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

The new 5.7 standard model

All Analog Outputs, voltage/current 20mA 35mA 5mA 48mA/30mA* *If the analog outputs are not configured, then subtract the higher value.

Poor quality welds Machine downtime High maintenance costs Lost revenue

How To Use A Sim Sims 2.2 (Blackberry) With A Sims 3 (Blackintosh) And Sims 4 (Blackburn) (Blackford) (Whiteford) For A Long Time (Blackwood) (Blue

Embedded Display Module EDM6070

1.44 kw Programmable DC Power Supplies XLN Series

Point of view HDMI Smart TV dongle Mini RF Keyboard

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

SMS GSM Alarm Messenger

Multi-Range Programmable DC Power Supplies 9115 Series

5000V Graphical Megohmmeter Model 5070

PU-USBX. USB over Ethernet Extender OPERATION MANUAL

Autos Limited Ghana Vehicle Tracking Business Proposal

Repeaters and Mimics Data Sheet

Datalogger Graph Software Help

POCKET SCOPE 2. The idea 2. Design criteria 3

NetProbe Lite. Web Based 8 Channel Sensor Collector. User Manual. Version 1.2

70 C 20 C. RS232/422/485 2-to-1 Server. Ethernet RS sub-link. 2-to-1 transparent server. Other Panel. 2-to-1 transparent server. Ethernet.

Model POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

AR VOICE LOGGER USER S MANUAL. Version1.0.0

Wireless Data Logger Monitoring Systems

User s Manual. Management Software for ATS

OZW30. Central Unit SYNERGYR

Leaf River Outdoor Products Vibrashine, Inc. P.O. Box 557 Taylorsville, MS (601) FAX (601)

UniOP epad33 and epad33t

Controlers. Controler

V350-TA24 V350J-TA24.

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

User s Guide DDS-3X25 USB ARBITRARY FUNCTION GENERATOR

PRODUCT LIST Facility DDC Access WebXL DDC

PMS. Energy management and monitoring software. Installation and operation instructions

MI4 - Operator Panel : Engineering

V350-R34 V350J-R34. npn inputs pnp inputs

Wahl C50 Calibrator FEATURES

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Weather Capture Software Guide Version 1.4 Revision: June

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers.

FIREDEX Conventional Fire Panels

Electronic Control Devices The European Product Catalogue 2007

EXTERNAL DIMENSIONS AND PARTS

(Simulated Images) Intelligent Monitoring Software IMZ-NS101 IMZ-NS104 IMZ-NS109 IMZ-NS116 IMZ-NS132. sony.com/security

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

User s Guide DSO-2150 USB PC Based Digital Oscilloscope Operation Manual

OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher

OPERATOR PANEL OP7/DP LC DISPLAY, BACKLIT LED 4 LINES, 20 CHARACTERS/LINE, SIMATIC S7, M7, PROFIBUS-DP 1.5 MBAUD UL/CSA-LISTED

Digital input modules

User's Guide Integrating Sound Level Datalogger Model

Dash 8Xe / Dash 8X Data Acquisition Recorder

Transcription:

Handy type 10-channel logger midi LOGGER GL200A Sales Manual GRAPHTEC

The midi LOGGER GL200 has evolved 10 channels compact data logger No only for temperature but also for voltage fluctuation measurement > 10-channel isolated multi-function input > Corresponding to max. 10ms sampling NEW > Save data to USB memory directly / The USB memory can be replaced during measurement NEW > Safety measurement using internal flash memory > Eye-friendly 3.5 TFT color LCD

Multi-function Input Voltage/Temperature/ Humidity/Logic/Pulse Features 10ch Isolated input M3 screw clamp terminal Eye-friendly 3.5 TFT color LCD >Easy PC connection >Direct data recording to USB memory Internal flash (3.5MB) memory holding data even after power off Compact size and weight 212 X 122 X 41mm Approx. 480g GL200A Easy operation NAVI button Ergonomic design/ Operability Same operability as portable terminal

10 channel isolated multi-function input >Use multi-channel isolated input method not receiving the influence among channels by various type of input signal even though it s a small size. No need to worry about wire. >Available to measure different phenomena such as multi-function of temp/ humid/voltage/pulse/logic for input signal, temperature, humidity, and voltages, etc. Temperature Humidity Voltage Pulse Logic Option Humidity sensor B-530 M3 screw clamp terminal Use M3 screw clamp terminal (small type) for input. Available to wire easily and certainly with ring (O)/fork (U) crimp Ring crimp Fork crimp

Corresponding to max. 10ms sampling NEW The GL200 have been used with many customers mainly for temperature measurement. We received the requirement from the customers to increase the sampling speed a little, so we provide that the 10ms max. sampling speed can be selected when number of channels is limited. Sampling speed 10ms 20ms 50ms 100ms 1s Available number of channels 1 2 5 10 10 Measurement object Voltage Temperature X X X X X X X *The humidity measurement uses the volt range of 0-1V with scaling function, so the sampling speed for the humidity measurement is same as volt measurement.

Available for USB memories/easy PC connection (2USB ports loaded) 1.Connect USB flash memory to GL200 to record data directly Copy measured data of internal memory to USB flash memory 2.Connect USB flash memory to PC to display data with EXCEL 3. Available to PC measurement if connecting between GL200 and PC with USB cable. Also transfer internal memory data to PC USB memory 2. To PC 1. Direct recording 3. PC measurement Data transfer USB Cable For USB memory For PC connection

For long time measurement >Standard internal recording media with flash memory Available to hold data after turning the power off >The USB memory can be replaced even during measurement. During he replacement, measured data is stored in the buffer memory for 5 minutes maximum. NEW >The measured data file is automatically closed in every 1 minute, so the data is protected against accidental power off. USB memory can be replaced during measurement 3.5MB internal flash memory Available time for data recording (at the time of 10ch measurement, pulse & logic off) *1: Max. no. of channels that can be specified is 1. *2: Max. no. of channels that can be specified is 5. Recording interval (sampling speed) 10ms *1 50ms *2 100ms 200ms 500ms 1S 10S 3.5MB internal flash memory About 4h About 4h About 8h About 20h About 1.8days About 18days About 2.4h 256MB USB flash memory About 7days About 12daysAbout 13days About 26days About 65days About 130days About 1300days

Eye-friendly 3.5 TFT Color LCD Adopt eye-friendly 3.5 TFT color LCD, which confirms setting of measurement conditions or measurement waveform, digital value Adopting clear and ease-to-read color layout, the visibility is improved

Easy operation (Navigation screen) NAVI Press button to display the description of each operational button on LCD monitor. Easy operation without having instruction manual

Easy operation to set and display Measurement conditions are itemized user-friendly setting screen Quick settings make sampling (recording interval) and waveform display division (zone) change quickly Available to display the current value and max and min value up to now Available to display and compare current and past data when pressing REVIEW button during recording Current data Past data

Battery pack (Option) Battery life: Approx. 6 hours Useful for battery drive at the instant stop of AC power or measurement at a site without power. Battery pack B-517 Identifiable battery indicator

USB PC card drive mode Available to recognize GL200A internal memory as external recording media for PC. Available to transfer data files by drag and drop on the window easily. USB

PC software standard features midi LOGGER Software PC application software is attached as standard product in order to measure right after your purchase. This software supports to make reports such as waveform observation with PC or excel conversion of recording data, and so on. Easy-to-use operation by GUI

User-friendly interface The interface employs intuitive icons to suit all ability levels. Just clicking the icons, you can change the waveform display Displays plot marks at the sample points of a waveform Opens a sub-screen Cursor A Cursor B Input comments Expands the time axis Shrinks the time axis Moves down the position of the selected channel Moves up the position of the selected channel Shrinks the Y axis of the selected channel Expand the Y axis of the selected channel There are now only five settings screens. The input waveform is displayed on all screens to illustrate the impact of each modification in real time.

Variety of measurement displays A wide variety of screen configurations are provided: Y-T, X-Y, digital, metering and report display. Measurement display Y-T Meter Direct Excel transfer Digital Data replay display Direct data transfer to Excel with 100 ms sampling is possible Y-T display X-Y display Digital display NEW

Multiple units can be controlled together NEW Using the midi LOGGER software, max. 10 units of GL200A can be controlled together. Also this software is compatible with the GL800. Max 100 ch or 10 units USB ID can be set the GL200A side USB cable USB hub Selecting the model name (GL200A / 800) Each unit can divide the display channels to 4 groups max. (G1 to G4) Group can be set in each channels at APM setting window

Useful functions During measurement, Logic/Alarm condition display function and the protection function using password are provided. Also, after finish data replay, the CSV batch conversion display and data search function are provided for more convenient operation. In the spot sample rate for CSV conversion, user specify rate is newly added, so the customer can specify their own spot sample rate. NEW Any spot sample rate can be specified

midi LOGGER GL200A Specifications Item Number of channels Input method Display unit Description Analog 10ch, Logic 1ch, Pulse 1ch (RPM, Instant, Count), Alarm output 1ch Isolated input 3.5 TFT color LCD DC voltage(20mv to 50V, 1-5V) Input type Temperature (Thermocouple: K, E, J, T, N, R, S, B, W) Humidity (Used an optional humidity sensor) Recording interval Internal memory External recording medium PC I/F Display Power supply Dimensions, weight Accessories 10ms to 1h (there is a limitation on no. of channels for 100ms or faster sampling, Volt range only) 3.5MB (Flash memory) Hold data after put off the power USB memory Enable to save data directly USB Waveform display/ Digital display switching, Review display AC adapter, DC drive, battery pack (Battery life: 6 hours with optional B-517, depending on our criteria specified) 194 122 41mm 480g AC power adapter, cable 1set, CD-ROM 1pc(PC software PDF user manual), quick start guide

Differences between GL200 and GL200A GL200A GL200 Main unit Max. sampling (10, 20, 50, )100, 125, 200, 250, 500ms 1, 2, 5, 10, 20, 30s 1, 2, 5, 10, 20, 30min 1h (for volt range only) 100, 200, 500ms 1, 2, 5, 10, 20, 30s 1, 2, 5, 10, 20, 30min 1h USB memory replacement during meas. YES NO Application Software Multiple unit connection (possible to mix with GL800) YES NO Icon key function YES NO CH group function YES NO Spot sample Provided : Any spot sample can be specified Provided Direct EXCEL : max. sample 1Provided s : max. sample 100 ms Provided : Spot sample rate can be selected from fixed settings

Comparison with Competitive Commodity Advantage GL200A for 優位点 GL200A GL200A DaqPRO 5300 by F XL100 by Y 8420-50 by H Isolation M3 screw terminal Differential inputs screw terminal Isolation screw terminal Isolation screw Inputerminal method weight 194 122 41 480g 100 x 28 x 182 450g 155 55 155 800g 234 x 52 x 170 Dimensions 1.4kg and 3.5 TFT color LCD 64 X 128 pixels LCD 3.5 TFT color LCD 5.7 STN color Screen LCD Input type Voltage, thermocouple, humidity Voltage, Current, Thermocouple, RTD, PT100 Voltage, temperature, resistance thermometer bulb Voltage, temperature, resistance thermometer bulb, humidity Number of channels Analog 10ch Pulse 1ch, Logic 1ch Alarm output 1ch Analog 8ch Pulse 1ch, Logic 1ch Alarm output 1ch Analog 8ch Pulse 1ch, Logic 2ch Alarm output 4ch Analog 8ch Pulse 4ch, Logic OP16ch Alarm output OP 16ch sampling 10ms/1ch At 10ch:100ms 4000S/s 1ch, Maximum Temperature sampling rate is 1/s 100ms/8ch 100ms/8ch 16bits 16bits A/D resolutions 16bits 16bits 20mV to 50V, 1 to 5V/F. S. 0V to 10V/F. S. 100mV to 50V, 1 to 5V/F. S. 100mV to 60V, Input 1 tovoltage 5V/F. S. 3.5MB flash memory 512kB Internal memory 16MB 32MB PC interface USB1.1 USB memory (direct recording) USB1.1 LAN, USB1.1, RS232C, RS- 485, CF/SD card, USB memory (copy only) LAN (10BASE), RS232C (modem) CF card Power supply AC adaptor, DC drive Battery pack: Approx 6 hours drive AC adaptor Battery pack: Approx 40 hours drive AC adaptor Battery pack: Approx 8 hours drive AC adaptor, DC drive Battery pack: 2.5 hours drive