DR 150 DR 300 DR 500

Similar documents
SHHH AIR COMPRESSOR Model Nos. SHHH2 - SHHH2/9 - SHHH3/9 - SHH3/24

accidents which arise due to nonobservance and the safety information herein.

PC1131 Electric Air Compressor

PC1130 Electric Air Compressor

Compressor Service & Maintenance Manual

A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps

Trouble Shooting BD & TW Compressor Systems 12 and 24 Volt

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

SILENT AIR COMPRESSOR

OPERATING & MAINTENANCE AIR COMPRESSOR RANGER 35 INSTRUCTIONS. Part No:

TITAN Fuel Tanks. INSTALLATION INSTRUCTIONS G e n e r a t i o n V

STAINLESS STEEL TANK TABLE OF CONTENTS TROUBLESHOOTING... 1 TESTING WATER TEMPERATURE... 3 TANK & JACKET ASSEMBLY... 4.

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

2 HP / 4 GALLON AIR COMPRESSOR OWNER'S MANUAL

20 GALLON WET DRY VACUUM

CTV-1500 Cooling Tower Vacuum Operating & Maintenance Manual

123 Industrial Loop Road Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS

MAINTENANCE INSTRUCTIONS FOR THE CLEAN-FLO CONTINUOUS LAMINAR FLOW INVERSION / OXYGENATION SYSTEM

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

12V Portable Diaphragm Compressor Operating and Maintenance Instructions

Not required for most applications Not required for most applications High pressure ( provided) High pressure ( provided)

Dehumidifier Users manual. For Models: DH45S DH65S

Read This Before Operating The BaseHit

COMPRESSED AIR DRYER

Safety, Operation and Maintenance Manual with Parts List

Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

IMPORTANT SAFETY RULES TO FOLLOW

PANTHER OPERATING & MAINTENANCE INSTRUCTIONS

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

CARING FOR YOUR WATER HEATER

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

VOYAGER 570G. 744A Sprayer Control

INSTALLATION & OPERATING INSTRUCTIONS

Digital Photo Picture Frame. Operation Manual

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR İ-COLD Rev. 00

NITROUS TRANSFER PUMP INSTRUCTIONS

MODEL INSTALLATION INSTRUCTIONS

GeniJet Pipeless Motor Spa Installation

OPERATING INSTRUCTIONS. Shortening Filter Model No. 99-A, 102-A, & 107-A Series LIMITED WARRANTY PRODUCT SPECIFICATION

15GAL STEEL OIL DRAIN WITH 110V PUMP

The Storm 20-Gallon Wet/Dry Vac

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

Belt Driven Compressors

ClearView 100. Instruction Manual

Technical Guide 08/15/14

OWNER S MANUAL DRAINVAC ATOMIK PRINTED APRIL

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N

Customer Support

Installation Instructions S

Arctic Leash Instruction Manual Alaskan Products Company LLC.

T15 AIR CONDITIONER INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...

Bottom Loading Water Dispenser

D I G I T A L C L A M

Wilo SP Series Submersible Sump Pumps ECS. ECS ECS ECS Installation and operating instructions

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800) Internet Address:

Chapter 7 Hydraulic System Troubleshooting

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

AFE424 SERVICE PARTS

OWNER S MANUAL BIG BEAR VORTEX FAN MODEL #BB-1 INTRODUCTION OPERATION SAFETY SERVICE WARRANTY CONTACT SPECIFICATIONS TROUBLESHOOTING

FJ2. 2 Ton Trolley Floor Jack Assembly & Operating Instructions

FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL

7.1. Part Lists. Hardware Insertion Machine. Instructions. Instructions

INVERTER GENERATOR OWNER S MANUAL FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE.

- Do not immerse cords, pump or any electrical wire or device in water or other liquid.

Trouble Shooting. Pump

Model 1210C Battery Powered Pump Shown. Description

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

MODEL G300 BRAKE BLEEDER

INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Multi-Pitch Pitching Machine USER MANUAL

Your safety and the safety of others are very important.

INSTRUCTION MANUAL FOR RECREATIONAL REFRIGERATOR/FREEZER MODEL

SBC90. Abrasive Blast Cabinet Assembly & Operating Instructions

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

National- Spencer Inc.

Error Codes: 02F. Model: (110. = Whirlpool) S/N: CSP Type: 199-AKP 705/WT. Sears Kenmore/Whirlpool Front Load Washer

Operations and Maintenance Manual

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION

Andersen Electric Window Opener for Andersen Awning and Roof Windows

Instructions For SF 6 Refill Kit


OTF Oil Fired Pool Heater

OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER

Oil and Coolant Circulating Heating System. Model - OCSM

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Operator: Save these instructions for future use!

4 Gallon Air Compressor Assembly & Operating Instructions

SunMaxx Solar Filling Station Operating Instructions

Unit 24: Applications of Pneumatics and Hydraulics

BLAST CABINET ABRASIVE Rev SAVE THESE INSTRUCTIONS. Important Safety Instructions are included in this manual

Transcription:

DR Series Air Compressors Instruction & Maintenance Manual Thank you and congratulations on your purchase of the SUPER SILENT air compressor, the leader in the industry of portable silent air compressors. This is a quality-built, highly efficient compressor, which, if properly used and maintained, will perform to your full satisfaction for many years to come. All Super Silent air compressors are virtually soundless and are totally automatic. Each unit includes a tank pressure gauge, line pressure gauge, line pressure regulator, moisture trap/filter, safety valve, air-intake filter and a handle for balanced carrying. Please follow the instructions carefully to guarantee trouble-free operation. DR 150 DR 300 DR 500 The DR 150 features a 1/5-hp motor, the DR 300 a 1/3-hp motor and the DR 500 a 1/2-hp motor.

PRE-OPERATING INSTRUCTIONS Remove your Super Silent compressor from the packaging. Read all of the literature enclosed and inspect the unit for possible shipping damages. Then remove the white shipping plug from the hole in the top section of the pump. The Air-Intake Filter and the oil bottle spout are in a plastic bag hanging from the braided metal air hose coming out of the side of the pump. Attach the spout to the oil bottle. Pour the oil into the open hole. Stop when the oil level reaches the middle of the oil sight glass, which is located on the side of the pump. Then place the Air-Intake filter into the open hole. (See illustration below) Connect desired air hose and selected tooling to the threaded port on the Filter Regulator marked OUT.

OPERATING INSTRUCTIONS 1. Make sure the Air-Intake Filter has been installed (See Pre-Operating Instructions). 2. Make sure that the automatic ON/OFF Pressure Switch is in the OFF position (or turned fully counterclockwise). 3. Plug the cord into 110 Volt Grounded outlets. Unit should be grounded because in the event of an electrical short, grounding reduces the risk of electric shock. The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances. If it is necessary to use an extension cord, DO NOT USE a common household cords. Use a HEAVY- DUTY extension cord. Not using a HEAVY-DUTY extension cord will cause loss of power to the compressor, and possibly damage the electrical components. NOTICE: TAMPERING WITH THE POWER CORD OR GROUNDING TERMINAL WILL VOID WARRANTY. 4. Turn the automatic ON/OFF Pressure Switch to the ON position by turning the knob clockwise until it stops. This pressure switch has been set to automatically start and stop at the correct PSI levels. Leave it in the ON position until you need to turn off your compressor. To do this, simply turn the knob down counter clockwise. If the electrical power is interrupted while the compressor is in operation and it fails to restart after the power comes back on, turn the knob to the OFF position. This will release any pressure in the line and enable the compressor to restart. 5. After the compressor has run for a complete cycle and shuts off, the Pressure Regulator can then be adjusted to your desired setting. Simply lift the knob until it unlocks, and then turn it clockwise to increase the pressure, or counter clockwise to reduce it. Watch the pressure gauge close to the regulator to measure the pressure needed. NOTICE: A standard feature on your compressor is the Safety Relief Valve. The Valve opens automatically if the tank pressure goes beyond a safe level. DO NOT ATTEMPT TO ADJUST OR REMOVE THIS DEVICE. MAINTENANCE AIR INTAKE FILTER: The air intake filter must be kept clean to permit easy airflow into the compressor. Filters that have become dirty, oily, or clogged can be cleaned thoroughly in a detergent soap and water solution or replaced. Cleaning or replacing the Air Intake Filter, under normal operating conditions is necessary every 3 to 6 months. Never operate the compressor without an Air Intake Filter in place. MOISTURE TRAP: If used properly, the moisture trap (which is built into the Filter/Regulator) will trap moisture and dirt particles before releasing air into the line. Periodic checks for moisture and traces of oil should be done on a routine basis by looking through the clear bowl attached to the underside of the Filter/Regulator. When moisture and/or oil traces are detected, they can be removed by pressing up the valve core, which is located at the bottom of the bowl. The air pressure will blow the moisture and oil trace out through the valve core. Should it become necessary to remove the clear bowl for cleaning. CAUTION should be taken that there is no air pressure in the bowl at the time it is unscrewed. OIL LEVEL: Periodically check the oil level at the oil sight glass. Should the level drop towards the lower edge of the glass, add the necessary quantity to bring the level up to the middle of the oil sight glass. (See illustration in Pre-Operating Instructions). It is strongly recommended to change the oil after every 150 hours of operation or when the oil is discolored. To hcange the oil, remove the air intake filter and tilt the unit until all oil has drained.

NOTICE: The oil supplied with your compressor is a highly researched synthetic grade oil. Do not mix or substitute the oil in your compressor with other available brands. Use of oil not specified by the manufacturer will result in compressor breakdown and void the limited warranty. PRESSURE TANK: The air tank should be checked for water daily. Unplug the unit and release all air in the storage tank by opening the drain plub on the lower side of the pressure tank. Tilt the unit towards the plub to allow water to drain. The air hose and other accessories should also be drained on a regular basis. COMPRESSOR SAFETY TIPS Carefully inspect the hoses, fittings and overall appearance before each use. Always operate the compressor on a level surface. Periodically check the oil level at the oil sight glass. Use only properly grounded outlet that will accept 3 pronged plugs. Do no operate the compressor with a damaged cord. Keep the compressor free of dust, dirt, and paint. This will prolong Air Intake operation and prevent clogging for Safety Relief Valve. Use only recommended air handling tools and attachments that are acceptable for pressures rated for this company. Adjust the pressure regulator according to your compressor with other available brands. Any attempt to use oil differenty from that specified by the manufacturer will result in compressor breakdown and void the Limited Warranty. Do no direct the air stream at your body. To reduce the risk of ELECTRIC SHOCK, do no expose the unit to rain or water while in use. Never attempt to service the compressor while it is plugged into an electrical outlet. Avoid direct contact with surface while operating high temperatures may be present. Use only factory authorized parts. Always store your compressor in a clean and dry environment when not in use. Make sure all air pressure has been released from the system. WARNING: ANY ATTEMPT TO SERVICE YOUR COMPRESSOR BY REMOVING THE COMPRESSOR SHALL OR TERMINAL BOX COVER, TAMPERING WITH THE PRESSSURE SWITCH SETTING AND/OR GROUNDING PLUG WILL VOID THE LIMITED WARRANTY, AND MAY MAKE THE COMPRESSOR UNSAFE TO USE. TROUBLE SHOOTING GUIDE

TROUBLE CAUSE REMEDY No Power Check outlet voltage, fuse and circuit breakers Bad cord connection for incorrect extension cord Check cord connection for visible damage- if using an extension cord, make sure it is UL approved, and it s heavy duty and grounded Compressor will not run Holding tank is fully pressurized Use your equipment to lower pressure in tank Thermal overload protection has tripped Wait 15 minutes and try starting again if this was the cause; make sure compressor is in well ventilated area: check installation leaks; set the regulator s pressure minimum required for your equipment Air pressure regulator not set Reset Air-Regulator to pressure required by your equipment properly Air-Intake Filter clogged or not Clean Air-Intake Filter or replace Compressor runs but will not supply air installed Extensive leak Install Air-Intake Filter on suction tube or hole (see machine set-up); check all fittings, connections and equipment, close your pressure regulator all the way (counterclockwise) if pressure in tank builds up, leak is in your installation Rattling noise during Compressor motor touching shell Operate on level surface check oil level and adjust if it s necessary operation Milky oil in compressor Oil has been contaminated with moisture or other foreign matter Change oil Oil needs to be changed every 150 hours; use only original oil from Silentaire Technology Air-Tank not holding pressure when compressor is not running Faulty Check Valve Disconnect pressure hose at pump and check for leaking back into pump Clean or replace the check valve Spray all connections and manifold with soap solution and reseal or replace leaking parts No equipment connected to Connect equipment No air pressure shown on regulator gauge compressor Regulator has not been adjusted Lift knob and turn clockwise until gauge shows required pressure Gauge should be set at minimum level required by your equipment Oil level is incorrect Fill unit with oil unit MID level. Make sure compressor is well ventilated area. Compressor operates very hot Non-Ventilated Area Undersized model Duty cycle of compressor should not exceed 50% - if pump is on for 1 minute it should stay off 1 minute Leaks in installation Make sure no leaks are present. The setting on the pressure regulator must be at your equipment minimum level.

Exploded View for Models DR 150, DR 300 and DR 500

EXPLODED VIEW MOTOR E59 DR 150

EXPLODED VIEW MOTOR E88- DR300

EXPLODED VIEW MOTOR AE2415 OLDER MODEL DR-500

EXPLODED VIEW MOTOR T2134 NEWER MODEL DR500

Parts List Super Silent DR-Series Part # Part Description Part # Part Description B0035 Nut M6 UNI 5587 C0059 Fitting Extension M1/4 -F1/4 C0001 Gasket Intake-Valve E59 C0061 Bolt M8x15mm C0002 Valve Plate cpl. E59 C0062 Washer M10x20mm UNI 6592 C0003 Gasket Exhaust-Valve E59 C0063 Fitting L M1/4 -F1/8 C0004 Clip for Terminal Bloc C0064 Hose Air M1/8 -F1/4 170mm C0007 Cover to Terminal Bloc E59 + E88 C0065 Fitting L Rotating M1/4-6,3mm C0008 Overload Protector E59 230V C0067 Bolt TE M8x35mm UNI 5739 C0009 Relay Starting 230V E59 C0068 Power Cord 230V Euro-Plug C0011 Filter Air-Intake C0080XX Pump Compressor 230V E88 C0013XX Pump Compressor E59 230V C0094 Foot Rubber C0021 Drain Cock M1/8 C0105 Bolt TE M8x30mm UNI 5739 C0024 Plug for Oilfill C0108 Terminal Bloc C0025 Gasket Housing C0120 Washer flat d=8-24mm UNI 6593 C0026 Gauge Pressure M1/8 -side 10 Bar d=40mm C0121 Bracket for Capacitor C0028 Fitting M1/4 -M1/4 C0122 Capacitor 230V AE 2415 53-64 MFD C0030 Closing Band E59 + E88 C0123 Overload Protector 230V AE 2415 C0034 Strain Relief C0125 Relay Starting 230V AE 2415 C0040 Fitting Reduction M1/4 -F1/8 C0127 Clip for Terminal Bloc AE 2415 C0043 Bolt M6x10mm DIN 934 C0128 Gasket Intake-Valve AE 2415 C0046 Valve Check M1/8 -F1/8 C0129 Valve Plate cpl. AE 2415 C0047 Fitting M5-d=6mm C0130 Gasket Exhaust-Valve AE 2415 C0048 Switch Pressure 4-P 230V MDR 2/11 C0132 Bolt C0048-1 Cover to Switch Pressure C0048 C0151 Fitting M1/4 -M1/4 60mm C0048-2 Switch Pressure E59 C0164 Filter Regulator WI C0051 Hose Nylon 6/4mm C0164-1 Pressure Bowl WI C0052 Gasket Intake-Valve E88 C0164-2 Filter Element C0053 Valve Plate cpl. E88 C0164-4 Filter Regulator SMC C0054 Gasket Exhaust-Valve E88 C0164-5 Pressure Bowl SMC C0055 Relay Starting 230V E88 C0164-6 Filter Element SMC C0056 Overload Protector 230V E88 C0164-7 Washer for Filter SMC C0058 Closing Band AE 2415 C0171 Kit for Grounding C0180 Power Cord 115V American-Pl. 2000mm C0364 Bolt and Nut for Closing Band C0202 Valve Head-Pressure Release C0365 Kit Terminal Bloc E59 230V C0214 Kit Terminal Bloc E88 230V C0373 Relay Starting 115V E59 C0215 Kit Terminal Bloc E88 115V C0374 Overload Protector 115V E59 C0216 Overload Protector 115V E88 C0375 Kit Terminal Bloc E59 115V C0217 Relay Starting 115V E88 C0413 Handle C0218XX Pump Compressor 115V E88 C0414 Insert to Handle C0225 Capacitor 115V 145-174 MFD AE 2415 C0416 Cable Electric 115V 600mm C0226 Overload Protector 115V AE 2415 C0450 Cable Electric 230V 600mm C0227 Relay Starting 115V AE 2415 C0617 Washer 6x12mm UNI 6592 C0229 Foot Rubber AE 2415 C0672 Fitting T M1/4 -M1/4 -M1/4 C0230 Cover for Terminal Bloc C0797XX Housing DR 150 and DR 300 C0231 Terminal Bloc AE 2415 C0804XX Housing DR 500 C0232 Spring for Overload AE 2415 C0836XX Tank DR 150 and DR 300, black C0233 Kit Terminal Bloc 230V AE 2415 C0837XX Tank DR 500, black C0234 Kit Terminal Bloc 115V AE 2415 C0939 Bolt TCEI M8x12mm UNI 5931 C0235XX Pump Compressor 230V AE 2415 C1236 Kit Valve-Plate E88 cpl. with Gaskets C0236XX Pump Compressor 115V AE 2415 C1237 Kit Valve-Plate E59 cpl. with C0250XX Pump Compressor 115V E59 C1238 Kit Valve-Plate AE 2415 cpl. with Gaskets C0340 Switch Pressure 4-P 115V MDR 21-EA/11 C1394 Valve Safety M1/4 10 Bar C0349 Spring for Overload E59 and E88 R0153 Bolt M8x25mm UNI 5739