HI-FORCE ELECTRIC DRIVEN HEP PUMPS OPERATING INSTRUCTIONS

Similar documents
50t. Product training courses. 40t

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800) Internet Address:

MODEL G300 BRAKE BLEEDER

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Rexroth Hydraulic Pump A10VO Series User Manual

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

PC1131 Electric Air Compressor

Hydraulic Troubleshooting PRESENTED BY

Troubleshooting Guide for Jacks Down LED Lights

SHHH AIR COMPRESSOR Model Nos. SHHH2 - SHHH2/9 - SHHH3/9 - SHH3/24

PC1130 Electric Air Compressor

Power Cube Open Source Ecology Page 1. Power Cube. Version 4

10 TON HYDRAULIC PRESS

NITROUS TRANSFER PUMP INSTRUCTIONS

Oil and Coolant Circulating Heating System. Model - OCSM

HAND PUMP OPERATION, SERVICE AND PARTS INSTRUCTION MANUAL

HPU14M-DS 2013 Daniels Manufacturing Corp., All Rights Reserved Page 1 of 17 REV. C 7/2013

Float and Thermostatic Traps Series H, C and X

PART 2 FORKLIFT HYDRAULIC SYSTEM

ACCUMULATOR INSTALLATION

Unit 24: Applications of Pneumatics and Hydraulics

Hydraulic Trouble Shooting

Installation, operation and maintenance manual

2003 ACCORD - Automatic Transmission Removal

OPERATING INSTRUCTION MANUAL FOR S-240 HYDRAULIC CUTTERS WITH PARTS LIST

Not required for most applications Not required for most applications High pressure ( provided) High pressure ( provided)

OCTOPUS SELECTION & INSTALLATION GUIDE

7.1. Part Lists. Hardware Insertion Machine. Instructions. Instructions

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Number Wheeler P/N Description Set Rex P/N Notes Base 1 J Support, Right 1 J Support, Left 1 J Nut (M8)

Operators manual Basic water heater

Hydraulic control unit series

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

Professional Precharged Hunting Rifle

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

ELLIOTT COLLET STYLE Baffle Expander With Hydraulic Power Supply

Chapter 7 Hydraulic System Troubleshooting

copy The New CFD Rabbit Tool: TNT FE-5.0 Forcible Entry Tool

Cooling system components, removing and installing

Auxiliary Rams USERS MANUAL

San josé OWNER S MANUAL

MODEL 565E - 22 TON AIR/HYDRAULIC AXLE JACK

Operating Instruction Manual For S-40B Hydraulic Cutters With Parts List

TOYOTA ELECTRONIC TRANSMISSION CHECKS & DIAGNOSIS

Installation Instructions

Assembly overview - fuel tank

Auto-belay Cable Replacement Process

Procurement Specification for a High Security Lift Arm Barrier (HSLAB) EB950 CR Armstrong High Security Lift Arm Barrier

Number Wheeler P/N Description Set Rex P/N Notes

Procedure for testing the integrity of the Festo and Numatics valve stacks:

AerAtron. Ceiling fans

Sport Ice Elektro 124

Number Wheeler P/N Description Set Rex P/N Notes

AerAtron. Ceiling fans

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR İ-COLD Rev. 00

Volkswagen Golf > VW Rabbit GTI 2006->

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

8 ton air/hydraulic long ram jack

National- Spencer Inc.

ENGINE FUEL FUEL FILTER... FUEL HEATER... INJECTOR... SUPPLY PUMP... COMMON RAIL... FUEL PRESSURE LIMITTER...

INVERTER GENERATOR OWNER S MANUAL FOR YOUR SAFETY PLEASE READ THESE INSTRUCTIONS CAREFULLY AND RETAIN THEM FOR FUTURE USE.

Meritor WABCO Hydraulic Power Brake (HPB) System Bleeding Procedures

Compressor Service & Maintenance Manual

Water Pump Replacement

1 TON FOLDING CRANE CFC1000

Belt Driven Compressors

tire inflator with pressure gauge

PUMP MAINTENANCE SCHEDULE AND CHECKLISTS

Hydraulic Flow Control Valves

Range Road RR Series Semi-Automatic Firewood Processor. Crated Unit Assembly Manual

Procenter Delivery System* Troubleshooting Charts

Air Vantage 500 Kubota

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

CPL SYSTEMS / GROENEVELD AUTOMATIC GREASING SYSTEM COMPLETE SYSTEM CHECK PNEUMATIC PUMP

Installation Instructions - For the following HEATER model numbers: 200, 300, 400, 500 Series Hydronic Heaters

Cooling system components

MFH-5057 Ford Small-Block V-8 Fresh Water Cooling Kit Instructions

BUT PRECAUTIONS MUST BE TAKEN OR SERIOUS BURNS CAN RESULT.

SERVICE & OPERATING MANUAL ELECTRONIC LEAK DETECTOR WARNING VDC

Cooling Systems. Table of Contents

Kobelco Extended Warranty Program.

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Stainless Steel Single and Dual Circulation Kits

Railgates By THIEMAN IMPORTANT! KEEP IN VEHICLE! PLEASE READ AND UNDERSTAND THE CONTENTS OF THIS MANUAL BEFORE OPERATING THE EQUIPMENT.

15GAL STEEL OIL DRAIN WITH 110V PUMP

MODEL T200-F18 MODEL T125-F18 Finish Nailers

VOYAGER 570G. 744A Sprayer Control

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

Operation Manual. 5-Ton Electric Log Splitter MODEL #

Draining and filling cooling system

Cylinder Leak- Down Tester

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Your safety and the safety of others are very important.

INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS

Hydraulic Transmission Jacks Operating Instructions & Parts Manual

Transcription:

Hi-Force HEP series pumps are designed to operate high pressure hydraulic cylinders and tools with a maximum working pressure of 700 bar. These instructions cover all HEP series models. Refer to nameplate on pump for model identification. Common models and uses are given below HEP SERIES PUMPS: MODEL HEP207111 HEP207112 HEP207114 HEP207121 HEP207122 HEP207124 HEP207211 HEP207212 HEP207214 HEP207221 HEP207222 HEP207224 HEP207311 HEP207312 HEP207314 HEP207321 HEP207322 HEP207324 HEP207411 HEP207412 HEP207414 HEP207421 HEP207422 HEP207424 HEP310121 HEP310122 HEP310124 HEP310141 HEP310142 HEP310144 HEP310221 HEP310222 HEP310224 HEP310241 HEP310242 HEP310244 HEP310321 HEP310322 HEP310324 HEP310341 HEP310342 HEP310344 HEP310421 HEP310422 HEP310424 HEP310441 HEP310442 HEP310444 HEP517142 HEP517144 HEP517162 HEP517164 HEP517242 HEP517244 HEP517262 HEP517264 HEP517342 HEP517344 HEP517362 HEP517364 HEP517442 HEP517444 HEP517462 HEP517464 HYDRAULIC CONNECTIONS No control valve fitted. Pump (P) and tank (T) connections for single and double acting cylinders controlled by remote mounted valves. 2 way valve for operating single acting cylinders and tools requiring advance and retract but no hold function. For example crimpers and cutters. 3 way valve for operating single acting cylinders requiring advance, retract and central load hold position. For example simple lifting operations 4 way valve for operating double acting cylinders requiring advance, retract and central load hold position. For example lifting and positioning requiring more control. Note: Models with a suffix S (e.g. HEP207414S) have a 3 or 4 way solenoid operated valve with a remote control pendant. Page 1 of 8

SAFETY READ THIS MANUAL BEFORE OPERATING THE PUMP. FAILURE TO OBSERVE THE FOLLOWING WARNINGS COULD RESULT IN SERIOUS BODILY INJURY Ensure that all equipment connected to the pump is in good condition and is all rated for 700 bar operating pressure. Always stand the pump on a stable level surface during operation. Never invert the pump or lay it on its side either in use, transport or in storage. Inspect hoses regularly for damage and wear. Do not use hoses that are frayed, abraded or leaking. Never move the pump by pulling the hoses. Do not work with hoses sharply bent or kinked. Do not handle hoses that are pressurised. Oil escaping under pressure can penetrate the skin causing serious injury. If oil is injected under the skin see a doctor immediately. Never pressurise uncoupled couplers. Always use eye, ear and hand protective equipment when using this pump and associated equipment. Beware of hot surfaces on the motor. Do not obstruct the flow of cooling air around the motor. MAINTENANCE Inspect the pump for damage after each use. Change the oil every 500 working hours using Hi-Force HFO46 oil. Have the pump serviced regularly by a Hi-Force authorised repair centre. IDENTIFICATION OF COMPONENTS Refer to figure 1 and 2 on following pages. 1. Hydraulic oil drain plug. 2. Hydraulic directional control valve if fitted (type will vary) 3. Roll frame (optional). 4. Motor. 5. Oil filler breather cap. 6. Tank. 7. Hydraulic oil level gauge. 8. On/ off switches 9. Electrical control box. 10. Adjustable pressure relief valve. 11. Hydraulic service connections. (one or two ports, depending on valve type) 12. Remote control pendant (fitted to models with solenoid valves only). Page 2 of 8

Page 3 of 8

PREPARING THE PUMP FOR FIRST USE 1. Immediately after unpacking, examine the pump for signs of transit damage and if found contact the shipping company. 2. Establish the oil level in the oil reservoir using the level gauge on the end of the tank. Depending on the shipping method used, the reservoir may either be supplied full or empty. If the reservoir is empty it must be correctly filled before use. Remove the temporary transit plate which is fitted in the position of the filler breather cap (5) by undoing the 3 screws. Fit the filler breather cap (packed separately) using the 3 screws which held the transit plate. 3. To fill the reservoir: Remove the filler cap (5) and fill the tank with clean HFO46 oil to the upper level indicator (7). 4. Make sure that the voltage indicated on the motor rating plate corresponds with the available supply. 5. Remove steel or plastic hexagon headed plugs and make hydraulic connections to service ports (11). These ports have a 3/8 NPT female thread and the corresponding male connections should be wrapped with PTFE tape or other suitable sealant. N.B On 3 way valves the service port is the right hand one, when viewed as in figure 1. 6. Ensure the lever of the hydraulic directional control valve (2) is in the neutral position: This is fully anticlockwise for models with 2 way valve or the central position for models with 3 or 4 way valves. Where valves are remotely mounted, ensure these are adjusted such that pressure will not build up during the starting operation. See table on page 1. 7. Ensure switch is set to off (8). Connect motor to required power source. 8. Check the direction of the motor rotation by turning the starter switch (8) to the ON position then to the off position, whilst doing this observe the motor fan. The motor should run in a clockwise direction viewed from above. If the direction is wrong check the wiring of the electrical connector. Running the pump with incorrect rotation may damage the low pressure pump unit. Page 4 of 8

OPERATION OF PUMPS WITH MANUAL VALVES Hi-Force does not necessarily know what equipment this pump will power. Read and understand the appropriate operating instructions relating to the equipment in use. 1. With all hydraulic connections made and motor running, operate the directional control valve (2) if fitted to control the cylinders or tools in use. For pumps with 2 way valves: Turning the lever full clockwise will supply oil to the service port and advance the cylinder. Turning the lever anticlockwise will retract the cylinder. For pumps with 3 way valves: Mid position is the load hold position. Moving the lever so that it is above the service port (anti-clockwise) will supply oil to the port and advance the cylinder. Moving the lever away from the service port will connect the service port to tank and retract the cylinder. For pumps with 4 way valves: Mid position is the load hold position. Moving the lever so that it is above either service port will supply oil to that port and connect the opposite port to tank. 2. The pump is fitted with an adjustable pressure relief valve (10) to restrict the output pressure to any desired value up to the maximum working pressure of the pump. To increase the relief valve setting turn the control knob clockwise. To decrease the relief valve setting turn the control knob anticlockwise. Leaving the pump running for extended periods with the relief valve operating will cause the oil to overheat. 3. Ensure that the oil level does not fall below the minimum level as shown by the lower indicator (7) OPERATION OR PUMPS WITH SOLENOID VALVES 1. Turn switch to on position (8) 2. Depress advance button on pendant to advance cylinder. (Cylinder remains in the load holding position when button released). 3. Depress retract button to retract cylinder. Page 5 of 8

NOTE:- Page 6 of 8

NOTE:- Page 7 of 8

UK Head Office: Hi-Force Limited Prospect Way, Daventry, Northants, NN11 8PL, United Kingdom,..Tel: +44 301 000..Fax: +44 706 555 Email: daventry@hi-force.com Hi-Force Regional Offices: Hi-Force Australia Pty. Ltd Rockingham Australia Tel: +61 8 9591 1288 Email: australia@hi-force.com Hi-Force Hydraulics (Asia) S.B Selangor Malaysia Tel: +603 5569 4209 Email: malaysia@hi-force.com Hi-Force Hydraulics (Pty) Ltd Midrand South Africa Tel: +27 11 314 0555 Email: south.africa@hi-force.com Hi-Force Hydraulics Abu Dhabi United Arab Emirates Tel: +971 2 551 3100 Email: abu.dhabi@hi-force.com Hi-Force Caspian Baku Azerbaijan Tel: +994 12 447 4100 Email: baku@hi-force.com Hi-Force Nederland BV Strijen Netherlands Tel: +31 78 6745488 Email: holland@hi-force.com Hi-Force FZCO Dubai United Arab Emirates Tel: +971 4 815 0600 Email: dubai@hi-force.com Hi-Force Hydraulic Equipment (Shanghai) Ltd. Co. Shanghai, China Tel: +86 21 6697 3010 Email: china@hi-force.com GLOBAL BRAND.LOCAL SERVICE. www.hi-force.com Page 8 of 8