VAC-ALERT VAC- ALERT

Similar documents
WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS

Oil and Coolant Circulating Heating System. Model - OCSM

INSTALLATION & OPERATING INSTRUCTIONS

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

SELECTION, APPLICATION AND MAINTENANCE

ETL listed for installations within 5 ft. (1.5M) of outer edge of water Rev E Page 1 of 10

Float and Thermostatic Traps Series H, C and X

Unit 24: Applications of Pneumatics and Hydraulics

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

Hydraulic control unit series

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

CTV-1500 Cooling Tower Vacuum Operating & Maintenance Manual

Lawn Sprinkler Systems Reserve Irrigation Inc. O & M. Version Roseland Drive Macedonia, Ohio

Unit 24: Applications of Pneumatics and Hydraulics

DIAMOND Retractable Rodding Robot Model SPRAYROD-R

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions

FJ2. 2 Ton Trolley Floor Jack Assembly & Operating Instructions

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

SWIMMING POOLS, SPAS AND HOT TUBS Section AG101 General.

BERMUDA GUNITE SKIMMER FOR SWIMMING POOLS

MA BUILDING CODES ON SWIMMING POOLS SECTION 780 CMR 120.M

SELECTION, APPLICATION AND MAINTENANCE

STABITHERM INSTALLATION & SERVICE BOOKLET

OPL BASIC. Dosing System for Professional Laundry machines. Contents

PRESSURE REDUCING CONTROL VALVE

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Fiberstars Lighted Laminar Flow Fountain Installation Manual

STC 3S A Series Solenoid Valves

Installation Instructions S

Product Manual. CVS Type 67AFR Filter Regulator. Introduction. Installation. Description

AIR LINE VALVES AND GAUGES

APPLIED PNEUMATICS AND HYDRAULICS H TUTORIAL HYDRAULIC AND PNEUMATIC CYLINDERS. This work covers part of outcome 2 of the standard Edexcel module.

Morrison Bros. Co. General Product Specifications

Chapter 7 Hydraulic System Troubleshooting

Submersion/Insertion Toroidal Sensor

PLUMBING CARE AND REPAIR

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

National- Spencer Inc.

INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS

PC1130 Electric Air Compressor

M A N U A L

Stainless Steel Single and Dual Circulation Kits

Your safety and the safety of others are very important.

Select Radiators Installation Guide

BACKPACK SPRAYERS. MODEL NOS: KSP16 & KSP20 Part Nos: & OPERATING & MAINTENANCE INSTRUCTIONS GC04/12

PC1131 Electric Air Compressor

A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps

Rexroth Hydraulic Pump A10VO Series User Manual

MVX-Series Diesel Engine Air Shut Down Valves

PBX Series Quick Fit Connector Bimetallic Steam Traps

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

SWIMMING POOL, SPA, & HOT TUB GUIDELINES

CYLINDER LEAKAGE CHECK (Compression)

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

MODEL INSTALLATION INSTRUCTIONS

Coolflo Safe Touch Shower Mixing Valve ST20015CP

TRAINING AND EQUIPMENT MANUAL HOSE PRACTICES EFFECTIVE: OCTOBER 2007

Example. Fluid Power. Circuits

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

Tri-Homo Style Operation and Maintenance Instructions

CPL SYSTEMS / GROENEVELD AUTOMATIC GREASING SYSTEM COMPLETE SYSTEM CHECK PNEUMATIC PUMP

=============================== WARNING

BRAKE SYSTEM OVERVIEW AND OPERATION PROCESS 1. BRAKE SYSTEM GENERAL INFORMATION 1) DESCRIPTION AND OPERATION 16-3.

Technical Guide 08/15/14

2006 HEADSHOK Service Video #1

Please also see 10 golden rules for correct Saniflo installation on

System Saver 318 Air Compressor for Mack E-Tech and ASET Engines

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

2010 Residential Water Heater Replacement Check List

Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation

1. Description. 2. List of Accessories included A B C F G H

SIMPLAIR PIPING TOOL

TYPE E Main Valve Sizes 3 /8 through 12

! WARNING. Before using product, read and understand instructions.

BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap

APCO SLOW CLOSING AIR/VACUUM VALVES

3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

BETTIS CONVERSION INSTRUCTIONS TO CONVERT HD SERIES ACTUATORS TO HD-M3, HD-SR-M3 HD-M3HW OR HD-SR-M3HW SERIES PNEUMATIC ACTUATORS

BERMAD Fire Protection

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

SPECIFICATION DIVISION 22 SECTION DESCRIPTION DIVISION 22 PLUMBING SECTION THERMOMETERS, PRESSURE GAUGES, AND ACCESSORIES

PART 2 FORKLIFT HYDRAULIC SYSTEM

OPERATING INSTRUCTION MANUAL FOR S-240 HYDRAULIC CUTTERS WITH PARTS LIST

Model Series. PumpAgents.com - buy pumps and parts online QUIET - FLUSH ELECTRIC TOILET. Model Series FEATURES SPECIFICATIONS INSTALLATION

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

INSTALLATION AND SERVICE MANUAL

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

Maintenance and Operating Instructions SIS 120P/SISF

MPX-Series Diesel Engine Shut Down Valves (Manual Reset / Air Pressure and Manual Closure Options)

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

V47 Series Temperature Actuated Modulating Water Valves

Installation Instructions

Arctic Leash Instruction Manual Alaskan Products Company LLC.

Air Eliminators and Combination Air Eliminators Strainers

Transcription:

C-ALERT C-ALERT---- --------------------- C- ALERT ---- --------------- IMPORTANT NOTICES ------------------- Applications: Model Type: -2000S When Pump is located below water level Model Type: -2000L When Pump is located either at or above the pool water surface level Installation Instructions

MSI C-ALERT Installation Instructions Page 1 of 10 IMPORTANT READ THESE INSTRUCTIONS BEFORE INSTALLATION! The Dangers of Entrapment If a swimmer or bather becomes stuck to a deep suction drain or suction outlet in a swimming pool, paddling pool, or spa, the force from the circulating pump can be tremendous. This effect is known as; suction entrapment and it will hold the bather in its grip until either the vacuum is broken, or until he or she drowns, defying the efforts of rescuers. What is a Safety Vacuum Release System (SVRS)? An SVRS is a device capable of providing a vacuum release at a suction outlet caused by a high vacuum occurrence due to a suction outlet flow blockage. The SVRS unit reacts in less than a second to quickly release life threatening system suction. SVRS devices must allow for vacuum release with or without suction outlet cover(s) in place, and shall operate in such a way as to not defeat or disengage other layers of protection installed to protect against suction entrapment. Vac-Alert TM Safety Vacuum Release System (SVRS) The Vac-Alert TM - SVRS is a non-electrical self-monitoring, low-maintenance safety system that responds in milliseconds to an increase in pump suction vacuum that can be caused when someone is trapped. The Vac-Alert s spring loaded piston reacts quickly opening to atmosphere and releasing the life-threatening system suction. Once installed, it takes little or no maintenance. Its non-corroding PVC and stainless steel construction ensure long life and superior performance. We recommended Vac-Alert to be installed by a professional pool engineer.

MSI C-ALERT Installation Instructions Page 2 of 10 FEATURES & BENEFITS OF: C-ALERT 2000 SVRS 1. Vac-Alert is the perfect safety solution for any pump that draws water, including pools, spas, fountains, slides and vacuum ports and will not damage your pump when tripped. 2. Vac-Alert (SVRS) is precision engineered to react in milliseconds, stopping accidents before they happen, reducing the risk of fatality. 3. Vac-Alert is designed for applications where the pump is either above or below the level of the pool water surface...2000s is for submerged and 2000L is for lift. 4. Quick to install The Vac- Alert can be fitted within thirty minutes and an installation DVD is available. Note: Additional time may be required for the solvent cement to properly set to a useable condition inline with manufacturer s specifications. We recommended Vac-Alert to be installed by a professional pool engineer. 5. The Vac-Alert is easily plumbed into the pipe-work (suction side only) and is designed to sense sudden increases in vacuum pressure, which triggers the valve pistons to lock, allowing air to enter the system and releasing the vacuum on the main drain. 6. Vac-Alert is self monitoring, non electrical and low maintenance. 7. Long lasting design features moisture resistant PVC, and stainless steel construction. 8. Reliability Vac-Alert has several years field experience & in some regions internationally legislation requires pool owners use equipment like Vac-Alert to retrofit pools and spas. 9. Meets all requirements of the International Code Council, both the International Building Code (IBC) and the International Residential Code (IRC). Meets or exceeds all the ANSI/ASME performance standards for safety vacuum release systems. 10. Vac-Alert has a 3-year limited warranty ensures reliability. CODES OF COMPLIENCE: Vac-Alert -2000 Complies with ASME/ANSI A112.19.17 as required by the International Building Codes (IBC) and the International Residential Codes (IRC) The Vac-Alert -2000 was tested by Applied Research Laboratories and found to comply with ASME/ANSI 112.19.17, "Manufactured Safety Vacuum Release Systems (SVRS) for Residential and Commercial Swimming Pool, Spa, Hot Tub and Wading Pool Suction Systems." The ASME/ANSI 112.19.17 is the required standard in the International Building Code (IBC) and the International Residential Code (IRC) for items that provide vacuum relief (SVRS).

MSI C-ALERT Installation Instructions Page 3 of 10 IMPORTANT: PRIOR TO INSTALLATION IMPORTANT: PRIOR TO INSTALLATION: 1. Before installing Vac-Alert, you need to determine if the filter pump is installed: A - Below water level (Suction) Model Type: 2000S or B - At or above water level (Lift) Model Type: 2000L. 2. You must check the plant-room suction pipe-work to determine if it is metal or plastic. If it is metal a suitable boss/adaptor will need to be fitted to the existing pipe-work. If there are no threaded joints, on-site welding may be necessary. The Vac-Alert Model -2000S (Submerged): Is designed for: submerged suction applications. This applies to all applications where the circulating pump suction is below the level of the pool water surface. This unit incorporates a 0.375 diameter orifice opening installed below the surge tube section. This orifice opening is sized to provide a limited amount of pump start-up surge protection, while at the same time allowing enough air into the piping system to insure dissipation of the dynamic suction force caused by the circulating pump. The Model -2000S SVRS unit also utilizes a check valve assembly equipped with a 0.25 pound spring and a non-vented poppet (no poppet disc or hole through the poppet). This check valve assembly utilizes a light duty spring to minimize the sealing force of the check valve. The non-vented poppet insures that water from the circulating system, under a positive hydrostatic head condition, does not migrate up into the SVRS. NOTE: For pumps operating 24/7 we recommend installation of the -2000S (even if it's a lift application situation). The Vac-Alert Model -2000L (Lift): Is designed for: suction lift applications. This applies to all applications where the circulating pump suction is either at or above the level of the pool water surface (up to 3.5 feet 1.1m). This unit incorporates a 0.170 diameter orifice opening installed below the surge tube section. This orifice opening is sized to prevent nuisance tripping of the SVRS unit caused by high vacuum surges typical of many pump start-up conditions. The Model -2000L SVRS unit also utilizes a check valve assembly equipped with a 3.5 pound spring, a poppet disc and a one-way (up only) vented poppet This check valve assembly permits continued water flow to the circulating pump while the SVRS unit is in the open or vented position. The 3.5 pound spring further compressed by the poppet disc, creates enough sealing force within the check valve to allow partial water flow to the circulating pump for suction lifts up to 3.5 feet (1.10m). This is critical to the elimination of circulating pump damage that can be caused by a sustained dry-running condition. The one-way vented poppet allows the surge chamber to be internally recharged when the circulating pump is turned off. For pumps operating 24/7 we recommend installation of the -2000S (even if it's a lift application situation.

MSI C-ALERT Installation Instructions Page 4 of 10 C-ALERT -2000 Vacuum Gauge Air Entry on Activation Adjustment Screw Vent Screen Lock Out Release Mechanism Surge Suppression Chamber Filter Screen Check Valve Connection Point Negative Pressure (Vacuum) Existing Suction Pipe-work WATER FLOW

MSI C-ALERT Installation Instructions Page 5 of 10 General Circuit Layout SWIMMING POOL PLANT ROOM C-ALERT SVRS UNIT FILTER PRESSURE - - - MPV ISOLATION LVES PUMP WASTE DEDICATED TEST LVE RETURN INLET SPREADER DEEP SUCTION OUTLET (MAIN DRAIN) MAIN DRAIN SWIMMING POOL C-ALERT Model Type: -2000SVRS The Vac-Alert SVRS unit is a safety device designed to be installed on swimming pools, spas, fountains which include a deep suction (main drain) outlet and its function is to guard against bathers/users becoming accidentally entrapped on the deep suction outlet. To ensure correct operation, it is important that the Vac-Alert SVRS unit is properly installed onto the deep suction (main drain) pipe-work line prior to the pump. Vac-Alert must be in installed with a dedicated test valve prior to the unit. (See above diagram showing a typical pool layout).

MSI C-ALERT Installation Instructions Page 6 of 10 INCORRECT! Installing Vac-Alert CORRECT INCORRECT! 1. The Vac-Alert should be fitted to the (main drain) deep suction pipe-work which is of a size no greater than 10 (250mm) in diameter and with a maximum flow through of: 250m3/hr. Vac-Alert must not be fitted to pipe-work of a greater diameter and flow rate than stated. 2. Vac Alert should be installed on: The main suction line, and use one unit for each pump. Systems with dual pumps may need multiple units. Refer to installation layout diagrams on page 6 of these instructions to decide optimum position. 3. It is important that when installing Vac-Alert a record is kept of the units serial number, the pump type/size & serial number and the reading from the Vacuum gauge during normal running conditions. This information must be recorded on the warranty card supplied with the unit and returned to MSI. 4. Non return & Hydrostatic relief valves MUST NOT BE fitted to the same pipe-work line as the Vac Alert! 5. Your Vac-Alert Unit must be installed in a true vertical plane and MUST NOT be installed at an angle or in the horizontal plane. (See diagram above). 6. Your Vac-Alert must be installed on the main suction line with a dedicated ball or butterfly valve, in the pipe-work below the unit. This is to be used for testing and adjusting the unit. See diagram below. 7. Your Vac-Alert must be installed in a position where it is accessible for testing, servicing & monitoring. The vacuum gauge must be easily visible at all times. WHEN TESTING C-ALERT ALWAYS TURN THE TEST LVE SWIFTLY TO THE CLOSED POSITION BUT AVOID WATER HAMMER WHICH MAY DAMAGE PIPEWORK C-ALERT SVRS UNIT ISOLATION LVES PUMP DEDICATED TEST LVE

MSI C-ALERT Installation Instructions Page 7 of 10 Installing Vac-Alert Continued 8. Select from the circuit diagrams one that suits your application & install Vac-Alert accordingly. 9. DO NOT use 2/3 way valves as test valves! Always use a full bore ball valve or butterfly valve. KEY TO SYMBOLS = POOL PUMP FIGURE 1 SWIMMING POOL ONE (1) PUMP ONE (1) MAIN DRAIN PUMP FIGURE 2 SWIMMING POOL ONE (1) PUMP TWO (2) MAIN DRAIN S PUMP = SPA PUMP = 3 WAY LVE = ISOLATION LVE = C-ALERT UNIT CUUM CUUM = TEST LVE MAIN DRAIN SUCTION MAIN DRAIN SUCTION MAIN DRAIN SUCTION S FIGURE 3 SWIMMING POOL MULTIPLE PUMPS MULTIPLE MAIN DRAIN S PUMPS FIGURE 4 SPA POOL SPA PUMP FIGURE 5 WATER FEATURE FEATURE PUMP CUUM SPA FEATURE MAIN DRAIN SUCTION MAIN DRAINS SUCTION S MAIN DRAINS SUCTION S MAIN DRAINS SUCTION S

MSI C-ALERT Installation Instructions Page 8 of 10 Vacuum Gauge Factory Set at: 10 of Mercury 10 Remove Vent Screen (Pull off) Security Cap Testing & Setting Your Vac-Alert Place over Plastic Film to check for air leakage through vent hole 1. Your Vac-Alert unit has been factory adjusted to accommodate system vacuum levels up to 10 of mercury. Vacuum levels higher than this will require on site adjustment of the Vac-Alert unit. 2. Normal operating vacuum is the reading obtained from the Vac-Alert Vacuum gauge when there is no air leakage through the vent port (vent screen). 3. IMPORTANT: Before adjusting or testing your Vac-Alert, any secondary source lines must be closed. 4. With the pump running (and all secondary lines closed off), remove the vent screen and check for air leakage. This can be achieved by either holding the palm of your hand or placing some plastic film over the vent hole exposed by the removal of the screen. If a leak is present the unit will need to be adjusted to accommodate the higher vacuum level. On Site Adjustment of your Vac-Alert 5. Before adjusting: Turn pump off. 6. With Vent screen removed; insert a screwdriver into the exposed vent hole and push the piston forward until you hear a click when the piston is locked. PISTON SECURITY CAP CLICK

MSI C-ALERT Installation Instructions Page 9 of 10 UNSCREW SECURITY CAP HEAD ADJUSTMENT SCREW Lock Out Release Mechanism Adjusting Your Vac-Alert (Continued) 7. Unscrew (anticlockwise) the stainless steel security cap using the tool provided. 8. Using a flat head screwdriver turn the head adjustment screw 3 full turns in a clockwise direction. 9. Replace the security cap, then press down the red reset lever to unlock the piston. 10. Restart the pump and re-check for air leakage. If an air leak is still present, repeat the procedure as in steps 7 9 above. Testing Your Vac-Alert 11. Before testing, ensure the vent screen is free of debris & is correctly in place. 12. With the pump fully primed and running use the test valve to simulate an entrapment condition. 13. Swiftly rotate the dedicated test valve lever, (but avoid water hammer) the gauge pressure will increase and the piston inside the Vac-Alert unit will lock open causing the pump to cavitate. Turn the pump off and press down the red re-set (lock-out release) lever to reactivate the unit. 14. Repeat this test procedure at least three times in succession to ensure successful operation. 15. If the Vac-Alert piston does not lock out with the test valve closed you must check to ensure that there is no air entering the system via the pipe-work joints or cracks. If the system is free of air, it may be that the pump is not generating a sufficient vacuum to trigger the Vac-Alert, in which case you will need to adjust the unit by turning the adjustment screw in an anticlockwise direction and re-test the unit to ensure the piston activates each time the test valve is closed. NORMAL RUNNING CUUM SURGE AIR FLOW IN WATER FLOW TEST LVE CLOSED AIR FLOW OUT

MSI C-ALERT Installation Instructions Page 10 of 10 Periodic Maintenance 16. Test the Vac-Alert at least once a month to ensure correct operation. 17. Periodically (every 3 months) remove the vent screen and clean from debris. 18. The Vac-Alert is a sealed unit and otherwise requires no internal maintenance if installed correctly. C-ALERT: QUESTIONS & ANSWERS Does Vac-Alert TM Va-2000 meet the new state codes? Vac-Alert TM -2000 meets or exceeds all new state codes regarding entrapment protection. Vac-Alert TM is third-party tested to meet the performance requirements complying with ASME/ANSI 112.19.17 manufactured safety vacuum release system (SVRS). Will Vac-Alert TM affect my operating system suction or return pressure? Properly installed, Vac-Alert TM -2000 will not affect operating flow. Vac-Alert TM is designed to react to a sudden spike in suction. Water never enters the unit itself; therefore your system will not be negatively affected. How does Vac-Alert TM prevent entrapment? Piston activation introduces air into the suction line and quickly cavitates pump and releases the suction force. How do I maintain Vac-Alert TM -2000? Vac-Alert TM is made from durable PVC, Viton and rust resistant 316 stainless steel; which guarantees longlasting reliable service. The Vac-Alert TM all mechanical, non-electrical design ensures that you will never be forced to replace costly electrical switches, relays or solenoids that are destroyed by chemical vapor and moisture intrusion. Vac-Alert TM -2000 comes with a 3-year limited warranty. Should I install a Vac-Alert TM on every pump? Most state codes require one (1) SVRS for every pump that draws water from the pool. This includes pumps dedicated to spas, fountains, slides and other amenities. Will Vac-Alert TM burn up my pump if it trips? The -2000 is designed with a check valve to maintain an approximate 30% flow if tripped. This is more than adequate flow to protect the pump but allows no strong suction force to be re-established. How is Vac-Alert TM -2000 installed? Vac-Alert TM is easily installed and field adjusted. Vac-Alert TM is vertically mounted by teeing into the suction line between the main drain outlet and the pool pump. A detailed installation video and field guide is included with every Vac-Alert TM. How do I ensure Vac-Alert TM is working properly? Vac-Alert TM Should be tested once per month, as per manufacturer s recommendations.