Innovation #9/12. of all Formaldehyde for up to



Similar documents
Rigidur H Activ Air. Rigidur H Activ Air. For room to breathe

Clean air, top acoustics, great look it covers simply everything.

Specification. Indoor Air Quality Management

HVAC Systems and Indoor Air Quality. Douglas K. Spratt, M.Sc., P.Eng.

Mold Preventing I nterior System

Indoor Air Quality- What You Need to Know

IEQ Management Plan. Denver Museum of Nature and Science ECF Addition

Indoor Air Quality Issues for Hotels

IEQ-15 Air Distribution System

Indoor Air Quality. 2. Test and identify sources that contribute to poor indoor air quality.

Mold and Mildew Mold and mildew can be detected by sight, smell and touch.

Breathing The Air In Your Home Is Like Living In A Closed Jar. It s Enough To Make You Sick.

Information paper 20. Prepared by: David Clark. book:

INDOOR AIR QUALITY INTRODUCTION WHAT ARE THE SYMPTOMS OF SICK BUILDING SYNDROME? WHEN DID POOR INDOOR AIR QUALITY BECOME A PROBLEM?

"An Office Building Occupant's Guide to Indoor Air Quality"

about your house How to Get the Ventilation That You Need in Your House Figure 1 Infiltration and exfiltration of air in a house

Construction Indoor Air Quality Management Plans for LEED. Matt Gregg, PE, LEED AP

There are several types of air cleaning devices available, each designed to remove certain types of pollutants.

Ventilation Solutions Fresh Air Solutions for Ductless Heating & Cooling. fantech

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

fire & soundproofing Insulation Roxul Safe n Sound Fire and Soundproofing Insulation for Interior Partition Walls and Floors

Fire & Soundproofing Insulation. Roxul SAFE N SOUND. Fire and Soundproofing Insulation for Interior Partition Walls and Floors.

Molds and mildew are fungi that grow

ECHO System for Basements

The Finnish Classification of Indoor Environment and Material Emissions

Building and Grounds Maintenance Checklist

06150 PORVOO, FINLAND Pelican eco ED(D), Pelican eco EDE(D), Pelican eco EDW(D), Pelican eco EDX(D)

Guidelines for Cleaning Staff on Managing Mould Growth in State Buildings

BUILDING ASSESSMENT QUESTIONNAIRE. B. TENANTS Is there more than one tenant in the building? YES

How To Get A Passive House

Mold Questions and Answers Questions and Answers on Stachybotrys chartarum and other molds

Safety Data Sheet Customwood MDF

Points of Construction

Got Mold? Frequently Asked Questions About Mold

Educational Performance, Environmental Management, and Cleaning Effectiveness in School Environments

APPENDIX B. EPA s Investigating, Evaluating, and Remediating Moisture and Mold Problems (see EPA website for complete details)

WATER DAMAGE INVESTIGATION. Massachusetts Gaming Commission 101 Federal Street Boston, Massachusetts

Why Measure Carbon Dioxide Inside Buildings? By Rich Prill, Washington State University Extension Energy Program

LEED PRESENTATION OUTLINE

Wildfire Smoke and Your Health

CEILING SYSTEMS. CI/SfB (35) Xy April [Between us, ideas become reality.] ULTIMA CANOPY. Data sheet. Acoustic performance meets High Design

Mould Mould A Basic Guide

INDOOR AIR QUALITY POST-OCCUPANCY ASSESSMENT. Massachusetts Department of Revenue 100 TradeCenter, Suite 760 Woburn, MA

THE APPLICATION OF OZONE FOR AIR TREATMENT: CASE STUDY OF A BINGO HALL HVAC SYSTEM

Radford University. Indoor Air Quality Management Plan

Glasroc F multiboard Five high performances in one board

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

INVESTIGATION OF INDOOR AIR QUALITY PROBLEMS IN UNIVERSITY OFFICES WITH A QUESTIONNAIRE

HVAC Costs. Reducing Building. Building owners are caught between two powerful forces the need to lower energy costs. By Stephen J.

bout your house before you start Renovating Your Basement Moisture Problems

CARPET CARE PROGRAM. Dustbane Products Limited

An Informational Pamphlet. 416 South East Street Lebanon, OH 45036

BETONYP building boards. The modern way of living.

Guidelines for Mold Remediation (Removal)

Renovation instructions

Indoor Air Quality FILL YOUR HOME WITH AIR THAT IS AS CLEAN AS IT IS COMFORTABLE. READ ONLY

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

How to Reduce Your Exposure to Chemicals at Home, Work, and Play

Multi-Foil reflective insulation SPACE SAVING U-VALUE AS LOW AS 0.16W/m 2 K LIGHTWEIGHT EASY TO FIX

PCR: NPCR010 Building boards

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

bout your HOUSE before you start Renovating Your Basement Moisture Problems

ENERGY SAVING WINDOW FILMS S LAR CONTROL

Manual lifting and handling

Fans That Sense & Extract Volatile Organic Compounds and Humidity

Heating and Ventilation

Carson Dorn, Inc. December 18, Patrick Holmes Associate Manager Juneau I, LLC 645 G Street, Suite Anchorage, AK Dear Mr.

Rockwool Flexi Insulation Application Guide

When considering your heating options, keep in mind that 60% of your energy. costs are attributed to space heating. You

The efficient heat pump

WATER DAMAGE INVESTIGATION. Massachusetts Department of Public Utilities 1 South Station Boston, Massachusetts

Before You Start an Energy Efficiency Retrofit The Building Envelope

April 25, 2014 Page 1 PRODUCT DESCRIPTION PRODUCT FEATURES

Basic Mold Prevention

Carbon monoxide. General information

Healthcare Solutions. Hygiene, comfort and productivity for your healing environment

C05. S03. P02 P08 FireWall. Including C05. S01. P02 Specialist partitions introduction

Mechanical and Natural Ventilation

Interior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM


AIR CONDITIONING - ENERGY CONSUMPTION AND ENVIRONMENTAL QUALITY

Mold Basics. Why is mold growing in my home?

PEOSH. Indoor Air Quality Training for Asthma-Friendly Schools Part I PEOSH Indoor Air Quality Standard Overview. Eric Weren, MSIH

We care about. Environmentally-Friendly Building Products from Renewable Resources. natural building products. Product range overview

Venice Library Humidity Study. for Williams Building Diagnostics, LLC th Street West Bradenton, FL Report April 13, 2015

Baumit Renders for Porotherm Masonry. Application Guidelines. n Light and easy application n Tried and tested

Birmingham City University / Students Union Aspects and Impacts Register. Waste. Impacts description

ULTIMATE GUIDE BE PREPARED FOR YOUR UPCOMING PROJECT

Mold. Guidelines for New Jersey Residents. Understanding Mold Investigations & Remediation

LIQUID DESICCANT AIR CONDITIONING Saves energy, Controls humidity, Cleans air

34% 81% 84% 19% GOLD PROJECT HIGHLIGHTS. LEED Facts. Stubbs Laboratory

Division 9. SignaFlor Pad and Pour Flooring System

PROPERTY INSPECTION OR ASSESSMENT OF DAMAGES

Saint Gobain Gyproc India Ltd. (Formerly India Gypsum Ltd.)

Transcription:

Innovation #9/12 of all Formaldehyde for up to

Gyproc Activ Air Benefits of Activ Air Improves the indoor air quality, providing healthier interior environments Permanently reduces Formaldehyde and other pollutants even after multiple renovations - providing peace of mind for generations Provides up to 75 years of Formaldehyde absorption, based on tests and analysis Can be used with most water-based acrylic and breathable wallpaper It is a passive system more effective in reducing Formaldehyde and other pollutants than additional ventilation. Activ Air is a revolutionary plasterboard from Saint-Gobain Gyproc that uses an innovative technology to actively improve indoor air quality by taking Formaldehyde out of the air and keeping it out. Why it s important to improve indoor air quality There is a rapidly growing awareness of the importance of indoor air quality and its impact on health and productivity. Research indicates that people spend approximately 90 percent of their time indoors. Factors affecting indoor air quality The indoor environment is affected by many factors, including local climate, heating, ventilation and air conditioning (HVAC) systems, building materials, occupants, and potential containment sources such as furnishings, moisture, and outdoor pollutants.

How Activ Air cleans the air Effectiveness of Activ Air on Formaldehyde 1. Captures Formaldehyde 2. Converts Formaldehyde into inert compounds 3. Inert compounds remain within gypsum board What does Formaldehyde do to air quality? Formaldehyde while typically not acutely toxic, has compounding long-term health effects. Exposure to poor indoor air can result in rapid fatigue, lack of concentration, eye irritation, allergies, difficulty breathing, headaches, nausea and sick building syndrome.

Where are the pollutants coming from? Formaldehyde Unsealed plywood or particleboard Treated fabrics Glues Carpets and furniture Carbonless copy paper Computers, copiers and printers Cleaning materials Paints, solvents, adhesives Carbon Monoxide Automobile exhaust from nearby garages, loading docks, roadways Carbon Dioxide Combustion of fossil fuels from heating equipment or generators Particulates Smoke, paper, water residue, carpet fibres, dust and other allergens Temperature and humidity extremes Improper thermostat, set points, unbalanced HVAC system, local climate, poor building design, poor humidity control Inadequate air circulation and ventilation Improper system design or operation, HVAC duct work or vent blockage, lack of maintaining air filters, poor office layout.

Independent tests prove its effectiveness The effectiveness of Gyproc Activ Air has been proven by two independent testing institutes. The ECO Institute in Cologne tested the air-purifying Independent effect of Gyproc tests Activ Air prove its on effectiveness! the basis of twelve different pollutants and the The reduction effectiveness of in Rigidur the H levels Activ Air has thereof on within basis of twelve a period different pollutants of 72 hours. in pollutant The concentrations decay curve in indoor for air in been proven by two independent testing in- and the reduction in the levels thereof contact with Rigidur H Activ Air. stitutes. aldehyde The ECO Institute illustrates in Cologne the tested reduction within a period in of pollutant 72 hours. The decay concentrations curve in indoor air in the air-purifying effect of Rigidur H for aldehyde illustrates the reduction contact with Gyproc Activ Air. Reduction in aldehyde concentration in indoor air in contact with % Gyproc Activ Air. (Initial concentration: 1 mg/m³ indoor air) 10 0 90 80 70 60 50 40 40 30 30 20 20 10 10 0 11 4 24 48 72 hours (www.eco-institut.de) Pollutant Percentage reduction in indoor air* Methanal (aldehyde) 100% Acetaldehyde 99.5% % 2-propenal 100% Propanal 99.3% % 2-Butenal 100% 2-Methyl-2-propenal 88.2% % 2-Butanone 82.2% % Butanal 100% 2-Pentenal 100% Pentanal 100% 2-Hexenal 100% Hexanal 100% *ECO Institute test results after 72 72 hours. Visit the Gyproc website to view the demonstration, www.gyproc.co.za Healthcare

Applications Activ Air technology takes the Formaldehyde and other pollutants, and converts them into safe, inert compounds that, once captured in the board, cannot be released back into the air. It keeps working for up to 75 years, based on tests and analysis, even after multiple renovations. Gyproc Activ Air is suitable for most system applications where normal fire, structural and acoustic levels are specified. Education Residential Healthcare Office Education

Activ Air Board Colour - Ivory Face paper - Brown reverse side paper Front Back Activ Air Board Range Detail Board Board thickness Width mm Length mm Edge Type Board Weight kg/m 2 1 Gyproc Activ Air 12.5mm 1200mm 3000mm T/E 8.4kg/m 2 2 3 4 Gyproc FireStop with Activ Air Gyptone BIG Quattro 41 with Activ Air Gyptone BIG Line 6 with Activ Air 12.5mm 1200mm 3000mm T/E 10kg/m 2 12.5mm 1200mm 2400mm T/E 7.8kg/m 2 12.5mm 1200mm 2400mm T/E 7.8kg/m 2

Finishing Jointing Gyproc RhinoGlide and Gyproc RhinoTape produce durable joint reinforcements and a smooth, continuous, crack-resistant surface ready for priming and final decoration. A number of jointing specifications are available to suit the board type, method of application, and site preference. Decoration After the joint treatment has dried, decoration including any decorator s preparatory work should follow. Please note however that any decoration should be breathable to allow Formaldehyde and other pollutants to be absorbed by the board. Please refer to the following notes. Painting: breathable paints- please consult your paint manufacturer Wallpaper: Use only breathable wallpapers Limitations Finishes that restrict the board surface permeability may inhibit the Formaldehyde absorption properties. Tiling, marble and other wall coverings can be applied, however this will limit the absorption of Formaldehyde and other pollutants for the area covered.

Board Performance Fire Protection Plasterboard linings provide good fire protection owing to the unique behaviour of the non-combustible gypsum core when subjected to high temperatures. The inclusion of glass fibre and other additives in the core of Gyproc FireStop with Activ Air improves its fire protection properties when compared to standard plasterboard. Fire Resistance Gyproc Activ Air will not compromise the fire performance of GypWall systems. For additional information please consult the Gyproc Technical and specifications department. Residential

Environmental facts Reduced CO 2, energy and water consumption by using Activ Air A large part of the energy consumption in the production of acoustic ceilings is used on heating. For this reason, and through many years of product and process development we have reduced the heat consumption and increased heat recovery by using new effective heat exchanging systems. In addition, the recirculation of water has been made a priority to reduce water consumption. Our process technology and material properties ensure very low energy consumption, CO 2 emission, consumption of raw materials and heat consumption during our production - the lowest on the market. Use recyclable materials Collected recycled gypsum is used in the production of new gypsum products. Offices

Customer contact centre: 0860 27 28 29 www.gyproc.co.za Magno Matt paper is manufactured at environmentally-friendly mills which are FSCTM certified. Magno is a wood-free, acid-free and chlorine-free paper. September 2014. For internal use only.