Foot switch. Installation, operation and maintenance manual

Similar documents
KNX R. Rain Sensor. Installation and Adjustment

KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119

Manual Ranging MultiMeter

804 Ti Stand. Manual EN

Model UT713 OPERATING MANUAL

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Proportional pressure regulators VPPE

Portable Air Conditioner

AutoRanging Digital MultiMeter

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2012

alpha DSL WTM EG Instructions for use ADSL-Modem alpha DSL WTM EG

Nucleus Freedom BTE Rechargeable Battery (A25) and Nucleus Freedom BTE Recharger

Digital input modules

KeContact P20 User manual

Tina 2A/B Adaptor unit

4.3-inch Back-Up Camera

Please read operating instructions carefully before use and keep for further reference.

Operating Instructions

BITMAIN. APW PSU Series User Guide

Mini multi-purpose sewing machine

Antenna Splitter ASA 1. Instruction manual

Operating Instructions Drill rig DRU160

Original instructions Tina 3A/Aps Adaptor unit

Smile 11 AS-i Emergency stop with safe AS-i input node

19 LED Tube Controller ORDERCODE 41003

Point of view HDMI Smart TV dongle Mini RF Keyboard

Explosion proof enclosures

INFRARED QUARTZ WALL HEATER

KNX L. Brightness Sensor. Installation and Adjustment. Item number 70119

3M Wrist Strap and Footwear Tester 740. User s Guide

OZW30. Central Unit SYNERGYR

Auto Feed Screwdriver

IN-OUT Thermometer with Cable Free Sensor and Clock

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U Technical characteristics types D and E

12 WATT LED AMBER LIGHT BAR

225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

12 Volt 30 Amp Digital Solar Charge Controller

I E D C E R T. Net MA N A G E ME N T S Y S T E M ISO 9001: RAVI. Pendant Stations LADY Series

Operating Instructions

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Operating Instructions Bedienungsanleitung Mode d emploi

NFC Communication Tray Model: HHX-IT3-Z

NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL

Infrarot-Bewegungsmelder IP44

Mini-led spotlight with magnetic base

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Product and functional description

Operating instructions IV / 2007

Drayton Digistat +2RF/+3RF

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions

PLC Control Unit for a CSM-C Steam Compact Clean Steam Generator

User manual TAB-10C

Operating instructions

Accessories SUNNY REMOTE CONTROL

BeoLab 1. User s guide

MINI MCR-SL-R-UI(-SP)

How To Use A Power Supply On A Powerline 2.2 (Ai)

Instructions A Amp AC/DC Current Probe

alpha DSL WTM HS Instructions for use ADSL modem alpha DSL WTM HS

Ambient Temperature Sensor TEMPSENSOR-AMBIENT

High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual

Wind Sensor W-RS485 with RS485 Interface

149mm. Walk-Thru Assembly Gate. MODEL NO: 1161, 1167 Owner s Manual.

Auto-ranging Digital Multimeter INSTRUCTION MANUAL

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

G670 Intermittent Pilot Ignition Controls

IMPORTANT SAFETY INFORMATION

CappController Pipette Controller. Operation Manual Version:

Achat 208 HL / 208 HR passive mid-range speaker. user manual

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6

National- Spencer Inc.

Installation and safety instructions for AC/DC built-in devices

Wiring Instructions and Operating Manual 12 POINT ULTRABEAM REMOTE MONITORING SYSTEM

12/2010. Mod: G14/B. Production code: Multiplo 3S/L (NERO) HL

IMPORTANT SAFETY RULES TO FOLLOW

2-SLICE COOL TOUCH TOASTER

Model 1756 Test Lead Kit

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

DLP-PU/E Instruction Manual

ALI BABA PIANTANA (H165) design SLIDE Studio

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

pottery barn kids MADELINE BUNK BED

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Electronic Pressure Switch EDS 300

Duct Humidity Transmitter

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

1. CONGRATULATIONS! You have bought a great new product from MAGICFX.

TX OPEN RS232/485 module

Rousseau 10. User Guide

Terminal Boxes Series 8146

HERZ-Thermal Actuators

aseries A13B Mini Bullet Camera User Manual

Meaco 30L and Meaco 40L dehumidifier instruction manual

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Active Monitor Box McCrypt S.T.E.V.E. 15. Order No

MIC-WKT and MIC-WKT-IR

Transcription:

Installation, operation and maintenance manual ST Foot switch Read this manual before installing, operating or maintaining this actuator. Failure to follow safety precautions and instructions could cause actuator failure and result in serious injury, death or property damage.

Technical instructions for Comfodesk Foot Switch STF / STH / STG Contents 1 General..................................................2 1.1 Using these technical instructions.................................2 1.2 Explanation of symbols..........................................2 1.3 Correct usage..................................................2 1.4 Environmental conditions........................................2 2 Functional method..........................................2 3 Installation and commissioning................................3 3.1 Components supplied............................................3 3.2 Installation...................................................3 3.3 Connection...................................................3 4 Operation...............................................4 4.1 Operation without memory function................................4 4.2 Operation with memory function..................................4 5 Servicing and maintenance....................................5 5.1 Maintenance..................................................5 5.2 Servicing.....................................................5 5.3 Guarantee....................................................5 5.4 Disposal......................................................5 5.5 Liability......................................................6 6 Technical data............................................6 7 Fault locating and clearance..................................6 Compliance with standards EN 60601-1 EN 60335-1 UL 2601-1 SKF Actuations System (Liestal) AG Oristalstrasse 97 CH-4410 Liestal, Switzerland Phone +41/ 61/ 925 41 11 Fax +41/ 61/ 921 37 04 Email actuators@skf.com 531e2950_03/01

1 General 1.1 Using these technical instructions The technical instructions are intended for design engineers who are using this Magnetic product in their applications, and for installation engineers who are working with the product. The technical instructions contain all relevant information about this Magnetic product, and are subject to alteration in the interests of technological progress. Please read the technical instructions carefully and observe the safety instructions. The technical instructions can also be used to produce the operating manual for the end product. This symbol indicates operations and conditions which may pose a risk to persons or objects. Observe these instructions carefully! This symbol identifies information and useful notes for the user. The switch must not be subjected to poor weather conditions. No equipment should be operated in an atmosphere where there is a risk of explosion. 1.2 Explanation of symbols The technical instructions identify possible dangers and important information using symbols next to the relevant text. 1.3 Correct usage The foot switch, in one-way to five-way versions, is used to operate between 1 and a maximum of 5 linear drives. It is intended for use with the following Magnetic drives and control units: STF: SEM1Control (for Ecomag) KOM1/3 Control Matrix MAX62/63/64/65 Drive Telesmart TXG Drive ZVB Distribution Box, SPP Blocking Device STG: KOM2/4 Control ZVB Distribution Box STH: KOM6 Control ZVB Distribution Box, SPP Blocking Device The foot switch is intended for interior applications only. 1.4 Environmental conditions Operation: Temperature 0 C to 40 C Air humidity max. 85% Storage/transportation: Temperature -20 C to 60 C Air humidity max. 95% 2 Functional method A pair of pushbuttons is fitted on the foot switch for each drive to be controlled. The function in question is identified using the relevant symbols. Pressing on one of the pushbuttons initiates drive operation. The drive will run for as long as the button is held down. 531d2950_03/01 Magnetic The Linear Drives Company Page 2/6

3 Installation and commissioning 3.1 Components supplied The foot switch comprises 1 to 5 pushbutton pairs, with connected cable set. Options Expanding threaded inserts (ZBE-521122) Rubber stops (ZBE-135310) 3.2 Installation Free-standing installation with rubber stops The foot switch can be positioned on any level surface using the 4 rubber stops (see options). Ensure that the entire surface of the switch is locating correctly, otherwise operation may be impaired. Fixed installation For fixed installation there are 4 holes with embedded expanding threaded inserts. See fig. 1: Fig. 1 Installation Ensure that the plug is inserted into the correct socket, otherwise there may be a risk of the socket in the equipment being destroyed. Note the plug shape (arrows must be at the top). 3.3 Connection The foot switch line is connected to the relevant control unit, the blocking device (SPP), the distribution box (ZVB) or directly to the drive. Fig. 2 Insert plugs correctly Fig. 3 shows various connection options: All cables must be secured so that no forces are exerted on the plug connections on the foot switch. Stripped plugs and cables may destroy the foot switch! Cables must not be bent or clamped in any way. This may cause malfunctions due to a short circuit. Fig. 3 Connection options When connecting the foot switch to the relevant equipment, please observe the technical instructions for that equipment. 531d2950_03/01 Magnetic The Linear Drives Company Page 3/6

4 Operation 4.1 Operation without memory function Fig. 4 Operation without memory function The drive is controlled directly using the direction keys and. Key Drive is disengaged. Key Drive is engaged. The initialisation run is compulsory, otherwise the memory positions cannot be set up. 4.2 Operation with memory function Initialisation run Move the drive (drives) using the and keys on the foot switch in counter-load direction to the limit position (= reference position) Position 3 Position 2 Position 1 Fig. 5 Operation with memory function The drive is controlled directly using the direction keys and. Key Drive is disengaged. Key Drive is engaged. Keys 1, 2 and 3 on the foot switch are used to move to saved positions. 531d2950_03/01 Magnetic The Linear Drives Company Page 4/6

Saving memory positions 1. Use the keys to move all the drives into the position you want to save on key 1. (Hold down the relevant keys until the required position has been reached.) 2. Press the m key followed by (or simultaneously) key 1. There should be a gap of no longer than 0.5 seconds between pressing the two keys. The save procedure is confirmed by an acoustic signal. If no acoustic signal is sounded, repeat step 2. It may be that the 0.5 seconds has been exceeded. Repeat steps 1 to 3 for programming keys 2 and 3 as required. Retrieving memory positions To retrieve a memory position, press the corresponding key 1, 2 or 3 on the foot switch. If in time the memory positions are no longer correct, repeat the initialisation run. Hold down the key until the drives have reached their positions. All drives will move simultaneously to the saved position. If the drives have not been moved to the reference positions during the commissioning process, this can be triggered by pressing the memory pushbutton M. 5 Servicing and maintenance 5.1 Maintenance The plastic housing and the connected cable need to be checked periodically (every six months) for mechanical damage (cracks). For multi-way switches, a check must be conducted regularly to ensure that the fixing chamber between the individual switches is securely in position. Two fastening clamps are required per connection. Damaged parts should normally be replaced by Magnetic Customer Services. 5.2 Servicing Observe the special magnetic guidelines in ML 0111/87. Cleaning water with chemical additives must be PH neutral. Excessively acidic or alkaline cleaning water may destroy metal and plastic parts. High-pressure steam cleaners are not permitted for use. Only the cleaning agent isopropyl alcohol may be used for disinfecting by hand. Water protection, cleaning, disinfecting The foot switch must only be washed or disinfected with the plug properly connected. Protection classification IPx5 only applies when the unit is plugged in. Following contamination, the foot switch should be cleaned as soon as possible to prevent residues drying onto the switch. A damp cloth and water are suitable for cleaning by hand. The addition of isopropyl alcohol is permitted. 5.3 Guarantee Under the proviso that the operating conditions have been observed and that the equipment does not show any evidence of mechanical damage due to incorrect usage, a guarantee period of 12 months following delivery shall apply to all mechanical and electrical components. 5.4 Disposal Control components and drives can be returned to Magnetic AG, Liestal for disposal. 5.5 Liability Liability for the correct functioning of the equipment shall be transferred to the owner or user, in all cases where the equipment has been incorrectly installed, maintained or serviced by persons not representing Magnetic Service or if the equipment has been operated in a manner inconsistent with the correct usage. Magnetic Aktiengesellschaft shall accept no liability for damage caused by non-compliance with the instructions provided in this documentation. The instructions provided in this document shall not represent additions to the guarantee and liability conditions for the sales and delivery conditions from Magnetic Aktiengesellschaft. 531d2950_03/01 Magnetic The Linear Drives Company Page 5/6

The product is not subject to identification regulations conforming to CE or EMC guidelines. The necessary EMC measures must be taken for the end product by the manufacturer of the end product, in accordance with the installation conditions, wiring and control system, and checked for the intended use. The manufacturer of the machine or system shall be obliged to observe these regulations. 6 Technical data Technical data Foot switches STF/STH/STG Switching voltage 12V DC Switched current 50 ma Connection cable 2500 mm Ambient temperature 0/+40 C Protection type/ IPx5/Safety extra-low voltage classification Colour grey/blue Weight 500/1000/1500 g Fixing screws M5 x (8 + material thickness) 325 311,6 148.5 223 191 40 230 82 108,6 105 7 Fault elimination and troubleshooting Fault Cause Rectification No function Poor Check plug connection plug connections Fig. 5 Dimension drawing The instructions in customer-specific documentation must also be observed. Should it not be possible to rectify a fault, please contact Magnetic AG, Liestal. 531d2950_03/01 Magnetic The Linear Drives Company Page 6/6