The Flexible Endoscope Reprocessing Cycle: From Contamination to Decontamination

Similar documents
ON TRACK Reprocessing Inservice / Competency for GI Endoscopes (EVIS, EXERA, EXERA II)

Standards of Infection Control in Reprocessing of Flexible Gastrointestinal Endoscopes

Standards of Infection Control in Reprocessing of Flexible Gastrointestinal Endoscopes

Reprocessing Flexible Endoscopes Avoiding Reprocessing Errors Critical for Infection Prevention and Control

Standards of Infection Prevention in Reprocessing Flexible Gastrointestinal Endoscopes

Standard Operating Procedure

Back to Basics: Flexible Endoscope Processing LISA SPRUCE, DNP, RN, CNS-CP, CNOR, ACNS, ACNP, FAAN

In use test of a Washer-disinfector reprocessing of flexible endoscopes

National Endoscopy Programme. Decontamination Standards for Flexible Endoscopes

Flexible Endoscopes: The A,B,C s of Monitoring Manual Cleaning Efficacy!

Cleaning and High Level Disinfection of Semi-Critical Medical Devices

Christina Bradley Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham, UK

Reprocessing. Critical & Semi-Critical Equipment

REPROCESSING OF FLEXIBLE CYSTOSCOPES

MANY OF TODAY S SURGERIES USE MINIMALLY INVASIVE

Cleaning. By the end of this chapter, you will be able to: Introduction. Definitions. Chapter 9

University of Kentucky / UK HealthCare Policy and Procedure. Policy # A03-030

Administration of Meropenem For Child

PATIENT GUIDE. Care and Maintenance Drainage Frequency: Max. Drainage Volume: Dressing Option: Clinician s Signature: Every drainage Weekly

Gastroenterology Nursing

Patient Information Guide Morpheus CT Peripherally Inserted Central Catheter

Oxivir Tb and Accelerated Hydrogen Peroxide (AHP) Frequently Asked Questions

PATIENT GUIDE. Care and Maintenance Drainage Frequency: Max. Drainage Volume: Dressing Option: Clinician s Signature: Every drainage Weekly

ETD3 the new standard in endoscope reprocessing.

Clinical Guideline for: Aseptic Technique

Expert Opinion. on the efficacy of. EndoDet and EndoDis + EndoAct. for cleaning and disinfection of. Olympus Gastroscope Type GIF-2T200.

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

InfectIon PreventIon checklist for outpatient settings:

INFECTION CONTROL SURVEYOR WORKSHEET

Your Guide to Peritoneal Dialysis Module 3: Doing Peritoneal Dialysis at Home

SITE REQUIREMENTS AND INSTALLATION INSTRUCTIONS

Endoscope Tracking System

Quick Start Guide See Inside for Use and Safety Information

Infectious Waste Management Plan

1/9 INSTRUCTION MANUAL PLEASE READ BEFORE USE ENDOSCOPES

Cleaning and Sanitation

THE BASICS OF DECONTAMINATION

Infection Control in the Dental Practice through Proper Sterilization

20 GALLON WET DRY VACUUM

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

Body Art Facility Infection Prevention And Control Plan Guideline

PICCs and Midline Catheters

Bed Cleaning Procedure

ClikSTAR - Important facts about your new insulin delivery device.

VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised

Strategies for Effective Management of the Sterile Processing Department

Cleaning, Disinfection, and Sterilization. Basics of Infection Prevention 2-Day Mini-Course 2013

CARE HOMES AND NURSING HOMES

San josé OWNER S MANUAL

A new wave in instrument washing and disinfection Introducing the new HYDRIM G4 WD series

Care for your child s Central Venous Catheter (CVC)

Community Equipment Loan Stores Guidance on Decontamination BULLETIN

III-701 Urinary Catheterization/Bladder Irrigation Original Date: 3/1/1977 Last Review Date: 10/28/2004

FMI Listeria Action Plan for Retail Delis

POOL ROVER SERIES 2 ROBOTIC POOL CLEANER PRODUCT SETTINGS AND TROUBLESHOOTING GUIDE

Instructions and User Guide. Select Series: Vascular Access Ultrasound Training Models BPO100, BPBV110, BPP120, BPNB150. June 8, 2011 Rev 2.

National- Spencer Inc.

DASH KIT INSTALLATION

Transducer and System Care and Cleaning Koninklijke Philips N.V. All rights reserved. Published in USA.

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

2-SLICE COOL TOUCH TOASTER

Parallel Circuits Charles Lang

ClearView 100. Instruction Manual

Anti-decubitus Mattress 418E 516E - 820Z User's manual

Sample Collection Procedures for Insulating Fluid Samples

Record Cleaning Machine

Line to Refrigerator Ice/Water Dispenser

Recommendations for the Safe Use of Handling of Cytotoxic Drugs

ATS-SOI-5910 Page: 1 of 7. Approval Block. Prepared by: Signature Date. Evan Parnell 04 AUG Reviewed by: Signature Date. Brian Flynn 04 AUG 2014

Critical Care Therapy and Respiratory Care Section

Helping to protect you from exposure to hazardous drugs

URGENT FIELD CORRECTION. REVISED ED 530XT OPERATION MANUALS: Cleaning, Disinfection and Storage, CODE 202B D Operation

FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL

Alberta Health. Standards for Cleaning, Disinfection and Sterilization of Reusable Medical Devices for Health Care Facilities and Settings

Underwater Housing for Sony RX100 III, RX100 IV

MODEL G300 BRAKE BLEEDER

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

Cidex OPA Solution Training Checklist and Competency for Semi-Critical Medical Devices

Recommended Procedures for Use of YSI Water Quality Monitoring Instruments during Oil Spills

Your safety and the safety of others are very important.

Back Pack Sprayer. Operator's Manual MODELS MS - 40 MS - 50

Use and Disposal of Sharps

Instructions for Use. A-dec 500 Assistant s Instrumentation. Model 551

Medical Device Reprocessing: How to Ban the Biofilm!

Dentalaire Owner s Manual for all Dental Stations

Instructions for Use. Components of the GENOTROPIN PEN 12

CLEAN UP FOR VOMITING & DIARRHEAL EVENT IN RETAIL FOOD FACILITIES

AKRON EDUCTORS TROUBLESHOOTING GUIDE OPERATION & THEORY OF EDUCTORS GENERAL OPERATING AND MAINTENANCE INSTRUCTIONS

123 Industrial Loop Road Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

Class 5 to 7 Truck and Bus Hydraulic Brake System

Cantel Medical Overview

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

Clean Water: Supply side potable water, not wastewater. Gray Water/Sewage: Wastewater originating from a drain (sink, toilet, urinal).

Laparoscopic Instruments

Prevention and control of infection in care homes. Summary for staff

GB Tubulars RECOMMENDED PRACTICE For CASING on LOCATION

Cal Water 1961 Petra Lane, Placentia, CA (800) CAL-WATER (800) FAX: (714)

Sample Pharmacy CLEANING AND SANITIZING PROCEDURE P-304.1

Caring for a Tenckhoff Catheter

Transcription:

The Flexible Endoscope Reprocessing Cycle: From Contamination to Decontamination... Pam Boulet RN, BSN, CGRN Medivators Senior Clinical Specialist pboulet@medivators.com 504-390-4668 Reprocessing Guidelines Guidelines for reprocessing flexible endoscopes are published by federal regulatory agencies such as the CDC: Guideline for Disinfection and Sterilization in Healthcare Facilities, 2008 http://www.cdc.gov/hicpac/pdf/guidelines/disinfection_nov_2008.pdf Professional organizations have established guidelines for flexible endoscopes. Some are: Society of Gastroenterology Nurses and Associates (SGNA) - www.sgna.org Standards of Infection Control in Reprocessing of Flexible Gastrointestinal Endoscopes (2012) Association for Practitioners in Infection Control and Epidemiology (APIC) Guideline for infection prevention and control in flexible endoscopy, 2000 Alvarado CJ, Reichelderfer M, and the 1997, 1998, 1999 APIC Guidelines Committees. Am J Infect Control 2000;28:138-155. Association of Peri-Operative Registered Nurses (AORN) - www.aorn.org American Society for Gastrointestinal Endoscopy (ASGE) (Also known as SHEA paper) Multisociety guideline on reprocessing flexible gastrointestinal endoscopes: 2011 Endoscope manufacturer reprocessing guidelines for each endoscope (i.e. Olympus, Pentax, Fujinon, Karl Storz, etc.). Necessary Steps to High Level Disinfect Endoscopes Withdrawal of the Endoscope Pre-cleaning at Bedside Transport Enclosed Contaminated Scope to Reprocessing Area Leak Testing Manual Cleaning Rinsing with Water; Purging with Air High Level Disinfection Rinsing Air Drying & Alcohol Flush Storage or Set-up for Patient 1

Manual Cleaning Is it really that important? SGNA states, Manual cleaning of endoscopes is necessary prior to automated or manual disinfection. This is the most important step in removing the microbial burden from an endoscope. (SGNA, Standards of Infection Control in Reprocessing of Flexible Gastrointestinal Endoscopes, 2012., 14) Manual cleaning: -Reduces the number of microorganisms and organic load on an endoscope (bioburden). Reduces the potential of biofilm growth. Biofilms consist of colonies of organisms that form structures with potential to have maximum growth. Biofilms adhere to the internal channels of endoscopes. This growth potential is an important factor because they interfere with disinfection. -Reduces the burden on the high-level disinfectant. (i.e. Rapicide or Rapicide PA) - Starts at the bedside, immediately after withdrawal. Step 1 Pre-cleaning at Bedside 1) Immediately Wipe down scope s exterior with a detergent-soaked cloth like Intercept or with an Intercept Wipe. **Detergent solution should be diluted per manufacturer s label. ** Intercept Solution Dilution 1 oz = 1 full pump per 3 gallons of water Step 1 Pre-cleaning at Bedside continued 2) Suction detergent through the scope, then air. Alternate suctioning of air and detergent to create agitation. 3) If applicable, install the air/water cleaning adapter. Flush with water, then air, through air/water channel. 4) Clear the air and water channels according to the manufacturer s instructions. 2

Step 1 Pre-cleaning at Bedside continued 5) Flush detergent, then air through ANY SPECIAL FEATURE CHANNELS, such as auxiliary water inlet, elevator wire channel, etc. 6) Detach all removable parts and cleaning equipment and place in accessory bag. Step 1 Pre-cleaning at Bedside continued 7) Ensure water-resistant cap (soaking cap) is attached, if applicable. Step 2 Transport Enclosed Contaminated Scope to Reprocessing Area Contain the scope and transport to reprocessing area. 3

Step 3 Leak Testing Purpose: To detect a hole or leak in an endoscope. Why leak test? 1) To prevent cross contamination of patient matter or chemicals. 2) To prevent fluid invasion. 3) To prevent very costly & lengthy repair. Always: - Leak test after EVERY procedure and PRIOR to immersing the endoscope in any fluid. - Test for leaks according to the endoscope manufacturers instructions. Step 3 Leak Testing continued Leak test methods can be WET, DRY or AUTOMATIC DRY LEAK TEST Attach leak tester to scope. Squeeze bulb to level of desired pressurization. Confirm bending section has inflated slightly. Observe the gauge continuously for 90 seconds. While observing the gauge, angulate the scope fully in each direction at least once. A steady drop in pressure on the gauge indicates a leak. If this fails, check integrity of water resistant cap connection and reconnect, if necessary. 4

Step 3 Leak Testing continued WET LEAK TEST Remove all valves and/or buttons from the endoscope. Turn on air supply (i.e. maintenance unit or light source). Depress pin in leak tester connector to ensure all is flowing through tubing. Attach the leak tester connection to the scope. Confirm bending section has inflated slightly. Carefully place the scope in a basin of water full enough to completely cover the scope, ensuring the knobs are covered. Observe the scope for at least 90 seconds. Angulate the scope fully in each direction at least once during the observation period. Depress each of the switches to observe for leaks. If testing a duodenoscope, activate the elevator wire both up and down as well. A steady stream of bubbles indicates a leak. If a leak is found, keep scope on leak tester and finish manual cleaning. Bubbles escaping at an irregular rate usually indicates trapped air. If no leak found, remove the scope from the basin. Turn off the air supply. Unplug the leak tester from the air supply, and release all of the air pressure in the scope. Remove the leak test connector from the scope. Step 3 Leak Testing continued VERISCAN LT AUTOMATIC LEAK TEST The Veriscan LT features: Detect leaks with 99% accuracy. Lowers cross-contamination risk due to undetected leaks. Detects endoscope leaks early when repairs are minor and less costly. Unsurpassed leak detection compared to visual observation methods. Dry endoscope leak test no fluid submersion required. Utilizes highly sensitive, innovative leak sensing technology. Compatible will all flexible endoscopes. Simple to operate. Ensures compliance with endoscope leak test protocols. Provides consistent, repeatable endoscope leak testing. Printed confirmation of leak test results. Computerized endoscope leak test records and reports. Step 3 Leak Testing continued - If a leak is found, the endoscope needs to be taken out of service and sent for repairs. Follow the manufacturer s instructions for decontamination to avoid further damage. - For smaller leaks, the Medivators Advantage and DSD-LT reprocessors can be used to reprocess the endoscope prior to being sent for repair by keeping the scope pressurized with air for the entire reprocessing cycle to avoid fluid invasion. - Contaminated scopes should never be placed in a suitcase and sent off for repair. 5

Step 4 Manual Cleaning BRUSH then FLUSH BRUSH - Scrub, brush, and soak scope and all removable parts. - Ensure the correct brush size is being used. - Do not reuse single-use brushes. - Valves also should be depressed and the exposed areas brushed. - Immerse scope in freshly prepared detergent solution like Intercept. - Thoroughly clean exterior of endoscope. - Brush distal tip and elevator, if applicable. - Brush the entire suction/biopsy channel system. - Clean brush each time it exits distal tip and umbilical cord. - Brushing should be repeated until no debris is visible on the brush. Step 4 Manual Cleaning BRUSH then FLUSH FLUSH either manually or with SCOPE BUDDY, an Endoscope Flushing Aid. Flush: 1 st ) with detergent 2 nd ) purge with air 3 rd ) with clean water 4 th ) purge with air Step 4 Manual Cleaning Flush all channels with Detergent, followed by an air purge: 1. Attach cleaning adapters or Scope Buddy connectors and channel plugs to endoscope. 2. For manual flushing, push the required amount of Intercept Detergent solution through all channels (suction, air/water, accessory water, elevator wire). 3. For Scope Buddy flushing, push the START button. 4. Remove filter from detergent solution and flush air through all channels to purge detergent from channels. 6

Step 5 Rinsing with Water; Purging with Air FLUSH all channels with clean water; then purge with air. -The scope s exterior and removable parts need to be rinsed thoroughly under water to remove residual detergent. - All internal channels need to be flushed with water. - This can be accomplished with SCOPE BUDDY by placing the intake filter in clean water and pressing START. - If no SCOPE BUDDY, then manual flushing of all channels with clean water needs to be done (including auxiliary-water/elevator-wire, if applicable). -Remove water from all channels by purging with air. -Use a soft, lint-free cloth to remove excess moisture from the exterior of endoscope and cleaning accessories in reparation for disinfection. Step 6 High Level Disinfection Can be accomplished by: Placing endoscope in a Medivators Endoscope Reprocessor --------------- OR --------------- Manually Disinfect 7

Medivators Automated Endoscope Reprocessors For AERs using aldehyde-based high level disinfectants, test disinfectant concentration (MEC or MRC) using a test strip and document result. Place endoscope in the reprocessor and attach all channel hookups. If applicable, verify disinfectant temperature is within required range. Place valves and other removable parts into the accessory bag. Tuck accessory bag under scope in basin to prevent floating. Enter in AER or log all ID data. Start endoscope reprocessor. Step 6 High Level Disinfection Step 6 High Level Disinfection continued Medivators Automated Endoscope Reprocessors For AERs using Rapicide PA, test high level disinfectant potency (MEC or MRC) with test strip at the end of cycle and document. Step 6 High Level Disinfection continued Steps to Manually Disinfect Endoscopes: Completely immerse the clean, rinsed, and water-purged endoscope and all removable parts in a FDA-approved room temperature HDL. Ensure channel plug and irrigation tube are attached to the endoscope. Use syringe to completely fill air, water, and suction channels with disinfectant solution until no bubbles are seen. If applicable, flush disinfectant solution into elevator-wire channel and accessory water channel. While the endoscope is immersed, disconnect cleaning accessories. Soak all equipment according to the disinfectant manufacturer s required time and temperature. Use a timer to measure exact contact time. Manually document all ID data. 8

Step 7 Rinsing with Water Steps to Manually Rinse Endoscopes Reconnect channel plug and irrigation tube. Use syringe to inject air in order to remove disinfectant from air, water, and suction channel and, if applicable, from elevator-wire channel and auxiliary water channel. Remove endoscope from disinfectant. Immerse endoscope and detached parts in water. Thoroughly rinse all external surfaces and removable parts with water to remove all traces of the disinfectant. Use a syringe to inject water to rinse disinfectant from all internal channels. Rinse with fresh water for the required amount of times needed for HLD used, per manufacturer s DFU. Step 8 Air Drying and Alcohol Flush 1) Remove endoscope from rinse water. 2) Use syringe and irrigation tube to inject AIR through air, water, and suction channels, and from elevator-wire channel and/or auxiliary-water channel, expelling the rinse water. 3) Use syringe and irrigation tube to flush 70% ALCOHOL through air, water, and suction channels, and from elevator-wire channel and/or auxiliary-water channel to facilitate drying. 4) Purge all channels with air. 5) Disconnect all accessories from the endoscope. 6) Dry endoscope and accessories with a soft, lint-free cloth. 7) Ensure equipment is completely dry prior to storage. Note: When using a Medivators Automated Endoscope Reprocessor (AER) You can eliminate the following manual labor-intensive and timeconsuming steps because they are done automatically: Manual High Level Disinfection Manual Rinsing Manual Air Drying & Alcohol Flush This provides: Safety to Staff and Consistency for Our Patients! 9

Step 9 Storage or Set-Up for Patient For Storage: Remove all removable parts, including water-resistant cap. Hang endoscopes vertically in a ventilated area. Do not replace removable parts until immediately prior to scope use. The Flexible Endoscope Reprocessing Cycle: From Contamination to Decontamination. The Endoscope Cycle is complete It has moved from Contamination to Decontamination.. 10

Medivators products provide solutions for your endoscope reprocessing needs the way it should be. Bedside pre-cleaning Medivators detergents and wipes are specifically designed for endoscopes, offering the most technologically advanced detergent called Intercept. Leak testing an important step for eliminating cross-contamination and reducing endoscope leak-related repair costs, the Veriscan is an automated leak tester with 99% detection of endoscope leaks. Supplemental leak testing is performed in certain Medivators reprocessors. Manual cleaning Brush with Medivators PULL THRU & Stubby Brush Combo Disposable. Effective on lumens 2.8mm - 5mm in size. Significantly improves efficiency over traditional brushes. Smooth, non-abrasive, non-damaging, and time-saving method to pre-clean the endoscope in a single pass. Patented design provides a complete circumferential seal in the lumen tube. 11

Manual cleaning Flush with Medivators detergents for superior removal of biological and organic soils. Eliminate manual flushing with the Scope Buddy automated flushing aid. High-level Disinfection whether you need a counter-top style to reprocess one or two endoscopes at a time, or a free-standing, dual basin version capable of reprocessing multiple endoscopes, the Medivators line of Automated Endoscope Reprocessors provide unsurpassed infection control and the lowest cost of ownership. Medivators CER OPTIMA Medivators DSD EDGE High-level Disinfection Medivators DSD-201LT 12

High-level Disinfection Medivators Advantage Plus High-level Disinfectants Rapicide & Rapicide Test Strips Disinfects in 5 minutes at 35 C (95 F). Effectively kills TB, hepatitis viruses, and Clostridium difficile. Up to 28-day reuse life. Only 2 rinses required. Easy to read Rapicide Test Strips accurately measure the Rapicide solution for the minimum recommended concentration (MRC). High-level Disinfectants Rapicide PA & Rapicide PA Test Strips Disinfects in 5 minutes at 30 C. Effectively kills TB, hepatitis viruses, Clostridium difficile, VRE, and MRSA. Single-use, non-aldehyde chemistry base. Easy to read Rapicide PA Test Strips accurately measure the minimum recommended concentration (MRC) of Rapicide PA. 13

Hookups for Medivators AERs Hookups provide the critical connection between the endoscope and the automated endoscope reprocessor (AER). Largest array of endoscope hookups, more than any other manufacturer. Examples include: gastroscopes, colonoscopes, EUS scopes, cystoscopes, bronchoscopes, twin channel, dilators, and TEE probes. Interactive Hookup Guide can be found at http://www.minntech.com/medivators/hookuplookup/ Endo SmartCap Procedure Room Products EndoGator Irrigation Tubing 1 st completely disposable, 24-hour use alternative to the reusable water bottle in GI Endoscopy. Design minimizes infection control risks that are associated with manual cleaning and sterilization. 1 st cost-effective, completely disposable irrigation alternative to reusable irrigation tubing for GI Endoscopy. Universally compatible with any GI Endoscope or sterile water bottle. Sterile 24-hour disposable tubing. Eliminates manual cleaning and reprocessing of reusable tubing. DEFENDO Sterile Single Use Valves Procedure Room Products Verifind Protein Detection Kit Eliminates manual cleaning and reprocessing of reusable valves. Helps create consistent practices. Reduces the potential for errors. 10-second protein detection time (blood, mucous, saliva, serum, skin/tissue fragments). 1 microgram sensitivity. Visual color change indicator. Minimal training needed. 14

The Flexible Endoscope Reprocessing Cycle: From Contamination to Decontamination ALWAYS REMEMBER: To get your colonoscopy with a scope that has gone from Contamination to Decontamination. --------------- If you re not sure that the scope has been properly decontaminated, then you might need to check for yourself that is YOU MIGHT NEED TO THE END!! QUESTIONS??? Pam Boulet RN, BSN, CGRN Medivators Senior Clinical Specialist pboulet@medivators.com 504-390-4668 THANK YOU!!! 15