Norwegian Institute for Water Research. Page: 1 of 11

Similar documents
Marine Microbiological Analysis of Ballast Water Samples

BACTERIAL ENUMERATION

UTILIZATION of PLASMA ACTIVATED WATER in Biotechnology, Pharmacology and Medicine. JSC TECHNOSYSTEM-ECO Moscow, Russia April, 2009

MTT Cell Proliferation Assay

Testing Surface Disinfectants

National Food Safety Standard Food microbiological examination: Aerobic plate count

Quantifying Bacterial Concentration using a Calibrated Growth Curve

Current methods: late results (2 to 3 days) contamination spread in the distribution system water consumed

ENUMERATION OF MICROORGANISMS. To learn the different techniques used to count the number of microorganisms in a sample.

Equipment. Reagent reconstitution and storage

ADP/ATP Ratio Assay Kit (Bioluminescent)

Effects of Antibiotics on Bacterial Growth and Protein Synthesis: Student Laboratory Manual

INTERNATIONAL CONVENTION FOR THE CONTROL AND MANAGEMENT OF SHIPS' BALLAST WATER AND SEDIMENTS, 2004

ATP as an indicator of microbiological activity in tap water

EFFECTIVE NEW TECHNOLOGIES FOR THE ASSESSMENT OF COMPLIANCE WITH THE BALLAST WATER MANAGEMENT CONVENTION FINAL REPORT 1/90

Contaminant. Publication Order Number. EPA Publication Number. Method. Date. Source of Method. Total Coliforms

The RWO Ballast Water Treatment System

Microbiology BIOL 275 DILUTIONS

Regulation concerning the prevention of transfer of alien organisms via ballast water and sediments from ships (the Ballast Water Regulation)

ANNEX 4 RESOLUTION MEPC.174(58) Adopted on 10 October 2008 GUIDELINES FOR APPROVAL OF BALLAST WATER MANAGEMENT SYSTEMS (G8)

Testing Waste Water for Fecal Coliforms and/or E.coli using Colilert and Colilert -18 & Quanti-Tray

Lab Exercise 3: Media, incubation, and aseptic technique

Instructions. Torpedo sirna. Material. Important Guidelines. Specifications. Quality Control

Creatine Kinase (CK) Enzymatic Assay Kit Manual Catalog #:

NUTRITION AND GROWTH OF BACTERIA

Filtration and UV treatment for ships ballast water management water quality challenges and UV-dose requirements

Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater

Phosphate Assay Kit (Colorimetric)

Related topics: Application Note 27 Data Analysis of Tube Formation Assays.

Metabolism Dr.kareema Amine Al-Khafaji Assistant professor in microbiology, and dermatologist Babylon University, College of Medicine, Department of

In use test of a Washer-disinfector reprocessing of flexible endoscopes

Seahorse XF Cell Mito Stress Test Kit

Measuring Cell Viability/Cytotoxicity: Cell Counting Kit-F

Bacterial Transformation with Green Fluorescent Protein. Table of Contents Fall 2012

Ballast Water Management WÄRTSILÄ AQUARIUS BALLAST WATER MANAGEMENT SYSTEMS

IgM ELISA. For the quantitative determination of IgM in human serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.

Methods of Verification of Cleaning in CSSD. Dr. Winfried Michels Mechelen Oct.2012

Microbiological Evaluation of the STI Series 2000 Medical Waste Treatment Process

Fighting the Battles: Conducting a Clinical Assay

protocol handbook 3D cell culture mimsys G hydrogel

Ballast Water Management Regulations and Challenges

Environmental Monitoring of Clean Rooms

Lecture Objectives: Why study microbiology? What is microbiology? Roots of microbiology

through 2.4. Perform the analysis for beer getting into the filter and coming out from the filter.

CellTiter-Fluor Cell Viability Assay

THE UNIVERSITY OF NEWCASTLE- DISCIPLINE OF MEDICAL BIOCHEMISTRY. STANDARD OPERATING PROCEDURE PROCEDURE NO: GLP 079 MOD: 1st Issue Page: 1 of 7

MycoAlert Mycoplasma Detection Kit

Quality Assurance (QA) & Quality Control (QC)

Aseptic Technique. A GMP/GTP Training Module

Laboratory Exercise # 11: Differentiation of the Species Staphylococcus and Streptococcus

Transfection reagent for visualizing lipofection with DNA. For ordering information, MSDS, publications and application notes see

DETECTION OF BACTERIAL MOTILITY. To demonstrate bacterial motility by microscopic and macroscopic techniques.

Innovation and Progress in Water Treatment Technology

Gamma Sterilisation Validation according to ISO Sterilising dose -

Medical Microbiology Culture Media :

Inc. Wuhan. Quantity Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4 Standard (liquid) 2

PRODUCT INFORMATION...

MICROSCOPY OF LIVING MICROBES

Laboratory 5: Properties of Enzymes

Test Method for the Continuous Reduction of Bacterial Contamination on Copper Alloy Surfaces

Transformation Protocol

Epinephrine/Norepinephrine ELISA Kit

Frozen-EZ Yeast Transformation II Catalog No. T2001

Detecting primitive hematopoietic stem cells in total nucleated and mononuclear cell fractions from umbilical cord blood segments and units

Hydrogen Peroxide Cell-Based Assay Kit

Biologic Air-Borne Particle Detection, Sampling, and Identification

Evaluation of water stress of selected cases from water re-use or saving scenario s tested in SP5

Microbiological Testing of the Sawyer Mini Filter. 16 December Summary

Annexin V-FITC Apoptosis Detection Kit

Induction of Enzyme Activity in Bacteria:The Lac Operon. Preparation for Laboratory: Web Tutorial - Lac Operon - submit questions

Enzymes: Practice Questions #1

One Shot TOP10 Competent Cells

Environmental Monitoring

Result: COMPLETE Report Date: 08-OCT-2012

Catalytic Activity of Enzymes

Epstein Barr Virus (Human Herpes virus 4) nonglycosylated membrane protein (BNRF1) gene. genesig Advanced Kit. DNA testing

Fast, easy and effective transfection reagent for mammalian cells

Steatosis Colorimetric Assay Kit

Expert Opinion. on the efficacy of. EndoDet and EndoDis + EndoAct. for cleaning and disinfection of. Olympus Gastroscope Type GIF-2T200.

TransIT Transfection Reagent

Quality Assurance in Blood Cell Labelling

Data Sheet. PD-L1:B7-1[Biotinylated] Inhibitor Screening Assay Kit Catalog # Size: 96 reactions

Human Herpes Virus 4 (Epstein Barr)

Luciferase Reporter Assay Kit User Manual

Agencourt RNAdvance Blood Kit for Free Circulating DNA and mirna/rna Isolation from μL of Plasma and Serum

User Manual. CelluLyser Lysis and cdna Synthesis Kit. Version 1.4 Oct 2012 From cells to cdna in one tube

Application Sheet for Rivaroxaban (Xarelto ) Standard Range with. BIOPHEN Heparin LRT (#221011/221013) RUO

Biology 29 Cell Structure and Function Spring, 2009 Springer LABORATORY 2:CHLOROPLASTS AND PHOTOREDUCTION

Biological Sciences Initiative

Human Free Testosterone(F-TESTO) ELISA Kit

Human Luteinizing Hormone (LH) Custom Kit

Radius 24-Well Cell Migration Assay (Laminin Coated)

Glycolysis Cell-Based Assay Kit

Plant Genomic DNA Extraction using CTAB

Primary producers. Primary consumers (herbivores) Secondary consumers (carnivores) Tertiary consumers

Application Note. Single Cell PCR Preparation

Western Blot Analysis with Cell Samples Grown in Channel-µ-Slides

- WATER DAMAGE RESTORATION -

Contribution of picoplankton to the total particulate organic carbon (POC) concentration in the eastern South Pacific

Mouse IgM ELISA. Cat. No. KT-407 K-ASSAY. For the quantitative determination of IgM in mouse biological samples. For Research Use Only. 1 Rev.

Transcription:

Norwegian Institute for Water Research. Page: 1 of 11

Date: 09.12.2013 Journal no.: 1894/13 1.1 Introduction... 3 1.2 Objectives... 3 1.3 Material and methods... 3 1.3.1 Description of the instrument to be evaluated... 3 1.3.2 Testing protocol... 4 1.3.3 Analysis methods... 5 1.4 Results and discussion... 5 1.5 Conclusion...10 Appendix 1: ATP procedure from SGS/Aquatools...11 Project Manager Stephanie Delacroix Research Manager Helge Liltved NIVA Region South NIVA Region East NIVA Region West NIVA Region Mid-Norway Marine Research Station Jon Lilletuns vei 3 Sandvikaveien 59 Thormøhlens gt 53D Høgskoleringen 9 Solbergstrand 4879 Grimstad 2312 Ottestad 5006 Bergen 7034 Trondheim 1440 Drøbak Norway Norway Norway Norway Norway Norsk institutt for vannforskning www.niva.no Page 2 of 11

A research project have been conducted by the Federal German Hydrographic and Maritime Agency - BSH, Hamburg, Germany, the SGS Institut Fresenius GmbH, Taunusstein, Germany to develop an analytical method for treated ballast water based on ATP measurements. The intention is to use the the test kit for a rapid onboard analysis to indicate compliance with the D-2 regulation from International Maritime Organisation (IMO). According to the IMO Ballast Water Convention, all ships have to disinfect their ballast water to ensure a maximum viable organism density for 50µm organisms, 10-50µm organisms and bacteria during discharge (Table 1). As an independent third part, Norwegian Institute for Water Research (NIVA) has tested the ATP instrument developed by SGS in the laboratory. NIVA has 7 years of experience in ballast water treatment system testing at its full scale test facility and laboratories located in Norway. The results of the tests of the ATP instrument are presented in this report. Table 1. Required biological water quality in influent water and treated water during discharge according to IMO regulation D-2 (BWM Convention). In treated on discharge Organism group Influent water (Regulation D-2) 50 µm min. dimension 10-50 µm min. dimension Pref. 10 6 m -3, 10 5 m -3 Min. 5 species from 3 diff. phyla/divisions 10 4 ml -1, 10 3 ml -1 Min. 5 species from 3 diff. phyla/divisions <10 viable organisms per m 3 <10 viable organisms per ml Heterotrophic bacteria 10 4 cfu ml -1 - Escherichia coli - < 250cfu/100 ml Intestinal enterococci - <100 cfu/100 ml Vibrio Cholerae - <1 cfu/100 ml The main objective of this laboratory test was to do a preliminary validation of the ATP analytical procedure developed by SGS. The test was done by comparing the organism count results obtained by the ATP instrument to the results obtained by NIVA s standard methods applied for Ballast Water Treatment System testing according to IMO guidelines. Cultivated organisms and indigenous organisms from the Oslo fjord were used. The ATP instrument from SGS was tested in laboratory by generating ATP calibration curves for 10-50µm organism (Tetraselmis suecica) and for 50µm organisms (Artemia franciscana and rotatoria). 1.3.1 Description of the instrument to be evaluated The ATP instrument submitted by SGS was developed by Aquatools (France) for determining the number of viable organisms in ballast water sample based on quantification of the total adenosine triphosphate (tatp) present in the sample. ATP is a coenzyme used as an energy carrier in the cells of all known organisms. Therefore ATP is used as an indicator of metabolically active cells. ATP is 3/11

detected with a luminometer by measuring the luminescence produced by the firefly enzyme luciferase when it reacts with ATP. The ATP analysis procedure is based on the extraction of the intracellular ATP by destruction of the cell wall and lysis of the cell content. The luminescent signal is generated by reaction of the enzyme with the extracted ATP. The luminescent signal is proportional to the amount of ATP present, which is proportional to the number of organisms in the sample. However, the cellular ATP content might vary considerably from species to species and from life stage to life stage within a same species. The test kit is presented in Figure 1 and is constituted of: - Luminase, UltraCheck, UltraLyse, UltraLute droppers - Disposable grinding tubes with bead mixture - Grinding device for disposable sample tubes - Luminometer tube - Luminometer with calculation software Figure 1 Picture of the luminometer (on right) for ATP measurement developed by Aquatools with the grinding device (on left) to mix the sample in the grinding tube containing beads for ATP extraction. 1.3.2 Test protocol Test organisms used were collected from NIVA s cultures (Artemia franciscana for 50µm organism and Tetraselmis sueccica for 10-50µm organism). Samples with indigenous organisms 50µm were collected from the surface water of Oslofjord. The initial organism concentrations were determined by microscopy for 50µm or by coulter counter for Tetraselmis suecica, as described in section 1.3.3. From these initial samples, serial dilutions were generated. The initial algal concentration required by IMO in challenge test water for ballast water treatment system testing is 1,000 cell/ml. Therefore, five dilution series were prepared in sterilised aged filtered 60m deep seawater from Oslofjord to cover the organism density range of approximately 5,000-10 cell/ml for 10-50µm organism. To determine the appropriate dilution factor according to the initial 4/11

algal concentration, the initial algal concentration was estimated by using a coulter counter, as described in section 1.3.3. For 50µm organism, Artemia franciscana or indigenous organism were carefully collected individually with a pipette under microscope and transferred to 1mL of sterilised aged filtered 60m deep seawater from Oslofjord. In this way, 7 samples were prepared with 50µm organism densities from 1 to 15 organisms/ml. 1mL samples were prepared as 1mL volume is required for the ATP analysis. Each sample was analyzed in duplicate or triplicate with the ATP instrument from SGS to generate an ATP calibration curve for each organism size group. The initial organism densities in the undiluted samples were confirmed by using microscopy for 50µm organism and by the plate count method for Tetraselmis suecica. 1.3.3 Analytical methods ATP method: the measurement was performed according to the supplier s procedure provided by SGS. The analytical method is detailed in Appendix 1. The results were given as Relative Light Unit (RLU). Determination of the initial algal density: The initial algal concentration was measured with a coulter counter (Beckman Multisizer 3, Beckman-Coulter, USA) with a 100 µm aperture. Particles within 5-15µm in spherical diameter were counted in 300 size intervals. A sample was checked under microscope to assess the condition of the culture to assume that most of the particles counted were viable cells. The algal culture was in the exponential growth phase. Culture method for counting viable cells of Tetraselmis suecica: A cultivation method for enumeration of viable and reproducible Tetraselmis suecica was used by plating the samples on agar plates. 100 µl of samples was spread on a seawater agar growth medium and incubated in constant light for 72 hours at 20 C. Colonies of Tetraselmis sp. were observed by viewing agar plates in stereo microscope at 16x magnification. The procedure has a detection limit of 10 cells/ml. Identification and quantification of organisms 50 m: Samples for organisms 50 µm were inspected using a stereo loupe at 10-40x magnification. Viable organisms were counted and identified based on motility and integrity according to OECD (1985): OECD Test Guideline for Testing of Chemicals 202, Daphnia sp. acute immobilisation test and reproduction test. The laboratory test was performed on the 24 th and 25 th of September 2013. The calibration curve of the ATP instrument was generated for 10-50µm organism (Tetraselmis suecica culture) as presented in Figure 1 and for 50µm organism (Artemia franciscana culture and indigenous copepods from Oslofjord) as presented in Figure 2 and Figure 3. All samples were collected, diluted and analysed the same day than sampling day. ATP calibration curve for Tetraselmis suecica The initial concentration of the undiluted algal culture sample was analysed by plate count method in triplicate. After the incubation period, there were observed 2840, 2850 and 3070 cells/ml in each of the triplicate plates, giving an initial average algal concentration of 2920 cell/ml. To cover an algal concentration range from approximately 5,000 to 10 cell/ml, a serial dilution was prepared stepwise with a dilution factor of 2 as indicated in the Table 2. The ATP was measured in duplicate only for each dilution step due to limited available material for ATP analysis. The ATP average results are presented for all samples in the Table 2. The ATP results varied from 40 RLU to 139 RLU, with a 5/11

relative high ATP average in the sterile seawater of 28 RLU. The calibration curve on logarithmic scale (Figure 1a) shows a correlation between the algal concentration and the ATP results with a correlation factor R 2 of 0.77. However, by excluding the deviating results from the samples diluted 4 times (730 cell/ml), the correlation factor was very good with R 2 of 0.98 (Figure 1b). The reason of the deviating results is difficult to explain, but highly diluted samples will tend to be more inaccurate than samples with lower dilution factors. According to the supplier, the luminase solution is approved for luminescent signal above 5,000 RLU. It was measured 10,253 RLU in the luminase solution used for this test. In this test, the ATP instrument could not be used to measure the ATP in samples with lower algal densities than 183 cell/ml, due to the relatively high ATP signal in sterile seawater used as blank. Table 2. ATP measurement and dilution operations for Tetraselmis suecica samples. SW: sterile seawater. Algal concentration Dilution factor Dilution operation ATP Measurements (RLU) cell/ml - 1 2 Average 2920 - - 140 138 139 1460 2 2 ml culture in 2 ml SW 84 88 86 730 4 2 ml of 2xdilution in 2 ml SW 107 100 104 365 8 2mL of 4x dilution in 2 ml SW 39 61 50 183 16 2 ml of 8x dilution in 2 ml SW 41 38 40 Blank - - 28 27 28 6/11

ATP measurements (RLU) ATP measurements (RLU) 1000 R² = 0,7677 100 10 1 1 10 100 1000 10000 Tetraselmis suecica (cell/ml) Figure 1a. ATP calibration curve for Tetraselmis suecica monoculture for all samples. 1000 R² = 0,9778 100 10 1 1 10 100 1000 10000 Tetraselmis suecica (cell/ml) Figure 1b. ATP calibration curve for Tetraselmis suecica monoculture, excluding the samples diluted four times. ATP calibration curve for Artemia franciscana culture A total of seven 1mL samples were prepared containing a concentration of Artemia sp. between 1 and 15 per ml. For each sample, 3 measurements of ATP were performed. The average and standard deviation of the ATP measurements are presented in the Table 2. The ATP results varied from 549 RLU to 9075 RLU for densities from 1 to 15 organism/ml, respectively. The ATP average in the 7/11

ATP measurements (RLU) sterile seawater used as blank was relatively low with 40 RLU, as average value of triplicates. The ATP calibration curve for Artemia sp. is presented in the Figure 2 in logarithmic scale. The correlation between the Artemia concentration and the ATP results was very good with a correlation factor R 2 of 0.98. The results show that the ATP instrument would be able to detect 1 Artemia in 1 ml of sample. IMO regulation requires to collect 1m 3 of ballast water for each sample by sieving through a 35µm plankton net. If only 1 Artemia is present in the 1m 3 of ballast water, the ATP instrument will be able to detect it after filtration of the sieved sample to 1 ml necessary for ATP analysis. Table 2. ATP values for single analyses and averages, including standard deviations, for Artemia samples.. Number of ATP measurements (RLU) Artemia/mL 1 2 3 Average Stdev 1 544 538 564 549 14 2 956 890 1143 996 131 3 1157 1157 1171 1162 8 4 1608 1695 1725 1676 61 8 5334 5092 5178 5201 123 10 7227 6912 6916 7018 181 15 9229 8819 9176 9075 223 Blank 36 43 42 40 4 Luminase 18500 - - 10000 1000 R² = 0,977 100 10 1 1 10 100 Artemia franciscana/ml Figure 2. ATP calibration curve for Artemia samples. ATP calibration curve for indigenous copepods from Oslofjord A total of 6 samples were prepared containing a concentration of indigenous copepods from Oslofjord between 1 and 15 per ml. For each sample, 3 measurements of ATP were performed. The average and standard deviation of the ATP measurements are presented in the Table 3. The ATP results varied from 759 RLU to 3427 RLU for densities from 1 to 15 organism/ml, respectively. The ATP average in the sterile seawater used as blank was low, with 12 RLU as average of triplicates. The ATP calibration curve is presented in the Figure 3 in logarithmic scale. The correlation between the copepod concentration and the ATP results was relatively good with a correlation factor R 2 of 0.84. The reason for lower correlation factor compared to the correlation factor obtained with Artemia is 8/11

ATP measuremenst (RLU) probably due to analytical challenges. Since the copepods are smaller (not easily visible with bare eyes) than Artemia, it was difficult to ensure the transfer of all of them to the bead beating tube. Even if the emptied tubes were controlled under microscope after each transfer to the bead beating tube. This might explain the deviating results for the samples with 2 and 4 copepods/ml. The copepods should have been collected individually under microscope and transferred directly to a bead beating tube, but due to lack of ATP analysis material, the experiment couldn t be repeated. However, the results indicate that the ATP instrument would be able to detect only 1 copepod present in 1 ml of sample. IMO requires to collect 1m 3 of ballast water for each sample by sieving through a 35µm plankton net. If only 1 copepod is present in the 1m 3 of ballast water, the ATP instrument would be able to detect it if it is possible to collect the only one copepod from the sieved sample to the 1 ml necessary for ATP analysis. Table 3. ATP values for single analyses and averages, including standard deviations, for copepods in samples collected from Oslofjord. Number of RLU copepods/ml 1 2 3 Average Stdev 1 831 733 714 759 63 2 359 430 626 472 138 4 315 210 202 242 63 8 1164 1185 1166 1172 12 10 1577 2472 2240 2096 464 15 3443 3477 3361 3427 60 Blank 4 13 19 12 8 Luminase 16717 10000 1000 R² = 0,8446 100 10 1 1 10 100 Number of indigeneous copepods per ml Figure 3. ATP calibration curve for indigeneous copepods from Oslofjord. 9/11

In conclusion, the correlations between the ATP results and the organism concentration based on standard counts were good for 50µm organism with both surrogate standard test organism (R2>0.97) and indigenous organisms (R2>0.84). Moreover, the luminescent signal for samples with only 1 organism/ml was significantly higher than the signal detected in the sterile seawater which was used as blank. This indicates that the detection limit might be below the maximum concentration of 10 organism/m3 required by IMO regulation D-2. However, this requires that the few viable organisms present in the ballast water sample can be collected and resuspended in the 1mL artificial seawater solution before the grinding and ATP extraction. The ATP measurements were performed with samples containing only viable organisms in this experiment. For 10-50µm organism, the correlation between the Tetraselmis sp. concentration and the ATP results was relatively good (R2>0.77 or 0.98 when excluding deviating results). However, the luminescence signal measured in the sterile seawater was in the same range as in samples with algal density below 200cell/mL. In the 10-50µm organism group, IMO requires a maximum concentration of 10 cell/ml. Solution for resuspension with low luminescence signal should be used to improve the detection limit of the instrument. The use of artificial seawater as solution for resuspension was not investigated in this experiment. In this test, the samples of organisms were not filtered to remove bacteria that followed with the algal culture. References OECD (1985). OECD Test Guideline for Testing of Chemicals 202; Daphnia sp. Acute immobolisation test and reproduction test. 10/11

11/11