Wind Direction Vane. Z345. Installation Guide.

Similar documents
Installation Guide. WSD-100 Wind Speed and Direction Sensor For XR5 Data Loggers. February, 2011

ATL Fuel Level Sender Probes

Givare NC-SRS 280 och 880

Micrio WS1 Replacement Wind Speed Sensor and WC1 Replacement Wind Compass Sensor for Raymarine ST50 and ST60 Wind Instruments. Rev 4.

Series 6000 Torque measured metal bellow coupling


Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

IMPORTANT DOCUMENTATION DO NOT DISCARD!

Series 7500 Torque Sensor

TRIMMING UNIT/DIAMOND MACHINE TST.13

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

Wind Direction Smart Sensor (S-WDA-M003)

Networkfleet 3500 Product Line Installation Guide

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Manual for GlobePharma Mini-Press II Rotary Tablet Press

Wiper Motor Marinco 2.5. Installation Instructions

Fitting Instruction: Daytona 675 Street Triple from VIN , Street Triple R from VIN A

Contents. Document information

PART 1 - INTRODUCTION...

OPL BASIC. Dosing System for Professional Laundry machines. Contents

QR12 (1.22 ) Diameter Optical Encoder

Sense it! Connect it! Bus it! Solve it! EncoderS

LED...A Q Series Sealed High-Intensity

POSITIVE DISPLACEMENT FLOWMETER - IM012P (PULSE)

Subminiature Load Cell Model 8417

CETAC Z-Drive Assembly

SEISMIC VELOCITY TRANSDUCER T1-40

Cable Plug acc. to DIN EN , Form A

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

MODEL T10023 ACCESSORY KIT #1 FOR T10010/T10097 WET GRINDER

Electronic Pressure Switch EDS 300

WIRELESS REMOTE ASSEMBLY, 24VDC, 1 TRANS,1 REC

INSTALLATION AND OPERATION MANUAL

Proportional pressure regulators VPPE

12-Volt Negative Ground Installation Instructions

Duct Humidity Transmitter

Original Assembly Guide

Telefon (+45) Telefax (+45) Installation and operating manual

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

Toroidal Conductivity Sensor

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

PROXIMITY CARD READERS C-10, C-20, C60, C70

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

DIAMOND Gear Company, LTD. an ERIKS Company. Installation, Maintenance, & Operation Manual Declutchable Worm Gear

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

Displacement encoders

GREISINGER electronic GmbH

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Depending on which elastic support you have you can secure the V2 power unit to the following seat bracket tubes: EXTERNAL DIAMETER 27.

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

GAERTNER SCIENTIFIC CORPORATION 3650 Jarvis Ave. Skokie, Illinois U.S.A. tel: fax: @gaertnerscientific.

Electrically Released Brake ER-825, ER-1225 with Pin Drive Armatues for Montgomery Kone

SECURITY CAMERA INSTRUCTION MANUAL ENGLISH VERSION 1.0 LBC

3. Loosen 3 x grub screws in the Dec end cap and unscrew the cap and counterweight shaft. NEQ6 Belt Modification Kit.

2006 HEADSHOK Service Video #1

The Do s and Don ts of Pressure Transducers

DPE Parallel Gripper- Electric Gripper Series

Mounting Instructions. Torque Transducer. A en

WIND ALARM. Wind Speed Alarm. Wind Speed. Set Point 2. Set Point 1 NEW BEDFORD, MA USA

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

HG600/HG800. Hydro-Power Unit. Installation and Operation Guide

INSTALLATION MANUAL «SD» RANGE

AZEK Rail Install Guide

Connecting the Channel A

Combustible Gas Transmitter RK-05

MINI MCR-SL-R-UI(-SP)

The Fan-Aspirated ISS includes these components: Metric Rain Adapter. The hardware shown here is provided for assembly and mounting:

Determine the desired location fixture and center the coaxial cord location to the electrical box.

5800 Temperature Sensor Cable Assembly

Servo Info and Centering

Machine needle shut-off nozzle type HP

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: No.: SE-...

Triac Printed Circuit Board Replacement

Assembly and Usage Instructions

Electric Meat Grinder

EZ-48-3AB Weather Station Mounting Tripod and Mast

Mounting Tripod Kit Installation Manual

Dissolved Oxygen Sensors

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

BLUE RIBBON CORP. BC001 Birdcage Installation Manual

Remote Head REMO ONE. Code Manual

Water Leak Detection System

Service Manual Rol-Lift

Step 1. Item 6. Item 1

PREASSEMBLED ELEMENTS FOR LIFTING AND SLIDING DOORS

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

INSTRUCTION MANUAL HYDRAULIC GATE TRANSMISSION SYSTEM ECO240-ECO360

Three Channel Optical Incremental Encoder Modules Technical Data

Threaded Resistance Thermometers Model TR10-D, Miniature Design

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Typical Aluminum GFM Mass Flow Meter

Be careful not to scratch or hit front edge of the side viewing micro prisms onto hard objects!

RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G

Transcription:

Wind Direction Vane. Z345 Installation Guide.

Wind Direction Vane Installation Guide Index. Description. 3 Features. 3 Ordering Information. 3 Specifications. 3 Product Liability. 3 Connection & Wiring. 4 Wiring. 4 Wind Vane Dimensions. 4 Mounting Plate Dimensions. 4 Theory or Operation. 5 Site Selection. 5 Mounting. 5 Orientation. 5 Wind Vane Assembly Diagram. 6 Maintenance. 6 Alignment Calibration. 7 2

Wind Direction Vane. Description. The Wind Vane is a highly responsive current loop output wind vane. The vane body is made from stainless steel and anodised aluminium. Stainless steel shafts, bearings and fittings are used throughout. A precision potentiometer is coupled to the vane shaft to provide an analogue output proportional to the wind direction. A counterweight provides precision balancing of the tail assembly on the shaft. Features. Rugged Construction. Temperatures of -5 to 60 C. Various Output Types. High Accuracy. Easy Installation. 4~20mA. Voltage. Potentiometer. Z345 Ordering Information. WD-CL: WD-V: WD-P: Wind Vane with 4~20mA output. Wind Vane with 0~5V output. Wind Vane with Potentiometer output. Specifications. Common Specifications: Sensor Type Rotating vane. Range 10 ~350 (±10 dead band at North). Accuracy ±3% max (10 ~350 ). Linearity Error ±2% max (10 ~350 ). Cable 5m, UV Resistant. Rotation Life 10,000,000 cycles. Operating Temperature -5 ~60 C. Temperature Error ±350ppm/ C typical. EMC Compliances Emissions EN 55022-A. Immunity EN 50082-1. Safety Compliances EN 60950. Dimensions - Overall L=410, H=230mm. - Mounting Plate L=70mm, W=38mm, H=6.5mm, PCD=55mm. Current Output Specifications: Output 4~20mA, 2 wire (Loop Powered). Damping 2min Nominal over 90. Load Resistance 500Ω @ 24Vdc. Supply Voltage 12~24Vdc. Range 4mA = 0 (north), 8mA = 90 (east), 12mA = 180 (south), 16mA = 270 (west). Voltage Output Specifications: Output 0~5Vdc, 3 Wire (common ground). Damping 2min Nominal over 90. Power Supply Required 12Vdc. Potentiometer Output Specifications: Transducer Wiper Output Potentiometer 10,000Ω. 1MΩ in series. Product Liability. This information describes our products. It does not constitute guaranteed properties and is not intended to affirm the suitability of a product for a particular application. Due to on-going research and development, designs, specifications, and documentation are subject to change without notification. Regrettably, omissions and exceptions cannot be completely ruled out. No liability will be accepted for errors, omissions or amendments to this specification. Technical data are always specified by their average values and are based on Standard Calibration Units at 25C, unless otherwise specified. Each product is subject to the Conditions of Sale. Warning: These products are not designed for use in, and should not be used for patient connected applications. In any critical installation an independent fail-safe back-up system must always be implemented. 3

Connections & Wiring. All wind vane s come fitted with a 5 metre UV resistant cable. WD-CL 4~20mA Output (Loop Powered). Red + + - 24Vdc Power Supply. Black - + - Field Station / Indicator etc. WD-V Voltage Output. Yellow + (12Vdc) + - 12Vdc Power Supply. Blue + (0~5V) Green - (COM) + - Field Station / Indicator etc. WD-P Potentiometer Output. Yellow 10KΩ Potentiometer Blue - Wiper Output (includes 1MΩ in series). Green Wiring. All cables should be good quality overall screened INSTRUMENTATION CABLE with the screen earthed at one end only. Signal cables should be laid a minimum distance of 300mm from any power cables. It is recommended that you use power supplies with ungrounded outputs and that you do not ground current loops. Lightning arrestors should be used when there is a danger from this source. 4

Wind Vane Dimensions. Mounting Plate Dimensions. 55mm 38mm 6.5mm 70mm Theory of Operation. Wind direction is defined as the direction of the source of the wind flow measured in degrees from true north in a clockwise increasing angle. A potentiometer is mounted directly to the Vane shaft and rotates with the shaft. Changes in wind direction are sensed by a balanced vane assembly and this rotation moves the potentiometer. When a voltage (Vin) is connected across the potentiometer, the output from the wiper of the potentiometer is a voltage form 0 to Vin as a direct function of wind direction. This is converted to an analogue signal by the internal electronics. Site Selection. Location of the sensor is critical for accurate wind measurements. The standard exposure of an vane or anemometer on open, level terrain is 10 metres above the ground. Open, level terrain is defined as level ground with no obstruction within 300 metres. In Locations where obstructions are not large, such as residential areas, and are distributed more or less evenly, the sensors may be placed at an effective height of h+10 meters, where h is the approximated height (in metres) of the various obstacles. As an example, in a location where trees and buildings reach to about 5 metres, the sensor should be placed on a 15 metre mast to avoid erroneous results. In areas where large obstructions do exist within 300 metres of the sensor, the vane can be mounted raised from the top of a building, however the building itself disturbs the wind flow and must be taken into account before installation. Mounting. The Vane can be mounted using the two holes in the bottom mounting plates. This allows mounting on any flat LEVEL surface. The Vane can also be used in conjunction with a Anemometer on a single cross-arm to form a wind speed and direction measurement set. View from top. North Orientation. If the wind vane is supplied assembled, it will normally be set up to be mounted with the screw holes north south facing and the wire coming out the east side of the mounting plate. After mounting always check the orientation of the vane and realign if necessary. Wire 5

Wind Vane Assembly Diagram. Maintenance. The Vane shaft coupled to the potentiometer should turn freely at all times. Rough motion indicates worn bearings either in the potentiometer or in the top bearing. If the unit is rough or tight, both the potentiometer and top bearing should be replaced. The bearings can be replaced in the field or the unit returned to the factory. Since corrosion can be a problem, using a non corrosive lubricant such as bees wax on all external parts and all screws and fasteners will make disassembly easier. If the bearings are to be replaced in the field, you will need the Vane Service Kit that includes one bearing and a shaft with the potentiometer and electronics attached. Follow the steps below to replace the bearings: Remove the cap by unscrewing. Loosen the Allen screw in the Wind Vane head and remove Wind Vane head. Unscrew case from base, being careful of the wires. Unplug the cable from the electronics. Using the old shaft, carefully knock the upper bearing out. Clean all parts if required but do not clean the new bearings. Insert new shaft with potentiometer and electronics from the bottom and press hard to push potentiometer into the O ring. Plug wire into the new electronics. Screw case onto the base. Slide the Wind Vane head onto the shaft. Realign Wind Vane head as described in Alignment section. Replace the cap by screwing it onto the shaft until finger tight. Tighten the Allen set screw in the Wind Vane head. Spin the Wind Vane head by hand to assure smooth operation. The Wind Vane head should coast to a smooth stop. Use great care in assembly of the sensor. Never use excessive force to make parts fit together. Over-tightening of fasteners will either break the fastener or damage the machined threads of the sensor. 6

Alignment Calibration. The potentiometer is aligned with north by rotating the case while monitoring the output. Remove the cap from the shaft. Loosen the Allen screw in the Wind Vane head. Rotate the Wind Vane head until it points south. Hold the Wind Vane head pointing south while rotating the shaft until the signal output reads 12 milliamps or the connected equipment indicates south. Tighten the Allen screw in the Wind Vane head. Replace the cap. 7

www.intech.co.nz Christchurch Ph: +64 3 343 0646 Auckland Ph: 09 827 1930 Email: sales@intech.co.nz 8 WD-XX 030215