ATEX instruction for PAHT G 2-90 in dust applications

Similar documents
ATEX instruction APP pumps

Explosion proof enclosures

Oil and Coolant Circulating Heating System. Model - OCSM

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Series TMM Axial Piston Motor. Technical Information

SEISMIC VELOCITY TRANSDUCER T1-40

Installation Guide. DEVIreg 530. Electronic Thermostat.

Hydraulic control unit series

Terminal Boxes Series 8146

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

CRN A-F-G-E-HQQE 3x400D 50 HZ

Technical data sheet TDS0070

Technical Data. Dimensions

Compact pressure switch Flameproof enclosure Ex d Model PCA

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Threaded Resistance Thermometers Model TR10-D, Miniature Design

DEVIreg 330 (+5 to +45 C)

MT MOTORI ELETTRICI. Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

Fire Pump Plan Review March 2010

Technical Data. Dimensions

Energy Recovery Device isave 21-40

Installation Manual DIAPHRAGM WELL TANK

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

Inductive sensor NI10-M18-Y1X-H1141

300 Series PA Pump and Cooler Assemblies

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

Conlift1, Conlift2, Conlift2 ph+

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF)

Model 1210C Battery Powered Pump Shown. Description

Installation Manual DIAPHRAGM WELL TANK

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Hydraulic Control Solutions

Operating Instructions

Static Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity?

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

IMPORTANT SAFETY NOTICE

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

NITROUS TRANSFER PUMP INSTRUCTIONS

PBX Series Quick Fit Connector Bimetallic Steam Traps

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Explosion-Proof Electric Unit Heaters

Instruction manual of pumps WQ, WQF, SN, Furiatka, Furia, KRAKEN, BIG, IP, IPE, SWQ, CTR

Rexroth Hydraulic Pump A10VO Series User Manual

Toroidal Conductivity Sensor

Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

OLI. Oil level indicator

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

ZOP, ZOT SIGMA PUMPY HRANICE GEAR PUMPS

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Waste Oil Handling, Spill Containment & Lighting

Terminal Box. Specifications TNCN

Series 510 Submersible Level Transmitters

SunMaxx Solar Filling Station Operating Instructions

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Wanner International and ATEX Directive 94/9/EC Covers - Category 2 Zone 1 and Category 3 Zone 2 requirements

Please also see 10 golden rules for correct Saniflo installation on

Series Hose Reels

Mechanical shaft seal types and sealing systems

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Operating Instructions

A/C refrigerant system, overview

CEILING CASSETTE FAN COIL UNIT

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Hydraulic multidisc Brake H420

Installation Instructions It is recommended to check the following points when receiving this product:

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

3/2-way Solenoid Valve, direct-acting, NC or NO

Unit 24: Applications of Pneumatics and Hydraulics

Volkswagen B3 Passat General-Engine 4 CYL. 19 Engine - Cooling System (Page GR-19)

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

A10VSO Nominal size 18 see RD A10VSO Nominal size see RD 92711

INTRODUCTION WARNING S!!! VOC SHOULD BE BETWEEN MUST NOT EXCEED 96 VOC USE DC CIRCUIT BREAKER/ISOLATOR BETWEEN SOLAR PANELS & CONTROLLER

INSTRUCTION MANUAL IM042. Slide Rail Systems - Series A10 INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

Your safety and the safety of others are very important.

Components for System Solutions E9/5. Ex d Enclosure System Made of Light Metal or Stainless Steel, "Flameproof Enclosure" Series

SF15K SF05KSS, SF10KSS

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

ATEX Fans 08/02/2008. Data subject to change without prior notice

Operating Instructions Drill rig DRU160

Sprinkler Identification Number. Page 1 of 6 MARCH 2014 TFP288. Worldwide Contacts.

BLADDER SURGE CONTROL SYSTEM

Compressed Gas Cylinder Program

PET-10 INSTRUCTION MANUAL PRESSURE TANK

Technology for Vacuum Systems. Instructions for use

San josé OWNER S MANUAL

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Operation Instructions. KleeBlower Compressor/Vacuum pumps. Models: KB129 KB8415

Power Cube Open Source Ecology Page 1. Power Cube. Version 4

BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap

Transcription:

MAKING MODERN LIVING POSSIBLE Instruction ATEX instruction for PAHT G 2-90 in dust applications danfoss.high-pressurepumps.com

Table of Contents 1. Common demands for Category 2 and 3 installations...3 2. Design guide for Category 2 (zone 1) systems...5 2.1 Temperature sensor...5 2.2 Pressure sensor...6 2.3 Preferred system design and P&ID for Category 2 pump....6 3. Design guide for Category 3 (zone 2) systems....7 3.1 Pressure sensor...7 3.2 Preferred system design and P&ID for Category 3...7 4. EU Declaration of Conformity....9 The Danfoss pumps are marked for application in Group II Category 2 or Category 3 systems. II 2 DG c b T6 II 3 DG c T6 Nessie MADE IN DENMARK PUMP PAHT G 12.5 SERIAL NO. 42825902-253 CODE NO. 180B6184 II 2 DG c b T6 II 3 DG c b T6 Example ATEX pump label This document describes how to integrate a pump in a system depending on the Category demand. Equipment groups (Annex I of the EC-Directive 94/9/EC) Group I (mines, mine gas and dust) Group II (other explosive atmospheres gas/dust) Category M Category 1 Category 2 Category 3 1 2 G (gas) (Zone 0) D (dust) (Zone 20) For equipment providing a very high level of protection when endangered by an explosive atmosphere For equipment providing a high level of protection when likely to be endangered by an explosive atmosphere For equipment providing a very high level of protection when used in areas where an explosive atmosphere is very likely to occur G (gas) (Zone 1) D (dust) (Zone 21) For equipment providing a high level of protection when used in areas where an explosive atmosphere is likely to occur G (gas) (Zone 2) D (dust) (Zone 22) For equipment providing a normal level of protection when used in areas where an explosive atmosphere is less likely to occur 2 180R9313 / DKCFN.PI.012.B2.02 / 521B1305 / 06.2013

1. Common demands for Category 2 and 3 installations This instruction is a supplement to existing product instruction as ATEX components are subject to some limitations compared to standard components. The limitations are described in this ATEX instruction. Validity: Approvals are only related to water as fluid. If other fluids are used these must be non-flammable fluids. The pumps are designed to pump liquids and not gasses! It is the user s responsibility to ensure that the pump is fluid filled during start-up and operation. Fluids: If the pump is to operate on other fluids than water, please contact Danfoss. Other operation and maintenance conditions might apply. Minimum suction pressure: The user must always ensure that the pump is bleeded. The pumps must always be operated with a positive head on suction port. The allowable minimum and maximum inlet pressure for the suction port can be found in the pump data sheet. Maximum discharge pressure: It is the user s responsibility that the pump discharge pressure does not exceed the max continuous discharge pressure stated in the pump data sheet. Temperature: The pump is not to be operated in systems where the fluid temperature exceeds 50 C/122 F. Filtration: The fluids entering the pump must as a minimum always be filtered according to the specification found in the pump data sheet. External impacts due to: Gases: The pumps are made in materials resistant to most common gases. The user of the pump must ensure that materials used are resistant to the gases applied. In ATEX dust applications, the layer of dust may never exceed 5 mm [0.002 inch], we recommend to paint the components in contrasting colors, to make deposits more visible. Assembly of pump drive unit: Motor - Pump assembly and system integration: When assembling the pump with the bell housing, flexible couplings and motor, it is the builder s responsibility that the parts used conform to the ATEX directive and that the components are assembled and running according to the operational data/design found in product data sheets and instructions. In order to avoid dust accumulations, the system design must be with smooth surfaces and with as few dead spaces as possible. All parts must be potential equalized in a Category 2 and 3 system, according to local regulations. The wire gauge must be equal to the wire gauge applied in the supply of the electric motor and may as a minimum not be smaller than 16 mm 2 [0.63 inch 2 ] (EN 60079-0, item 15.4). Grounding connectors Grounding connectors, mark with Grounding connectors It is important to potential equalize each component directly to a base point. 180R9313 / DKCFN.PI.012.B2.02 / 521B1305 / 06.2013 3

Choice of bell housing and coupling The material for the bell housing can be steel, stainless steel or aluminium with a magnesium content below 7,5%. The bell housing must have an inspection and a drain hole. The drain hole must be placed at the lowest point to ensure the fluid can get out if there is a small leak from the pump shaft seal. In dust applications, the bell housing, which covers the rotating parts, must minimum be an IP5x, dust proof. Make sure that inspection and drain holes are dust proof and we recommend often inspecting for dust or fluid accumulations. The dust may not come in contact with rotating parts, as this can cause an increased temperature. The distance between bell housing and the rotating parts must be at least 5 mm [0.2 inch]. Coupling for use in hazardous areas are marked with regard to the respective permissible conditions of use. Aluminium as coupling material is generally excluded for explosive areas. See special conditions for safe use in coupling operation- and ATEX instruction from coupling supplier. Mounting of bell housing and coupling: 1. Mount the coupling on pump shaft. Ensure an air gap between end of coupling and pump flange of min. 4 mm [0.16 inch] D. 2. Mount the bell housing on pump. Secure bolts with the right torque - see pump instruction. 3. Measure the longest distance A from top of bell housing to the bottom of coupling claw. 4. Mount the coupling on motor shaft. Ensure the coupling and motor flange are not in contact with each other. 5. Measure from motor flange to the top of the coupling. That measurement B shall be 3-5 mm [0.12-0.2 inch] shorter than the measurement A. 6. Adjust respectively, verify the measurement, and secure both couplings with the right torques on the locking screws (see coupling operation & mounting instruction). 7. Mount the elastic spider and mount the bell housing/pump on the motor. After mounting it must be possible to move the elastic spider 3-5 mm [0.12-0.2 inch] axial C. The check can be done through the inspection hole of bell housing. Secure motor flange bolts with the right torque - see pump instruction. Caution! Read the pump & coupling Installation, Operation, Maintenance instructions before mounting. Electric motor Motor for use in hazardous areas are marked with regard to the respective permissible conditions of use. Marking: Category 2, Zone 1: Ex d, Ex de, Ex e Category 3, Zone 2: Ex na All rating plate values relating to certification must be carefully checked to ensure that the motor protection, atmosphere and zone are compatible. See special conditions for safe use in electric motor operation manual and ATEX instruction. Caution! Ensure with regular inspection the motor flange is not affected by severe corrosion. Motors in variable speed operation: Certain criteria must be considered to ensure that the combination of VFD and motor can be used safely. The requirements depend on the protection type in use. The motor must be dimensioned so that its surface temperature remains at a safe level with respect to the temperature class. In most cases 4 180R9313 / DKCFN.PI.012.B2.02 / 521B1305 / 06.2013

this requires either combined type tests or the use of direct temperature control. Caution! Consult motor manufacturers for right dimensioning. Cabling and electrical connections Suitable cable lugs must be used for the connection of all main cables. The cable connection must fulfil the requirement stated in the national standards for installation or in the standard EN 60204-1 and EN 60079-14. In addition, earthing or bonding connection facilities on the outside of electrical apparatus must provide effective connection of a conductor. Caution! Read the Installation, Operation, Maintenance manual of the chosen motor to ensure all applicable warranties. Failure modes due to operational conditions Following operational conditions can cause a pump failure: Pump running dry Too high inlet pressure Too low inlet pressure Too high temperature of the fluid being pumped Too high ambient temperature Pump is pumping against blocked port Pump operate with a non-specified/ approved fluid Pump running the wrong direction Non-return valve in front of the pump inlet Insufficient filtration Pump is not being serviced accordance to Danfoss specifications. Danfoss recommends building systems with a high inherent safety degree. The PI&D on the next pages shows how a high degree of safety can be reached when using a Danfoss pump. 2. Design guide for Category 2 (zone 1) systems 2.1 Temperature sensor Pump housing temperature increase causing problems due to pump breakdown/failure in a Category 2 rated system. In a Category 2 system, the pump housing temperature must be monitored. Pump housing temperature must always be lower than 85 C / 185 F. Surface temperature must never exceed 2/3 of minimum ignition temperature of the dust cloud, not even in the case of malfunctions. A sensor integrated on the pump must be used to monitor pump housing temperature. This sensor must be mounted on the pump as shown in the drawings. The system must stop the pump, if a temperature of 60 C / 140 F is exceeded. Electronic equipment/control of temperature and pressure measuring must comply with EN 954 (Category 3) or EN 13849-1 to fulfil IPL2. Caution: The sensors may not be exposed by direct cooling as it will affect the thermal readings. Therefore they shall be protected against direct wind. S1 PAHT G 20-90 PAHT G 20-90 Use the M6x10 (A) or M8x10 (B) thread to locate the temperature sensor. Ensure good thermal contact between the sensor and pump end cover and avoid corrosion (material choice of sensor, crevice corrosion). Temperature sensor WIKA TR50-O Explosion protected version with stainless steel contact block can be used (see S1 at picture). Mount the sensor with a M6 screw on the pump end cover. Ensure good thermal contact between the sensor and pump end cover and avoid crevice corrosion. 180R9313 / DKCFN.PI.012.B2.02 / 521B1305 / 06.2013 5

Temperature sensor WIKA TR50-Q Explosion protected version with worm drive hose clip made of stainless steel can be used on these pump types (see S2 at picture). Select the right diameter size of the worm drive hose clip. Find the diameter of pump housing in the pump data sheet. S2 Ensure good thermal contact between the sensor an pump housing and avoid crevice corrosion. 2.2 Pressure sensor Checking whether suction port is fluid filled and fluid flows unrestricted: To monitor if suction line is fluid filled at right pressure, a pressure switch/sensor must be placed in the pump suction port. This switch/ sensor must as a minimum be set to the minimum suction pressure specified in the pump data sheet. Pump must be stopped by system, if pressure declines below sensor pressure setting. PAHT G 2-12.5 2.3 Preferred system design and P&ID for Category 2 pump Pressure and temperature sensors are mounted due to a direct demand originating from ATEX risk evaluation. The pump is directly fed by a pressure line (feed pump). Fluid has to be filtrated down to 10µm absolute Pressure switch, Pump is stopped when pressure is below minimum suction pressure according to pump datasheet Category 2 certified electric motor, bell housing and flexible coupling. Pressure feed Temperature swicth set to max 50 C M Temperature sensor mounted on pump. P in P out Danfoss ATEX pumps R out Relief valve To fluid reservoir / drain 6 180R9313 / DKCFN.PI.012.B2.02 / 521B1305 / 06.2013

System where fluid is supplied from tank. Pump is placed outside the tank. Pump suction port is always below fluid level. P in Fluid has to be filtrated down to 10µm absolute Tank Minimum Water Level Switch Maximum Water Temperature Switch set to 50 C Pressure switch, Pump is stopped when pressure is below minimum suction pressure according to pump datasheet Category 2 certified electric motor, bell housing and flexible coupling. M Temperature sensor mounted on pump. P out Danfoss ATEX pumps Relief valve 3. Design guide for Category 3 (zone 2) systems 3.1 Pressure sensor Checking whether suction port is fluid filled and fluid flows unrestricted: To monitor if suction line is fluid filled at right pressure, a pressure switch/sensor must be placed in the pump suction port. This switch/ sensor must as a minimum be set to the minimum suction pressure specified in the pump data sheet. Pump must be stopped by system, if pressure declines below sensor pressure setting. 3.2 Preferred system design and P&ID for Category 3 Pressure sensor is mounted due to a direct demand originating from ATEX risk evaluation. The pump is directly fed by a pressure line (feed pump). Typical Category 3 systems Fluid has to be filtrated down to 10µm absolute Temperature swicth set to max 50 C Pressure switch, Pump is stopped when pressure is below minimum suction pressure according to pump datasheet Pressure feed M Category 3 certified electric motor, bell housing and flexible coupling. P in P out Danfoss ATEX pumps R out Relief valve To fluid reservoir / drain 180R9313 / DKCFN.PI.012.B2.02 / 521B1305 / 06.2013 7

System where fluid is supplied from tank. Pump is submerged into tank and suction port is always fluid covered. Filter Pressure Switch 10µm filter M Category 3 certified electric motor, bell housing and flexible coupling. R Relief valve Minimum Water Level Switch Maximum Water Temperature Switch set to 50 C P Tank Danfoss ATEX pumps System where fluid is supplied from tank. Pump is placed outside the tank. Pump suction port is always below fluid level. P in Fluid has to be filtrated down to 10µm absolute Tank Minimum Water Level Switch Maximum Water Temperature Switch set to 50 C Pressure switch, Pump is stopped when pressure is below minimum suction pressure according to pump datasheet Category 3 certified electric motor, bell housing and flexible coupling. M P out Danfoss ATEX pumps Relief valve 8 180R9313 / DKCFN.PI.012.B2.02 / 521B1305 / 06.2013

4. EU Declaration of Conformity 180R9313 / DKCFN.PI.012.B2.02 / 521B1305 / 06.2013 9

Danfoss A/S High Pressure Pumps DK-6430 Nordborg Denmark Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. 10 180R9313 / DKCFN.PI.012.B2.02 / 521B1305 / 06.2013