e OLI Oil level indicator

Similar documents
OLI. Oil level indicator

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34

INSTRUCTION MANUAL Oil level indicator with pointer

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

RY2 miniature industrial relays

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

HERZ-Thermal Actuators

Voltage Regulator SPAU 341 C. Product Guide

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Electro-hydraulic pressure switches type DG

Plastic tube flowmeters Series PT/PS

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron.

Instruction Manual Differential Pressure Transmitter

ATL Fuel Level Sender Probes

AMPSEAL* Automotive Plug Connector and Header Assembly

NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Electromagnetic Flow Meter

3/2-way Solenoid Valve, direct-acting, NC or NO

HCR3.2/.. Chipcard reader HOTEL SOLUTION

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Pluggable interface relays CR-P Pcb relays

IFC 070 Technical Datasheet

Compact pressure switch Flameproof enclosure Ex d Model PCA

Vacuum drying oven for non-flammable solvents

FLOAT SWITCHES FLOW SWITCHES FOR LIQUIDS PRESSURE SWITCHES

HARTING Ethernet Cabling 4-poles Overview

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

nano led THE GREEN LIGHT

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

DMS 680. Universal length measuring system gauge inspection for»iso 9000«requirements

Cable Plug acc. to DIN EN , Form A

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Mureva Assembly surface mounted wiring devices

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Hydraulic Control Solutions

Rotary actuators Rotary wing drives Series RAK. Brochure

4 Posiflow Proportional Solenoid Valves

Elektromotoren und Gerätebau Barleben GmbH

Electric Rotary Actuator - On/Off or programmable control actuator

Cross-beam scanning system to detect slim objects. 100 mm in

ACS-30-EU-EMDR-10-MOD

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

ACCESS CONTROL SECURITY SYSTEMS TRANSMITTERS SHOW-WINDOWS PROTECTION COMPONENTS FOR GATES AUTOMATION

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

3DLevelScanner II TECHNICAL DATA SHEET

Scraper Passage Indicator. Electrical Indicator. Features

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Force measurement. Forces VECTORIAL ISSUES ACTION ET RÉACTION ISOSTATISM

Messko. Messko. MTraB - Maintenance Free Dehydrating Breather Ordering specifications XX - XX - XXX - XX

Temperature & Humidity SMS Alert Controller

How To Read A Pipe From A Sensor

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids

How To Use A Flowmeter

Compact cylinder Double acting single rod type. SSD SSD-L (with switch) Double acting Compressed air to 60 (no freezing) Rc1/8 Rc1/4 Rc3/8

Transformer oil cooler ALFA A02

Security. Alarm central unit. Ref.-No. KNX Alarm central unit EAM 4000

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

Technical Information

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Thermometer in stainless steel with capillary and switch contacts

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

Proportional pressure regulators VPPE

AIR-AIR PRESSURE MULTIPLIER (BOOSTER)

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Transmission Silicone Insulators Line Post 69 kv to 161 kv

SMS 4 / SMS 5 safety mat Product information

Mini USB and USB 2.0-IP67 Connector System

14 PHOENIX CONTACT Courtesy of Power/mation Energy Lane, Saint Paul, MN

In addition to the basic models, it is also possible for the units to be outfitted with add-ons.

Machine Safety Switch: SI-LM40 Series Limit Switch Style

Plastic Flow Meters for gases & liquids, using TROGAMID* & POLYSULFONE Technology

Industrial circular connectors

Color Mark Sensor with Red or Green LED E3S-VS

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Technical Information RIA14

USER S GUIDE. EE210 - Humidity and Temperature Transmitter for demanding Climate Control Applications GENERAL CAUTION CONNECTION DIAGRAM

Output torques up to 8000 Nm. General features. Protection. External coating. Working temperature range

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

1ZSE en, Rev. 8. Transformer bushings, type GOE and GOE(2) Technical guide

DBS720 / FDS221-R / FDS221-W Sounder base, Alarm sounders

IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

James M. Pleasants Company

Transcription:

eoli Oil level indicator

Oil level indicator eoli Unexpected or accidental oil leakages may occur randomly along transformer s lifetime. Clear indication of oil level inside transformer tank and on load tap changer is provided by means of a pointer on the main dial which ensures high visibility from any viewpoint. eoli Effective maintenance and enhanced reliability through continuous oil level monitoring The float movement associated with the oil level is transmitted to the dial trough a magnetic coupling system. The float is available with either axial or radial movement. The standard dial show the reference marks corresponding to the levels that the oil shows should reach at the following temperatures : -20 C, +20 C, +85 C. Data monitoring is provided by means of: - analog output 4-20mA - modbus RTU communication protocol Viewer In order to have an additional reading at a men height a dedicated dial is highly recommended to be fitted on the transformer s wall. The info displayed on the viewer are transmitted via 4-20mA by the dial on the oil tank. 2

Advantages 1. Continuous oil level monitoring - viewer is recommended for a better reading at men height 2. Customizable mounting flange suitable for all transformers designs 3. Magnetic couplings ensures a reliable movement transmission between float arm and pointer avoiding leakages through conservator wall 4. Adjustable value settings for switches (numbers or wording) 5. No printings neither stickers on the view glass: temperature indication is directly marked on the plate behind the view glass 6. Easy accessibility to wiring box 7. Float movement on radial and axial direction, available also for conservator equipped with rubber bag 8 Data dowload. Float movement This may be in the radial direction of the conservator (type LA ) or in the axial direction (type LB ), as shown in the drawing. LB model is also available with rolling floats for applications on conservators equipped with rubber bag. Float rod This is completely threaded. If the length is not specified (distance R in the drawing), the standard size indicated on the table is supplied. The rolling float arm is an aluminum tube. Indicating intervention The switching point of electric microswitches is setted with max 5 in advance with respect to the indications of the minimum or maximum. When there is a double contact on MIN and/or MAX, the second contact intervenes about 5 after the first contact. Indications for assembly The level gauges which have float movement in the radial direction of the container (type LA ) must be fitted offset with respect to the horizontal axis of the conservator (distance S ) so as to have an exact indication of the minimum and maximum oil level. Those with movement in the axial direction (type LB ) must be fitted in the centre of the conservator. The measurements of the movements (distance S ) and the length of the rod (distance R ) are obtained from the formulae given in the order sheet. It is good practice to check operation of the gauge after having fitted it on the conservator. For further and more detailed information, see the technical information card supplied. Tests and inspections The level gauges are subjected to insulation test towards earth as follows between circuit and earth, the minimum dielectric withstand strenght is 2kV in accordance to EN - 50216/1. The bodies of the level gauges, after having passed the dimensional inspection and without their internal parts, are tested for watertightness so as to eliminate those that have leaks. Final testing is carried out when the level gauge is completely assembled. The sensitivity of all the signaling movements and the accuracy of their assembly are scrupulously checked. 3

Oil level indicator Technical data Type eoli -22 eoli Design COMEM Interchangeable with existing solution, compatible with all trafo design Housing Die-casted Aluminum alloy RAL White 9002 View glass Polycarbonate or Tempered Glass Flange Surface treated die-casted aluminum alloy Dial - Numbers and letters directly screen-printed on aluminum plate - Customizable range (MIN +20 C MAX, other available) - Orange pointer Float Element Expanded ebonite Oil temperature -40 C, +120 C Environment temperature -40 C, +80 C Cable Gland 3; M25x1.5 Degree of protection IP65 IP66 upon request Power Supply 24V DC Analog Output 4-20 ma Modbus RTU RS485 Data Logger Dial at human eye level (viewer) Upon request Power supply 24V DC Identification codes 1 (letter) L Level gauge 2 (letter) A Movement of the radial float B Movement of the axial float V Viewer (remote indicator) 3 (number) 40 L140 C4 salinity environment resistance 50 L140 C5 salinity environment resistance 44 OLI C4 salinity environment resistance 54 OLI C5 salinity environment resistance 45 OLI-22 C4 salinity environment resistance 55 OLI-22 C5 salinity environment resistance 46 eoli C4 salinity environment resistance 56 eoli C5 salinity environment resistance 47 eoli-22 C4 salinity environment resistance 57 eoli-22 C5 salinity environment resistance 4 (letter) K Wiring diagram with 1 changeover switch on min. Y Wiring diagram with 2 changeover switch on min. X Wiring diagram with 1 changeover switch on min. + 1 changeover switch on max. W Wiring diagram with 2 changeover switches on min. + 2 changeover switches on max. O No contacts 4

Overall dimension Oil Level Indicator eoli / eoli-22 This device must be coupled with the flanges shown below Fig. 1 5

Overall dimension Viewer Fig. 2 6

Flanges Type LA eoli : 4 holes flange eoli-22 : 8 holes flange Fig. 3 7

Overall dimension Flanges Type LB eoli : 4 holes flange eoli-22 : 8 holes flange Fig. 4 8

R and s quote LA ØDC R = ( 2 20) ØDC S = ( 2 40) LB S = [ØDC 79.2] x 0.5 ( 0.86 ) + 29 ØDC = Conservator tank diameter Fig. 5 9

Wiring diagrams Diagram type K - CHANGEOVER SWITCH ON MIN (terminals 12-11-14) NC contact: terminals 12-11; NO contact: terminals 11-14 Diagram type Y - CHANGEOVER SWITCH ON MIN (terminals 12-11-14) NC contact: terminals 12-11; NO contact: terminals 11-14 - CHANGEOVER SWITCH ON MIN (terminals 22-21-24) NC contact: terminals 22-21; NO contact: terminals 21-24 Diagram type X - CHANGEOVER SWITCH ON MIN (terminals 12-11-14) NC contact: terminals 12-11; NO contact: terminals 11-14 - CHANGEOVER SWITCH ON MAX (terminals 32-31-34) NC contact: terminals 32-31; NO contact: terminals 31-34 Diagram type W - CHANGEOVER SWITCH ON MIN (terminals 12-11-14) NC contact: terminals 12-11; NO contact: terminals 11-14 - CHANGEOVER SWITCH ON MIN (terminals 22-21-24) NC contact: terminals 22-21; NO contact: terminals 21-24 - CHANGEOVER SWITCH ON MAX (terminals 32-31-34) NC contact: terminals 32-31; NO contact: terminals 31-34 - CHANGEOVER SWITCH ON MAX (terminals 42-41-44) NC contact: terminals 42-41; NO contact: terminals 41-44 Electrical characteristics Breaking and making capacity Voltage Uninterrupted current Interrupted current (making capacity) (breaking capacity) 24V DC to 220V DC 2A 10mA L/R < 40 230V AC 2A 2A cosφ > 0.5 Other values may be agreed between purchaser and supplier. The minimum contact life shall be 1.000 operations. Only in case that the devise has to operate in a system at 24V DC and making capacity up to 0.5VA, the switches shall be able to make a low current down to 10mA even after one year of non-operation. 10

Order sheet Number of pieces Oil level indicator movement Radial float Axial float eoli with 4 holes flange eoli with customized holes flange Type Dial 220 mm eoli 22 with 8 holes flange K Y Wiring diagram X W Moderate salinity areas acc. to ISO 12944 Environmental protection: Off-shore areas acc. to ISO 12944 Lens type Tempered glass Polycarbonate Viton Gaskets type NBR -40 C Mineral oils and low temperature Cable gland M25x1,5 Other Oil level indicator movement Standard (-20 C +20 C + 85 C) Special (Please fill up the special order sheet) Analog output 4-20mA Modbus RTU RS485 Data logger * Further technical data might be required by our sales specialist in case of order. 11

Strada Regionale 11, Signolo 22 36054 Montebello Vicentino (VI) - ITALY Tel. +39 0444 449311 Fax +39 0444 449352-440359 E-mail: comem@comem.com www.comem.com Due to technical product updates, the information contained in this catalogue may be subject to change without notice. Copyright 2015 COMEM. All rights reserved. Ed. 03/2015