A flat plate heat exchanger is used when the system requires isolating:

Similar documents
FILLING AND PURGING THE SYSTEM

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

presents Hydraulic Separation Beyond Primary / Secondary Piping

Modulex. Gas Fired Boiler Systems PIPING GUIDE GF-115-P. Modular, Condensing, Hot Water Boilers Models: 303, 454, 606, 757, 909, Instruction No.

SECTION Hot Water Heaters (Hot Water Recirculation Systems and Point-of-Use Water Heaters)

Commercial Gas Water Heaters

FLASH TANK ECONOMIZER PRODUCT GUIDE

Mini-HYDRO TM Installation Manual

Oil and Coolant Circulating Heating System. Model - OCSM

Advanced Heating & Hot Water Systems. Ultra High Efficiency Energy Star Listed Condensing Boiler

Nordic Heat Pump Product Guide

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

PLBG/GAS SAFETY Information Bulletin

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00

Condensing Boiler Efficiency

Commercial Gas Water Heaters

HS-901(A) BASIC STEAM HEATING SYSTEMS

CHAPTER 10 BOILERS, WATER HEATERS AND PRESSURE VESSELS

C. starting positive displacement pumps with the discharge valve closed.

HYDRONIC DESIGNER / INSTALLER MODULE DESCRIPTIONS

AMERICAN SOLAR WATER HEATING SYSTEM The Best Water Heating Solution Under The Sun

Ergo-Pro Single Line Solar Station Installation and Operating Instructions

I N S T A L L A T I O N I N S T R U C T I O N S F O R T H E H i l k o i l Energy S aving Hot Water Kit

NAVIEN AMERICA INC FITCH AVENUE

MUELLER FALLING FILM CHILLERS

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

MAC-120HE-01 Air-Cooled Chiller

Installation Manual DIAPHRAGM WELL TANK

Link-Up. Solid Fuel Association Guide to Central Heating.

What you can expect from your Solar Hot Water System

Installation & Operation Manual Models: STU

In-Line Air Separators

What is Thermal Expansion?

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Ceiling Mount Air Handler Manual

Commercial Semi-Instantaneous Water Heaters

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Commercial Gas Water Heaters

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)

Solar Skies Stainless Tank Series Water Heater

TANKLESS DURABILITY Tankless Product Guide

Series GM. Peerless Boilers. Residential/Commercial Gas Boilers

I N S T ALLATION INSTRUCTIONS & HOME OWNERS MANUAL IMPORTANT SAFETY INFORMATION

Your safety and the safety of others are very important.

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

Commercial Boiler Systems and Controls

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL EEMAX ELECTRIC TANKLESS WATER HEATERS IMPORTANT SAFETY INFORMATION

TD10. Selecting Circulators. Technical Documents. Taco Radiant Made Easy Application Guide STEP 1: ESTABLISH THE TARGET FLOW RATE FOR THE SYSTEM

GOLD Plus 30/40/60/80

2010 Residential Water Heater Replacement Check List

(a) Purpose. The purpose is to safeguard potable water supplies by preventing backflow into public water systems.

STATE SUPER HIGH EFFICIENCY Up To 96% Thermal RESIDENTIAL PREMIER POWER-VENT MODELS

RECON WATER HEATER INSTALLATION FORM

COMMISSIONING OF HVAC SYSTEMS

Boiler & Pressure Vessel Inspection discrepancies and failures

Element D Services Plumbing

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

SOLI TANKLESS PRODUCT GUIDE

PRESSURE REDUCING CONTROL VALVE

Therm-Omega-Tech, Inc. Therm-Omega-Tech, Inc. MODEL EMV. A Heavy Duty, Reliable Source For Tepid Water Delivery. Model EMV

ASME Packaged Indirect Fired Water Heater

DESIGNER S GUIDE EFFICIENCY+ BOILER

BULLETIN NO. TEH-908. Bell & Gossett R T. Hydronic System Design with the Bell & Gossett System Syzer / ON GPM FLOW

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

300 Series PA Pump and Cooler Assemblies

Installing, Operating & Maintaining MUNCHKIN HIGH EFFICIENCY HEATER with the 925 Controller

Boiler Manual. Installation Startup Maintenance Parts WARNING

Model 1210C Battery Powered Pump Shown. Description

INSTALLATION, OPERATING AND SERVICE INSTRUCTIONS

Preventing Overheated Boiler Incidents

Electric Flow Boiler

Steam Coil Installation, Operation and Maintenance

DRAFT HOOD OUTLET GS6-30-YORT NG Select - Tall - C3 Technology 28 FIRST HOUR RATING BTU INPUT PER HOUR

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

WMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler

THERM Tankless Water Heaters. Applications Manual

CERT. TO ASSE STD 1016 AND AND AND 1017 WT. LBS.

Air Conditioner Water Heater Model ACWH18

Boiler Applications Drawings

Installation Manual DIAPHRAGM WELL TANK

Session 2: Hot Water Supply

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Installation and Operating Instruction Manual

SOLAR HEATING SYSTEMS.

Electric Mini Tank Water Heaters WM-2.5 & WM-4.0

Design Consultant (Electrical Services) Design Deliverables and Responsibilities Allocation (Stage E+)

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

Steam System Best Practices Condensate System Piping

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Installing, Operating & Maintaining MUNCHKIN HIGH EFFICIENCY 399M COMMERCIAL BOILER

Versatility ::::::::::::::::::::::::::::::::::::::: the best. mod/con Performance. and UP TO.

LINDGREN-PITMAN, INC. Super Spool III Installation Instructions

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

Transcription:

Technical Bulletin #4 PLUMBING CONFIGURATIONS The Frontier Series provides a steady flow of high-temperature heat transfer fluid to various devices in your hydronic heating system, including hot water tanks and heaters, baseboard or free-standing radiators, radiant panels, in-floor radiant heat loops, and many other devices. You can install the Frontier Series as your primary or supplemental source of heat to an existing or new hydronic or forced-air central heating system. The Frontier Series is designed and pre-configured for easy installation in combination with the Frontier CX Hydronic Conditioning Manifold and the Thermsafe Overheat Protection Kit. This hydronic equipment, engineered specifically for the Frontier Series, eliminates much of the time and expense typically required to install a boiler while ensuring optimum heat transfer, flow rates, temperatures, and safety. (See piping diagrams below). Frontier CX Hydronic Installation System Components Frontier CX The Frontier Series CX is certified to operate as an atmospheric system. While having the highest quality welds, the heat exchanger is not an ASME certified pressure vessel. 3 2 1 Atmospheric Expansion Tank (Dealer provided) ThermSafe TM Overheat Cooling System (Dealer installed kit) Frontier CX Hydronic Conditioning Manifold (Factory pre-installed) Out > < In Steps to connect the hydronic system: 1. Connect the distribution loop to the supply and return ports of the factory installed Hydronic Conditioning Manifold (See piping and wiring diagrams below) 2. Connect Expansion Tank and the ThermSafe TM Overheat Cooling System. The ThermSafe kit makes this easy. (See piping and wiring diagrams below) 3. Fill the boiler and lines, add boiler treatment and freeze protection, and purge the system of air. 4. Ensure sufficient demand is available in the distribution loop and buffers to absorb 100,000 Btu (29.3kw)/hr with a full load and 60,000 Btu (17.58kw)/hr with a partial load. Integrate the Frontier CX On-Demand-Zone relay functionality where needed. Your Frontier Series hydronic system is now ready to operate. NOTE: The Frontier Series operates independently or as an add-on to an existing central furnace or boiler. If used as an add-on, the home system must be in good operating condition; meet all local building codes, ordinances, and safety standards; and be installed with required controls and in accordance with appropriate standards of the National Fire Protection Association. Greenwood Clean Energy, Inc 1 of 5

Hydronic System Configuration The Frontier Series Hydronic Conditioning Manifold (Part No. 100100) ensures a consistent flow rate through the internal heat exchanger and protects the boiler from condensation caused by low return temperatures. The Hydronic Conditioning Manifold may be piped with the installer provided atmospheric expansion tank connected on either the right or left side of the manifold (as shown in Schematic FP3A and FP3B). The tank does double duty as both expansion tank and reservoir for the ThermSafe Overheat Cooling System (Part No. 100110). NOTE: All plumbing schematics shown in this section are for illustration purposes only. Actual systems may require control and safety devices not shown in these illustrations. Consult your Greenwood certified home heating and plumbing professional for home heating system design and installation. Flat Plate Heat Exchangers Q: When should I use a Flat Plate Heat Exchanger? A: Flat plate heat exchangers are used to transfer heat between one circulation system and another. A mixture of propylene glycol and water flows through the manifold on the furnace side of the flat plate heat exchanger. This fluid does not mix with the fluid flowing through the distribution side of the heat exchanger. A flat plate heat exchanger is used when the system requires isolating: 1. Pressure differences. 2. Fluid differences. Greenwood Clean Energy, Inc 2 of 5

Pi ping Schematics (3) Atmospheric Expansion Tank must be positioned higher than any other point in the atmospheric piping loop. Tank size: 5 gal minimum fluid; 10 gal minimum tank volume. Vent Pipe (min. 1" diameter) (2) ThermSafe Overheat Cooling Assembly with Air Vent and Taco Zone Sentry, 2 way, Normally Open. Drawing shows system piping concept only. Installer is responsible for system design and compliance with local codes. NOTES: 1. The Hydronic Conditioning Manifold maintains a constant flow rate hydraulically separate from the distribution system. Distribution system piping should carry a flow rate of 10 to 30 GPM through the supply and return ports of the Frontier CX boiler loop. 2. The boiler loop must be piped to not develop excessive pressure in any portion of the boiler system. The Hydronic Conditioning Manifold s pressure relief valve opens at 30PSI. 3. The overheat cooling system piping is positioned above the boiler and designed to promote natural thermal circulation of the water in the event of a power failure. Greenwood Frontier Series Atmospheric System: Expansion Tank Piped Right FP 3A FPC03A-120919ANDD Water level should be maintained 1" above the top of the Overheat Cooling assembly inlet. The base of the Tank must be at least 4 inches above the top of the Frontier CX to provide sufficient NPSH (net positive suction head) to prevent cavitation of the circulator. (1) Frontier CX Hydronic Conditioning Manifold May be piped direct or through a flat plate heat exchanger. Circulator Ball Valve Elbow must be at the high point of the vertical rise. Horizontal distance between the elbow and the expansion tank should be less than 6 feet. Available as an Overheat Cooling Kit to be installed by the installer Fluid Level Sight Glass Factory preinstalled Isometric View H Supply Port Return Port C Vent Pipe Outlet (must be unthreaded) Boiler Drain for filling and draining the system. (4) Distribution System Greenwood Clean Energy, Inc 3 of 5

(2) ThermSafe Overheat Cooling System Assembly with Air Vent and Taco Zone Sentry, 2 way, Normally Open. Elbow must be at the high point of the vertical rise. Horizontal distance between the elbow and the expansion tank should be less than 6 feet. Available as an Overheat Cooling Kit to be installed by the installer Fluid Level Sight Glass Vent Pipe (min. 1" diameter) (3) Atmospheric Expansion Tank must be positioned higher than any other point in the atmospheric piping loop. Tank size: 5 gal minimum fluid; 10 gal minimum tank volume. Water level should be maintained 1" above the top of the Overheat Cooling assembly inlet. The base of the Tank must be at least 4 inches above the top of the Frontier CX to provide sufficient NPSH (net positive suction head) to prevent cavitation of the circulator. (4) Distribution System May be piped direct or through a flat plate heat exchanger. Circulator Ball Valve H C (1) Frontier CX Hydronic Conditioning Manifold Supply Port Return Port Factory preinstalled Boiler Drain for filling and draining the system. Vent Pipe Outlet (must be unthreaded) Isometric View Greenwood Frontier Series Atmospheric System: Expansion Tank Piped Left Drawing shows system piping concept only. Installer is responsible for system design and compliance with local codes. NOTES: 1. The Hydronic Conditioning Manifold maintains a constant flow rate hydraulically separate from the distribution system. Distribution system piping should carry a flow rate of 10 to 30 GPM through the supply and return ports of the Frontier CX boiler loop. 2. The boiler loop must be piped to not develop excessive pressure in any portion of the boiler system. The Hydronic Conditioning Manifold s pressure relief valve opens at 30PSI. 3. The overheat cooling system piping is positioned above the boiler and designed to promote natural thermal circulation of the water in the event of a power failure. FP 3B FPC03B-120919ANDD Greenwood Clean Energy, Inc 4 of 5

Nonstandard Installs Q: If the Frontier CX is installed without the factory mounted Hydronic Conditioning Manifold and Overheat Cooling Kit what piping and components are required? The Frontier CX Hydronic Conditioning Manifold and ThermSafe TM Overheat Cooling Kit simplifies the installation by including many of the components that typically must be installed in the boiler loop. The Hydronic components are custom designed for the Frontier Series, factory calibrated and preset to ensure optimum performance. For the rare situation in which the Frontier CX is installed without the install package (this will void the warranty without prior approval in writing from Greenwood Clean Energy), the installer must design, source, and install components to meet the following requirements: Hydronic System Functionality Frontier CX with install package Without install package Requirements Frontier Series Boiler Control System Outlet temperature monitoring Inlet temperature monitoring Flow switch cabling ThermSafe TM Overheat Cooling connection ready On-Demand Zone connection ready Boiler loop circulation X Flow rate stability X Taco 007 circulator or equivalent UL rated cirulator and piping to ensure 10 GPM (+- 2 GPM) flow rate Hydraulic separation of boiler and distribution loops Air elimination X Air vent Pressure relief X Atmosheric venting, pressure relief valve Fluid fill X Boiler drain Low temperature protection X Thermostatic 3-way 1" mixing valve Cavitation protection X Low fluid protection X Power failure and overheat protection X Boiler loop design that ensures sufficient head at the circulator inlet McDonnel & Miller FS-251 flow switch or equivalent UL rated device Taco 1" normally open Zone Sentry valve, power supply, gravity loop design, and piping Greenwood Clean Energy, Inc 5 of 5