UV lamp - SP INSTALLATION AND USER GUIDE SP-V SP-IV SP-III SP-II SP-I. Please, carefully read the instructions. Dangerous radiation UV-SP



Similar documents
Power consumption (kw)

Ultraviolet Germicidal Lamps Owner s Manual MODELS 1910 & 1930

UV Disinfection Systems A Series. Main Applications: Drinking Water, Process Water, Warm Water / Legionellae. IT T Industries Engineered for life

Cal Water 1961 Petra Lane, Placentia, CA (800) CAL-WATER (800) FAX: (714)

Operating Instructions Bedienungsanleitung Mode d emploi

UV100A Ultraviolet Air Treatment System

National- Spencer Inc.

Stenner Pump Chlorinator Installation & Start Up Guide

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

Shielding Ourselves from Ultraviolet Light

Keeping Your Swimming Pool and Spa Healthy Environmental Health Guide

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

Installation Instructions

6x 54w SuperZoo T5 HIGH FREQUENCY ELECTRONIC CONTROLLER LUMINAIRE

Ultra-Violet Products Ltd 2066 W 11th Street, Upland, CA Unit 1, Trinity Hall Farm Estate

WSD130 SOLDERING STATION

Troubleshooting Salt Generators

Owner s Manual

DIAMOND Retractable Rodding Robot Model SPRAYROD-R

Active Monitor Box McCrypt S.T.E.V.E. 15. Order No

Installer s Guide WARNING: 18-GJ11D1-2. Ultraviolet (UV-C) Lamp Kit for 2-5 Ton Air Handlers HAZARDOUS VOLTAGE - DISCONNECT POWER BEFORE SERVICING

1. CONGRATULATIONS! You have bought a great new product from MAGICFX.

WARNING: Ensure that the UV is switched off at the mains before you attempt to conduct any type of maintenance on the EazyPod Complete.

Introduction to Use of UV Light For the Control of Air Handler Contamination. What is UVGI or Ultraviolet Light?

Make your home a healthier home

Sap Steady UV Unit for Maple Sap

Quick start guide smart.power smart.power smart.power

What To Do When Your Well is Flooded. Common Sense Steps To Take If Your Well Is Covered by Flood Water

When you switch off your system, or mute the sound, the red indicator light appears immediately, indicating that the subwoofer is not in use.

PNEUMATIC - HIGH PRESSURE FLAT-FORM HEAVY LIFTING BAGS

BF Series Sa S n u d p Fe i r l C t l e e r a n Installation Manual -1-

AQUADA UV Eliminate Bacteria in Your Drinking Water!

Daily use. Never use alcohol or other solvents to clean any part of the loudspeakers!

SERVICE MANUAL Order No.WH0911S001V0

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Please also see 10 golden rules for correct Saniflo installation on

UNITOR VACUUM cleaners

OPERATING INSTRUCTIONS

3 WATT LED SPOTLIGHT Model No. SLM

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Heated throw User manual

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

Treasure Cove Metal Detector

Winterizing Your Trailer and Storage Ideas

SunMaxx Solar Filling Station Operating Instructions

PBX Series Quick Fit Connector Bimetallic Steam Traps

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

DETERMINING WHICH COLOR UV BEAD CHANGES COLORS THE FASTEST

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance

Flame Direct Attach UV-VIS Integrated Sampling System Installation and Operation Instructions

WATER VALVE OWNER S MANUAL REV051811

VOYAGER 570G. 744A Sprayer Control

SPLIT WALL MOUNTED TYPE AIR CONDITIONERS OWNER'S MANUAL

USB-ISS-UV/VIS Integrated Sampling System Installation and Operation Instructions

If you are familiar with these matters, then you can use this manual as a work of reference.

INSTALLATION & OPERATING INSTRUCTIONS

GENUINE PARTS INSTALLATION INSTRUCTIONS

Quickstart. English Deutsch Français

INTRODUCTION WARNING S!!! VOC SHOULD BE BETWEEN MUST NOT EXCEED 96 VOC USE DC CIRCUIT BREAKER/ISOLATOR BETWEEN SOLAR PANELS & CONTROLLER

OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER

Instructions: Part I. Charge the Power Bank. Method 1. Charge the Power Bank via Computer USB Terminal.

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

LUCCI AIRFUSION QUEST II CEILING FAN

Job Description. Water Plant Treatment Operator. Water Treatment Plant Operator 5/30/2005 Page 1

ZAPPY 3 OWNER S MANUAL. Read this manual completely before riding your Electric ZAPPY 3.


LED PAR 64 SHORT FLOOR 20X3W PWM RGB

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

Today, healthcare facilities must be prepared to face

Portable Air Conditioner

REPAIR AND MAINTENANCE MANUAL

1 DESCRIPTION OF THE APPLIANCE

SIBIR MANUAL V110 KE. English page 5 RKE - 1D

Unit 24: Applications of Pneumatics and Hydraulics

19 LED Tube Controller ORDERCODE 41003

Ultrasonic support removal tank

Front axle components, overview

COLUMBIA UNIVERSITY HEALTH SCIENCES DIVISION

Maintenance Guide For Above Ground Pools

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

Innovation and Progress in Water Treatment Technology

Achat 208 HL / 208 HR passive mid-range speaker. user manual

FLOAT SWITCHES FLOW SWITCHES FOR LIQUIDS PRESSURE SWITCHES

15GAL STEEL OIL DRAIN WITH 110V PUMP

LED 18W/12V SWIMMING POOL LIGHT WITH REMOTE CONTROL INSTALLATION AND OPERATING INSTRUCTIONS

SWIMMING POOL HEAT PUMP

SWIMMING POOL HEAT PUMP Owners Manual

7 FUNCTION DIGITAL MULTIMETER

Installation Manual. Thermomax Solar Water Heater ... Installation Procedure for Flatroof and Ground. Revision 8

2-SLICE COOL TOUCH TOASTER

Please keep these operating instructions in a safe place.

9W T8 LED TUBE 2FT GENERAL INFORMATION

IH E Sigma Island 90

GF SERIES 1-TANK/2-TANK ELECTRIC FRYER USER S MANUAL

NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL

MEASURING & CONTROL UNITS FOR PUBLIC SWIMMING POOLS

LED Par 56 Ultra Bright RGB Black ORDERCODE Polished ORDERCODE 42451

Transcription:

UV lamp - SP SP-V SP-IV SP-III SP-II SP-I INSTALLATION AND USER GUIDE i Please, carefully read the instructions UV-SP Dangerous radiation

SP set SP-I, SP-II, SP-III, SP-IV, SP-V Introduction Before the first use, please read instructions carefully for this installation. In order to use this device safely, follow the security recommendations. Operation The UV lamps produce UV-C (ultra-violet) radiation of a wave length of 253,7nm that has bactericidal effects (it kills bacteria). The SP UV product provides clean, fresh and clear water through a simple and efficient method, and with regard to the environment. The water is pumped through the UV unit. The water inside is exposed to UV-C radiation of the wave length of 253,7nm produced by a special lamp. This installation kills bacteria, viruses and other primitive organisms and prevents their reproduction. In consequence of the length of the unit the water is exposed to a bigger amount of radiation for a prolonged period. Besides, the stainless interior reflects the UV-C radiation and increase the efficiency of the installation of 35%. The stainless interior is refined by the electrolyse process and thus prevent the dirt from sticking to the surface and keep the maximal reflectance. With the SP UV product your water will be efficiently and safely disinfected and you will obtain the high-quality water. Advantages of the water modification by the UV lamps Obtaining fresh, clean and clear water Efficient and safe water disinfection Your pool will be protected against pathogenic organism Minimizing of mould, bacteria and algae creation Can reduce the percentage of chlorine and other chemicals by up to 80% Prevent the creation of a chlorine smell and skin and eyes irritation (red eyes) Procedure is respectful of the environment in comparison with traditional methods SP UV characteristics Thanks to the inner reflection the efficiency is up to 35% higher Stainless reflection interior refined by an electrochemical way that minimize dirt sedimentation UV lamp with 8,000 hours lifetime Easy installation, maintenance and cleaning 2

Direction for use 1. This installation is able to kill harmful bacteria and fold in the pool and provides thus a healthy environment. 2. If the ultra-violet radiation of the wave of length 253,7nm operates for a short term, bacteria and germs will be destroyed in the water. 3. This installation does not belong to the water pump. Buy it separately. 4. Connect the UV lamp to the pipe circuit of the displacement behind the filtration container. 5. Connect the admission pipe to the water pump displacement. 6. Connect the admission pipe to another filter or to the pool and fix it. After checking the pipe and the connection piece, the water circulation can be turned on. 7. After turning the water circulation on, incline the lateral surface of this installation and bleed the pipe or the lateral surface. Check after several minutes if the water circulation operates in an appropriate way. 8. The UV lamp will operate while turning the electric supply on. 9. Fix the grounded cable to the tightening bold of the holder (8)!!! 10. Only authorized person with an appropriate qualification can execute mounting and mending. 11. Do not insert any material (paper, rubber, etc.) between the holder (8) and the body of the UV-lamp that would obstruct from earthing. Warning 1. Place the UV lamp in such a way that it is not immersed in the water. It is not possible to use this installation under the water. 2. The electric supply of the UV lamp must not be turned on before the water start circulation. 3. Place the UV lamp on the stable and safe place because the UV light tube is made from the silica glass and can be easily broken. 4. All components must be installed before switching on the electric supply. 5. If the UV light tube seems to be broken or the lateral surface appears broken, do not use the installation. 6. Electric supply must be operated only by a qualified electrician. 7. Make sure that use of the voltage and frequency is in conformity with specifications on the tag of he UV lamp. 8. It is necessary to follow local installation regulations while installing the mechanism. 9. It is forbidden to pull the connector cable. Protect the connector cable against heat, grease and sharp objects. 10. Make sure that the pressure effecting on the lateral surface is not higher than 0,3 bar. 11. Do not place any stop valves between the lateral surface and the connector pipe of the pool. If it be to the contrary, it would influence the hydraulic pressure effecting the lateral surface. 12. If the frost is supposed to come, remove the UV installation. 13. Do not exposed the UV lamp on the direct sun. 14. The dirt on the silica glass tube will effect the efficiency of the installation, do clean the silica glass tube when necessary. 15. To ensure the efficiency of the installation, it is necessary to exchange the UV light tube after 8,000 hours of the use. 16. If the lateral surface is blocked by sand or dirt, the silica glass tube can be damaged. Do place a sieve in the water pump suction. 3

17. The UV lamp is harmful to your eyes and skin. Do not look directly at the UV lamp and do not make any contact with your skin. 18. While installing or mending this installation, switch off the electric supply. 19. This installation produces dangerous radiation. The direct contact might be dangerous for eyes and skin. Do check the UV lamp through transparent connections of the unit. TECHNICAL SPECIFICATIONS Type SP-I SP-II SP-III SP-IV SP-V Voltage 230V 230V 230V 230V 230V Power 16W 40W 65W 85W 85W Maximum flow 6000 l/h 9000 l/h 12000 l/h 15000 l/h 20000 l/h Maximum pressure 3 bars 3 bars 3 bars 3 bars 3 bars Mounting Warning: The UV lamp and the silica glass tube can be easily damaged. Be careful while detaching the lamp and silica glass tube or while putting these components back! Warning: The ultra-violet rays killing bacteria are harmful to your eyes and skin. List of components: 1. waterproof brushing 2. aluminium nut 3. lamp holder and supply lead of the lamp 4. ultra-violet lamp killing bacteria 5. rubber O-ring 6. silica glass tube 7. chest 8. holder 9. feeder 4

Recommendations for maintenance For the correct function and maintenance of the sterilizer, the user must make following service: I. Cleaning or exchange of the silica glass tube: 1. It is necessary to clean the silica glass tube every three to six months. Clean it by the use of alcohol or a detergent. 2. The silica glass tube has to be changed every 24 months. II. The exchange of the UV lamp is recommended every 8,000 to 9,000 hours of the operation (approximately 12 months of permanent running. 1. Remove the waterproof brushing (1) and unscrew the nut (2). 2. Run out carefully the lamp (4) about 5cm from the chest (7). 3. While holding the end of the lamp(4), remove carefully the lamp socket (3) from the exposed end. 4. Pull out carefully the lamp (4) from the chest (7). 5. Remove carefully the O-ring from both ends of the silica glass tube (6). 6. Remove carefully the silica glass tube (6). 7. Connect the grounded cable (10) on the holder (8). Distance between input and output Total length without supply lead of the lamp NOTE: LINE CONNECTOR AND SUPPLY LEAD OF THE LAMP CUT OUT DO TO INCOMPREHENSIBILITY MODEL A B C D SIZE OF INPUT AND OUTPUT SP-I 276 175 155 420 1 1/2 SP-II 786 175 155 930 1 1/2 SP-III 786 175 155 930 1 1/2 SP-IV 786 175 155 930 1 1/2 SP-V 786 175 155 930 1 1/2 5

Knee Knee Place of using Water supply Output pipe to place of using must be as short as possible. Valve Valve Connector Connector View of the end View of the end Notes: 1. Install the UV lamp on the accessible and properly illuminated place to faciliate inspections and maintenance. 2. Do not let the UV lamp get frozen. 3. Maximum recommended temperature of the environment is 32,2 C. 4. Standard supplies provided 120V/60Hz a 230V/50Hz 5. Maximum recommended operating pressure is 3 BARS 6

Conditions of guarantee Conditions of guarantee abide by the trading and guarantee conditions of your supplier. Secure disposal of the product after the lifetime expiry After the lifetime expiry, ensure its ecologic disposal made by a skilled company Complaints and customer service Complaints abide appropriate consumer protection rights. In the event of unrecoverable effect address the written complaint to your supplier. Date... Supplier 7