Metal Building Insulation



Similar documents
OUTSTANDING CHARACTERISTICS OF TEKFOIL HI-PERFORMANCE REFLECTIVE INSULATION

Product Guide Specification

DELTA Premium Moisture Management Systems for Foundations.

HI-PERFORMANCE REFLECTIVE INSULATION. The most versatile insulation CONTRACTOR INFORMATION AND INSTALLATION GUIDE

Self-Stick Roofing Solutions

Foundation. Foundation

Peel & Seal Self-Stick Roofing Solutions

2014 British Columbia Building Code Changes

Comment Form on Proposed Gut Rehabilitation Alternatives

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

Condensation Fact Sheet METAL BUILDING MANUFACTURERS ASSOCIATION

DIVISION 23 HEATING, COOLING, AIR CONDITIONING AND VENTILATION

COMMERCIAL BUILDING APPLICATIONS

SECTION PRE-ENGINEERED BUILDING BLANKET INSULATION

Roof Insulation Building. Energy. Environment friendly e-library

Fiberglas, Exterior Wall Thermal Insulation

THE DOW CHEMICAL COMPANY Issued: August 1, LARKIN CENTER 1605 JOSEPH DRIVE MIDLAND MICHIGAN (989)

Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Renovating Your Basement

s ation lic app ntial Foamular sideor RE uide F Ily G am ation F sul In

CHAPTER 3 MOISTURE TESTING

The Closed Crawl Space: Making the Transition Climate Zones 3A & 4A

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Best Practices for Crawl Space Insulation

Tsawwassen BC Arena Before & After installation of the Low-E ceiling

CHAPTER 7: Building Systems ROOFING SYSTEMS

B. ASTM C 533 Calcium Silicate Block and Pipe Thermal Insulation. C. ASTM C 547 Mineral Fiber Preformed Insulation

Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

APPENDIX C MOISTURE GUIDELINES & MOISTURE TESTING

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

GigaCrete Specification PlasterMax

Interior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

Building Envelope Design using ROXUL. FIREWALL and ROXUL PLUS MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

Article. Protecting the Building Envelope from Water Damage. MemBrain Smart Vapor Retarder & Air Barrier Film

How To Test A Wrap N Drain X Dampproofing System

ROOFS, SNOW AND ICE DAMS

ENERGY STAR Qualified New Homes Thermal Enclosure Checklist. Water Management Checklist. Eli Caudill

Underwriters Laboratories Testing Information

5 Things. You Must Know. Before Buying. Radiant Barrier

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

Rockwool Flexi Insulation Application Guide

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Residential Foundations and Basements

SECTION HVAC INSULATION. A. All work specified in this Section is subject to the provisions of Section

INSULATION FOR PRE-ENGINEERED METAL BUILDINGS. ROXUL SAFE 55 & 65 and ROXUL PLUS MB. Insulation for Pre-Engineered Metal Buildings

FOAMULAR LT40, 400 and 600 insulations with minimum compressive strengths of

Chapter 2: Foundations

09990 MOLD REMEDIATION, LEAD-BASED PAINT ABATEMENT AND ENCASEMENT OF ASBESTOS

Guide Specifications for Maple Flooring Systems

Industrial Attachment Tapes X-Series. Value, Performance. & Quality. Simply X.

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

Fire-Rated Glass and Glazing START

FLEX-WRAP Foam Pipe Wrap

Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description

Please read the entire document before purchasing and installing any of these products

United States. Why You Should Insulate Foundations. There is a science to adding value.

The Optimum Basement Wall

EPDM. Roofing systems

CONDENSATION. Section Break (Next Page)

Mold Preventing I nterior System

4 Installation Requirements

Avoiding Air Barrier Pitfalls

ICC-ES Evaluation Report. ESR-3493 Reissued September 2014 This report is subject to renewal September 2015.

Additions and Alterations

Built to Last. Built for Beauty. Good. Solid. Logix. TM

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

*Trademark of The Dow Chemical Company A business unit of The Dow Chemical Company and its subsidiaries Copyright 2003 The Dow Chemical Company.

Chapter 3 Pre-Installation, Foundations and Piers

Housing Fact Sheets. Moisture Condensation at the Windows

Best Basement Water Management Practices

State of Connecticut Department of Public Health RADON PROGRAM

Twiga Insul. India's Leading Thermal and Acoustic Insulation. Insulating India

Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited**

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

DRAINAGE MATS For Vertical: Flow 15-P For Horizontal: Flow 18-H

Moisture and Resilient Floor Covering

Basements are Changing. Basements Part of the Enclosure. Basements. Energy Efficient, Durable, Healthy. Below grade enclosure

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

DUPONT TYVEK BUILDING WRAPS VS. ZIP SYSTEM WALL SHEATHING

THERMAL INSULATION MATERIALS TEST METHOD SELECTION LIST

2009 IECC Update. Scope. Content. International Energy Conservation Code

How to Install Hardwood Flooring Over a Sub Floor

THE IC Y N E N E AD V A N T A G E

Presented by: Jennifer Doyle, P.E., RRC, LEED AP

Multi-layer Insulation Blanket for Roofs

The Perfect Fit For Metal Retrofit

R E S I D E N T I A L H O U S I N G

SECTION FIBERGLASS INSULATION

Athena is the name given to our assortment of electronic tapes. products of the very highest quality. These tapes both conduct and

GreenGuard Housewrap Installation Guide

HOW TO INSULATE A CRAWLSPACE

SIMPLE SAVER SYSTEM DESIGN MANUAL

G VYCOR DECK PROTECTOR. For longer lasting decks, install Grace Vycor Deck Protector. It s an easy add-on to your deck projects.

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN Fax: Re-Roofing: Asphalt Shingles

Bella Cera Engineered Hardwood Flooring Installation Instructions. Check for Proper Color Selection Prior to Installation

Open-cell spray foam & what every contractor

referenceguide Reference Guide for Pressure-Sensitive Adhesive Tapes great to work with

Transcription:

Metal Building Insulation Recommended For: Pre-Engineered Steel Buildings Post Frame / Pole Barns Agricultural Buildings Residential Metal Roofs Mini Storage Livestock Confinement Why Install rfil? Blocks 97% of Radiant Heat Transfer Prevents Interior Condensation Class 1 / Class A Fire-Rated (AS E84-08) Puncture and Tear-Resistant Unaffected by Humidity Will not Promote Mold and Mildew Safe, Non-Toxic and Non- Carcinogenic Easy to Handle and Install Various Tab ptions UV-Resistant rfil reflective Insulation is a single or double layer of polyethylene bubbles bonded to and sandwiched between a radiant barrier metalized foil and white polyethylene sheet. rfil is specifically designed to control heat gain or loss, and prevent interior condensation, in all types of metal and metal-clad buildings. Class 1 / Class A Fire Rating AS E84-08

Metal Building Insulation FEATURES Reflective Metalized Aluminum Surface Facing Multi-Layer Bubble Core White Interior Facing ption Practical Tab/Edge ptions QuickSeam (Adhesive Tape on Tab) - Reduces Radiant Heat Gain and Loss - Blocks 97% of Radiant Heat Transfer - Saves Energy Use - Lowers Heating/Cooling Costs - Improves Interior Comfort - Provides Continuous Thermal Break - Lowers Risk of Interior Surface Condensation - Durable and Long-Lasting - Superior Puncture, Tensile and Tear Strength - Will Not Absorb Water or Vapor - Does Not Harbor Moisture or Mold - Clean, Safe, No-Itch Material - Brightens Building Interior - Attractive Appearance - Easy to Clean BENEFITS - Various ptions for All Metal Building Applications - Simplifies Installations - Improves Vapor-Sealing Efforts - Saves Time and Labor - Ensures a Continuous Vapor and Condensation Barrier - Simplifies and Speeds Installation PRDUCTS AVAILABLE IN: - Single or Double Bubble - Square Edge, Tab 1 Side, Tab 2 Sides, Quick Seam Adhesive Strip - Width: 12, 16, 18, 24, 48 and 72 - Length: 102 and 125 - rfil meets AS Class 1 / Class A Testing rfil Approvals - AS E84-08 Fire Test - AS 1225 Standard Specifications for Reflective Insulations and Building Applications NMINAL THICKNESS WEIGHT TEMPERATURE RANGE - AS C411 FLAME SPREAD (AS E84-08) SMKE DEVELPMENT (AS E84-08) FIRE RATING - AS E84-08 EMISSIVITY - AS C1371 REFLECTIVITY - AS 3903 WATER VAPR PERMEANCE - AS E96, NGC 51.33-M89 TENSILE AND ELNGATIN - AS D882 TENSILE AND ELNGATIN - AS D882 LINEAR SHRINKAGE FLEXIBILITY - CAN / CGSB-51.33 M89 RESISTANT T FUNGI AND BACTERIA SPECIFICATINS DUBLE Specific Applications and Installation Guides can be found on our Applications Manuals SINGLE 5/16 3/16 0.78 oz/sq.ft 0.47 oz/sq.ft -50 F to 180 F 0 15 CLASS 1 / CLASS A 0.03-0.04 0.96-0.97 < 0.01 Perms MACHINE 69 lbs/sq.in (173%) TRANSVERSE 75 lbs/sq.in (194%) NNE N CRACKING DES NT PRMTE GRWTH MANUFACTURED BY CVERTECH FABRICATING INC International REFLECTIVE INSULATIN MANUFACTURERS ASSCIATIN 555 Lawton Ave. Beloit, WI 53512 p. 608.365.2161 Toll Free. 800.766.2825 f. 800.834.7447

Metalized Foil Barrier Recommended For: Commercial Buildings Residential Buildings Manufactured Homes Mobile Homes DIY Applications And much more... Insulates: Walls Ceilings Crawl Spaces Basement Walls Attic Between Joists Why Install rfil? Staple Tabs for Between Joists Minimal Product Thickness Easy to Handle and Install Vapor Barrier Protection Increases Insulating Value of Wall Systems rfil reflective Insulation is a single or double layer of polyethylene bubbles bonded to and sandwiched between two radiant barrier metalized sheet. Its unique construction is specially designed to reduce radiant heat gain or loss in Residential, Commercial and HVAC applications while increasing comfort. Class 1 / Class A Fire Rating AS E84-08

Metalized Foil Barrier FEATURES Square edge configuration for normal edges BENEFITS - Square edge metalized rfil is a multi purpose insulation - Easily cut and configured around obstacles - Tape seals can be made at any angle 1 tabs running the length of the rfil - Staple tabs can be stapled between joists - Allows for quick and easy installation - Helps create the air space necessary Tabs equipped with tape running the length of the rfil - Quick seam tabs can be used in place of rfil tape - Seals the seams with ease - Seals the metalized rfil in order to avoid breaks in the insulation PRDUCTS AVAILABLE IN: - Single or Double Bubble - Square Edge, Tab 1 Side, Tab 2 Sides, Quick Seam - Width: 12, 16, 18, 24, 36 and 72 - Length: 50, 75, 100, 102 and 125 NMINAL THICKNESS WEIGHT TEMPERATURE RANGE - AS C411 FLAME SPREAD (AS E84-08) SMKE DEVELPMENT (AS E84-08) FIRE RATING (AS E84-08) EMISSIVITY - AS C1371 REFLECTIVITY - AS 3903 WATER VAPR PERMEANCE - AS E96, NGC 51.33-M89 TENSILE AND ELNGATIN - AS D882 TENSILE AND ELNGATIN - AS D882 CRRSIVITY LINEAR SHRINKAGE FLEXIBILITY - CAN / CGSB-51.33 M89 RESISTANT T FUNGI AND BACTERIA SPECIFICATINS SINGLE 3/16 0.47 oz/sq.ft -50 F to 180 F 0 20 CLASS 1 / CLASS A 0.03-0.04 (FIL Side) 0.96-0.97 (FIL Side) < 0.01 Perms 94 lbs/sq.in (375%) 91 lbs/sq.in (368%) Not Applicable NNE N CRACKING DES NT PRMTE GRWTH Specific Applications and Installation Guides can be found on our Applications Manuals DUBLE 5/16 0.74 oz/sq.ft -50 F to 180 F 0 20 CLASS 1 / CLASS A 0.03-0.04 (FIL Side) 0.96-0.97 (FIL Side) < 0.01 Perms 94 lbs/sq.in (340%) 91 lbs/sq.in (322%) Not Applicable NNE N CRACKING DES NT PRMTE GRWTH rfil Code Compliance International code council ( ICC) report ESR-1236 MANUFACTURED BY CVERTECH FABRICATING INC The above report has been issued based on rfoil compliant with the below codes: - 2006 international building code (IBC) - 2006 international residential code (IRC) - 1997 Uniform building code (UBC) International REFLECTIVE INSULATIN MANUFACTURERS ASSCIATIN 555 Lawton Ave. Beloit, WI 53512 p. 608.365.2161 Toll Free. 800.766.2825 f. 800.834.7447

286 Fire Retardant Metal Building Insulation Recommended For: Pre-Engineered Steel Buildings Post Frame / Pole Barns Agricultural Buildings Residential Metal Roofs Mini Storage Livestock Confinement Any Structure with Strict Fire Safety Requirements Why Install rfil? Blocks 97% of Radiant Heat Transfer Prevents Interior Condensation Class 1 / Class A Fire-Rated (AS E84-08) Puncture and Tear-Resistant Unaffected by Humidity Will Not Promote Mold and Mildew Safe, Non-Toxic and Non- Carcinogenic Easy to Handle and Install Various Tab ptions UV-Resistant rfil286 Reflective Insulation is a single layer of ¼ high-strength polyethylene bubble, bonded to and sandwiched between a layer of metalized aluminum film, with an interior facing of UV-Resistant polyethylene. rfil286 Reflective Insulation is patented, and specifically designed for applications that require strict code compliance for exposed insulation and fire safety. rfil286 has a Class 1 / Class A fire rating (AS E84-08), and successfully meets the requirements of the NFPA Full Corner Room Burn Test. Passes NFPA 286 Full Room Burn Test

286 Fire Retardant Metal Building Insulation FEATURES Patented Fire-Retardant Design and Composition Reflective Metalized Aluminum Surface Facing Multi-Layer Bubble Core White Interior Facing ption Practical Tab/Edge ptions QuickSeam (Adhesive Tape on Tab) PRDUCTS AVAILABLE IN: - Quick Seam Adhesive Strip or Tab 2 sides - Width: 48 and 72 - Length: 102 and 125 Specific Applications and Installation Guides can be found on our Applications Manuals rfil Approvals - NFPA 286 Full Corner Room Burn Test - AS E84-08 Fire Test - AS 1225 Standard Specifications for Reflective Insulations and Building Applications International REFLECTIVE INSULATIN MANUFACTURERS ASSCIATIN BENEFITS - Class 1 / Class A Fire Rating (AS E-84-05) - Passes the NFPA 286 Full Corner Room Burn Test - Safest Reflective Insulation Available - Reduces or Eliminates Fire-Related Liability - Reduces Radiant Heat Gain and Loss - Blocks 97% of Radiant Heat Transfer - Saves Energy Use - Lowers Heating/Cooling Costs - Improves Interior Comfort - Provides Continuous Thermal Break - Lowers Risk of Interior Surface Condensation - Superior Puncture, Tensile and Tear Strength - Durable and Long-Lasting - Does Not Harbor Moisture or Mold - Will Not Absorb Water or Vapor - Clean, Safe, No-Itch Material - Brightens Building Interior - Attractive Appearance - Easy to Clean - Various ptions for All Metal Building Applications - Simplifies Installations - Improves Vapor-Sealing Efforts - Saves Time and Labor - Ensures a Continuous Vapor and Condensation Barrier - Simplifies and Speeds Installation SPECIFICATINS PLY / 1/4 BUBBLE / REFLECTIVE 1/4 0.78 oz/sq.ft -50 F to 180 F CLASS 1 / CLASS A CNFRMS 0.03-0.04 0.96-0.97 < 0.01 Perms NMINAL THICKNESS WEIGHT TEMPERATURE RANGE - AS C411 FIRE RATING - AS E84-05 FIRE RATING NFPA 286 EMISSIVITY - AS C1371 REFLECTIVITY - AS 3903 WATER VAPR PERMEANCE - AS E96, NGC 51.33-M89 TENSILE AND ELNGATIN - AS D882 TENSILE AND ELNGATIN - AS D882 CRRSIVITY LINEAR SHRINKAGE FLEXIBILITY - CAN / CGSB-51.33 M89 RESISTANT T FUNGI AND BACTERIA MACHINE 69 lbs/sq.in (173%) TRANSVERSE 75 lbs/sq.in (194%) 200 F - 7 Days NNE N CRACKING DES NT PRMTE GRWTH MANUFACTURED BY CVERTECH FABRICATING INC 555 Lawton Ave. Beloit, WI 53512 p. 608.365.2161 Toll Free. 800.766.2825 f. 800.834.7447

Concrete Underpad Recommended For: Insulating Under Concrete Slabs Beneath Concrete ver-pours Edge-Slabs and Expansion Joints Why Install rfil? Reduces Radiant Heat Loss through Floors High-Strength, Multi-Layer Vapor and Radon Barrier (7 mil) Cost-Effective Alternative to Rigid Foam Insulation Improves Efficiency of In-Floor Radiant Heating Systems Reduces Slab Reaction Time at System Startup Saves Energy Usage and Utility Costs Easy to Form around bstructions Installs Easily ver any Grade Withstands Job Site Traffic rfil Concrete Underpad is an outstanding reflective insulation and puncture-resistant vapor barrier. It is composed of a double layer of highstrength polyethylene bubbles (up to 60 psi), sandwiched between one layer of metalized aluminum, and a layer of white polyethylene. rfil Concrete Underpad provides exceptional thermal value and a strong, permanent vapor and radon barrier. It is a cost-effective alternative to rigid foam insulation, and is always installed with the white side facing upwards. Class 1 / Class A Fire Rating AS E84-08

Concrete Underpad FEATURES Reflective Metalized Aluminum Facing (installed facing down) White Polyethylene Facing Multi-Layer 7 mil Bubble Core Lightweight, Flexible Materials BENEFITS - Reduces Radiant Heat Loss - Redirects Radiant Heat Energy Back to Living Area - Saves Energy Usage and Lowers Heating Costs - Extends Life of Heating System - Faster Reaction Time for Radiant Floor Heating - Unaffected by Lime and other Corrosive Chemicals, often Found in Concrete. - Provides Continuous Thermal Break below the Slab - Keeps underground moisture away from slab - Durable and Long-Lasting Polyethylene - Strong Puncture Resistance and Tear Strength - utstanding Vapor and Radon Barrier - Can also Insulate the Edge-Slab and utside of Foundation - Just Unroll, verlap, and Tape the Seams - Easy to Cut and Configure around bstructions - Ideal for Edge-Slab Insulation and Expansion Joint (Easily Folds Upward at Perimeter Footing) PRDUCTS AVAILABLE IN: - Configurations: Square Edge - Width: 48 - Length: 125 Testing NMINAL THICKNESS WEIGHT TEMPERATURE RANGE FLAME SPREAD (AS E84-08) SMKE DEVELPMENT (AS E84-08) THERMAL RESISTANCE SPECIFICATINS FIRE RATING EMISSIVITY REFLECTIVITY WATER VAPR PERMEANCE TENSILE STRENGTH (CAN/CGSB - 51.33-M89) LINEAR SHRINKAGE FLEXIBILITY (CAN/CGSB - 51.33-M89) RESISTANT T FUNGI AND BACTERIA Specific Applications and Installation Guides can be found on our Applications Manuals FIL / Double Bubble / PLY 5/16 0.82 oz/sq. ft. 0 0-50 F to 180 F 0 15 See tech sheets for R-Value in specific applications CLASS 1 / CLASS A 0.03-0.04 0.96-0.97 (FIL side) <0.01 Perms 21.13 lbs/sq. in. NNE N CRACKING DES NT PRMTE GRWTH More Benefits - Warmer, More Comfortable Floors - Conforms Easily to Uneven Grades - Strongly Bonded to Resist Delamination - Sealed Seams Provide a Consistent Insulation MANUFACTURED BY CVERTECH FABRICATING INC International REFLECTIVE INSULATIN MANUFACTURERS ASSCIATIN 555 Lawton Ave. Beloit, WI 53512 p. 608.365.2161 Toll Free. 800.766.2825 f. 800.834.7447

ULTRA CBF Concrete Barrier Foil Recommended For: Insulating Under Concrete Slabs In-Floor Radiant Heating Beneath Concrete ver-pours Edge-Slabs and Expansion Joints utside Foundation Walls Snow Melt Systems Under Carpet Why Install rfil? Reduces Radiant Heat Loss through Floors Multi-Layer Vapor and Radon Barrier (10 mil) Cost-Effective Alternative to Rigid Foam Insulation Improves Efficiency of In-Floor Radiant Heating Systems Saves Energy Usage and Utility Costs Easy to Form around bstructions Installs Easily ver any Grade Withstands Job Site Traffic Patent No. US 6,562,439B2 US 6,514,596B1 Ultra CBF is an outstanding reflective insulation and puncture-resistant vapor barrier. Ultra CBF is composed of a single layer of pure aluminum, laminated between two layers of ultra-strong polyethylene bubble (up to 140 psi). Ultra CBF is the ultimate under-slab insulation. It provides exceptional thermal value and a strong, permanent vapor and radon barrier. Ultra CBF typically costs less than 2 rigid PE board insulation. Ultra CBF is easier to handle, cut, and install than rigid foam insulation, yet has nearly six times the compression strength. Class 1 / Class A Fire Rating AS E84-08

ULTRA CBF Concrete Barrier Foil FEATURES Reflective Aluminum Inner Layer Multi-Layer 10 mil Bubble Core Lightweight, Flexible Materials BENEFITS - Reduces Radiant Heat Loss - Redirects Radiant Heat Energy Back to Living Area - Saves Energy Usage and Lowers Heating Costs - Extends Life of Heating System - Faster Reaction Time for Radiant Floor Heating - Provides Continuous Thermal Break below the Slab - Keeps Underground Moisture Away from Slab - Durable and Long-Lasting Polyethylene - Superior Puncture Resistance and Tear Strength - utstanding Vapor and Radon Barrier - Can also Insulate the Edge-Slab and utside of Foundation - Simply Unroll, verlap, and Tape the Seams - Easy to Cut and Configure around bstructions - Ideal for Edge-Slab Insulation and Expansion Joint (Easily Folds Upward at Perimeter Footing) PRDUCTS AVAILABLE IN: - Configurations: Square Edge - Width: 48 - Length: 125 SPECIFICATINS NMINAL THICKNESS WEIGHT TEMPERATURE RANGE EMISSIVITY REFLECTIVITY WATER VAPR PERMEANCE - AS E96, NGC 51.33-M89 TENSILE STRENGTH (CAN/CGSB - 51.33-M89) DEFLECTIN (AS 1621) PUNCTURE RESISTANCE CMPRESSIVE STRENGTH LINEAR SHRINKAGE FLEXIBILITY (CAN/CGSB - 51.33-M89) RESISTANT T FUNGI AND BACTERIA Specific Applications and Installation Guides can be found on our Applications Manuals 5/16 1.16 oz/sq. ft. 0 0-50 F to 180 F 43% 57% <0.01 Perms 21.13 lbs/sq. in. <10% under 0.5 psi 85 lbs/sq. in. 140 psi NNE N CRACKING DES NT PRMTE GRWTH More Benefits - Warmer, More Comfortable Floors - Conforms Easily to Uneven Grades - Strongly Bonded to Resist Delamination - Sealed Seams Provide a Consistent Insulation - Will not deteriorate over time - Aluminum Radiant Barrier Permanently Protected from - Corrosive Ground Elements, such as Lime and Soil Alkaline International REFLECTIVE INSULATIN MANUFACTURERS ASSCIATIN MANUFACTURED BY CVERTECH FABRICATING INC Patent No. US 6,562,439B2 US 6,514,596B1 555 Lawton Ave. Beloit, WI 53512 p. 608.365.2161 Toll Free. 800.766.2825 f. 800.834.7447

Adhesive Tapes Recommended For: All rfil Insulation Products and Related Applications Maintaining a Vapour Barrier and Constant Insulator Seals: Seams Gaps Tab sections Rips Tears Why Install rfil? Economical Quick and Easy to Install Approved Vapour Barrier Available in a Variety of Sizes to Suit Your Needs APPRVED VAPUR BARRIER rfil Adhesive Tapes are available in two varieties: White Poly and Metalized Foil. Both rfil tapes provide an excellent vapour barrier seal and are specifically designed for use with all rfil Insulation Products. Acrylic pressure sensitive adhesive combines superior quick-stick at normal temperatures, with excellent low temperature performance below freezing.

Adhesive Tape FEATURES Aluminium Tape - Soft, Metalized Foil - Pressure Sensitive Acrylic Adhesive White Poly Tape - Polypropylene Material - Acrylic Adhesive BENEFITS - Conforms to irregular surfaces - Maintains reflective / radiant barrier - Adheres well to rfil, sheet metal, and more! - Effective in hot and cold climates - Forms strong bond for long life adhesion - Durable to withstand installation - Adheres to any polyethylene or related material - Conforms to foil or poly to give the seamless look - Will adheres to poly or aluminium faced rfil - Adheres in all four seasons - Will seal seams effectively for many years PRDUCTS SPECIFICATINS AVAILABLE IN: - Metalized Foil or White Poly - Lengths: 30 and 150 - Widths: 2 and 3 THICKNESS ADHESIN PEEL (PSTC #1) SHEAR (PSTC #7) TENSILE (PSTC #7) ELNGATIN (PSTC #31) MIN TEMPERATURE APPLICATIN TEMP RESISTANCE MLD GRWTH ALUMINIUM 1.3 MILS (.0015 ) 42 oz / inch 2.2 PSI 22 lbs / inch width 150% -305 F 250 F 0 WHITE PLY 3 MILS (.003 ) 16 oz / inch width 2.2 PSI 20 lbs / inch width 136% N/A N/A N/A UL-181B-FX 3 MILS (.003 ) 41 oz / inch width 2.2 PSI 22 lbs / inch width 150% -35 F to 260 F 260 F 0 Specific Applications and Installation Guides can be found on our Applications Manuals MANUFACTURED BY CVERTECH FABRICATING INC International REFLECTIVE INSULATIN MANUFACTURERS ASSCIATIN 555 Lawton Ave. Beloit, WI 53512 p. 608.365.2161 Toll Free. 800.766.2825 f. 800.834.7447