Computer aided monitoring of breast abnormalities in X-ray mammograms



Similar documents
Test Sensitivity in the Computer-Aided Detection of Breast Cancer from Clinical Mammographic Screening: a Meta-analysis

Digital Mammogram National Database

Certification protocol for breast screening and breast diagnostic services

OBJECTIVES By the end of this segment, the community participant will be able to:

VI. FREQUENTLY ASKED QUESTIONS CONCERNING BREAST IMAGING AUDITS

Preprocessing of Screening Mammograms Based on Local Statistical Models

Methodologies for Evaluation of Standalone CAD System Performance

Breast Imaging Made Brief and Simple. Jane Clayton MD Associate Professor Department of Radiology LSUHSC New Orleans, LA

Segmentation of Breast Tumor from Mammographic Images Using Histogram Peak Slicing Threshold

Personalized Breast Screening Service

D. FREQUENTLY ASKED QUESTIONS

Breast Ultrasound: Benign vs. Malignant Lesions

Infrared Thermography Not a Useful Breast Cancer Screening Tool

IAC Ch 41, p.1. Procedure means a stereotactically guided breast biopsy performed on a patient for diagnostic purposes.

Prototype Internet consultation system for radiologists

Medicare Part B. Mammograms - Updated Billing Guide for Screening and Diagnostic Tests

Hologic Selenia Dimensions C-View Software Module. October 24, 2012

Mammography Education, Inc.

Comparing Data Mining with Ensemble Classification of Breast Cancer Masses in Digital Mammograms

Incidence of Incidental Thyroid Nodules on Computed Tomography (CT) Scan of the Chest Performed for Reasons Other than Thyroid Disease

Automated Breast Volume Scanning 3D Ultrasound of the Breast

Official reprint from UpToDate UpToDate

Comparing Methods to Identify Defect Reports in a Change Management Database

Office of Population Health Genomics

Great Strides MARKEY COMPREHENSIVE BREAST CARE CENTER: SETTING A NEW STANDARD OF CARE

Recommendations for cross-sectional imaging in cancer management, Second edition

Breast Cancer Screening in Low- and Middle-Income Countries A Framework To Choose Screening Strategies

Patient Prep Information

Q.A. Collectible. Sponsored by CRCPD s Committee on Quality Assurance in Diagnostic X-Ray (H-7)

Local Coverage Determination (LCD): Screening and Diagnostic Mammography (L29328)

How To Decide If You Should Get A Mammogram

Ductal carcinoma in situ (DCIS)

Review of Biomedical Image Processing

GRID COMPUTING FOR DIGITAL MAMMOGRAPHY

Harlem Hospital Center Integrated Radiology Residency Program Mammography Educational goals and objectives

The File-Card-Browser View for Breast DCE-MRI Data

FP-Hadoop: Efficient Execution of Parallel Jobs Over Skewed Data

Breast Density Legislation: Implications for primary care providers

Examples of good screening tests include: mammography for breast cancer screening and Pap smears for cervical cancer screening.

A pilot study examining nutrition and cancer patients: factors influencing oncology patients receiving nutrition in an acute cancer unit.

Stereotactic Breast Biopsy

Mammography. What is Mammography?

INTERNATIONAL JOURNAL FOR ENGINEERING APPLICATIONS AND TECHNOLOGY DATA MINING IN HEALTHCARE SECTOR.

Breast Cancer. Presentation by Dr Mafunga

How To Write A Draft Report On Breast Cancer Screening

Radiology Physician Performance Measurement Set

Cross-Institutional Evaluation of BI-RADS Predictive Model for Mammographic Diagnosis of Breast Cancer

How To Be A Breast Consultant Radiographer

BREAST CHARACTERISTICS AND DOSIMETRIC DATA IN X RAY MAMMOGRAPHY - A LARGE SAMPLE WORLDWIDE SURVEY

Guideline for the Imaging of Patients Presenting with Breast Symptoms incorporating the guideline for the use of MRI in breast cancer

Detection of clustered microcalcifications in small field digital mammography

Sage Screening Program. Provider Manual

Magic-5. Medical Applications in a GRID Infrastructure Connection. Ivan De Mitri* on behalf of MAGIC-5 collaboration

First Warning Systems, Inc.

Facebook Friend Suggestion Eytan Daniyalzade and Tim Lipus

CONSOLIDATED GUIDANCE ON STANDARDS FOR THE NHS BREAST SCREENING PROGRAMME

Visualization methods for patent data

Evaluation of Stylus for Radiographic Image Annotation

The Role of SPOT Satellite Images in Mapping Air Pollution Caused by Cement Factories

Technical guidelines for magnetic resonance imaging for the surveillance of women at increased risk of developing breast cancer

Evaluation and Management of the Breast Mass. Gary Dunnington,, M.D. Department of Surgery Internal Medicine Ambulatory Conference December 4, 2003

Nicole Kounalakis, MD

Low-dose CT Imaging. Edgar Fearnow, M.D. Section Chief, Computed Tomography, Lancaster General Hospital

How To Compare Mammography To A 3D System

for breast cancer detection

Concepts for High-Resolution Low-Dose CT of the Breast

White Paper. Study to Demonstrate Efficacy of 8MP Color Display - Mammography 1.INTRODUCTION PURPOSE METHODS RESULTS...

2 SYSTEM DESCRIPTION TECHNIQUES

ARTIFICIAL INTELLIGENCE (CSCU9YE) LECTURE 6: MACHINE LEARNING 2: UNSUPERVISED LEARNING (CLUSTERING)

ductal carcinoma in situ (DCIS)

Understanding ductal carcinoma in situ (DCIS) and deciding about treatment

ACR BI-RADS ATLAS MAMMOGRAPHY MAMMOGRAPHY II. REPORTING SYSTEM. American College of Radiology 121

Health. NYC Quality Assurance Guidelines for. Primary Diagnostic Monitors

Q: What differentiates a diagnostic from a screening mammography procedure?

Allegheny Health Network. Breast Care Center

Graph Embedding to Improve Supervised Classification and Novel Class Detection: Application to Prostate Cancer

The Mammography Quality Standards Act Final Regulations Document #1

Application Note. ipix A Gamma imager to support various applications

Early detection through mammography. Early breast cancer detection improved chances of recovery

Registration of X ray mammograms and 3 dimensional speed of sound images of the female breast

Automated Detection of Breast Cancer s Indicators in Mammogram via Image Processing Techniques

Pollination services in the UK: how important are honeybees?

COLORECTAL CANCER SCREENING

BREAST IMAGING. Developed by the Ad Hoc Committee on Resident and Fellow Education of the Society of Breast Imaging

Prediction of Heart Disease Using Naïve Bayes Algorithm

Variability and Accuracy in Mammographic Interpretation Using the American College of Radiology Breast Imaging Reporting and Data System

By Maciej A. Mazurowski M.S., Wroclaw University of Technology, 2005 M.A., University of Wroclaw, 2005

Fall Detection System based on Kinect Sensor using Novel Detection and Posture Recognition Algorithm

Driving Forces in Health Care:

2011 Radiology Diagnosis Coding Update Questions and Answers

COMPARATIVE ANALYSIS OF DATA MINING TECHNIQUES FOR MEDICAL DATA CLASSIFICATION

Provider Reimbursement for Women's Cancer Screening Program

im3d S.p.A. La Ricerca fa Impresa

RESEARCH PAPERS FACULTY OF MATERIALS SCIENCE AND TECHNOLOGY IN TRNAVA SLOVAK UNIVERSITY OF TECHNOLOGY IN BRATISLAVA

Blood Vessel Classification into Arteries and Veins in Retinal Images

Common Breast Complaints:

N E X U S C O P Y N U M B E R H O W T O G U I D E S

A decision support system for breast cancer detection in screening programs

Medical Image Segmentation of PACS System Image Post-processing *

Mammography. For 35+ years, screenfilm has been the gold standard for breast cancer detection

Transcription:

Computer aided monitoring of breast abnormalities in X-ray mammograms SELVAN, Arul, SAATCHI, Reza and FERRIS, Christine Available from Sheffield Hallam University Research Archive (SHURA) at: http://shura.shu.ac.uk/3792/ This document is the author deposited version. You are advised to consult the publisher's version if you wish to cite from it. Published version SELVAN, Arul, SAATCHI, Reza and FERRIS, Christine (2011). Computer aided monitoring of breast abnormalities in X-ray mammograms. In: Medical Image Understanding and Analysis 2011, London, Thursday 14th - Friday 15th July 2011.. Repository use policy Copyright and Moral Rights for the papers on this site are retained by the individual authors and/or other copyright owners. Users may download and/or print one copy of any article(s) in SHURA to facilitate their private study or for noncommercial research. You may not engage in further distribution of the material or use it for any profit-making activities or any commercial gain. Sheffield Hallam University Research Archive http://shura.shu.ac.uk

1 SELVAN, SAATCHI, FERRIS. Computer Aided Monitoring of Breast Abnormalities in X ray Mammograms Arul N. Selvan1 http://www.shu.ac.uk/research/meri/mmvl/r esearch/projects/medical/index.html 1 Materials & Engineering Research Inst. Sheffield Hallam University, Sheffield. UK. Reza Saatchi1 2 Faculty of Health & Wellbeing Sheffield Hallam University, Sheffield. UK. Christine M. Ferris2 Abstract X ray mammography is regarded as the most effective tool for the detection and diagnosis of breast cancer, but the interpretation of mammograms is a difficult and error prone task. Computer aided detection (CADe) systems address the problem that radiologists often miss signs of cancers that are retrospectively visible in mammograms. Furthermore, computer aided diagnosis (CADx) systems assist the radiologist in the classification of mammographic lesions as benign or malignant [1]. This paper details a novel alternative system namely computer aided monitoring (CAM) system. The designed CAM system can be used to objectively measure the properties of a suspected abnormal area in a mammogram. Thus it can be used to assist the clinician to objectively monitor the abnormality. For instance its response to treatment and consequently its prognosis. The designed CAM system is implemented using the Hierarchical Clustering based Segmentation (HCS) [2] [3] [4] process. Brief description of the implementation of this CAM system is as follows : Using the approximate location and size of the abnormality, obtained from the user, the HCS process automatically identifies the more appropriate boundaries of the different regions within a region of interest (ROI), centred at the approximate location. From the set of, HCS process segmented, regions the user identifies the regions which most likely represent the abnormality and the healthy areas. Subsequently the CAM system compares the characteristics of the user identified abnormal region with that of the healthy region; to differentiate malignant from benign abnormality. In processing sixteen mammograms from mini MIAS [5], the designed CAM system demonstrated a success rate of 100% in differentiating malignant from benign abnormalities. 1 Introduction The introduction of systems for automated reading in mammography has been proposed to improve the sensitivity [computer aided detection (CADe) systems] and, more recently, the specificity [computer aided diagnosis (CADx) systems] of the test. Only CADe systems have been approved by the U.S. Food and Drug Administration (FDA) [6]. The first CADe tools were approved by the U.S. FDA for clinical use in 1998. Several commercial and non commercial CAD systems have since become available [7]. CAD systems are trained on a database of mammograms of selected patients before they are used in clinical practice [6]. The method for assessing CAD performance during the 2011. The copyright of this document resides with its authors. Doi:06/06/2011 #46#

2 SELVAN, SAATCHI, FERRIS: Computer Aided Monitoring of Breast Abnormalities in X ray Mammograms. training period is to plot the free response receiver operating characteristic (FROC). This represents the sensitivity of the system in detecting cancer as a function of the averaged number of false positive. The best performing CAD systems will have a low false positive rate as well as high sensitivity [7]. During actual usage CAD system use thresholding algorithms to identify as many true signals and as few false signals as possible. Signal data are separated from the background in a process known as segmentation. The signals are then subjected to a probabilistic analysis to assess the likelihood that the structure on the image contains malignancy induced abnormalities [7]. The final result is a CAD prompt, if the probability of cancer being present is sufficiently high [8]. The exact impact of CAD on radiologists' sensitivity has not been determined. One retrospective study of screening mammograms, involving two different CAD systems, showed that CAD improved the detection of cancers that had been overlooked by a single radiologist. This reduction in false negatives led to an increase in sensitivity from 71.2% for the single radiologist to 84.8% and 80.3% for the two CAD systems [9]. Another study, focusing on the detection of previously missed cancers, demonstrated a sensitivity of 51.5% for CAD, 62.5% for the radiologist, and 86.2% for the radiologist and CAD combined [10]. The major limitations of the current CAD(e/x) systems are two fold, firstly the way the systems are trained and secondly the way the systems are used. The limitation of the training process is that the training samples might have had features associated with symptomatic lesions. In the actual usage environment the abnormalities might have less obvious mammographic features than symptomatic lesions. Consequently this might lead to false negative rate of up to 25% [6]. The limitation during the usage is that the thresholding, learnt by the CADe system during the training, may not be appropriate for the actual image data under consideration. Consequently most of the CAD prompts are false positive calls which leads to needless breast biopsies [8]. In the HCS based CAM system, designed in this study, the above issues were addressed as follows : The designed CAM system does not need any prior training. The designed system does not use a fixed thresholding to differentiate the abnormalities from the healthy tissue, rather it uses an adaptive measure adapted to the actual mammogram data being analysed. The rest of the paper is organized as follows. Firstly the operation of HCS process is outlined briefly. Secondly the methodology adopted to implement the designed CAM system, using the HCS process, is discussed. Then the performance of the designed CAM system in differentiating benign from malignant abnormalities is discussed. Finally the possibilities of using the designed CAM systems to aid radiologists is discussed. 2 Hierarchical Clustering based Segmentation The HCS process partitions an image into its constituent regions for a hierarchical levels of allowable dissimilarity between the different regions. As the allowable dissimilarity is incremented; at any particular level in the hierarchy, the HCS process clusters together all the pixels and/or regions that have dissimilarity among them less than or equal to the dissimilarity allowed for that level. At each level the HCS process yields an optimized segmentation output related to the dissimilarity allowed for that level. The algorithmic diagram, shown in Figure 1, illustrates the overall operation of HCS [3].

SELVAN, SAATCHI, FERRIS: Computer Aided Monitoring of Breast Abnormalities in X ray Mammograms Figure 1: Flow chart illustrating the working of the HCS process [3]. 3 Design and Implementation of the CAM System To start with it was hypothesised that in the X ray mammogram, the benign abnormalities will have image properties closer to the healthy tissue and malignant abnormalities will be markedly dissimilar from the surrounding healthy tissue. Hence the measured dissimilarity, between the region comprising the abnormality and the region comprising the healthy tissue, will indicate whether the abnormality is benign or not. To measure the dissimilarity between the abnormality and the healthy region the basic requirements are : appropriate delineation of the boundary of the abnormality identifying the region of the image comprising the healthy part. The process, how the above requirements are addressed, is explained below by an example Figure 2 shows a X ray mammogram (mdb102) of a dense glandular breast having a malignant asymmetry class of abnormality. Making use of the information provided in the mini MIAS database the approximate boundary of the abnormality (Green circle Figure 2 a), was located. The HCS process was applied within a ROI centred on the abnormality. Inspecting the HCS process output the user selected the region corresponding to the abnormality (Red Figures 2 b, c and d). The area within the approximate circular boundary, other than the abnormality, was selected as healthy, (Green Figure 2 d). Inspecting the HCS process output the user also selected a location, within the abnormal area, which was considered as the core of the abnormality (Yellow Figure 2 d and e). To estimate the dissimilarity between the abnormal and the healthy regions, the HCS process was applied only to the pixel locations within the abnormality (Red Figure 2 d and e) and the healthy (Green Figure 2 d and e) areas of the image. As the HCS process goes about merging similar regions within the abnormality and the healthy areas, the maximum average dissimilarity, measured between the cluster having the user tagged location (within the abnormality) and the clusters within the healthy region, is estimated. The heuristic used for differentiating malignant from benign abnormality is, if the value of the above estimated measure is less than fifty percent then the abnormality is benign else malignant. Graph shown in Figure 3 (a) demonstrates how the above measure and the criteria is able to classify the abnormality, under consideration, as malignant. Similarly the graph shown in Figure 3 (b) demonstrates how a benign abnormality is correctly classified.

4 SELVAN, SAATCHI, FERRIS: Computer Aided Monitoring of Breast Abnormalities in X ray Mammograms. b d c e a Figure 2: mini MIAS mammogram (Image ID mdb102) with the location and the approximate boundary of the abnormality circled in Red by the user (a).hcs process intermediate segmentation of four regions and their boundaries (b and c). Regions, and their boundaries, identified by the user as healthy (Green) and abnormal (Red) (d and e). a b Figure 3: For mini MIAS Mammogram images mdb102 and mdb097 graphs (a and b) showing the dissimilarity between the cluster having the user tagged location and other clusters belonging to the abnormality area and the healthy area. 4. Performance of the Designed CAM System For sixteen of the mini MIAS [5] cases the designed system successfully differentiated benign (B) from malignant (M) abnormalities. Table 1 lists the quantitative measures used. 5. Conclusion The designed CAM system, which does not need any prior training, can help the clinician to visualise and quantitatively measure dissimilarities between healthy and abnormal areas in X ray mammograms. Work is in progress to evaluate how the designed CAM system could augment the diagnostic capabilities of clinicians.

SELVAN, SAATCHI, FERRIS: Computer Aided Monitoring of Breast Abnormalities in X ray Mammograms Table 1 : Overall performance of the CAM system. Image ID Breast Tissue Type Class of Abnormality Severity of Abnormality Dissimilarity Measure CAM based Classification mdb002 mdb005 mdb012 mdb028 mdb075 mdb083 mdb090 mdb092 mdb095 mdb097 mdb099 mdb102 mdb104 mdb110 mdb141 mdb270 Glandular Glandular Glandular Glandular 16.08% 30.50% 40.50% 81.96% 52.81% 43.77 % 67.37 % 53.86% 61.48 % 48.79 % 48.18 % 65.72 % 32.43% 77.88% 82.64% 53.23% References [1] A. L. Elter M, Horsch A., CADx of mammographic masses and clustered microcalcifications: a review.medical Physics 2009 Jun;36(6):2052 68. 2009.. [2] Selvan, A.N.; Saatchi, R.; Amavasai, B.P.; Travis, J.R; "A Dissimilarity Visualisation System for CT: Pilot Study" The International Conference on Computer as a Tool. EUROCON 2005. Volume 2, Pages:1007 1010, 2005. [3] Selvan, A. N. "Highlighting Dissimilarity in Medical Images Using Hierarchical Clustering Based Segmentation (HCS)" M. Phil. dissertation, Faculty of Arts Computing Engineering and Sciences Sheffield Hallam Univ., Sheffield, UK, 2007. [4] Selvan, A.N.; Saatchi, R.; Ferris, C.M.; "Improving medical image perception by hierarchical clustering based segmentation" 9th International Conference on Information Technology and Application in Biomedicine, ITAB 2009. Pages:1 6, 2009. [5] Suckling, J. Parker, J. Dance, DR. Astley, S. Hutt, I. Boggis, C. Ricketts, I. Stamatakis, E. Cerneaz, N. Kok, SL. Taylor, P. Betal, D. and Savage, J. "The Mammographic Image Analysis Society Digital Mammogram Database" Exerpta Medica. International Congress Series 1069 pp375 378, 1994. [6] Bazzocchi M, Mazzarella F, Del Frate C, Girometti R, Zuiani C."CAD systems for mammography: a real opportunity? A review of the literature". Radiology Medicine;112(3):329 353. 2007 [7] Nishikawa RM. "Current status and future directions of computer aided diagnosis in mammography". Computer Med Imaging Graph;31(4 5):224 235. 2007 [8] Rossand G., Lorenzo C., Massimo B. and Chiara Z., "CAD comes under scrutiny in breast screening debate" Diagnostic Imaging Europe. Vol. 26 No. 7 October 29, 2010. [9] Ciatto S, Ambrogetti D, Bonardi R, Brancato B, Catarzi S, Risso G, Rosselli Del Turco M. "Comparison of two commercial systems for computer assisted detection (CAD) as an aid to interpreting screening mammograms." Radiology Medicine;107(5 6):480 488. 2004. [10] Ciatto S, Ambrogetti D, Collini G, Cruciani A, Ercolini E, Risso G, Rosselli Del Turco M. Computer aided detection (CAD) of cancers detected on double reading by one reader only. Breast;15(4):528 532. 2006