Microsoft Exchange 2010 /Outlook 2010 Performance with Riverbed WAN Optimization



Similar documents
Optimizing Microsoft Exchange Traffic over the WAN TECH BRIEF

Deploying Steelhead Appliances with Symantec Endpoint Protection 11.0

Riverbed WAN Acceleration for EMC Isilon Sync IQ Replication

Optimization of Citrix ICA with Steelhead Appliances and RiOS 6.0 WHITE PAPER

WAN Optimization. Riverbed Steelhead Appliances

The 3 Barriers to IT Infrastructure Consolidation

Evaluating the ROI of Riverbed Steelhead Products

Accelerating the Next Phase of Virtualization. Desktop virtualization and WAN optimization

Using Steelhead Appliances and Stingray Aptimizer to Accelerate Microsoft SharePoint WHITE PAPER

The CIO s Guide to Optimizing Virtual Desktops

Accelerating the Next Phase of Virtualization

Riverbed Granite Use Cases

Disaster Recovery with the Public Cloud and Whitewater Cloud Storage Gateways

WAN Optimization Benefits for Desktop Virtualization Customers

Understanding Flow and Packet Deduplication

McAfee Vulnerability Manager on RSP

借 助 广 域 网 优 化 技 术 实 现 高 性 能 数 据 大 集 中. 王 晓 静 Riverbed Technology Regional Sales Manager

Four Missing Components that Put Your Data Center Consolidation/Migration Project at Risk WHITE PAPER

How To Make A Cloud Work For You

IMPROVING PERFORMANCE FOR MOSTLY-LOCAL DISTRIBUTED APPLICATIONS

Branch Office Desktop

Federal Data Center Consolidation Playbook

Extreme Savings: Cutting Costs with Riverbed WHITE PAPER

Remote IT Infrastructure Consolidation

VMware Horizon Mirage Load Balancing

Granite Solution Guide

Deploying Microsoft SharePoint Services with Stingray Traffic Manager DEPLOYMENT GUIDE

Optimize Your Microsoft Infrastructure Leveraging Exinda s Unified Performance Management

Riverbed WAN Optimization Solutions

Manage, Secure, and Optimize the Performance and Availability of Business Services

The Riverbed Optimization System (RiOS)

5 Steps to Successful IT Consolidation and Virtualization WHITE PAPER

Riverbed Steelhead Product Family

RIVERBED STEELCENTRAL NETMAPPER

STEELHEAD PRODUCT FAMILY

PRODUCT BROCHURE. Riverbed Stingray Product Family

RIVERBED STEELCENTRAL NETPLANNER

Storage efficiency in WAN optimization solutions. Why it matters and what you need to know

FAQ RIVERBED WHITEWATER FREQUENTLY ASKED QUESTIONS

Riverbed vs. Juniper WXOS/JWOS

Chris Pinckney, CIO, Psomas

Making a Case for Including WAN Optimization in your Global SharePoint Deployment

Steelhead Product Family

Optimizing Thin-client Traffic over the WAN

Accelerate Private Clouds with an Optimized Network

A CIO s Guide to Hybrid Cloud Performance

Virtual Cascade Shark

How To Create A Qos

Steelhead Product Family

Optimizing NetApp SnapMirror

Optimizing Thin-client Traffic over the WAN WHITE PAPER

An In-Depth Look at ROI

Optimizing Performance for Voice over IP and UDP Traffic

Riverbed. Steelhead Product Family

The CIO s new guide to design of global IT infrastructure

Riverbed Stingray Traffic Manager VA Performance on vsphere 4 WHITE PAPER

Stingray Traffic Manager Sizing Guide

Cisco WAAS Express. Product Overview. Cisco WAAS Express Benefits. The Cisco WAAS Express Advantage

CISCO WIDE AREA APPLICATION SERVICES (WAAS) OPTIMIZATIONS FOR EMC AVAMAR

Data Storage in the Cloud Can you Afford Not To? WHITE PAPER

Extreme Savings: Cutting Costs with Wide-Area Data Services

The CIO s New Guide to Design of Global IT Infrastructure

Strategies to Speed Collaboration and Data Management Using Autodesk Vault and Riverbed WAN Optimization Technology

Deploying Riverbed wide-area data services in a LeftHand iscsi SAN Remote Disaster Recovery Solution

SDC The Service Delivery Controller FACT SHEET

Lab Testing Summary Report

Important Considerations for Cisco WAAS in Large-Scale Enterprise Deployments

The Riverbed Performance Platform

Riverbed SaaS. 04 de Setembro de Copyright 2015 Data Systems, todos os direitos reservados.

Deploying Riverbed Cascade and Steelheads. A Best Practices Whitepaper

DATA SHEET. Riverbed Cascade Shark Family

Accelerating WAN Performance with Riverbed

Centralized Data Backup

An Optimal Opportunity. Mobile and Remote Working in Central and Local Government

Granite Data Protection and Recovery Guide

Features. Key benefits. HDX WAN optimization. QoS

Riverbed Stingray Traffic Manager PRODUCT BROCHURE

Cisco WAAS Optimized for Citrix XenDesktop

Integration Guide. EMC Data Domain and Silver Peak VXOA Integration Guide

Clouds, Performance Platforms, and Agility Mark Stuart Day Riverbed Technology

The CIO s new guide to design of global IT infrastructure

Optimize Application Delivery for Global Deployment Of SAP BusinessObjects Enterprise with Blue Coat Systems Acceleration

Bill Ting, Product Marketing Riverbed Technology

WHITE PAPER. Riverbed SteelFusion. Extending storage across the WAN for complete edge consolidation

SteelFusion with Amazon Web Services Storage Gateway Solution Guide

WAN Optimization Integrated with Cisco Branch Office Routers Improves Application Performance and Lowers TCO

AKAMAI AND RIVERBED JOINTLY DEVELOP INNOVATIVE SAAS ACCELERATION SOLUTION

WAN Optimization and Cloud Computing. Josh Tseng, Riverbed

Building a better branch office.

Cisco and EMC Solutions for Application Acceleration and Branch Office Infrastructure Consolidation

Lab Testing Summary Report

Disaster Recovery White Paper: Reducing the Bandwidth to Keep Remote Sites Constantly Up-to-date

WAN OPTIMIZATION FOR MICROSOFT SHAREPOINT BPOS

Data Storage in the Cloud Can you Afford Not To? WHITE PAPER

Windows Server on WAAS: Reduce Branch-Office Cost and Complexity with WAN Optimization and Secure, Reliable Local IT Services

WAN Optimization for Microsoft SharePoint BPOS >

Cisco Wide Area Application Services Optimizes Application Delivery from the Cloud

Riverbed SteelHead. Product Family Brochure

RIVERBED EXTENDS FROM WAN OPTIMIZATION TO EDGE VIRTUAL SERVER INFRASTRUCTURE (EDGE-VSI)

How To Use The Cisco Wide Area Application Services (Waas) Network Module

Transcription:

Microsoft Exchange 2010 /Outlook 2010 Performance with Riverbed WAN Optimization A Riverbed whitepaper Riverbed participated in an early Microsoft TAP program to validate interoperability for Exchange 2010 SP1 with successful test results outlined in this paper. Microsoft worked closely with Riverbed to streamline the application performance, mitigate latency and optimize the effectiveness of Exchange 2010 over the WAN*.

Introduction Microsoft Exchange Server 2010, the cornerstone of the Microsoft Unified Communications solution, has long been the choice of organizations to enable rich and productive collaboration among its users. It has become the corporate standard in email, calendaring, and workforce productivity. As a result, significant time and IT resources go into creating a robust, reliable, high-performance Exchange environment. IT departments regularly consider deploying additional exchange servers, moving servers to branch offices, and even adding more bandwidth in order to improve Exchange performance. To alleviate this need and provide IT departments with the benefit of Exchange consolidation combined with improved performance, Riverbed Steelhead appliances offer application acceleration for MS Exchange Server Outlook traffic, delivering LAN-like performance to distributed Outlook users. Riverbed Technology enhances and extends Microsoft Exchange implementations Riverbed significantly optimizes Microsoft Exchange traffic to deliver superior performance for remote offices by utilizing the Riverbed Optimization System (RiOS), which simultaneously addresses bandwidth constraints and the combined effects of latency and protocol inefficiencies. RiOS uses fine-grain data reduction, as well as compression, to perform Data Streamlining, typically reducing bandwidth utilization by 60% to 99%,Transport and Application Streamlining minimize protocol chattiness, eliminating 65 to 99% of packet round trips across the WAN. RiOS also utilizes specialized Application Streamlining for MAPI, which enables significant performance improvements for Outlook clients for sending/receiving email, including encrypted mail and those with attachments. With RiOS, distributed Exchange servers and complex replication models are no longer necessary for accelerated performance to any office, anywhere in the world. Ultimately, this paper will present the Riverbed Steelhead appliance as a solution to the WAN performance obstacles Exchange/Outlook users may experience. Customers want to mitigate the effects of Latency and Bandwidth experienced by distributed Outlook clients to: Boost the performance of email send/receive operations in distributed environments Eliminate network connection congestion due to lower bandwidth Significantly reduce or minimize chattiness of the MAPI protocol Preserve secure, encrypted message exchange while increasing performance Consolidate Exchange servers at the data-center Riverbed and Microsoft Exchange Test Summary Testing was performed in conjunction with the Microsoft Exchange performance team. The test configuration simulated a typical Outlook client scenario accessing the Microsoft Exchange server in a distributed enterprise. The simulated client was at a remote office accessing a centralized Microsoft Exchange 2010 server over 1544kbps WAN bandwidth with 100ms latency (round trip time). See logical diagram in Figure 1 below. * - Greg Smiley, Senior PM, Exchange Team, Microsoft Corporation 2010 Riverbed Technology. All rights reserved. 1

Riverbed Steelhead (SSL enabled) 192.168.0.11 Simulated T1/ 100ms latency WAN Riverbed Steelhead (SSL enabled) 192.168.0.18 Distributed MS Outlook Clients Client 1: 192.168.0.9 Client 2: 192.168.0.10 192.168.0.20 Figure 1: Test setup Tests were performed using Outlook 2010 clients running on Windows 7 Enterprise platforms, connecting to an Exchange 2010 Server running on Windows 2008 R2. The testing included common activities such as sending and receiving email, both encrypted and unencrypted, with a combination of file attachment sizes. The performance tests were run on T1 WAN links with a latency of 100ms. Refer to the Steelhead Management Console User s Guide for encrypted MAPI configuration settings on the Steelhead appliances. Terminology A cold operation is defined as a data transfer that has never been seen by the Steelhead appliance before (completely new data). A warm operation is defined as a data transfer in which the Steelhead appliance has seen most or all of the data before (warm performance is also observed with an incremental change of data that has been used by another application across the WAN). Test Results The table below highlights a sample of the Exchange 2010 performance improvement and bandwidth reduction observed, with Steelhead appliances in the network. Graphs are also included for clarity. Testing showed Exchange 2010 performance improvements of the order of 34x for email send operations. Also bandwidth usage was reduced by up to 99% with the Steelhead appliance. 2010 Riverbed Technology. All rights reserved. 2

MS Exchange 2010 Test Description Send email (clear-text) with 6.3MB.ppt attachment Send email (encrypted) with 6.3MB.ppt attachment Send email (encrypted) with 6.3MB attachment to multiple recipients Time without Steelhead (seconds) Time with Steelhead () Time with Steelhead () Performance Improvement 135 30 4 34x 140 42 6 23x 144 60 18 8x Table 1: Performance Improvement results for Exchange 2010 with Riverbed Steelhead MS Exchange 2010 Test Description Bytes transferred without Steelhead Bytes transferred with Steelhead (cold) Bytes transferred with Steelhead (warm) Bandwidth Reductrion Send encrypted 6.3MB attachment Send email 6.3MB attachment to multiple recipients 12279054 4306155 107707 99% 12272218 8426731 345177 97% Table 2: Bandwidth Reduction results for Exchange 2010 file with Riverbed Steelhead Send email (clear-text) with 6.3MB attachment Performance Improvement 0.00 20.00 40.00 60.00 80.00 100.00 120.00 140.00 160.00 Time to complete (s) Encrypted email send with 6.3MB attachment to multiple recipients Performance Improvement 2010 Riverbed Technology. All rights reserved. 3

0 20 40 60 80 100 120 140 160 180 Time to complete (s) Encrypted MAPI Send email with 6.3MB attachment Bandwidth Reduction 0 2000000 4000000 6000000 8000000 10000000 12000000 14000000 bytes transferred over WAN Encypted email with attachment to multiple recipients Bandwidth Reduction 0 2000000 4000000 6000000 8000000 10000000 12000000 14000000 2010 Riverbed Technology. All rights reserved. 4

Riverbed WAN Optimization Results Highlights RIVERBED DEPLOYMENT BENEFITS! Outlook/Exchange operations are up to 34 times faster! Bandwidth utilization is reduced by up to 99% Deploying Riverbed with Microsoft Exchange provides multiple benefits, including: Improved productivity. Microsoft Exchange over the WAN can now be significantly accelerated. By dramatically reducing the time needed to complete the most typical operations, users can save valuable time each day.! Steelheads Powered by the Riverbed Optimization System (RiOS) RiOS software combines patent-pending data reduction, TCP optimization, application-level latency optimizations, and remote office file and management functionality. Together, these technologies provide a comprehensive solution for enterprise wide-area data services, scaling across a range of applications and network topologies to accelerate applications up to 100x. RiOS consists of four key components: Data Streamlining!"!RiOS Data Streamlining works across all TCP applications to reduce bandwidth consumption by up to 99%. Data Streamlining works across Windows file sharing (including MS Office), Email (including MS Exchange and Lotus Notes), CAD, ERP, databases, and all other applications that use TCP, to ensure the same data is never sent more than once over the WAN. Data Streamlining also supports rules-based policy administration of optimization classes and packet marking for QoS and route control. Faster, more efficient collaboration. Teams at distributed locations are now able to collaborate more fluidly by taking advantage of the accelerated email retrieval speeds.! Reduced bandwidth utilization. Steelhead appliances significantly reduce bandwidth utilization for remote offices accessing an Exchange Server over the WAN, thus enabling more effective use of existing bandwidth.! Simpler Exchange deployment. Steelhead appliances enable accelerated performance to remote offices from a central Exchange server. Multiple Exchange instances and complex replication models can be consolidated to the data center without compromising performance to even the most remote branch.! Transport Streamlining!"!RiOS Transport Streamlining reduces the number of TCP packets required to transfer data by up to 98%. Transport Streamlining overcomes TCP limitations by adapting transmission characteristics such as window scale, loss handling, congestion notification, and more. RiOS Transport Streamlining also enables greater utilization of high bandwidth, high latency connections with High-Speed TCP capabilities. Application Streamlining!"!RiOS Application Streamlining provides additional order-of-magnitude application performance improvements by reducing application protocol chattiness up to 98% and minimizing application overhead. By minimizing application demands on the network such as application protocol round trips and required network connections, RiOS can provide massive throughput increases to applications including Windows file sharing (CIFS), Exchange (MAPI), Web (HTTP), and Database (MS-SQL). RiOS also includes important features for maximizing branch office productivity, such as file server capabilities and transparent pre-population of popular data. Management Streamlining!"!RiOS simplifies the deployment and management of application acceleration infrastructure by employing a transparent approach to communications. RiOS enables easy deployment through autodiscovery of peers and auto-interception of traffic, with no reconfiguration of clients, servers, or routers necessary. RiOS simplifies ongoing management by providing simple but powerful Web-based and command line interfaces and reporting, as well as the integrated, centralized management and configuration. RiOS also enables a host of additional management features including dozens of deployment configurations, capabilities for redundancy, optional IPsec encryption, RADIUS/TACACS+ authentication, and SNMP traps.! 2010 Riverbed Technology. All rights reserved. 5

Conclusion By optimizing the performance of Microsoft Exchange over the network, users can defer upgrading bandwidth to support Exchange processes and may also be able to leverage a smaller and less expensive network connection. Depending on the distances involved, this could result in significant savings. Riverbed also can help maintain a centralized Exchange deployment model which can effectively service distributed workers. This can result in reduced IT maintenance costs. Riverbed WAN optimization solutions enable enterprises to maximize the benefits of Exchange across a distributed environment by providing a very positive and productive user experience, when accessing an Exchange server over a WAN. About Riverbed Riverbed Technology is the IT performance company. The Riverbed family of wide area network (WAN) optimization solutions liberates businesses from common IT constraints by increasing application performance, enabling consolidation, and providing enterprise-wide network and application visibility all while eliminating the need to increase bandwidth, storage or servers. Thousands of companies with distributed operations use Riverbed to make their IT infrastructure faster, less expensive and more responsive. Additional information about Riverbed (NASDAQ: RVBD) is available at www.riverbed.com Riverbed Technology, Inc. 199 Fremont Street San Francisco, CA 94105 Tel: (415) 247-8800 www.riverbed.com Riverbed Technology Ltd. Farley Hall, London Rd., Level 2 Binfield Bracknell. Berks RG42 4EU Tel: +44 1344 354910 Riverbed Technology Pte. Ltd. 391A Orchard Road #22-06/10 Ngee Ann City Tower A Singapore 238873 Tel: +65 6508-7400 Riverbed Technology K.K. Shiba-Koen Plaza, Bldg. 9F 3-6-9, Shiba, Minato-ku Tokyo, Japan 105-0014 Tel: +81 3 5419 1990 2010 Riverbed Technology. 199 Fremont Street, San Francisco, CA 94105 USA. All rights reserved. Riverbed Technology, Riverbed, Steelhead, RiOS, Interceptor, Think Fast, the Riverbed logo, Mazu, Profiler, Atlas, Cascade, Virtual Steelhead, and Cloud Steelhead are trademarks or registered trademarks of Riverbed Technology All other trademarks used or mentioned herein belong to their respective owners. SB-XX042409 2010 Riverbed Technology. All rights reserved. 6