Vacuum Piping. RAMVAC Recommendations and Limitations



Similar documents
SECTION FACILITY STORM DRAINAGE PIPING

DRAIN, WASTE AND VENT PLUMBING

Residential Plumbing

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector

Top 10+ Mistakes of DWV plumbing design

CHAPTER 11 STORM DRAINAGE

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

Chapter 7 Plumbing Connections

CHAPTER 11 STORM DRAINAGE

When Should Examination Preparation Begin?

Installation & Operation

SUMP PUMP. City of Ann Arbor & C O L L E C T I O N S Y S T E M G L O S S A R Y

SERVICE LINE EXTENSION AND SERVICE LINE CONNECTION CONDENSED SANITARY SEWER SYSTEM INSTALLATION SPECIFICATIONS

CHAPTER 9 VENTS. copper drainage tube Type DWV, Schedule 40 plastic piping, or borosilicate glass.

Why Do I Have Sewer Smells In My Home or Business?

Element D Services Plumbing

Understanding and Designing Plumbing Systems

SIERRA LAKES COUNTY WATER DISTRICT P.O. Box 1039, Soda Springs, CA (7300 Short Road, Serene Lakes)

2010 Residential Water Heater Replacement Check List

To many people, a home s plumbing system is perceived as being extremely

3. Contractor shall ensure that all permits are obtained prior to any construction. Contractor shall be responsible for all utility fees.

Hanna delivers the technical and marketing expertise needed to produce a car wash that meets the car wash customer's expectations.

Wastewater Collection System Supplemental Design Standards for Capital Improvement Program Projects

Town House Center Highway North Huntingdon, PA 15642

DIVISION OF WATER QUALITY CONSTRUCTION GRANTS & LOANS SECTION FAST TRACK AUDIT CHECKLIST

SANITARY SEWER BACKUP. Causes & Prevention

Residential Plumbing BCN 1058

Jay R. Smith Mfg. Co.

Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

ARTICLE II (2) ARTICLE II - REQUIRED USE OF PUBLIC SEWERS. PARAGRAPH Purpose and Application.

Plumbing Code in Commercial Kitchens

SECTION 5: SANITARY SEWER SYSTEM DESIGN

HS-901(A) BASIC STEAM HEATING SYSTEMS

CHAPTER 10 TRAPS, CLEAN-OUTS, AND INTERCEPTORS

2006 Codes. Please verify the following before calling for inspection

CITY OF SELMA, TEXAS Inspection Checklist: Commercial

The checklist utilized by the Authority will be similar to that which is shown below. Project Name: Location: Consulting Engineering Firm:

Facility Operations Physical Safety Guidance Document

Sewage Compliance Form Instructions

Homeowner s Guide Foundation Water PenetrationTips TIPS TO IDENTIFY WATER PENETRATION PROBLEMS / CRACKING BASEMENTS

What to Expect From the Examination. How to Study the Plumbing Codes

Land Use and Environmental Service Agency (Code Enforcement) NC Plumbing Code. Table of Contents

INSPECTION CHECKLIST Residential Plumbing Rough In April 2011 Mercer Island Mill Creek Sammamish Snohomish County Snoqualmie Woodinville

Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing

Fiberstars Lighted Laminar Flow Fountain Installation Manual

CONSTRUCTION CHECKLIST Residential Plumbing Rough-In September 2004

PMA ONLINE TRAINING Venting for Plumbing Systems

NOBLE. MODIFYING SPOT SPRAYERS for Broadcast Pasture/Lawn Use. Authors: Eddie Funderburg, Jeff Ball, Jim Johnson and David Annis NF-SO-04-01

CHAPTER 9 VENTS TRANSPORTATION OF SEWER GAS

Specifications for Residential Property Owners Connection to New Public Sewer

Industrial Strength Rocket Launcher

Most agencies think about cleaning because of debris in the line.

Mandatory Part 1.4 BUILD OVER OR NEAR SEWERS, STORMWATER DRAINS AND WATER MAINS

Does Part of My Basement Floor Have to Be Removed to Install. Where Does the Water from the Sump Pump Go?...Page 5

Reticulation sewers in basements Technical guidelines

SANITARY SEWER SPECIFICATIONS

INSTRUCTION MANUAL A REVISION A. Series E1 and E3 Instant Hot Water Recirculating Systems

All work shall comply with applicable codes and ordinances. Work shall comply with the BOCA National Plumbing Code, latest edition.

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

12. Design of plumbing systems for single dwellings

FY11 Sanitary Sewer Main Rehab and Point Repair Bid Tabulation

Freezer Floor Heaving and Solution

Requirements for Building Application Submission

Triple Point Experiment

FY08 SEWER POINT REPAIRS BID TABULATION

PART 6: VENTING, COMBUSTION AIR & CONDENSATE REMOVAL

SEPTIC SYSTEM CONSTRUCTION REQUIREMENTS ST. MARY S COUNTY HEALTH DEPARTMENT

SEWER BACK UP PREVENTION PILOT PROGRAM

CHAPTER 11 STORM DRAINAGE

Mobile Home Pre-Inspection Checklist

Louisiana Administrative Code Title 51 Part XIII. Sewage Disposal

INSTALLATION INSTRUCTIONS GEO-BOOSTER TM

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

Constructing Cistern Installations

Fiberstars Mini Lighted Laminar Flow Fountains

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

Repair and Disinfection of Water Mains Water Protection Program fact sheet

HOW A SEPTIC SYSTEM FUNCTIONS

16. Storm water drainage

How To Install An Overhead Sewer

INTERCEPTORS TABLE OF CONTENTS S-WD-INTER

EFFECTIVE FEBRUARY note: drainage permit required to call for a dampproof inspection

ATTENTION This is a general warning that failure to follow instructions could result in poor functioning of the unit.

State of Connecticut Department of Public Health RADON PROGRAM

Module 7. Plumber: Sink Installation

SECTION 3 SANITARY SEWER DESIGN

Protect Your Home From Flooding. A guide for Lethbridge Residents

Please also see 10 golden rules for correct Saniflo installation on

15430 SAFETY SHOWERS AND EYEWASHES

EXCAVATION AND PILING NEAR SEWERS, STORMWATER DRAINS AND WATER MAINS

Pressure Vessels (Air Compressors) and LPG Tanks

Amendments to the 2012 International Plumbing Code

Protect your home from basement flooding

SUMP PUMP DISCHARGES INFORMATIONAL PACKET

Plumbing Code in Commercial Kitchens. NH BOA May 9, 2012

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

SECTION ABANDONMENT OF SEWER MAINS

HELIPORT FUEL/WATER SEPARATOR MODEL H-200

Brian Coppock, Regional Compliance Officer. Office of Statewide Health Planning and Development Facilities Development Division

Transcription:

Vacuum Piping RAMVAC Recommendations and Limitations RAMVAC makes recommendations for piping dental vacuum system in the attempt to insure predictable performance and avoid disappointing surprises. There are limitations in insuring predictable performance. The following information states limitations of RAMVAC recommendations and points out conditions that may affect the appropriateness of recommendations. ailure to read, understand and properly apply our recommendations can lead to disappointments. What RAMVAC recommendations represent: 1. Expertise in understanding the uses of vacuum in dental treatment 2. Expertise in understanding the required flow (in SCM) and lifting power (in inches Hg) for acceptable dental vacuum performance 3. Expertise in understanding the limitations in flow and lifting power that can be introduced by: Common dental treatment room (DTR) vacuum components Common facility piping components Length and diameter of piping 4. Expertise in understanding the flow of liquids and gases in dental vacuum piping systems Limitations of RAMVAC recommendations: 5. RAMVAC does not have expertise in building construction, nor does it have specific detailed information about a specific building's construction; and, therefore cannot provide recommendations for specific pipe and fitting locations. 6. RAMVAC cannot be familiar will all local codes and requirements. Conditions that affect the appropriateness of RAMVAC recommendations: 1. Performance requirements details, piping details and DTR details not disclosed by the owner/contractor 2. ailure of the owner/contractor to follow written RAMVAC recommendations 3. ailure of the owner/contractor to follow standard plumbing practices 4. ailure of the owner/contractor to request clarification for any RAMVAC recommendation not completely understood or appearing questionable eneral Principles for Vacuum Lines 1. Construct vacuum lines as drain lines: Slope a minimum of 1/4" in 10 feet with low end at tank. Use drain, waste & vent (DWV) fittings. 2. f an in-line low spot is unavoidable, place it in a known location and incorporate a clean out. 3. or overhead runs, contact RAMVAC. 4. or nitrous oxide scavenging, contact RAMVAC. 5. All work must comply with 2005 NPA 99c. Refer to RAMVAC Tech Sheet NPA-2005 Edition-Level 3 Vacuum. Notes on RAMVAC Piping Recommendations 1. RAMVAC drawings may not be to scale. 2. Vacuum lines are shown on RAMVAC drawings for general location only. Please contact RAMVAC Technical Support if you have any questions. 3100 irst Avenue ax (605) 642-3776 SO_7.2.3-01-004.doc Page 1 of 8 Pages

Vacuum Piping Piping Alternatives Piping from treatment room vacuum equipment to dental vacuum source equipment can be run in three alternatives configurations, or combinations thereof: 1. Below grade 2. At or slightly above floor level 3. Overhead As with other decisions, the best alternative is often a best compromise of qualities. Below rade At or slightly above floor level Overhead Advantages ood esthetics -- out of sight Low cost if a concrete floor is not already in place Often least expensive Easiest to execute ood esthetics -- out of sight Can be accomplished even with an in place concrete floor Disadvantages Expensive if a concrete floor is already in place uture access may be limited Poor esthetics -- pipe visible Not appropriate for traffic areas (doorways) Disastrous if not executed correctly Often more expensive May require extra strong vacuum producers Access may not be available May require stronger vacuum than operators prefer Requires operator compliance (air must follow liquids) Other Considerations Pipe Size Minimum 2" for any plumbing poured in concrete Dependent on system size; see RAMVAC plumbing recommendations Dependent on system size; see RAMVAC plumbing recommendations See RAMVAC recommendations for essential details Slope Low Spots Minimum ¼" per 10 foot of horizontal run Place in known location and incorporate clean-out Nitrous Oxide (N 2O) Scavenging Must connect to vacuum line separately from chair/unit vacuum Must connect to vacuum line separately from chair/unit vacuum See RAMVAC recommendations for essential details 3100 irst Avenue ax (605) 642-3776 SO_7.2.3-01-004.doc Page 2 of 8 Pages

Vacuum Piping Below rade Vacuum Piping To Treatment Room Junction Box See Treatment Room Termination for more details. 1 ½ DWV 90 Elbow 2 DWV 90 Elbow Branch Line to Treatment Rooms 1 ½ PVC schedule 40 2 PVC DWV sanitary tee Main Vacuum Line To Vacuum Separating Tank Slope a minimum of ¼ in 10 feet with low end towards tank Use drain, waste and vent (DWV) fittings f an inline low spot is unavoidable, place it in a known location and incorporate a clean-out or nitrous oxide scavenging, contact RAMVAC. All work must comply with 2005 NPA 99c Place piping in larger size conduit to reduce chance of damage from shifting concrete. 3100 irst Avenue ax (605) 642-3776 SO_7.2.3-01-004.doc Page 3 of 8 Pages

Vacuum Line Dental Treatment Room Termination - loor Mount Junction Box Surface Mount Junction Box Surface Mount Junction Box A B C lush Mount Junction Box A B C D E E J J H A 5/8" Hose x 3/4" mpt 90 Elbow C 3/4" fpt x 1½" mp t PVC Bushing 1½" sch 40 PVC Pipe 2" sch 40 PVC Pipe B 5/8 Hose x 3/4" mpt Straight D 1½"fpt x 2" PVC lush Bushing 1½" PVC emale Adapter J 2" PVC DWV Sanitary Tee E 1½" x 2" PVC lush Bushing H 2" PVC DWV 90 Elbow 3100 irst Avenue ax (605) 642-3776 SO_7.2.3-01-004.doc Page 4 of 8 Pages

Vacuum Line Dental Treatment Room Termination - Wall Mount Junction Box Wall Mount Junction Box A E A 5/8" Hose x 3/4" mpt 90 Elbow C D B C 5/8 Hose x 3/4" mpt Straight 3/4" fpt x 1½" mpt PVC Bushing D 1½" fpt x 1½" PVC lush Bushing E 1½" PVC DWV 90 Elbow 1½" sch 40 PVC Pipe 1½" PVC emale Adapter H 2" PVC DWV 90 Elbow 2" sch 40 PVC Pipe J 2" PVC DWV Sanitary Tee H J 3100 irst Avenue ax (605) 642-3776 SO_7.2.3-01-004.doc Page 5 of 8 Pages

Overhead Piping Ask about running dental vacuum lines overhead and you'll get comments ranging from "reat idea. Saved me a ton of money" to "Whata disaster. 'll never do it again." or proper operation, all vacuum systems are dependent on proper plumbing and pump sizing. f you make an error in plumbing or pump sizing a system with below grade piping system, vacuum might be weak and operators might grumble. f you make an error in plumbing or pump sizing a system with overhead piping, the consequences are more serious: vacuum may be non-existent and operators can't work -- at all. n short, using overhead piping is like flying an airplane. You've got a demanding tool with unique capabilities. Use it wrong and Mother Nature, with all the subtleness of a locomotive hitting a toy boat, informs you that you've disobeyed the rules. Errors with overhead plumbing are about as subtle as a crash landing. Plumbing Rules for Overhead Piping: Keep the vertical lift height as short as possible. The vertical pipe must tee into the top of the horizontal line. Run the vertical line in 1/2" pipe. Run the horizontal overhead line in 1-1/2" or (preferably) 2" size pipe. or more than 5 treatment rooms, consult with RAMVAC. Nitrous oxide scavengers must run in a separate vertical pipe and tee into the top of the horizontal line in a separate location from the "wet" vertical pipe. Pump Sizing Rules for Overhead Piping: The vertical lift height must be less than the system's water lifting strength when the required number of vacuum devices are in use. The end user must accurately state the number and type of vacuum devices required to be served simultaneously and continuously. See vacuum use definitions and values in RAMVAC equipment sizing documents. Operator Rules for Overhead Piping: Operators must allow air to follow liquids before closing vacuum valves. Operators must be prepared to work with stronger than "normal" vacuum. 3100 irst Avenue ax (605) 642-3776 SO_7.2.3-01-004.doc Page 6 of 8 Pages

Overhead Piping Vertical pipes must tee into top of horizontal overhead pipe. eneral Principles for Vacuum Lines Slope a minimum of 1/4" in 10 feet with low end towards tank Use "drain, waste and vent" (DWV) fittings. f an in-line low spot is unavoidable, place it in a known location and incorporate a clean-out. or nitrous oxide scavenging, contact RAMVAC. All work must comply with 2005 NPA 99c. 3100 irst Avenue ax (605) 642-3776 SO_7.2.3-01-004.doc Page 7 of 8 Pages

Vacuum Line Low Point The vacuum line low point is a likely site in a dental vacuum line for a clog. nsure access to this vulnerable point by placing the piping low point in a well with a know location. Make the well large enough so that the 90 elbow (the Low Spot elbow) that turns the flow upwards can be removed if necessary. Plan for removal by selecting either method shown below. loor To Separating Tank To Separating Tank Well Well rom Treatment Rooms rom Treatment Rooms Low Spot Slip Union Low Spot Cut and Splice Method Slip-Union Method 3. Construct well large enough to access the pipe from the Treatment rooms so that it can be cut close to the Low Spot elbow. 4. f a Low Spot elbow clog occurs, cut the pipe and remove the elbow. 5. Attach a replacement elbow using a No-Hub connector. 6. Construct well large enough to access the pipe from the Treatment rooms and a Slip Union connecting it to the Low Spot elbow. 7. f a Low Spot elbow clog occurs, detach the Slip Union and clean the elbow. 8. Reattach the clean elbow with the Slip Union. 3100 irst Avenue ax (605) 642-3776 SO_7.2.3-01-004.doc Page 8 of 8 Pages