Product description Pump TM1 electrical. Discharge : 11 0,2 cm 3 8,5 0,4 cm 3 5,5 0,6 cm 3 3 0,8 cm 3 0 1,0 cm 3



Similar documents
MANTA Piston Distributor for Oil and Fluid Grease

Hydraulic Trouble Shooting

SINGLE LINE CRENTRALIZED LUBRICATION SYSTEM

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT

Rexroth Hydraulic Pump A10VO Series User Manual

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

T-Series Precision Linear Actuators Installation and Service Manual DW110353GB EDITION 5.

Machine needle shut-off nozzle type-a

CYMAQ Marking System AS200 + DS7050 N-14

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Error Codes: 02F. Model: (110. = Whirlpool) S/N: CSP Type: 199-AKP 705/WT. Sears Kenmore/Whirlpool Front Load Washer

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

PRODUCT MANUAL - M090

This instruction is valid for all ACD pump models shown on page 2

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

ECOCIAT. Domestic hot water heat recovery unit

POSITIVE DISPLACEMENT FLOWMETER - IM012P (PULSE)

TECHNICAL INFORMATION

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

System Saver 318 Air Compressor for Mack E-Tech and ASET Engines

Operating Instructions Hand pallet trucks HU Profi. Issue

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

Diesel Engine Driven Generators Page 1 of 6

Model 1210C Battery Powered Pump Shown. Description

The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron.

Operating instructions Pump FZ-A

Steering Gear Manual

HYDRAULIC LIFT TABLE CART 2200-LB.

Oil and Coolant Circulating Heating System. Model - OCSM

Heavy Fuel Oil supply units. The world s best selling HFO supply unit. The right choice for any conditions

Class 5 to 7 Truck and Bus Hydraulic Brake System

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850

PVH131/141 Variable Displacement Piston Pump - 11 Design

Flex separation systems, S-separators

Single-Phase AC Synchronous Generator

Maintenance and Operating Instructions SIS 120P/SISF

EQUALIZER International Limited Range of Mechanical & Hydraulic Flange Spreading Wedges Operator Instruction Manual. B bestflangespreader

PUMP AND MOTOR DIVISION

In addition, a number of auxiliary options are available (para 2.7) as well as optional slices for special requirements (para 2.8).

Technical Guide 08/15/14

GIANT POPCORN MACHINE SERVICE MANUAL

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

Pallet Jack. OWNER S MANUAL Model MH1230. Important Safety Instructions Assembly Instructions Parts and Hardware Identification

User's Guide. Digital Viscotesters. Model High Range (0.3 to 4000 dpas) Model Low Range (1.5 to 330 mpas) Introduction

Davcron Concrete Agitator - Operations Manual

Table Z. Troubleshooting Chart for Air Conditioners. Cause

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

15/40/80CN Series Medium Pressure Filters

The cylinder head bolts tightening stages have been updated as listed in Table 1.

Oregon Fuel Injection

Current state of plant Functioning as a peak and emergency centre. Statistics Accumulated operating hours:

Installation & Maintenance Manual. Type D MKII Straight Line Wiper. With Pneumatic Motor

Chapter 7 Hydraulic System Troubleshooting

1000-LB. TRAILER JACK OWNER S MANUAL

CPS-3 Pallet Jack Scale

Pressure calibration equipment

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

SOLENOID VALVES AND PNEUMATIC VALVES

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

Operating instructions Mechatronic flow sensor. SBY33x /06 03/2011

Kobelco Extended Warranty Program.

Return line filters. Return line filters

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

GROENEVELD AUTOMATIC GREASING SYSTEMS

SET-UP AND INSTALLATION FOR LEAD SCREW CARTRIDGE ASSEMBLY

INSTRUCTIONS FOR USE SAFETY PRINCIPLES, OPERATION AND MAINTENANCE FOR. HYDRAULIC PUMP type HP 03L, 05L, 07L volume 3 l, 5 l, 7 l

PANCAKE CAPACITOR GENERATOR Installation, Operation and Maintenance Manual

Pressure Relief Valves SPV, SPVF

Delta Power Company 4484 Boeing Drive - Rockford, IL 61109

Hydraulic multidisc Brake H420

PVS 185, 600, 1200, 1800, 2700 Series Portable Purification Systems

PUMP MAINTENANCE SCHEDULE AND CHECKLISTS

PORTABLE AIR CONDITIONER

INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS

HOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800) Internet Address:

INSTRUCTION. Industrial Sewing Machines. No First published : June 1997 Second edition : March 2001

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

, User s Manual

ELECTRIC BICYCLE OWNER S MANUAL

Adams. Spray Lubrication

INSTALLATION INSTRUCTIONS FOR VW MK5

Industrial Hydraulic Remote Controlled Monitor

Please also see 10 golden rules for correct Saniflo installation on

Hydraulic Air Riveter. Operation Manual RC197 RC198. Recommend for mass production line industrial area. Page 1

Presented by Rory S. McLaren. SAFE by DESIGN

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

Fish Grader User Manual

OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd

Q&A Session for Advanced Ball Screws 102: Troubleshooting for Design Engineers

Suction assembly for l IBC and 205 l drums mm suction tube Suction assembly for tanks mm suction tube.

- Do not immerse cords, pump or any electrical wire or device in water or other liquid.

Operating Manual. Los Angeles Abrasion Machine HM-70A & HM-70AF

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Cooling system components, removing and installing

Transcription:

Product description Pump TM1 electrical DESCRIPTION The TM1 pump has a wild field of applications but is particularly suited to small machines with no more than about 20 lubrication points (see technical information). The TM1 pump is interchangeable with the manual XL5P, giving customers the ability to change esaily from a manual to an automatic system or vice versa. OPERATION The TM1 is an automatic driven piston pump with a spring discharge. The motor assembly determines the discharge cycle time (see table below) of the piston wich distributes oil through the system. TM1 pump is equipped with an electrical low level switch. X Discharge 11 0,2 cm 3 8,5 0,4 cm 3 5,5 0,6 cm 3 3 0,8 cm 3 0 1,0 cm 3 System outline TECHNICAL DATA Discharge : Settings (see drawing) : Pressure : Motor : Electrical low level switch : Filter : Reservoir capacity : System limits : Lubricants to be used : 0.2 to 1 cm³/cycle pumps are pre-set to 1 cm³. For less delivery, remove lock screw, measure «A», turn adjusting screw clock wise increasing «A» by «X» dimension. 1.5 to 3.5 bars. Pressure varies depending on the number of meter units in the system. single phase : 50/60 Hz-3 W 115 V : connect wires to outlet 5 and 6. 220 V : connect wires to outlet 4 and 6. max power : 0.15 A / 220 V. Pumps are delivered with contact closed at the high position. Connect wire to terminal 2 et 3. 40 micron filters mounted at oil intake. 0.5 or 1 L The number of points which can be lubricated depends on the discharge setting of the pump. Mineral oil viscosity at working temperature must be between 30 to 1700 Cst. 1 / 6 P_2012_2_GB_TM1

HOW TO ORDER To define the exact pump characteristics, use the following code : Voltage Time Motor Part number Replacement (V) cycle R.P.M 0,5L 1L motor 115 145 1 C2889 D3087 19422-2 72 2 C2890 D3089 19422-3 18 8 C2891 D3090 19422-1 9 8 C2896 D3095 19422-1 115/220 2 60 C2895 D3094 24278-2 220 145 1 C2892 D3091 19306-2 72 2 C2893 D3092 24095-3 18 8 C2894 D3093 24095-1 9 8 C2897 D3096 24095-1 Example : TM1 pump with level switch, 220 V / 72 mn, Reference : C2893 TECHNICAL DRAWING TM1 0.5 L 2 / 6 P_2012_2_GB_TM1

SERVICE INSTRUCTION PUMP TM1 0.5 L System: Your machine is equipped with a Bijur centralised lubricating system wich, if properly maintained, will correctly lubricate all the points in the system. Oil: Use only clean mineral oil of a quality and viscosity as recommended by the machine builder. Theoil characteristics must allow filtering fltration down to 25 microns without it separating. Start up: Fill the reservoir after having primed the pump, check if the system has been pressurised. If it has not, check direction of rotation of the motor. Service: Check oil level daily. Check periodically the tubing to ensure none are broken or crushed and that they are in good condition. Make sure all fittings are correctly tightened. Any excess grease around the machine should be investigated immediately. Lack of oil at the lubrication points: Verify the oil level in the reservoir the distribution circuit (e-g look for broken, crushed, or detached tubing or a leak at one of the fittings). Check also the condition of the filter. To reduce or increase the amount of oil being delivered to any given point, change the value of the meter unit at that point. Filter: A filter is incorporated in the pump to protect the system. It must be checked peridicaly and replaced once a year. Motor replacement: Lift off motor cover. The moto his held in position by two screws which allows motor to be replaced without dismantling the pump. Spare parts: For ordering, specify reference and type of pump. If possible, also advise serial number of the pump. For all major repair, it is recommended that the pump be returned to Bijur. 3 / 6 P_2012_2_GB_TM1

TECHNICAL DRAWING PUMP TM1 1 L 4 / 6 P_2012_2_GB_TM1

SERVICE INSTRUCTION PUMP TM1 1 L System: Your machine is equipped with a Bijur centralised lubricating system wich, if properly maintained, will correctly lubricate all the points in the system. Oil: Use only clean mineral oil of a quality and viscosity as recommended by the machine builder. Theoil characteristics must allow filtering fltration down to 25 microns without it separating. Start up: Fill the reservoir after having primed the pump, check if the system has been pressurised. If it has not, check direction of rotation of the motor. Service: Check oil level daily. Check periodically the tubing to ensure none are broken or crushed and that they are in good condition. Make sure all fittings are correctly tightened. Any excess grease around the machine should be investigated immediately. Lack of oil at the lubrication points: Verify the oil level in the reservoir the distribution circuit (e-g look for broken, crushed, or detached tubing or a leak at one of the fittings). Check also the condition of the filter. To reduce or increase the amount of oil being delivered to any given point, change the value of the meter unit at that point. Filter: A filter is incorporated in the pump to protect the system. It must be checked peridicaly and replaced once a year. Motor replacement: Lift off motor cover. The moto his held in position by two screws which allows motor to be replaced without dismantling the pump. Spare parts: For ordering, specify reference and type of pump. If possible, also advise serial number of the pump. For all major repair, it is recommended that the pump be returned to Bijur. 5 / 6 P_2012_2_GB_TM1

6 / 6 P_2012_2_GB_TM1