GASTON COUNTY BUILDING INSPECTIONS MANUFACTURED HOME PERMIT REQUIREMENTS



Similar documents
Mobile Home Pre-Inspection Checklist

Uniform Construction Code (UCC) Manufactured Homes. Modular Homes. Building Permit Application Package

Chapter 3 Pre-Installation, Foundations and Piers

Building, Plumbing, Electrical and Residential Water and Sewer Inspection Requirements

Residential Deck Safety, Construction, and Repair

When is a Permit Required? What Types of Permits are Required? The most common types of projects that require permits are:

The Lambton County Homeowner's BUILDING PERMIT INFORMATION GUIDE

REQUIREMENTS FOR SUBMITTING PLANS FOR NEW CONSTRUCTION

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

For the purposes of this Part, the following words shall have the following meanings:

Uncovered Decks & Porches

Building Code Inspections and Fees

RESIDENTIAL/COMMERCIAL

COUNTY OF DUPLIN BUILDING INSPECTIONS DEPARTMENT PO BOX 950 KENANSVILLE, NC PHONE: (910) FAX: (910)

Vision Home Inspection

Chapter 7 Plumbing Connections

Botetourt County, Virginia. Frequently Asked Questions

Residential Foundations and Basements

EL LAGO BUILDING DEPARTMENT PERMIT ISSUANCE PROCEDURES As of February 20, 2013

Residential Plan Routing Information

STANDARD OPEN PATIO COVER

Botetourt County, Virginia. Residential Information Handout

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

CITY OF SELMA, TEXAS Inspection Checklist: Commercial

Bureau Veritas Contact Information

Elevating Your House. Introduction CHAPTER 5

State Fire Marshal s Office Inspection Program for Factory-Built Homes

EFFECTIVE FEBRUARY note: drainage permit required to call for a dampproof inspection

Specifications for Residential Property Owners Connection to New Public Sewer

Georgia Association of Home Inspectors

MOBILE HOME LAW. Revised November 2001

Botetourt County, Virginia. Manufactured Housing Building Permit Guidelines

I NI NP R Inspected Items

Does Wall Township require an inspection by the building department on resale of a home?

Uniform Construction Code (UCC) Building Permit Application Package

BUILDING PERMIT SPECIFICATIONS

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

The purpose of this document is to provide standards for persons requesting or subject to County building inspections.

Single Family Residential Building Permit Questions & Answers

Proposed Minimum Subterranean Termite Treatment Standards

SIERRA LAKES COUNTY WATER DISTRICT P.O. Box 1039, Soda Springs, CA (7300 Short Road, Serene Lakes)

Frequently Asked Questions

Gas Meter Clearances and Service Installation Requirements

PDmB, Inc. Definitions

SWIMMING POOL, SPA, & HOT TUB GUIDELINES

Residential Accessory Buildings

Self-Home Inspection Checklist

SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT

Residential Decks. Planning and Development Services Department

Pre-Drywall Inspection Report

2009 IECC Update. Scope. Content. International Energy Conservation Code

3. Contractor shall ensure that all permits are obtained prior to any construction. Contractor shall be responsible for all utility fees.

necessary for years of satisfactory service. SmartBlock insulating form concrete walls share the

Additions and Alterations

Arapahoe County Residential Water Heater Installation and Inspection Guide

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

Guidebook for General Requirements for Building in Gordon County

TYPICAL PATIO COVERS 111

Residential Building Permits

MANUFACTURED HOUSING USED AS DWELLINGS

COMMONLY USED RESIDENTIAL BUILDING CODES

C I T Y O F P E A R S A L L

CITY OF BERKELEY BUILDING PERMIT DETAILED CHECKLIST

Residential Building Permit Process

Applications for building permits will not be reviewed until all of the required information has been submitted.

Building Permit Application

SEPTIC SYSTEM CONSTRUCTION REQUIREMENTS ST. MARY S COUNTY HEALTH DEPARTMENT

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

Basement & Foundation Damage

BUILDING SAFETY UNIT

A Homeowner s Guide to Building Permits

Electrical Service Guidelines

EAST LYME HIGH SCHOOL

SECTION REMOVAL OR ABANDONMENT OF EXISTING UTILITIES AND UNDERGROUND STRUCTURES. 1. Trench excavation, backfill, and compaction; Section

City of Mt. Juliet Public Works

2010 Residential Water Heater Replacement Check List

MULTI-FAMILY, COMMERCIAL, INDUSTRIAL, AS GOVERNED BY THE BC BUILDING CODE PART 3

Building Permit Application Packet. BUILDING CODES Adopted by La Plata County For Enforcement In The Unincorporated Areas Of La Plata County

MANUFACTURED HOME INSTALLATION FOR PERMANENT FOUNDATIONS (TRANSVERSE FLOORS) (SUPPLEMENT TO MANUFACTURED HOME INSTALLATION MANUAL)

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

A HOMEOWNERS GUIDE TO BUILDING IN GREY HIGHLANDS

The minimum reinforcement for the stem wall is the placement of:

#1) BEFORE Purchasing Land Here Is A Checklist Of Things You Should Check

PROJECT TITLE : 2-STOREY RESIDENCE LOCATION : ALONG DAANG HARI,MOLINO.BACOOR,CAVITE OWNER : CUEVASVILLE REALTY

CONSTRUCTION PERMITS AND CERTIFICATES A Helpful Guide

SINGLE-FAMILY EARTHQUAKE (SEISMIC) RETROFITS

2. What building projects are exempted? (permit not required)

Gas Meter Clearances and Service Installation Requirements

Development Services City of Lawrence, KS

Structure Survey Findings:

International Greenhouse Company

Upper Southampton Township Department of Licenses and Inspections 939 Street Rd. Southampton, Pa Phone: Fax:

Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing

PANELIZED HOME INSTALLATION GUIDELINE

Town of Beaumont. Lot Grading Guidelines

INFORMATION BULLETIN NO.

Transcription:

GASTON COUNTY Department of Building Inspections Mailing Address: P. O. Box 1578, Gastonia, NC 28053-1578 Phone:(704) 866-3155 Street Address: 128 West Main Avenue, Gastonia, NC 28052 Fax:(704) 866-3966 MEMORANDUM TO: Manufactured Home Dealers, Set Up Contractors, Home Owners SUBJECT: Permit and Inspection Procedures for Manufactured Homes Attached is information that is designed to assist you in obtaining permits and inspections. We hope that you find this information helpful to you when you start the permit process or prepare to call for an inspection. The desire for Code Enforcement is to provide you with quality service while ensuring that the home meets the minimum State Building Codes for the citizens of Gaston County. Please read all of the information and especially note the deadline for calling an inspection request is 4:30 PM the day before the inspection. If you use the Interactive Voice Response System (Voice Permits) or request inspections over the internet, then the deadline is 7:30 AM the day of the inspection. If you have any questions feel free to call or visit our office between 8:30 AM and4:30 PM. Mon-Fri. GASTON COUNTY BUILDING INSPECTIONS MANUFACTURED HOME PERMIT REQUIREMENTS 1. Obtain Zoning Permit. Building Permits will not be issued without a valid Zoning Permit. County Zoning permits may be obtained in the same building as Building Permits. For information on County Zoning Permits, call 704-866-3075. For Zoning Permits in other town limits contact the Zoning Administrator of the town where you are building. 2. Obtain well and Septic Permits where required. Permit applications for these permits are available where County Zoning Permits are issued. Question about well and septic tank permits should be directed to the Environmental Health Division at 704-853-5200. 3. Submit House Plans for plan review. On modular homes, a floor plan with the third party certification is required. For HUD labeled homes, no plan is required. For questions about plan review, call 704-810-6415.

4. Contractors. Bring the names and N.C. State license numbers as well as phone numbers of all contractors that will be used on the job. Only a State licensed setup contractor and State licensed subcontractors may be used except those who meet the State exemption requirements. (Home owners performing their own work) 5. Building Permit- After all other required permits have been issued, all necessary information supplied and required fees paid, the building permit will be issued. 6. Inspections - Inspections are based upon the latest adopted editions of the 2004 N.C. State Regulations for Manufactured Homes, 2009 N.C. State Residential Code and the 2008 National Electrical Code. See attached inspections procedures. 7. Utilities - After all final inspections have passed, and Zoning criteria has been met with regards to the new UDO regulations for Mobile homes. Utility stickers will be applied to the electric meter base and gas meter connections. It is the responsibility of the contractor or home owner to contact the utility provider for connection. 8. Certificate of Occupancy - After all inspections have been completed and passed, a Certificate of Occupancy is issued for the residence. No building may be occupied prior to a Certificate of Occupancy being issued. GASTON COUNTY BUILDING INSPECTIONS MANUFACTURED HOME INSPECTIONS PROCEDURES Before calling for an inspection of your manufactured home, the following must be completed: If there are any discrepancies between this handout and the latest addition of the North Carolina Building Codes, then the Building Code will take precedence. FOOTING INSPECTION Required for any masonry skirting (refer to Articles 3.6.3 and 3.6.4 of the Regulations), perimeter foundations, and any additions such as porches, decks, garages, before any concrete is poured. The footing must meet all the requirements of N.C. Residential Building Code and be free of any loose soil, mud, water, roots or any other foreign matter. SET UP INSPECTION 1. All piers, anchors, tie down straps, shims, and any other foundation requirements are complete per manufacturers set up manual, or the 2004 State of North Carolina Regulations For Manufactured Homes Code Book 2. Water and sewer lines installed to the N.C. State Building Code. Insulate the water line above ground except in crawl spaces when masonry underpinning is used..

3. Sewer line and cleanouts installed and tested as required by the Manufactured Housing Revised Plumbing Test Requirements of July 8, 2004. If sewer line is not completed all the way to the septic tank or city sewer, a separate Sewer Tap inspection must be called for when complete and before covering ditch. 4. Water line installed to well or public water system per State Code. Ditch must be a minimum of 24 inches deep where well wire is installed in the same ditch. Leave ditches open for inspection. 5. Marriage wall connections and fasteners per manufacturer s setup manual, or The 2004 State of North Carolina Regulations For Manufactured Homes Code Book. Do not cover up end walls. 6. HVAC cross over ducts installed per State Code. Avoid kinks in the duct and use metal hanger straps that are a minimum of 1½ wide. 7. Install electrical bonding jumper between units with self tapping screws or star washers. Any other electrical installations under the home shall be complete per the 2008 NEC Code. 8. Install vapor barrier on the ground in the crawl space where required by the set up manual, or the 2004State of North Carolina Regulations For Manufactured Homes Code Book 9. Have the Manufacturers Installation Manual, soil compaction report and anchor torque test on site. The soil compaction test hole shall be visible to the inspector as per the N.C. State Building Code. FINAL INSPECTION 1. All electrical work must be completed to the 2008 NEC, including any exterior feeders such as well pumps and A/C units. 2. All porches, steps, and decks installed per State Code and Local Zoning regulations 3. Septic tanks and wells must have been inspected and passed by the Environmental Health Department. 4. All heating and air conditioning work is completed per State Code. 5. Final Zoning Inspection has passed 6. Leave a door unlocked

Manufactured Home SET UP INSPECTION check list 1. Manufacturers setup manual on site 2. Compaction Report on site with test hole identified 3. Test Probe Torque Values on site 4. Positive drainage of site on all four sides of home 5. Pier Footings, at least 6" deep and sized according to the setup manual 6. If Perimeter/curtain walls are over 40"in height must meet footings meet section 3.6.4 of the 2004 State of North Carolina Manufactured Home Code Book. 7. Pier and curtain walls less than 40 in height shall be min 8 wide and 4 thick with the bottom of the footing being a minimum of 12 below finished grade. 8. Perimeter/curtain wall footings inspected prior to pouring concrete 9. I-Beams a minimum of 12" above grade to the bottom of the beam 10. Must maintain a minimum of 18 from grade to the bottom of floor joist. 11. Pier Blocking, size and spacing according to setup manual 12. Wood caps, shims, wedges, according to manufacturer, combined total not to exceed 3 in thickness 13. Shims, wedges, must be of hardwood, at least 4 wide, 6" long, maximum 1 inch shim under beam 14. When more than one-fourth of the main I-Beam supports are greater than 36 in height, measured from grade to the underside of the beam, the Manufactured home stabilizing system shall be designed by a North Carolina registered engineer. 15. Tie Down Anchors- type, depth, and spacing according to manufacturer, or the 2004State of North Carolina Regulations For Manufactured Homes Code Book 16. Tie Down Straps, Type 1, Class B, grade 1 steel, 1-1/4 wide ASTM-D-3953 or equal 17. Tie Down Straps, angle is within required manufacturer specs. or cross strapped 18. Tie Down Straps, installed correctly with proper tension and approved connectors 19. Marriage wall connectors are installed in accordance with the manufacturer or the 2004State of North Carolina Regulations For Manufactured Homes Code Book 20. Marriage wall piers in place with location tags visible 21. Multi-section frame bonding in place with #8 copper attached with self tapping screws or star washers 22. Multi-section crossover HVAC duct connected, 12 A metal hanger straps used 23. Waterlines installed with shutoff valve within 3 ft. of access door 24. Waterlines installed 12" below grade 25. Ditches for water lines open for inspection 26. Well wire installed according to the latest NEC and at least 24" below grade 27. Sewer line installed and tested according to the manufacturer and the State plumbing Code. 28. Connections between PVC and ABS pipe may not be Glued must use approved connector. 29. Sewer lines supported every 4 ft. 30. Dryer duct installed on site is to be a solid 28 gauge metal vent to the outside. 31. Vapor Barrier installed on ground under home where required

Gaston County Building Inspections Manufactured Home FINAL INSPECTION checklist 1. Positive drainage of site on all four sides of home 2. Perimeter/curtain walls, meet Sections 3.6.3 and 3.6.4 of the N.C. Regulations for 3. Manufactured Homes or the N.C. Residential Code 4. All water and sewer connections completed 5. Home underpinned per zoning requirements 6. Final zoning inspection completed 7. All HVAC equipment installed and completed per manufacturers specs. and code 8. Electrical service installed per latest NEC codes 9. All other electrical work completed per the latest NEC codes 10. Landings 36 sq.ft. And smaller must meet Manufactured Home Code. 11.. Decks and porches over 36 sq.ft. meet N.C. Residential Code and Manufactured Home Code 12. May be Required to have a minimum 64 sqft masonry deck and masonry underpinning per Gaston County Zoning 13. Decks and porches entirely self supporting, cannot attach to home, unless Designed by a North Carolina Registered Engineer. 14. House numbers mounted within 3 feet of the door with 3 inch high numbers for private lots or at the lot entrance, electrical service or other conspicuous place in mobile home parks Most common inspection turndowns for manufactured housing 1. No positive drainage or incorrect positive drainage around home 2. Manufacturers set-up manual not on site 3. Missing or improper soil compaction test 4. Tie down strap angle out of range 5. Decks/ porches not built to N.C. Residential Code or Gaston County Zoning Ordinance 6. Piers and or foundation not backfilled and crawl space not raked smooth 7. Loose shims on piers 8. HVAC cross over duct improperly installed 9. Sewer and water lines covered up prior to inspection 10. Hangers on sewer pipe not to exceed 6 feet spacing 11. Masonry underpinning over 40 inches high does not meet section 3.6.4 of the 2004 State of North Carolina Manufactured Home Code. 12. Well pump not wired per NEC Code 13. Sewer line does not have a minimum of 3 inches of cover 14. Improper marriage wall connection 15. Steps not per code 16. Dryer vent not installed per dryer manufacturer s instructions 17. Utility ditches not backfilled at final inspection 18. House locked on final inspection