How To Install The Mira Discovery Thermostatic Bar Valve



Similar documents
ACE. PIVOT AND BI-FOLD DOOR Installation and User Guide. These instructions must be left with the user W2-D

Installation & User Guide BASIN AND BATH PILLAR TAPS THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER 1

V10 THERMOSTATIC SHOWER VALVE PRODUCT MANUAL

Coolflo Safe Touch Shower Mixing Valve ST20015CP

Design Utility Lever Thermostatic Bath Shower Mixer

Artisan Thermostatic basin mixer. Fitting Instructions & Contents List

Colonial Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts

Cadet Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference

Artisan Thermostatic Bath Shower Mixer

Mira Extra Bath and Thermostatic Shower Control

Safe Touch TMV3 Thermostatic Shower ST10010CP

STABITHERM INSTALLATION & SERVICE BOOKLET

Chill 4 Hole Bath Shower Mixer

Artisan Thermostatic bath shower mixer. Fitting Instructions & Contents List

THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

Thermostatic bar showers. Troubleshooting and maintenance

Liquorice Kitchen Sink Tap

Almond Kitchen Sink Tap

Apricot Kitchen Sink Tap

Thermostatic. THERMOSTATIC POWER SHOWER Installation and User Guide. These instructions are to be left with the user 1

PHOENIX TAPWARE. Gloss. Shower/Wall Mixer RRP: $ Product Code: Available Finishes: GS780. Chrome MATCH WITH...

Almond Kitchen Sink Tap

GLOSS SOAP DISH PRODUCT CODE: FINISH: GS895 CHROME CONTEMPORARY DESIGN PHOENIX WARRANTY STYLISH PREMIUM CHROME FINISH MATCH WITH...

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

SHOWERS MIXER SI-IOWER GUIDE. Opi!3r~tiqn & Maintenance

Apricot Kitchen Sink Tap

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

AIRE Thermostatic bath shower mixer Installation and operating instructions

SF15K SF05KSS, SF10KSS

REDRING POWERSTREAM-ECO UNVENTED INSTANTANEOUS WATER HEATER. Installation and User Guide

Assembly and instructions

PBX Series Quick Fit Connector Bimetallic Steam Traps

Speedflow Undersink Unvented Water Heater. Models SF10K and SF15K. Instruction Manual

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

Installation Instructions S

Troubleshoot resources for homeowner

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

SHOWERS SHOWERS

Shower Handbook (Also covers 650 chrome variant)

Installation guide Nordic mixer taps. Before installing read this guide first

Baxi Combi Instant 80e & 105e. User s Operating Instructions. Gas Fired Wall Mounted Combination Boiler

Baxi Combi 80e & 105e

IMPORTANT INFORMATION

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

Electronically Controlled Instantaneous Water Heaters Models: DEX & DBX

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

Installation Instructions

Close Coupled & Back To Wall WC Saintaryware. Fitting Instructions

INSTALLATION INSTRUCTIONS BL-8704

Visage. Digital. Exposed with adjustable height head. Visage Digital exposed installation instuctions page 1

Please read and keep these instructions. Run water through your machine before first use

SunMaxx Solar Filling Station Operating Instructions

INSTALLATION INSTRUCTIONS MK-8704

SELECTION, APPLICATION & MAINTENANCE

Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1

MODEL VG08008 CONTENT PACKING LIST / TOOLS NEEDED PANEL DIMENSIONS FITTINGS / TECHNICAL DATA WALL/CORNER INSTALLATION CARE AND TROUBLE SHOOTING

SHOT BLAST CABINET MODEL NO: CSB20B

Installation, Operating and Servicing Instructions. Electric Auto-Fill Push Button Water Boilers EB3F/PB and EB3F/PBM

ClearView 100. Instruction Manual

TOLL FREE: (866) VANITY SPECIFICATIONS. VANITY COMPONENTS Model VG09042K1

INSTANT HOT WATER RECIRCULATING SYSTEM

COASTLINE QUADRANT ENCLOSURE. Installation / Maintenance Instructions Rev

Baxi Combi 130 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Combination Boiler

Installation Instructions and User Guide

Beautifully Traditional

MIRA'S GUIDE TO MIXER SHOWERS

AMX300 DirectConnect Mixing Valve Kits

Portable Air Conditioner

ATTENTION This is a general warning that failure to follow instructions could result in poor functioning of the unit.


Rapide Inline Ceiling Extractor Fan, White Fascia Rapide Inline Ceiling Extractor Fan, Chrome Fascia

USERS GUIDE. LOGIC Heat 12, 15, 18, 24, 30. For installation guide see reverse of book

SELECTION, APPLICATION AND MAINTENANCE

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.

Getting the best from your urn

BACKPACK SPRAYERS. MODEL NOS: KSP16 & KSP20 Part Nos: & OPERATING & MAINTENANCE INSTRUCTIONS GC04/12

Morco House Riverview Road Beverley HU17 0LD

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

100 Series Maxi Internal Filters. Instruction Manual

OWNER S MANUAL. FOOTWORKS tm Faucet Controller. Foot Operated Faucet Control Valves for Commercial Sinks

San josé OWNER S MANUAL

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

Combi 30 HE. User s Guide and Important Warranty Information

PLUMBING CARE AND REPAIR

Installation Instructions

Wetroom Panel (Concealed Fix)

Installation Instructions / Warranty

SERVICE MANUAL Order No.WH0911S001V0

LUCCI AIRFUSION QUEST II CEILING FAN

Awning Instructions. Standard Manual 1.5m to 4.5m

Duo-tec Combi HE A Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Combination Boiler

Stainless Steel Single and Dual Circulation Kits

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL

HAIR CLIPPER. Model No. HC5150 HC

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping

CARING FOR YOUR WATER HEATER

INSTALLATION INSTRUCTIONS

Transcription:

Thermostatic Bar Valve Installation and User Guide These instructions are to be left with the user 1

Contents Introduction...3 Guarantee...3 Recommended Usage...3 Patents...3 Safety : Warnings...4 Pack Contents...5 Dimensions...5 Specifications...6 Installation...7 General...7 Solid Wall Installation...8 Stud Partition, Laminated Panel, or Unfixed Rear-entry Pipework Installation...9 Assembly of Control Knobs... 11 Operation...12 Adjusting the Temperature...12 Adjusting the Flow...12 Commissioning...13 Setting the Maximum Temperature...13 Fault Diagnosis...14 Maintenance...15 Type 2 Valves...18 Spare Parts...19 Accessories...20 Notes...21 Customer Service...Back Page 2

Introduction Thank you for purchasing a quality Mira product. To enjoy the full potential of your new product, please take time to read this guide thoroughly, having done so, keep it handy for future reference. The Mira Discovery Thermostatic Bar Valve is a Thermostatic Shower Control designed for wall mount installations. The Thermostatic Bar Valve has two knobs, one knob controls the flow and the other knob controls the temperature. The Thermostatic Bar Valve incorporates a wax capsule temperature sensing unit, which provides an almost immediate response to changes in pressures or temperature of the incoming water supplies to maintain the selected temperature. An adjustable maximum temperature stop is provided which limits the temperature to a safe level. Inlet Filters are fitted to protect the thermostatic cartridge. This product has been certified as a Type 2 valve under the BUILDCERT TMV2 scheme. This product also complies with the Water Supply (water fittings) Regulations 1999. Guarantee For domestic installations, Mira Showers guarantee the Mira Discovery Thermostatic Bar Valve against any defect in materials or workmanship for a period of three years from the date of purchase (shower fittings for one year). For non-domestic installations, Mira Showers guarantee the Mira Discovery Thermostatic Bar Valve against any defect in materials or workmanship for a period of one year from the date of purchase. For terms and conditions refer to the back cover of this guide. Recommended Usage Patents Application Domestic Light Commercial Heavy Commercial Healthcare Valve with Fittings ü ü û û Patents GB 2 407 138 If you experience any difficulty with the installation or operation of your new Thermostatic Mixer, please refer to Fault Diagnosis, before contacting Kohler Mira Ltd. Our telephone and fax numbers can be found on the back cover of this guide. 3

Safety : Warnings This Mira Discovery Thermostatic Bar Valve is precision engineered and should give continued safe and controlled performance, provided: 1. It is installed, commissioned, operated and maintained in accordance with manufacturers recommendations. 2. Periodic attention is given, when necessary, to maintain the product in good functional order. Caution! 1. Read all of these instructions. 2. Retain this guide for later use. 3. Pass on this guide in the event of change of ownership of the installation site. 4. Follow all warnings, cautions and instructions contained in this guide. 5. Anyone who may have difficulty understanding or operating the controls of any shower should be attended whilst showering. Particular consideration should be given to the young, the elderly, the infirm or anyone inexperienced in the correct operation of the controls. 6. When this product has reached the end of its serviceable life, it should be disposed of in a safe manner, in accordance with current local authority recycling, or waste disposal policy. 4

Pack Contents Tick the appropriate boxes to familiarise yourself with the part names and to confirm that the parts are included. 1 x Mira Discovery Bar Valve 1 x Flow Knob 1 x Temperature Knob 2 x Concealing Plates 2 x Inlet Seals / Filters 2 x Wall Mounting Brackets 2 x Offset Connectors Documentation 1 x Guarantee Brochure Dimensions 150 mm ± 15 mm 1/2 BSP 107 mm 80 mm Ø 70 mm 287 mm 5 1/2 BSP

Specifications For Type 2 Valves, the supply conditions specified in section: Type 2 Valves - Application take precedence over the operating parameters which follow. Pressure Range Minimum maintained pressure: 0.2 bar (2.0 metre head). Maximum maintained pressure: 5.0 bar. Maximum static pressure: 10 bar. Note! Nominally equal inlet supply pressure are recommended for optimum performance. Temperature Control Close temperature control is provided between 20 C and 50 C. Note! The temperature control specification, outlined below, is achieved with the blend between 35 C and 45 C, and supply temperatures of 15 C cold and 65 C hot, AND, nominally equal inlet supply pressures. The blended temperature is maintained within 2 C with a 10 C change in the hot or cold supply. The wax capsule sensor effects a shut down to seepage in approximately 2 seconds if the cold supply fails. Shut down to seepage is only achieved if the hot supply is 10 C above the blend temperature. Minimum hot water supply temperature: 55 C Maximum hot water supply temperature: 90 C for short periods. BS 6700 recommends that the temperature of stored water should never exceed 65 C. A stored water temperature of 60 C is considered sufficient to meet all normal requirements and will minimise the deposition of scale in hard water areas. Connections Connections are: Hot - Left (side nearest flow control), ½" BSP Male. Cold - Right (side nearest temperature control), ½" BSP Male. Bottom-Outlet, ½" BSP Male. Note! This product does not allow for reversed inlets. Offset connector (inlet centres are 150 mm ± 24 mm): ¾" BSP Connection to Bar Valve 6 ½" BSP Connection to Pipework

General Installation The Control Knobs will require fitting prior to use refer to section: Assembly of Control Knobs for instruction. Installation must be carried out in accordance with these instructions, and must be conducted by designated, qualified and competent personnel. The installation must comply with the Water Supply Regulations 1999 (Water Fittings) or any particular regulations and practices, specified by the local water company or water undertakers. Note! Make sure that all site requirements correspond to the information given in section: Specifications. For Type 2 Valves see also supply conditions in section: Type 2 Valves. 1. The Bar Valve must not be installed in an area where it may freeze. 2. For stud partitions alternative fixings may be required. 3. Isolating valves must be installed close to the Bar Valve for ease of maintenance. 4. Pipework must be rigidly supported and avoid any strain on the connections. 5. Pipework dead-legs should be kept to a minimum. 6. Supply pipework layout should be arranged to minimise the effect of other outlet usage upon the dynamic pressures at the Mixer inlets. 7. Inlet and outlet threaded joint connections should be made with PTFE tape or liquid sealant. Do not use oil-based, non-setting joint compounds. 8. To eliminate pipe debris it is essential that supply pipes are thoroughly flushed through before final connection. 9. Decide on a suitable position for the Bar Valve. The position of the Bar Valve and the Shower Fittings must provide a minimum gap of 25 mm between the spill-over level of the Hose Retaining Ring shower tray/bath and the handset. This is to prevent back-siphonage. For further information on the installation of your Shower Fittings, refer to the Fittings Installation and User Guide. Note! Only use Shower Fittings recommended by the manufacturer or supplier. 25 mm Spill Over Level 7

Solid Wall Installation For Solid Wall installations the Thermostatic Bar Valve can be supported by the pipework provided that it is securely fixed to the wall. Alternatively for unfixed rear entry pipework the Wall Mounting Bracket can be used. For installation onto a Stud Partition, Laminated Panel, or onto Unfixed Rear entry Pipework (using the Wall Mounting Bracket) refer to section: 'Stud Partition, Laminated Panel, or Unfixed Rear-entry Pipework Installation'. 1. Install the pipework, make sure that it is set at the correct distance apart (150 ± 24 mm) and solidly fixed as this supports the valve. ½" BSP Female Connection Offset Connector 150 ± 24 mm Pipe Centres in Wall Ø 22 mm Tile 2. Apply suitable thread sealant (not supplied) and attach the Offset Connectors to the pipework in the wall. Note! Connections are: Hot-Left, Cold-Right, Bottom-Outlet. Support Bracket Spirit Level Pipework Wall Apply Silicone Sealant 3. Tighten the Offset Connectors using a spanner on the spanner flats. Make sure that the Connectors are level and set at the correct distance apart, using the Bar Valve as a guide to spacing. Spanner Flats 150 mm 4. Screw the Concealing Plates onto the Offset Connectors until they come into contact with the wall. 5. Install the Bar Valve, refer to section: Stud Partition, Laminated Panel, or Unfixed Rear-entry Pipework Installation and follow instructions 9 to 12. Concealing Plates Wall Mounting Bracket (Alternative Fixing Method) 8

Stud Partition, Laminated Panel, or Unfixed Rear-entry Pipework Installation For all installations using the Wall Mounting Bracket: 150 ± 24 mm 1. Install the pipework, make sure that Pipe Centres in Wall it is set at the correct distance apart (150 ± 24 mm) and solidly fixed. 2. Screw the Mounting Brackets onto the Offset Connectors to the depth Ø 27 mm shown in the illustration. 3. The Mounting Bracket must extend in the same direction as the offset of the Offset Connector. The angle between the Offset Connector and the Mounting Bracket must be less than 45, otherwise the Mounting Bracket will not fit under the Concealing Plate. Offset Connector 45 35-40 mm Wall Mounting Bracket 45 4. The Mounting Bracket Boss should protrude to the rear, facing the wall. 5. Apply suitable thread sealant (not supplied) and attach the Offset Connectors to the pipework in the wall. Note! Connections are: Hot-Left, Cold-Right, Bottom-Outlet. 10 mm ½" BSP Female Connection Wall Boss Offset Connector Spirit Level Wall Mounting Bracket 150 mm Support Bracket Apply Silicone Sealant Pipework 9

6. Tighten the Offset Connectors using a spanner on the spanner flats. Make sure that the Connectors are level and set at the correct distance apart, using the Bar Valve as a guide to spacing. 7. Fix the Mounting Bracket to the wall through the small hole, using the appropriate wall fixings for the type of wall (not supplied). Caution! Take care not to drill though any concealed pipework. 8. Screw the Concealing Plates onto the Offset Connectors until they come into contact with the wall. Spanner Flats 35-40 mm Concealing Plates 9. Caution! Make sure that the supply pipework is flushed before installing the Bar Valve. Assemble the Bar Valve with a Sealing Washer / Filter in each inlet and attach to the Offset Connectors. 10. Tighten the connection using a 20 mm spanner. 11. Install the Shower Fittings, refer to the Shower Fittings Installation and User Guide. 12. Turn on the water supplies and check for leaks at all pipe connections. Outlet Sealing Washer / Filter Bar Valve 10

Assembly of Control Knobs Flow Knob 1. Rotate the Flow Hub fully clockwise. 2. Both the Bar Valve and the Flow Knob have a flow stop marking, align both of the marks and push the Flow Knob until it locks onto the flow hub. Flow Hub Flow Knob Align Flow Stop Marks Temperature Knob 1. Rotate the Temperature Hub fully anti-clockwise. 2. Hold the Bar Valve with the Outlet facing down then align the red temperature marking on the Temperature Knob toward the Bar Valve as illustrated. 3. Push the Temperature Knob onto the Bar Valve until it locks onto the Temperature Hub. Temperature Hub Temperature Marking (red) Temperature Knob Outlet Connector 11

Adjusting the Temperature Operation The temperature is controlled by rotating the temperature control knob on the right side of the shower. Adjusting the Flow The flow is controlled by rotating the flow control knob on the left side of the shower. Increase Temperature Off/Decrease Flow Decrease Temperature On/Increase Flow Flow Control Knob Temperature Control Knob 12

Commissioning Setting the Maximum Temperature The Mira Discovery Thermostatic Bar Valve has been preset to a safe showering temperature under ideal conditions at the factory, appropriate for most systems. However, site conditions and personal preference may make it necessary to reset this temperature. Caution! Before testing the mixer, make sure that the hot and cold water are flowing correctly by turning the temperature selector knob between the cold and hot stops. For Type 2 installations the maximum blend temperature is determined by the application, refer to section: Type 2 Valves - Application. 1. Turn on the shower. 2. Turn the temperature selector knob to full hot and test the temperature of the water from the shower outlet. If the water is not at the required temperature, proceed with the following procedure. 3. Turn off the shower. 4. Carefully pull off the temperature control knob. Note! Force will be required to pull the temperature control knob from the shower. 5. Unscrew the hub retaining screw. 6. Remove the temperature hub and replace it one spline clockwise to increase the temperature. Note! One spline clockwise equals approximately, 2 C increase in temperature. 7. Tighten the hub retaining screw. 8. Install the temperature knob. Make sure that the stop feature inside the knob is towards the top. 9. Turn on the shower and check the maximum temperature setting. If further adjustment is required repeat the above procedure. Hub Retaining Screw Temperature Control Knob Splines Temperature Hub 13

Symptom 1. Only hot or cold water from mixer outlet. 2. Fluctuating or reduced flow. 3. N o f l o w f r o m mixer outlet. 4. Blend temperature drift. 5. Maximum blend t e m p e r a t u r e setting too hot or too cold. 6. Drip from handset. Fault Diagnosis Cause / Rectification a. Inlet supplies reversed / change pipework. b. Faulty Non-Return Valve. c. Check that the Inlet Filters are not blocked. a. Check that the Inlet Filters are not blocked. b. Make sure that the minimum flow rate is sufficient for the supply conditions. c. Make sure that the maintained inlet pressures are nominally balanced and sufficient. d. Make sure that the inlet temperature differentials are sufficient. e. Airlock or partial blockage in pipework. a. Make sure that the Inlet Isolating Valves are open. b. Hot or cold supply failure. Make sure that hot and cold supplies are available. c. Refer to symptom 2. a. Inlet supplies reversed. b. Hot supply temperature fluctuation. c. Supply pressures fluctuating. d. Thermal Cartridge defective. e. Inlet Filters Blocked. a. Indicates incorrect maximum temperature setting, refer section: 'Commissioning'. b. Refer to symptom 4. a. A small amount of water may be retained in the fitting after the shower control has been turned off. This may drain over a few minutes. This is quite normal. Changing the angle of the shower fitting may vary the draining time. b. Defective ceramic plates within the shower cartridge. c. Renew the cartridge assembly. 14

Maintenance General This Product is precision engineered and should give continued safe and controlled performance, provided: 1. It is installed, commissioned, operated and maintained in accordance with manufacturers recommendations. 2. Periodic attention is given, when necessary, to maintain the product in good functional order. If you require a Mira trained engineer or agent, refer to section: Customer service. Lubricants Silicone based lubricants must only be used on the rubber seals. Caution! Oil based or other lubricant types may cause rapid deterioration of seals. Cleaning The chrome plated parts should be cleaned using a mild washing up detergent or soap solution, rinsed and then wiped dry with a soft cloth. Warning! Many household cleaners contain abrasive and chemical substances, and should not be used for cleaning plated or plastic fittings. Do not use descalents on this product. In-service Tests The principal means for determining the continuing satisfactory performance of the mixing valve is the in-service test. Follow the procedure detailed in the flow diagram In-service Test Procedure. Frequency of In-service Tests Commercial (non-domestic installations) Check for correct blend setting every 6 months. Follow the procedure detailed in the flow diagram In-service Test Procedure, every 12 months. 15

Start Measure and record supply temperatures and pressures. Make sure that they are within Valve specifications. Measure and record blend temperature (Tb) and flow rate. Has flow rate fallen significantly or fallen below minimum flow specification? No Yes Check and clean checkvalves, strainers and outlet. Measure and record blend temperature (Tb) and flow rate. Yes Has flow rate improved? Carry out a performance check. Refer to the commissioning procedure. No Has the blend temperature changed by more than 2 C from previous recorded value (Tb)? Yes No Finish Refer to section: Fault Diagnosis. Carry out the commissioning procedure. Note! All measurements and results should be recorded in the Log Book. Flow Diagram, In-service Test Procedure 16

Maintaining the Non-Return Valves The Non-Return Valves are located in the Bar Valve Body, and are accessible through the Inlet Connectors. Caution! Make sure that the Non-Return Valves are installed correctly to prevent crossflow or malfunction of the Valve. 1. With the water supplies turned off and the Thermostatic Bar Valve removed, remove the Washer / Filter, and the Circlip 2. Carefully remove the Non-Return Valve and clean any debris. 3. On re assembly make sure that the Non-Return Valve is fitted the correct way round (with the arrow indicating the flow pointing towards the Valve). Flow Arrow Circlip Non-return Valve Washer / Filter Filters The Inlet Washers / Filters are located in the Inlet Connector. Clean or renew as necessary. Thermostatic Cartridge In hard water areas the Filters in the Thermostatic Cartridge may become blocked with limescale, which will reduce the flow of water. It is recommended that the Cartridges are checked regularly and cleaned in a descaling solution (such as kettle descalent) if necessary. Be sure to follow the manufacturer s instructions on the descalent package. Note! The Thermostatic Cartridge is non-servicable and will require replacement should failure occur. 17

Type 2 Valves Application The approved designations for Type 2 Valves are as follows: Model Mira Discovery Bar Valve HP-S The permitted application details are: Designation Operating Pressure Range Application Designation Mixed Water Temperature C HP-S Low Pressure Shower 41 C Maximum Mixed water temperature at discharge point. Important! For TMV2 installations the mixed water temperature at the discharge point should never exceed 46 C. In order to achieve the safe water temperatures expected of a Type 2 Valve it is essential that the valve is used only for the applications covered by its approved designations, with the appropriate water supply pressures and temperatures, and it is commissioned, maintained and serviced in accordance with the recommendations contained in this guide (refer to the section Maintenance, In-Service Tests for in service test frequency that must be used as a minimum guide in Type 2 installations). Supply Conditions For applications where a Type 2 Valve is required, the supply conditions must comply with the values in the Table below. Note that both hot and cold supply pressures must lie within the same pressure range. Operating Pressure Range Maximum Static Pressure (bar) Maintained Pressure, Hot and Cold (bar) Hot Supply Temperature ( C) High Pressure Low Pressure 10 10 1 to 5 0.2 to 1 55 to 65 55 to 65 Cold Supply 25 25 Temperature ( C) Valves operating outside these conditions cannot be guaranteed to operate as Type 2 Valves. 18

Spare Parts 456.22 Non Return Valve Assembly 456.28 Outlet Connector 456.29 Wall Mounting Bracket 467.01 Thermostatic Cartridge Assembly 467.04 Flow Cartridge Assembly 1609.030 Offset Connector Kit 1609.031 Temperature Knob 1609.032 Flow Knob 1609.030 1609.031 456.22 456.29 467.01 456.28 467.04 1609.032 19

ACCessorIes Genuine Mira accessories can be purchased direct from Customers Services (our contact details can be found on the back cover of this guide) or from approved stockists or merchants. eco showerhead White - 2.1668.001 Chrome - 2.1668.002 The Eco shower head gives you an invigorating shower, but reduces water consumption and heating costs. everclear showerhead White - 2.1616.030 Chrome - 2.1616.031 Mira's new Everclear range has been specially designed for hard water areas and reduces the risk of lime scale build up. showerhead Holder White - 1.1540.270 Chrome - 1.1540.271 An alternative to the traditional slide bar. Often a useful addition when positioned for the smaller members of the family. Wall Mounted soap Dish White - 1.1540.278 Chrome - 1.1540.279 Wall mounted for use anywhere in, or outside the showering area. shower seat White - 2.1536.128 White/Chrome - 2.1536.129 For use in or out of the showering area. note! must be installed onto a solid wall. Shower seat folds up when not in use Double outlet Check Valve (DCV-H) Chrome - 1.0.110.55.1 DCV-H: An outlet double check valve, designed to prevent the backfl ow or backsiphonage of potentially contaminated water, through shower controls which are fi tted with a fl exible hose as part of the outlet shower fi tting. 201

notes 21

notes 22

notes 23

Customer Service Guarantee Your product has the benefit of our manufacturer s guarantee which starts from the date of purchase. To activate this guarantee, please return your completed registration card, visit our website or free phone 0800 0731248 within 30 days of purchase (UK only). Within the guarantee period we will resolve defects in materials or workmanship, free of charge, by repairing or replacing parts or product as we may choose. This guarantee is in addition to your statutory rights and is subject to the following conditions: The product must be installed and maintained in accordance with the instructions given in this user guide. Servicing must only be undertaken by us or our appointed representative. note! if a service visit is required the product must be fully installed and connected to services. Repair under this guarantee does not extend the original expiry date. The guarantee on any replacement parts or product ends at the original expiry date. For shower fi ttings or consumable items we reserve the right to supply replacement parts only. The guarantee does not cover: Call out charges for non product faults (such as damage or performance issues arising from incorrect installation, improper use, lack of maintenance, build up of limescale, frost damage, corrosion, system debris or blocked fi lters) or where no fault has been found with the product. Water or electrical supply, waste and isolation issues. Compensation for loss of use of the product or consequential loss of any kind. Damage or defects caused if the product is repaired or modifi ed by persons not authorised by us or our appointed representative. Routine maintenance or replacement parts to comply with the requirements of the TMV 2 or TMV 3 healthcare schemes. What to do if something goes wrong If your product does not function correctly when you fi rst use it, contact your installer to check that it is installed and commissioned in accordance with the instructions in this manual. Should this not resolve the issue, contact our Customer Services Team who will offer you or your installer advice and if applicable arrange for a Service Technician to call. If the performance of your product declines, check in this manual to see if simple home maintenance is required. If you require further assistance call our Customer Services Team. Extended Guarantees A selection of protection plans are available that enable you to cover repair bills for the life of your policy (excludes Eire). Ring 01922 471763 for more details. Helpdesk service Our dedicated Customer Services Team is comprehensively trained and can offer help and advice, spare parts, accessories or a service visit. We will need you to have your model name or number, power rating (if applicable) and date of purchase. As part of our quality and training programme calls may be recorded or monitored. Mira showers Website (www.mirashowers.co.uk) From our website you can register your guarantee, download additional user guides, diagnose faults, purchase our full range of accessories and popular spares, refer to our FAQ s and request a service visit. spares and Accessories We maintain extensive stocks of genuine spares and accessories and aim to provide support throughout the product s expected life. Payment can be made by phone at time of order using most major Credit or Debit cards and we aim to despatch orders within two working days. Items purchased from us are guaranteed for 12 months from date of purchase. For safety reasons spares exposed to mains voltages should only be fi tted by competent persons. returns items can be returned within one month of date of purchase, providing that they are in good condition and the packaging is unopened. Please obtain authorisation from our Customer Services Team before return. We reserve the right to apply a 15% restocking charge. service / repairs We have a nationwide team of Service Technicians who can carry out all service or repair work to your product within the guarantee period and beyond. You have the assurance of a fully trained Mira Technician, genuine Mira spare parts and a 12 month guarantee on any chargeable work done. Payment should be made directly to the Service Technician who will accept most major Credit or Debit cards. To Contact us uk Telephone: 0844 571 5000 Mon to Fri 8:00 am - 5:30 pm, Sat 8:30 am - 3:30 pm E-mail: technical@mirashowers.com Fax: 01242 282595 By Post: Mira Customer Services Dept, Cromwell Road, cheltenham, Gloucestershire, Gl52 5eP eire Telephone: 01 459 1344 Mon to Fri 9:00 am - 5:00 pm E-mail: sales@modernplant.ie Fax: Dublin 01 459 2329 By Post: Modern Plant Ltd (Dublin), Otter House, Naas Road, Clondalkin, Dublin 22 Mira is a registered trade mark of Kohler Mira Limited. The company reserves the right to alter product specifi cations without notice. UKAS 1054969-W2-C (B92B) (1609) 24 Kohler Mira Limited, July 2009