Lewatit DW 630 will not significantly exchange any major water constituents (Cl -, HCO 3-



Similar documents
Lewatit MP 62 is especially suitable for:

Lewatit MonoPlus SP 112 H is especially suitable for:

This document contains important information and must be read in its entirety. Edition: Previous Edition: /4

C-100E Strong Acid Cation Exchange Resin (For use in water softening applications)

Ion Exchange Design Hand calculation. Brian Windsor (Purolite International Ltd)

Ion Exchange RESIN SELECTION. Marc Slagt Technical Support Specialist DOW Water & Process Solutions

ION EXCHANGE FOR DUMMIES. An introduction

Dow Liquid Separations DOWEX MARATHON MSA. Ion Exchange Resin. Engineering Information

DEIONIZATION IN A "NUT SHELL"

Dow Liquid Separations DOWEX MARATHON A. Ion Exchange Resin ENGINEERING INFORMATION

Resin Types and Production. Brian Windsor (Purolite International Ltd)

Dow Liquid Separations DOWEX SBR-P. Ion Exchange Resin ENGINEERING INFORMATION

How To Remove Iron From Water

ION EXCHANGE RESINS INTRODUCTION

SODIUM CATION EXCHANGE (ZEOLITE) WATER SOFTENING PROCESS

Ion Exchange Softening

Eye On Water. New Options for Removal of Trace Contaminants see page 1. Producing Spot-Free Rinse Water for Consumer Applications see page 1

Wastewater Reuse. Typical treated wastewater is:

1. Inspection and monitoring... 3

Culligan Exchange Tank Deionization Service

Sources of TOC in Deionized Water

Hardness ions also interfere with many chemical processes such as chemical compounding and aqueous cleaners.

Safety Data Sheet Avesta Neutralization Agent 502

Solid Phase Extraction Products PAGE: 1. Introduction of Solid Phase Extraction (SPE) Why Choose Nano-Micro Tech SPE

DOWEX Resins as Organic Solvent Desiccants

Issue Date: 04-Oct-2013 Revision Date: 19-Nov-2014 Version Number: Identification. 2. Hazards Identification

UPCORE System. Suspended Solids Removal for Countercurrent Ion Exchange Systems

Calcite PH Nutralizer System

Water Softening for Hardness Removal. Hardness in Water. Methods of Removing Hardness 5/1/15. WTRG18 Water Softening and Hardness

Well Water Iron Removal Using Quantum DMI-65 Granular Filter Media

Remediation of VOC Contaminated Groundwater

AMBERLITE IRP64 Pharmaceutical Grade Cation Exchange Resin (Polacrilex Resin)

RESOURCE Q, 1 ml and 6 ml RESOURCE S, 1 ml and 6 ml

CHEMICAL DETERMINATION OF EVERYDAY HOUSEHOLD CHEMICALS

Coagulation and Flocculation

GUIDELINES FOR SELECTING RESIN ION EXCHANGE OR REVERSE OSMOSIS FOR FEED WATER DEMINERALISATION

APPLICATION GUIDE Choosing an ion exchange system for nitrate removal

Removing Thallium from Industrial FGD Scrubber Water with Sorbster Adsorbent Media

EG-SAFETY DATA SHEET (91/155/EWG)

: Fairy Professional Original Washing Up Liquid 5L

Purolite Water Softening Resin Guide By: Chubb Michaud

Troubleshooting Your RO

Feasibility study of crystallization process for water softening in a pellet reactor

The Relationship between ph and Deionized Water

ESP FLOWSHEET SIMULATION APPLICATION BRIEF Downhole Oil/Water Separation

SAFETY DATA SHEET Glen-Pak TM DNA purification cartridge (for use with disposable syringes) xx

BIO BASIC INC. 20 KONRAD CRES, MARKHAM ONTARIO L3R 8T4 CANADA TEL: (905) , (800) FAX: (905)

Fixapret NF. Technical Information

AMBERLITE IRP69 Pharmaceutical Grade Cation Exchange Resin (Sodium Polystyrene Sulfonate USP)

Environmental Water Testing: Surface Water, Groundwater, Hard Water, Wastewater, & Seawater

Exampro GCSE Chemistry

Main Drain Opener Safety Data Sheet

Material Safety Data Sheet

Experiment 8 - Double Displacement Reactions

MATERIAL SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET

ph Alkalinity of Water

ADDIT Last update: 20/04/2010, version 2.0 page 1 / 5

The design for ion exchange column

Equilibria Involving Acids & Bases

Separation by Solvent Extraction

Corrosion Management in Gas Treating Plants (GTP s): Comparison between Corrosion Rate of DEA and MDEA A Case Study in Sour Gas Refinery

Dissolved and precipitated oxalate

Lenntech. Dow Water Solutions. FILMTEC Membranes. Product Information Catalog

SAFETY DATA SHEET TIDYFOAM E2 HAND CLEANER SANITIZER

Material Safety Data Sheet. Accepta Statham House Talbot Road Manchester M32 0FP

2.500 Desalination and Water Purification

MATERIAL SAFETY DATA SHEET

Chemistry at Work. How Chemistry is used in the Water Service

Safety Data Sheet UN-GHS (Rev.4) (2011) Update: Version: 1.3

DIAMOND POWDER - MICRON

Dissolved Mineral Radioactivity in Drinking Water

Inferred ph in Steam Plant Water Chemistry Monitoring

Quickstart. English Deutsch Français

Safety Data Sheet in accordance with regulation (EC) 1907/2006 Update: Version: 1.2 Kresto kwik-wipes [ KRESTO KWIK-WIPES ] Page 1 of 6

Safety Data Sheet VAULT SP FOR SOYBEAN Revision date : 2014/09/01 Page: 1/9

CHAPTER 7 THE DEHYDRATION AND SWEETENING OF NATURAL GAS

A NOVEL ION-EXCHANGE/ELECTROCHEMICAL TECHNOLOGY FOR THE TREATMENT OF AMMONIA IN WASTEWATER

Stalosan F Safety Data Sheet 1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING

SAFETY DATA SHEET nedmag C magnesium chloride flakes/pellets

Safety Data Sheet. EPSON INK CARTRIDGE T220XL220 Ink for Epson Printers. Proprietary organic materials none. Glycerols none

advice (show the label where possible).

This SDS adheres to the standards and regulatory requirements of Great Britain and may not meet the regulatory requirements in other countries.

SAFETY DATA SHEET Enz-Extract Enzyme Carpet Extractor. 1. Product and Company Identification. 2. Hazards Identification

INSTRUCTIONS Edition AC

: MR MUSCLE Window & Glass Cleaner

New Blond Base Lift Cream 60ml. Linthicum Heights, MD Phone: Fax:

GPS Safety Summary. Hydrogen Chloride/Hydrochloric Acid. HCl

Issue Date: 01-Sep-2012 Revision Date: 23-Apr-2014 Version 1 1. IDENTIFICATION. Slide Veri-Kleen Contact Cleaner 2. HAZARDS IDENTIFICATION

A meaningful, cost-effective solution for polishing reverse osmosis permeate

: Water and Glycol Leak Detection Solution

HiPer Ion Exchange Chromatography Teaching Kit

SHOUT TRIPLE-ACTING LAUNDRY STAIN REMOVER

Issuing Date: 18-Feb-2015 Revision Date: 18-Feb-2015 Version 1 1. IDENTIFICATION. Gillette Body Odor Shield Tough Protection Body Wash

CAS NO. A >94.19 % WT >94.19 % VOL SARA 313 NO

cement Masonry Cement Engineered for quality and reliability, Lafarge cements for masonry deliver consistent performance. page 2 Lafarge Cement

SODIUM CARBOXYMETHYL CELLULOSE

SAFETY DATA SHEET WINTERHALTER A81 BLUE ENZYME DRAIN CLEANER

TREATMENT OF PHOSPHATE FERTILIZER PLANT WASTE WATER IN FLORIDA FOR DISCHARGE AND RE USE PURPOSES

EU Safety Data Sheet. Vival NF. Vival NF

Transcription:

Lewatit DW 630 is a strongly basic macroporous anion exchange resin (type I) with beads of uniform size (monodisperse) based on polystyrene. The resin has been thouroughly washed with sulfuric acid and water to assure potable water purity grade. Lewatit DW 630 will not significantly exchange any major water constituents (Cl -, HCO 3-, NO 3- ) because it is loaded with sulfate, which has the highest selectivity among these anions. Therefore the water composition will not be changed except the removal of target imputies. On account of its fast kinetics, high total capacity, good chemical stability, osmotic properties and porosity Lewatit DW 630 is especially applicable for:» removal of natural sulfate and carbonate complexes of uranium from potable-water to rest concentrations safely below 10 ppb» removal of natural organic matter (NOM) such as humic acids, fulvic acids, building blocks, carboxylic acids from potable water According to the German "Liste der Aufbereitungsstoffe und Desinfektionsverfahren gemäß 11 Trinkwasserverordnung", published by the German Environmental Protection Agency (UBA), strongly basic resins are positively listed and therefore specially approved for the removal of uranium from potable water. Lewatit DW 630 is in compliance with the European Resolution ResAP (2004)3 (superseding the former Resolution AP (97)1) with regard to chemicals used for its fabrication as well as the Total Organic Carbon (TOC) release according the AFNOR test T 90-601. When using Lewatit DW 630 to treat drinking water and the aqueous solutions listed above, special care should be given to the initical sterilisation of the technical installation, hygenic storage and filling in of the ion exchange resin as well as the start up procedure. Please refer to the recommended start-up conditions in this data sheet. Any of the resin has to assure sufficiant hygenic conditions as well as a sufficient high level of. Note that insufficient may cause higher leakage levels of trace impurities in the next cycle as well as shortened cycle times. The special properties of this product can only be fully utilized if the technology and process used correspond to the current state-of-the -art. Further advice in this matter can be obtained from Lanxess, Business Unit Ion Exchange Resins. Previous Edition: 2011-05-12 1/5

General Description Ionic form as shipped sulfate Functional group * quaternary amine, type I Matrix* crosslinked polystyrene Structure macroporous Appearance beige, opaque * can also be referred to as styren-divinylbenzene-copolymer with trialkyl-amin-groups Physical and Chemical Properties metric units Uniformity Coefficient* max. 1.1 Mean bead size* mm 0.64 (+/- 0.06) Bulk density (+/- 5 %) g/l 640 Density approx. g/ml 1.10 Water retention wt. % 58-64 Total capacity* min. eq/l 1.1 Volume change OH - --> Cl - / SO 4 2- max. vol. % - 16 Stability at ph-range 0-14 Storability of the product max. years 2 Storability temperature range C -20-40 Previous Edition: 2011-05-12 2/5

Recommended Operating Conditions* metric units Operating capacity ** Operating ph-range 6-8 Bed depth min. mm 1000 Specific pressure drop at viscosity 1 mpa*s approx. kpa*h/m 2 0.75 Pressure drop max. kpa 300 Specific velocity operation BV/h 5-50 Linear verlocity backwash (20 C) approx. m/h 4-5 Bed expansion min. vol. % 40 Freeboard backwash vol. % 80-100 Regenerant *** (for NOM-removal) NaCl Counter current level approx. g/l 100-200 Counter current concentration wt. % 8-12 Co current level approx. g/l 150-350 Co current concentration approx. wt. % 8-12 Specific velocity approx. BV/h 5 Specific velocity rinsing approx. BV/h 5 Rinse water requirement approx. BV 20 Regenerant*** (for uranium-removal) H 2 SO 4 Counter current level approx. g/l 250-350 Counter current concentration wt. % 10 Co current level approx. g/l 350-550 Specific velocity approx. BV/h 5 Specific velocity rinsing approx. BV/h 5 Rinse water requirement approx. BV 20 * Operating conditions have to be adjusted according to the requirements of the technical concept of the plant as well as the water composition which is individual in every case. Therefore this data sheet gives ranges for operating parameters and no fixed values. Balancing of the parameters has to be done according to the specific requirements of NOM / uranium removal respectively. Specific know how and intellectual property on this applications has been elaborated within studies of third parties. These specialists should be contacted for detailed information. In any case it should be considered to carry out orienting tests as well as pilot studies to generate data for the design. Previous Edition: 2011-05-12 3/5

** Operating capacity, leakage levels as well as operating time depends on 1) reglementory or technical restrictions in the maximum load of ion exchangers 2) specific volumetric flow rate 3) water composition 4) ph 5) definition of the breakthrough point 6) complexing agents 7) number of columns 8) suspended solids in the feed 9) bed depth 8) level of 9) age of resin and others. Related to 1): The maximum load of ion exchangers with uranium may be restricted by local regulations. The maximum load of NOM is restricted in terms to avoid irreversible fouling but may depend on the type of NOM. Related to 3): Note that the efficiency of uranium removal may depend on the type of anionic complex the uranium is bound in as well as the concentration of competing ions such as sulphate, NOM etc. Note that NOM is a cocktail of very different natural organic matter and strongly depends on the geographic region and the depth of the well. *** Note that to carry out a involves risks. These risks are connected to the potential of bacteria contamination and loss in performance as well as the release of toxic substances in the environment if the is not carried out properly. One way use of the resin can reduce that risk. Note that the level of has a strong impact on the performance of the resin in the following cycle. If and washing is not carried out properly a higher leakage level of the adsorptive in the outlet may occur as well as a shortage in cycle time. Therefore it is strongly recommended to adjust the procedure to the individual requirements. That means the higher is the load of adsorptive on the resin and the higher is the binding force (depending on the nature of the adsorptive) the higher is the required specific dosage rate of regenerant that has to be applied. In any case it is strongly recommended to carefully check leakage levels as well as bacteria count in the outlet of the column before switching the column on stream after is carried out. In some cases can be improved by combining salt and acid or caustic respectively. E.g. the of NOM can be improved by adding amounts of caustic to the regenerant brine. Thereby the caustic content may vary in a range of 2 to 4 %. Note that after applying caustic within the of strongly basic resins the outlet of the resin will be of alkaline ph if the resin tower is not rinsed with a brine solution afterwards. Recommended Start-up Conditions* (in drinking water and food applications only) Specific velocity BV/h 5 Rinse water requirement approx. BV 20 * should also be used after stand by times longer than 3 days Previous Edition: 2011-05-12 4/5

Additional Information & Regulations Safety precautions Strong oxidants, e.g. nitric acid, can cause violent reactions if they come into contact with ion exchange resins. Do not load the resin with uranium above the level that is permitted by the environmental protection agency. Provide continious ventialtion of air around the ion exchange column and prevent accumulation of air inside the filters because it may contains radon (Rd). Always keep uranium loaded resin safely enclosed in vessels. This will prevent alpha-radiation to escape. Do not touch uranium loaded resin with bare hands nor do allow any other direct contact with the skin. Toxicity The safety data sheet must be observed. It contains additional data on product description, transport, storage, handling, safety and ecology. Disposal In the European Community Ion exchange resins have to be disposed, according to the European waste nomenclature which can be accessed on the internet-site of the European Union. The storage, transportation and disposal of uranium loaded resins is subjected to special regulations. Please refer to the local instructions, given by the regional environmental protection agencies. Storage It is recommended to store ion exchange resins at temperatures above the freezing point of water under roof in dry conditions without exposure to direct sunlight. If resin should become frozen, it should not be mechanically handled and left to thaw out gradually at ambient temperature. It must be completely thawed before handling or use. No attempt should be made to accelerate the thawing process. This information and our technical advice whether verbal, in writing or by way of trials are given in good faith but without warranty, and this also applies where proprietary rights of third parties are involved. Our advice does not release you from the obligation to check its validity and to test our products as to their suitability for the intended processes and uses. The application, use and processing of our products and the products manufactured by you on the basis of our technical advice are beyond our control and, therefore, entirely your own responsibility. Our products are sold in accordance with the current version of our General Conditions of Sale and Delivery. Previous Edition: 2011-05-12 5/5

Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289