Bypass Level Indicator BM 26 A



Similar documents
Plastic tube flowmeters Series PT/PS

OPTIMASS 1400 Technical Datasheet

OPTIMASS 6000 Technical Datasheet

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Bypass level indicator With magnetic display Model BNA

Micro Motion Model D and DL Coriolis Flow and Density Meters

SITRANS F flowmeters SITRANS F M

IFC 070 Technical Datasheet

Plastic Flow Meters for gases & liquids, using TROGAMID* & POLYSULFONE Technology

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Threaded Resistance Thermometers Model TR10-D, Miniature Design

Inductive sensor NI10-M18-Y1X-H1141

Variable Area Flowmeters

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Flow switches Series AD/VH

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Liquid Level Limit Switch liquiphant T FTL 20

2.12. page Products for Explosion hazardous Environment

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

The Unique Accelabar Flow Meter

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Electromagnetic Flow Meter

Fluxi 2000/TZ Turbine Gas Meter

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Operating Instructions for Plastic Flow Meter. Model: KSK

Pressure transmitter For general industrial applications Model A-10

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.

How To Use A Flowmeter

Turbine Flow Sensor Series VTR

Electronic Pressure Switch EDS 300

CAPACITIVE LEVEL METERS CLM 36

INSTALLATION AND OPERATING INSTRUCTIONS LEVEL SENSOR

Compact pressure switch Flameproof enclosure Ex d Model PCA

Solenoid Valve Island Type 3965

Technical Information RIA14

Toroidal Conductivity Sensor

Dimensions. LUC-M20 with F12 housing and process connection 2" approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions.

Linear Luminaire with LED Series EXLUX 6402/2

Variable V Area Flowmeter Rotameter The Original

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Safety at a high level!

MTB Load Cell. Globally Approved for Accuracy and Safety. MTB Load Cell

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

EXLUX ECOLUX C-LUX LIGHTING. Explosion Protected Fluorescent Lighting Fixtures for Hazardous and Corrosive Applications

Thermometer in stainless steel with capillary and switch contacts

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Digital inductive conductivity transmitter

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

SITRANS F flowmeters. SITRANS F M System information SITRANS F M electromagnetic flowmeters. 4/12 Siemens FI

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Duct Humidity Transmitter

For Multi-Parameter Meters see mvx

Typical Aluminum GFM Mass Flow Meter

Thermatel Model TA1 Mass Flow Transmitter

API Flanged Safety Relief Valves Series 526 CATALOG

NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Control- and feedback head for integrated mounting on Robolux valves Type 2036

3DLevelScanner II TECHNICAL DATA SHEET

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Colima Visco and Colima Viscorol Magnetic Level Indicators

Floating Switch FTS 20 Füllstandgrenzschalter Level Limit Switch Détecteur de niveau

HLC A1... HLC B1... HLC F1... Data Sheet. Load cells. Special features. B en

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids

Bourdon tube pressure gauge with switch contacts Models PGS23.1x0, stainless steel version

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Microcor Wireless Transmitter (MWT)

Proportional pressure regulators VPPE

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Relative pressure transmitter type 520

Product Data. Model 575 Series Submersible Level Transmitters ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

Order Code for GEA Tuchenhagen VESTA Sterile Valves. Type H_A 2/2 Way Seat Valve

Givare NC-SRS 280 och 880

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Type 3353 Angle Seat Valve

Instruction Manual Differential Pressure Transmitter

Series 240 Type and Type Pneumatic Control Valves Type 3244 Three-way Valve

Sensors. Sensors. All Cylinders. Specifications. Features: Features Type REED HALL EFFECT NPN or PNP. Ø8mm - 125mm

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

OLI. Oil level indicator

SITRANS F flowmeters SITRANS F M. Transmitter MAG 5000/ /32 Siemens FI Overview

3/2-way Solenoid Valve, direct-acting, NC or NO

STX2100. Differential Pressure (Flow) Transmitter. GE Measurement & Control. Models FKC...5. Features

VAD. Variable Area Desuperheaters

Transcription:

KROHNE 05/2003 7.02364.22.00 GR Bypass Level Indicator Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level measuring instruments Communications technology Engineering systems & solutions Switches, counters, displays and recorders Heat metering Pressure and temperature

Bypass-level indicator Simple, rugged design Particularly suitable for use with highly corosive, noxious or flammable substances and ideal for severe operating conditions For Level or Interface measurement Operating principle The BM 26 operates on the principle of communicating vessels. The measuring chamber is connected adjacent to the tank so that the same conditions are obtained in the chamber as those in the tank. The float is equipped with a system of permanent magnets to transmit measured values to the local indicator. The magnet system of the float activates either the magnetic flaps according to the liquid level, or a movable follower magnet in the indicating section of the indicator depending on the method of indication chosen. The column of reversed yellow magnetic flaps, or the vertical position of the follower magnet, indicates the liquid level. Measuring tube for pressures up to 120 bar or 1740 psig and temperatures up to 300 C or 570 F 3 different types of protection (STD, EXI or EXD) Level transducer Standard indicator Flap indicator Limit switches MS 15 or MS 20 (option) Easily read scale for level readings, no power required 2

Special versions /AG down to 40 C or 40 F /TR, /IC/TR down to 200 C or 330 F /IC/TR is insulated. /TR is ready for insulation by customer, please specify length of socket up to the connection flange. Measuring tube Indicator tube with indicator Plexitherm glass Measuring tube Glass wool insulation Plexitherm glass Indicator scale 92 mm (3.62 ) Aluminium cladding 200 mm (7.87 ) 137 mm (5.4 ) Indicating tube with indicator 116 mm (4,6 ) /HR, /IC/HR for temperatures from -200 +300 C or -390 +570 F. /IC/HR is insulated. /HR is ready for insulation by customer, please specify length of socket up to the connection flange. Heating system for measuring tube /B For extreme operating conditions, the measuring tube is fitted with a heating jacket, standard connection Ermeto 12 for hot-water or steam heating. Max. allowable operating pressure of the heating medium is 6 bar or 87 psig. Insulation of the measuring tube is recommended. Section through measuring tube with heating jacket Glass wool insulation Measuring tube Measuring tube Indicator scale Indicator tube Aluminium cladding Indicator tube Aluminium cladding Glass wool insulation 3

The responsibility as to the suitability, intended use and corrosion-resistance of the materials used in their construction rests solely with the purchaser. Technical data Instrument type Measuring range (standard) 0.3... 6 m or 0.98... 19.68 ft Accuracy ± 10 mm or ± 0.4 of measured value Min. product density 0.5 kg/l... 3.0 kg/l or 31.2... 187 lbs/ft 3 Viscosity 5000 mpa s or 3.360 lb/ft s Max. allowable operating pressure at 20 C or 70 F 40 bar or 580 psig; (dependent on material, flange pressure rating Information on higher pressure levels available on request and float pressure resistance) Indicator Standard Linear indicator with cm/m graduation Option Linear scale with inch/feet, % or volume Graduation, as required; flap indicator without scale; flap indicator with scale in cm/m, inch/feet, % or volume graduation, as required Mounting position Vertical Protection (indicator) to EN 60529 IP 68 (equivalent to NEMA 6) Pressure vessel approvals Pressure equipment directive 97/23/EC Electromagnetic compatibility (EMC) EN 50081-1, EN 50082-2 and EN 61326 (1 + 2) Ambient temperature Standard, with flap or bar indicator -20 C... +200 C or 5... +390 F Optional, non- Ex -200 C... +300 C or -325... +570 F Bypass Level Indicator for all options, except those shown in tables below Temperature class Process temperature Ambient temperature range for: T6 T(fluid) 70 C or 160 F -20...+60 C or 4...+140 F T5 T(fluid) 95 C or 205 F -20...+50 C or -4...+120 F T4 T(fluid) 130 C or 265 F -20...+50 C or -4...+120 F T3 T(fluid) 195 C or 380 F -20...+40 C or -4...+105 F Bypass Level Indicator with level transducer PRETOP 5343B transmitter and / or all EXI approved level switches Temperature class Process temperature Ambient temperature range for: T6 T(fluid) 70 C or 160 F -40...+60 C or 40...+140 F T5 T(fluid) 95 C or 205 F -40...+50 C or -40...+120 F T4 T(fluid) 130 C or 265 F -40...+50 C or -40...+120 F T3 T(fluid) 195 C or 380 F -40...+40 C or -40...+105 F Bypass Level Indicator without level transducer or level switch Temperature class Process temperature Ambient temperature T6 T(fluid) 70 C or 160 F -20...+60 C or -4...+140 F T5 T(fluid) 95 C or 205 F -20...+50 C or -4...+120 F T4 T(fluid) 130 C or 265 F -20...+50 C or -4...+120 F T3 T(fluid) 195 C or 380 F -20...+40 C or -4...+105 F Connecting flanges Standard DN 25, PN 40 Form C (to DIN 2656) Option DN 15...DN 50, PN 16 or PN 40 or 1 /2... 2, 150 lbs/rf or 300 lbs/rf Connecting flanges for the heating jacket Screw joint (standard) Ermeto 12; DN 15, PN 40 or 1 /2, 150 lbs/rf or 300 lbs/rf Pipe 12 x 1 mm or 0.47 x 0.04 Information on other standards and pressure ratings supplied on request Materials See "Instrument versions Level transducer ER (reed chain) Current output 4...20 ma Limit switches MS 15; MS 20 Min. and max. contact 4

Instrument versions measuring tube class /C /D /E /F Description Equipped with two lateral connections Equipped with two axial connections Equipped with one axial entry and one bottom lateral exit connection Equipped with one lateral entry and one top axial exit connection Dimensions /C/RR Welding neck flange ~72 (2.83 ) ~X /C/RR Loose (EN-DIN) flange ~72 (2.83 ) ~115 (4.53 ) /C/ATEX Welding neck flange ~75 (2.95 ) ~X /C/B (reheater sub-type C) Loose (EN-DIN) flange ~76 (2.99 ) vent plug G 3/8 ~165 (6.5 ) ~200 (7.87 ) ~200 (7.87 ) ~185 (7.28 ) Ermeto 12 M = Measuring range = L L = max. 6000 (19.68 ft.) M = Measuring range = L L = max. 6000 (19.68 ft.) ~300 (11.81 ) ~300 (11.81 ) L ~300 (11.81 ) L + 304 (11.97 ) L = max. 6000 (19.68 ft.) 197 (7.76 ) Ermeto 12 ~300 (11.81 ) X is not defined drain plug G 3/8 /C/AG (anti-freeze sub-type C) Welding neck flange vent plug G 3/8 115 (453 ) 100 (394 ) /C/IC/TR or /HR TR low, HR high temperature Loose (EN-DIN) flange /D/RR Loose (EN-DIN) flange /D/RR Loose (EN-DIN) flange 165 (6.50 ) ~72 (2.83 ) ~72 (2.83 ) ~300 (~11.81 ) 300 (~11.81 ) L = max. 6000 (19.68 ft) L = max. 4000 (13.12 ft) L = max. 6000 (19.68 ft) Measuring range = L - 480 (18.90 ) L = max. 6000 (19.68 ft) Measuring range = L- 480 (L-18.90 ) 197 (7.8 ) 197 (7.76 ) drain plug G 3/8 30 (1.2 ) 5

/E/RR Welding neck flange /E/RR Loose (EN-DIN) flange /F/RR Welding neck flange /F/RR Loose (EN-DIN) flange ~72 (2.83 ) ~X ~72 (2.83 ) ~115 (4.53 ) ~72 (2.83 ) ~X ~72 (2.83 ) ~115 (4.53 ) Measuring range = L - 300 (13 ) L = max. 6000 (19.86 ft.) ~200 (7.87 ft.) Measuring range = L - 300 (13 ) ~200 (7.87 ) L = max. 6000 (19.86 ft.) ~200 (7.87 ) Measuring range = L - 200 (7.87 ) ~300 (11.61 ) L = max. 6000 (19.68 ft.) Measuring range = L - 200 (7.87 ) ~300 (11.61 ) L = max. 6000 (19.68 ft.) X is not defined Dimensions in mm (inches) Weights Version Weight in kg (for 1 m or 3.28 ft) Weight in lbs (for 1 m or 3.28 ft) /STD 14.5 0.51* 31.96 1.12* /EXD 20.6 0.82* 45.50 1.81* * weight for every additional 100 mm or 3.94 flange spacing Guide tube assembly materials Version Flange Gaskets Measuring tube Material Diameter mm inches Stainless steel Aramide Stainless steel 72 x 2.3 2.83 x 0.091 316Ti (1.4571) (PTFE optional) 316Ti (1.4571) or 316L (1.4404) or 316L (1.4404) 6

Maximum operating conditions (according to Pressure Equipment Directive 97 / 23 / EC) with 316 Ti steel measuring tube Maximum allowable operating pressure, P s bar / psig 45 / 652.7 40 / 580.2 35 / 507.6 30 / 435.1 25 / 362.6 20 / 290.1 15 / 217.6 10 / 145 45 / 672.5 Flange category 1 Flange category 2 Flange category 3 Flange category 4 0-200 C -100 C -20 C +100 C +200 C +300 C /-328 F /-148 F /-4 F /+212 F /+392 F /+572 F Maximum process temperature, T s Flange Categories 1 2 3 4 DN15 PN40 DN50 PN40 DN40 PN40 1/2 ASA 150 lbs DN20 PN40 DN50 PN40 WN DN40 PN40 WN 3/4 ASA 150 lbs DN25 PN40 2 ASA 300 lbs 1 ASA 150 lbs DN15 PN40 WN 1 1 /2 ASA 150 lbs DN20 PN40 WN 2 ASA 150 lbs DN25 PN40 WN 1/2 ASA 300 lbs 3/4 ASA 300 lbs 1 ASA 300 lbs 1 1 /2 ASA 300 lbs with 316 L steel measuring tube Maximum allowable operating pressure, P s bar / psig 45 / 652.7 Flange category 1 40 / 580.2 Flange category 3 35 / 507.6 Flange category 4 30 / 435.1 25 / 362.6 Flange category 5 20 / 290.1 15 / 217.6 10 / 145 45 / 672.5 Flange category 2 0-200 C -100 C -20 C +100 C +150 C +200 C +300 C /-328 F /-148 F /-4 F /+212 F /+300 F /+392 F /+572 F Maximum process temperature, T s Flange Categories 1 2 3 4 5 DN15 PN40 DN25 PN40 DN40 PN40 DN50 PN40 1/2 ASA 150 lbs DN20 PN40 DN25 PN40 WN DN40 PN40 WN DN50 PN40 WN 3/4 ASA 150 lbs DN15 PN40 WN 1 ANSI 300 lbs 1 1 /2 ASA 300 lbs 2 ASA 300 lbs 1 ANSI 150 lbs DN20 PN40 WN 1 1 /2 ASA 150 lbs 1/2 ASA 300 lbs 2 ASA 300 lbs 3/4 ASA 300 lbs 7

Level transducer A choice of three transmitters are available for the. The transmitter is defined by the type of communication used, electronics housing protection, housing material and transmitter module. Version designation Housing protection Housing material Transmitter module ER/STD/AL/D Without (non Ex) AL (Aluminium) PRelevel ER/EXI/AL/D EExia AL (Aluminium) PRelevel ER/EXD/AL/D EExd AL (Aluminium) PRelevel Technical data Module Description PRelevel (PRETOP 5343B) 4...20 ma intrinsically-safe transmitter; Conversion of change in resistance to analogue current signals. Output Measuring error Updating time Power supply Ambient temperature C Ambient temperature F 4...20 ma (limits: 3.8; 23 ma); Scale inversion possible. Max. load R L = (U 8) [Ω] 0.023 ± 0.1% of range 100 ms 8...35 V DC -40...+60 C (T6) -40...+85 C (T4) -40...+140 F (T6) -40...+185 F (T4) Human interface PC with communications interface Loop Link 5905 and configuration software provided on a CD-ROM; Sensor error detection is programmable for different output values; NAMUR NE43 values can be selected directly.; Response time is programmable. Certificates and Approvals Standards EN 50014 and EN 50020; EN 50081-1 and 2; EN 50082-1 and 2 Ex EEx ia IIC T4/T6; ATEX 127088 Maximum power dissipated by the Exd housing 5 W Maximum safety values for Exi applications At 4 20 ma terminal block U i : 28 V I i : 120 ma P i : 0.84 W C i : 1 nf L i : 10 µh 8

Electrical connections Dimensions PRelevel (top view) 4-20mA output terminals 135 (5.31 ) 58 (2.28 ) Springloaded screws (2) 60 (2.36 ) Connections, resistance Internal wiring: Do not touch! 9

Limit switches To signal specific liquid levels, the bypass level indicator can be equipped with 13 different types of limit switch that are clamped to the measuring tube and are adjustable over the whole measuring range. They are actuated by a magnet incorporated into the float. The operating conditions define which limit switches may be used. Housing protection Cut-out power Housing material NAMUR Process temperature conformity STD (Without) LC (Low power cut-out) PC (Polycarbonate / Standard) NN (Non-NAMUR) BT (Low temperature) EXI (EExia) HC (High power cut-out) AL (Aluminium) NO (NAMUR) HT (High temperature) Limit switches for the BM26 A (non-ex) Designation Power cut-out Process temperature Ambient temperature ( C or F) ( C or F) MS20/STD/LC/PC/NN/BT 20 W; 1.5 A; 250 V AC <250 or <480-20...+120 or -5...+245 MS15/STD/LC/PC/NO/BT NAMUR <250 or <480-20...+120 or -5...+245 MS15/STD/LC/AL/NN/HT 20 W; 1.5 A; 250 V AC <300 or <570-20...+120 or -5...+245 MS15/STD/LC/AL/NO/HT NAMUR <300 or <570-20...+120 or -5...+245 MS15/STD/HC/PC/NN/BT Max. 100 W; Min. 3 W; 1.5 A; 250 V AC <250 or <480-20...+120 or -5...+245 MS15/STD/HC/AL/NN/HT Max. 100 W; Min. 3 W; 1.5 A; 250 V AC <300 or <570-20...+120 or -5...+245 Limit switches for the BM26 A (Ex) Designation Power cut-out Process temperature and ambient temperature MS20/EXI/LC/PC/NN/BT 1.5 A Dependant on ATEX temperature class* MS15/EXI/LC/PC/NO/BT NAMUR Dependant on ATEX temperature class* MS15/EXI/LC/AL/NN/HT 1.5 A Dependant on ATEX temperature class* MS15/EXI/LC/AL/NO/HT NAMUR Dependant on ATEX temperature class* MS15/EXD/LC/AL/NN/HT 20 W; 1.5 A; 250 V AC Dependant on ATEX temperature class* MS15/EXD/LC/AL/NO/HT NAMUR Dependant on ATEX temperature class* MS15/EXD/HC/AL/NN/HT Max. 100 W; Min. 3 W; 1.5 A; 250 V AC Dependant on ATEX temperature class* MS 15 EXI * See page 4 for values. MS 15/STD, MS 15/EXI, MS 15/EXD, MS 20/STD, MS 20/EXI The limit switches consist of a reed contact that is actuated directly by the magnet system in the float. Due to its bistable switching characteristic, the switching state is maintained until the float magnet system again activates the limit switch in the opposite direction. Line-side connection of a suitable isolation switching amplifier is recommended. MS 15 EXD MS 20 EXI 10

Technical data Limit switch Max. switching capacity Ambient temperature Process temperature Protection category to EN 60529 Cable entry Housing material Hysteresis Weight MS 15/STD 20 VA; 1.5 A; 250 V AC 20...+120 C or 4...+250 F <250 C or <480 F IP 65 (NEMA 4/4X) PG 13.5 polycarbonate 0 130 g or 0.3 lbs MS 15/EXIa 20 VA; 1.5 A; 250 V AC 20...+120 C or 4...+250 F <250 C or <480 F IP 65 (NEMA 4/4X) PG 13.5 polycarbonate 0 130 g or 0.3 lbs MS 15/EXD 20 VA; 1.5 A; 250 V AC -20...+60 C or 4...+140 F <200 C or <390 F IP 65 (NEMA 4/4X) M 25 x 1.5 aluminium 0 1200 g or 2.6 lbs MS15/*/NAMUR According to NAMUR 19234 * * * * * * * Limit switch Max. switching capacity Ambient temperature Process temperature Protection category to EN 60529 Cable entry Housing material Hysteresis Weight MS 20/STD 20 VA 1.5 A, 250 V AC 20...+120 C or 4...+250 F < 250 C or < 480 F IP 65 (NEMA 4/4X) PG 9 polycarbonate 0 85 g or 0.2 lbs MS 20/EXIa 20 VA 1.5 A, 250 V AC 20...+80 C (T6) or 20...+95 C (T5) 4...+175 F (T6) or 4...+200 F (T5) < 250 C or < 480 F IP 65 (NEMA 4/4X) PG 9 polycarbonate 0 85 g or 0.2 lbs * For these characteristics refer to the other columns in the table above for STD (i.e. non-ex), EXIa or EXD switches depending on which official approval has been selected. Electrical connections MS 15/STD or MS 15/EXI terminals MS 15/EXD terminals 1 Terminals 2 Cable entry fitting PG13.5 MS 20/STD or MS 20/EXI terminals Internal wiring: do not touch! 1 Cable entry fitting PG9 2 Terminal block 3 Blue wire (terminal 1) 4 Black wire (terminal 3) 5 Brown wire (terminal 2) 11

Dimensions MS 15/EXD MS 15/EXD/AL without cable fitting Side view 100 (3.9 ) 46 (1.8 ) MS 15/STD and MS 15/EXI MS 15/STD and MS 15/EXI with PG13.5 fitting Side view 75 (2.9 ) ~48 (1.89 ) 52 (2 ) 64.5 (2.5 ) dia. 100 (3.94 ) 135 (5.3 ) ø100 (3.9 ) ø25 (ø1 ) ~48 (1.89 ) 185 (7.28 ) M20 x 1.5 80 (3.1 ) ~140 (5.51 ) Top view 4 holes ø4.5 (ø0.2 ) 52 (2 ) 100 (3.9 ) MS 20/STD and MS 20/EXI MS 20/STD and /EXI with PG9 fitting and integrated bracket Side view 85 (3.35 ) 48 (1.9 ) ø72 (2.8 ) 5 (0.2 ) KROHNE 51.5 (2.03 ) Ø35.5 (1.4 ) Ø55 (2.17 ) 77 (3.03 ) ~120 (~4.7 ) Dimensions in mm (inches) 12

Floats Select float as a function of the pressure, temperature, and density of the liquid. In addition, the required degree of corrosion resistance and use of the correct magnet system must be considered when selecting materials. Code Float Float Dimension Material options VF06 No. options diameter in mm inches Standard versions without approvals or for use in Ex hazardous zones 1 2 Cylinder 64 x 200 x 0.5 2.52 x 7.87 x 0.02 316Ti (1.4571) or 316L (1.4404) 2 1 Cylinder 64 x 200 x 1.0 2.52 x 7.87 x 0.04 316Ti (1.4571) or 316L (1.4404) 3 3 Cylinder 64 x 208 x 0.6 2.52 x 8.19 x 0.024 titanium 4 4 Cylinder 64 x 208 x 1.0 2.52 x 8.19 x 0.04 titanium 5 2 Cylinder, pressure balanced 64 x 200 x 0.5 2.52 x 7.87 x 0.02 316Ti (1.4571) or 316L (1.4404) 6 3 Cylinder, pressure balanced 64 x 208 x 0.6 2.52 x 8.19 x 0.024 titanium 7 2 Cylinder, adjusted density 64 x 200 x 0.5 2.52 x 7.87 x 0.02 316Ti (1.4571) or 316L (1.4404) 8 1 Cylinder, adjusted density 64 x 200 x 1.0 2.52 x 7.87 x 0.04 316Ti (1.4571) or 316L (1.4404) A 2 Cylinder, low density 64 x 200 x 0.5 2.52 x 7.87 x 0.02 316Ti (1.4571) or 316L (1.4404) B 1 Cylinder, low density 64 x 200 x 1.0 2.52 x 7.87 x 0.04 316Ti (1.4571) or 316L (1.4404) C 3 Cylinder, low density 64 x 208 x 0.6 2.52 x 8.19 x 0.024 titanium D 3 Cylinder, low density 64 x 208 x 1.0 2.52 x 8.19 x 0.04 titanium F 2 Cylinder, density adjusted, low density 64 x 200 x 0.5 2.52 x 7.87 x 0.02 316Ti (1.4571) or 316L (1.4404) G 1 Cylinder, density adjusted, low density 64 x 200 x 1.0 2.52 x 7.87 x 0.04 316Ti (1.4571) or 316L (1.4404) H 2 Cylinder, guided for v. low density 64 x 200 x 0.5 2.52 x 7.87 x 0.02 316Ti (1.4571) or 316L (1.4404) K 1 Cylinder, guided for v. low density 64 x 200 x 1.0 2.52 x 7.87 x 0.04 316Ti (1.4571) or 316L (1.4404) L 3 Cylinder, guided for v. low density 64 x 208 x 0.6 2.52 x 8.19 x 0.024 titanium M 4 Cylinder, guided for v. low density 64 x 208 x 1.0 2.52 x 8.19 x 0.04 titanium R 1 Cylinder, ballasted for interface 64 x 200 x 1.0 2.52 x 7.87 x 0.04 316Ti (1.4571) or 316L (1.4404) S 4 Cylinder, ballasted for interface 64 x 208 x 1.0 2.52 x 8.19 x 0.04 titanium Application limits Density and temperature limits Float Density and temperature limits No. Min. density of product Product temperature min. max. kg/l lbs/ft 3 C F C F /Standard versions without approvals 1 0.82 51.19 200 330 +300 +570 2 0.55 34.34 200 330 +300 +570 3 0.50 31.21 200 330 +300 +570 4 0.60 37.46 200 330 +300 +570 Instruments or approved for use in Ex hazardous zones /ATEX (local indicator with electrical equipment) 1 0.82 51.19 20 4 +100 +210 2 0.55 34.34 20 4 +100 +210 3 0.50 31.21 20 4 +100 +210 4 0.60 37.46 20 4 +100 +210 Operating pressure limits Float Application limits No. Max. allowable operating pressure 20 C or 70 F 100 C or 210 F 200 C or 390 F 300 C or 570 F bar psig bar psig bar psig bar psig Standard versions without approvals 1 55 800 41 600 37 535 32 464 2 23 335 12 175 10 145 9 131 3 23 335 13 188 10 145 8 115 4 55 800 31 450 24 350 19 276 /Ex (local indicator with electrical equipment) 1 55 800 41 600 2 23 335 12 175 3 23 335 13 188 4 55 800 31 450 13

Dimensions Floats-No. 1, 2 (316 L or 316 TL) Floats-No. 3, 4 (Titanium) ø64 (2.52 ) ø64 (2.52 ) N N 200 (7.87 ) S S N N S S a a 208 (8.19 ) where a = 47 mm or 1.85" Dimensions in mm (inches) where a = 48 mm or 1.89" Wall thickness Float Wall thickness 1 1 mm or 0.04 2 0.5 mm or 0.02 3 0.6 mm or 0.024 4 1 mm or 0.04 14

Type code The responsibility as to the suitability, intended use and corrosion-resistance of the materials used in their construction rests solely with the purchaser. Subject to change without notice. BM 26 26 A liquid A level bypass indicator mounted liquid parallel level to the tankindicator Code Level indicator VF06 0 Connection type and material A C / RR / 316 TI lateral / lateral C E / RR /316 TI bottom axial / top lateral G C / RR / 316 L lateral / lateral * K E / RR /316 L bottom axial / top lateral B D / RR / 316 TI axial / axial D F / RR / 316 TI bottom lateral / top axial H D / RR / 316 L axial / axial L F / RR / 316 L bottom lateral / top axial Connection DN PN Connection DN PN Connection DN PN 1 DN 15 PN 40 flange lap joint L DN 25 PN 40 WN flange U 3/4" ANSI 150 lb WN flange 2 DN 20 PN 40 flange lap joint M DN 40 PN 40 WN flange V 1/2" ANSI 300 lb WN flange 3 DN 25 PN 40 flange * lap joint N DN 50 PN 40 flange W 3/4" ANSI 300 lb WN flange 4 DN 40 PN 40 flange lap joint P 1/2" ASA ANSI 150 lb WN flange X 1" ANSI 300 lb WN flange 5 DN 50 PN 40 flange lap joint R 1" ASA AINSI 150 lb WN flange Y 1"1/2 ANSI 300 lb WN flange 6 DN 15 PN 40 WN flange S 1"1/2 ANSI 150 lb WN flange Z 2" ANSI 300 lb flange D DN 20 PN 40 WN flange T 2" ANSI 150 lb WN flange C - C Lenght > 1 m 0 0 m (standard) 4 4 m 1 1 m * 5 5 m 2 2 m 6 6 m 3 3 m C - C Lenght in "mm" 0 0 mm * 4 400 mm 7 700 mm 1 100 mm 5 500 mm 8 800 mm 2 200 mm 6 600 mm A 900 mm 3 300 mm Float Stainles steel floats are according to the material of the device Float 1 0,5 mm *316 TI / 316 L* 15* C 0,6 mm *Titanium*10* low density 2 1 mm *316 TI / 316 L* 15* (standard) * D 1 mm *Titanium*10* low density 3 0,6 mm *Titanium*15* F 0,5 mm *316 TI / 316 L* 15* d.adjusted low density 4 1 mm *Titanium*15* G 1 mm *316 TI / 316 L* 15* d.adjusted low density 5 0,5 mm *316 TI / 316 L* 10* p. balanced H 0,5 mm *316 TI / 316 L* 3* guided float for very low density 6 0,6 mm *Titanium* 15* p. balanced K 1 mm *316 TI / 316 L* 3* guided float for very low density 7 0,5 mm *316 TI / 316 L* 15* d.adjusted L 0,6 mm *Titanium*3* guided float for very low density 8 1 mm *316 TI / 316 L* 15* d.adjusted M 1 mm *Titanium*3* guided float for very low density A 0,5 mm *316 TI / 316 L* 10* low density R 1 mm *316 TI / 316 L* 15* LEST IF B 1 mm *316 TI / 316 L* 10* low density S 1 mm *Titanium*15* LEST IF Flange types 0 standard flanges * 5 large male 8 small female C V13 DIN 2513 1 large tongue 3 small tongue 6 small male A Feder DIN 2512 D R13 DIN 2513 2 large groove 4 small groove 7 large female B Nut DIN 2512 Gaskets type 0 standard gasket (Klingerit) * 1 PTFE gasket Indication / Scale 0 st. Steel scale (m+cm) (index) * 1 feet + inches st.steel scale (index) 2 without scale (index) 3 % st.steel scale (index) 4 volume st. Steel scale (index) 5 without scale (flap) 6 st. Steel scale (m+cm) (flap) 7 feet + inches st.steel scale (flap) 8 % st. Steel scale (flap) A volume st. Steel scale (flap) D without indication Drain Drain Drain 0 without drain 7 DN 15 PN 40 WN flange F 3/4" ANSI 300 WN flange 1 G 3/8" drain * A DN 25 PN 40 WN flange G 1" ANSI 300 WN flange 2 1/2" GAZ B 1/2" ANSI 150 WN flange 4 3/8 " NPT C 3/4" ANSI 150 WN flange 5 1/2" NPT D 1" ANSI 150 WN flange 6 3/4" NPT E 1/2" ANSI 300 WN flange Vent Vent Vent 0 without event 7 DN 15 PN 40 WN flange F 3/4" ANSI 300 WN flange 1 G 3/8" event * A DN 25 PN 40 WN flange G 1" ANSI 300 WN flange 2 1/2" GAZ B 1/2" ANSI 150 WN flange 4 3/8 " NPT C 3/4" ANSI 150 WN flange 5 1/2" NPT D 1" ANSI 150 WN flange 6 3/4" NPT E 1/2" ANSI 300 WN flange Design (low, high temperature, heating) TR, AG, HR, B 0 standard * 3 TR.ANTI-FREEZE LONG CONNECTION (DBG) 4 AG.ANTI-FREEZE (FR) 6 HR H; TEMP INDICATOR ONLY 7 HR H TEMP INDICATOR & LONG CONNECTION K B FLANGE DN15 & LONG CONNECTION N B/HR FLANGE-DN15 LONG CONNECTION Insulation 0 without insulation jacket * 5 with insulation jacket (long nozz Admissible maximum temperature 1-200 C 5 +100 C 2-100 C 6 +195 C 3-20 C 7 +300 C 4 +20 C * Approval 0 Non Ex * 3 EEx ia IIC (1G) T3 T6 1 EEx d IIC (1/2G) T3 T6 2 EEx d IIC (2G) T3 T6 Contact type Contact type Contact type 0 without MS 15 /RE/ STD MS 15 /RE/ ExI * 5 / HC/ PC / NN / BT B / LC/ AL / NO / HT 1 MS 20/ STD / LC/ PC / NN / BT 6 MS 15 /RE/ STD / HC/ AL / NN / HT C MS 15 /RE/ EXD / LC/ AL / NN / HT 2 MS 15/RE/ STD / LC/ PC / NO / BT 7 MS 20/ ExI / LC/ PC / NN / BT D MS 15 /RE/ EXD / LC/ AL / NO / HT 3 MS 15 /RE/ STD / LC/ AL / NN / HT 8 MS 15 /RE/ ExI / LC/ PC / NO / BT E MS 15 /RE/ EXD / LC/ AL / NN / HT 4 MS 15 /RE/ STD / LC/ AL / NO / HT A MS 15 /RE/ ExI / LC/ AL / NN / HT Contact number 0 without * 2 2 switches 1 1 switch 3 3 switches ER Transmitter 0 without ER 4 ER/EXI/AL/D transmitter * (Pr level PRETOP 5343B) 2 ER/STD/AL/D (Pr level PRETOP 5343B) 6 ER/EXD/AL/D (Pr level PRETOP 5343B) 4.5.02 Level indicator Last update: 19.03.03 Material Certificate 0 Without * 2 3.1.b Certificate for pieces under pressure 5 Material conformity certificate Hydraulics Control Certificate 0 Without * 1 2.3. Hydraulics test certificate 2 3.1.B Hydraulics test certificate Certificate for Calibration 0 Without * 1 Adjustment certificate Certificates (miscellaneous) 0 Without * 1 2.1. Certificate of compliance with order 2 Overall dimensions (layout) 3 Tag on Stainless steel plate 20x40 4 2.1. Certificate + overall dimensions (layout) 5 2.1. + Tag on Stainless Steel plate 6 Overall dimensions + Tag on Stainless Steel plate 7 2.1. + Overall dimensions + Tag on SS plate VF06 Complete ordering code * Standard version 15