National Diagnostic Reference Level Fact Sheet



Similar documents
DIAGNOSTIC REFERENCE LEVELS IN MEDICAL IMAGING: REVIEW AND ADDITIONAL ADVICE

RESPONSE BY THE CEO OF ARPANSA TO THE ADVICE ON MEDICAL RADIATION ISSUES from the RADIATION HEALTH AND SAFETY ADVISORY COUNCIL

National reference doses for common radiographic, fluoroscopic and dental X-ray examinations in the UK

ESTIMATING POPULATION DOSES FROM MEDICAL RADIOLOGY

Staff Doses & Practical Radiation Protection in DEXA

Practical exercise: Effective dose estimate in CT

Radiation Exposure of the UK Population from Medical and Dental X-ray Examinations

Analysis of Causes for Reject X-Ray Films as a Quality Assurance Element in Diagnostic Radiology in Jos University Teaching Hospital(JUTH)

The Challenge of CT Dose Records

Patient Exposure Doses During Diagnostic Radiography

Diagnostic Exposure Tracking in the Medical Record

X-Rays Benefits and Risks. Techniques that use x-rays

Assessing Radiation Dose: How to Do It Right

Automated EMR Dose History Extraction and Monitoring

Protection of Pregnant Patients during Diagnostic Medical Exposures to Ionising Radiation

PRACTICAL TIPS IN ENSURING RADIATION SAFETY IN THE USE OF MEDICAL DIAGNOSTIC X-RAY EQUIPMENT

Patient Dose Tracking for Imaging Studies. David E. Hintenlang, Ph.D., DABR University of Florida

University of Colorado Radiology Dose-Risk Smartcard

Computed Tomography Radiation Safety Issues in Ontario

CT: Size Specific Dose Estimate (SSDE): Why We Need Another CT Dose Index. Acknowledgements

Recommendations for a technical quality control program for diagnostic X-ray equipment

Radiologist Assistant Role Delineation

Prepublication Requirements

SOURCES AND EFFECTS OF IONIZING RADIATION

First floor, Main Hospital North Services provided 24/7 365 days per year

Radiation Protection Series

THE ROYAL AUSTRALIAN AND NEW ZEALAND COLLEGE OF RADIOLOGISTS

Parkway College of Nursing and Allied Health School of Nursing and Allied Health. BSc (Hons) Diagnostic Radiography and Imaging Module Synopses

Radiation Safety Issues for Radiologic Technologists

IONISING RADIATION. X-rays: benefit and risk

Radiation and Pregnancy

Implementation of Cone-beam CT imaging for Radiotherapy treatment localisation.

SUMMARY OF CURRENT UK LEGISLATION AND GUIDELINES

Test Request Tip Sheet

Risk of cancer from diagnostic X-rays: estimates for the UK and 14 other countries

Design and Implementation of an Institution-Wide Patient-Specific Radiation Dose

5DGLDWLRQ3URWHFWLRQ *8,'(/,1(621('8&$7,21 $1'75$,1,1*,15$',$7, (&7,21)250(',&$/ (;32685(6 (XURSHDQ&RPPLVVLRQ

Monitoring Patient Radiation Dose in VA. Charles M. Anderson MD, PhD Chief Consultant for Diagnostic Services Veterans Health Administration

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

WHERE IN THE WORLD JILL LIPOTI?

Training in Clinical Radiology

Patient sample criteria for the OPEIR Measures Group are all patients regardless of age, that have a specific CT procedure performed:

Moving Forward What does this mean for the Medical Physicist and the Imaging Community?

2/28/2011. MIPPA overview and CMS requirements. CT accreditation. Today s agenda. About MIPPA. Computed Tomography

What is Radiology and Radiologic Technology?

SUBCHAPTER 22 QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS

OPTIMIZING PATIENT EXPOSURE TO IONIZING RADIATION (OPEIR) MEASURES GROUP OVERVIEW 2015 PQRS OPTIONS FOR MEASURES GROUPS:

Annals of the ICRP ICRP PUBLICATION 121. Radiological Protection in Paediatric Diagnostic and Interventional Radiology. Editor-in-Chief C.H.

Radiation Exposure in X-ray and CT Examinations

REGULATION: QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS N.J.A.C. 7:28-22

Dose Datamed II Collective dose in the Portuguese/European population due to medical exposures. Pedro Teles CTN/IST


Illinois. Accreditation. Requirements. Medical Radiation. Technology

Trainee Resources List available on the Learning Management System (LMS)

Radiology Coding: What Your Group Needs To Know In 2016

NHS Imaging and Radiodiagnostic activity in England. 2012/13 Release. August 2013

COMMUNICATING RADIATION RISKS IN PAEDIATRIC IMAGING

CPT CODE PROCEDURE DESCRIPTION. CT Scans CT HEAD/BRAIN W/O CONTRAST CT HEAD/BRAIN W/ CONTRAST CT HEAD/BRAIN W/O & W/ CONTRAST

DOSES TO EYES AND EXTREMITIES OF MEDICAL STAFF DURING INTERVENTIONAL RADIOLOGY PROCEDURES

Revised Radiation Protection Guidance for Diagnostic and Interventional X-ray Procedures

How To Calculate A Patient Dose In Ct

Use of lead shielding for adult chest CT. patient & radiographer experiences

CT dose reconstruction based on RIS and PACS data

SOP #: Revision #: Current Version Implementation Date: Page #: Page 1 of 10 Last Reviewed/Update Date: Expiration

Rb 82 Cardiac PET Scanning Protocols and Dosimetry. Deborah Tout Nuclear Medicine Department Central Manchester University Hospitals

Radiological protection education and training for healthcare staff and students

Licence prerequisites for operators of diagnostic X-ray apparatus

The AAPM does not endorse any products, manufacturers, or suppliers. Nothing in this publication should be interpreted as implying such endorsement.

Patient-centered CT imaging: New methods for patient-specific optimization 1 of image quality and radiation dose

Recommendations for cross-sectional imaging in cancer management, Second edition

The disclaimer on page 1 is an integral part of this document. Copyright February 23, 2016 by AAPM. All rights reserved.

RADIOLOGY SERVICES. By Dr Lim Eng Kok 1

Gestión global de la dosis en TC. Sistema de registro y gestión

Skeletal Surveys in Suspected Non- Accidental Injury (NAI)

Measuring Patient Exposure in Interventional Radiology

Computed Tomography, Head Or Brain; Without Contrast Material, Followed By Contrast Material(S) And Further Sections

STATE OF NEBRASKA STATUTES RELATING TO MEDICAL RADIOGRAPHY PRACTICE ACT

RADIOLOGY HOUSE STAFF MANUAL

CPT Radiology Codes Requiring Review by AIM Effective 01/01/2016

CT Protocol Optimization over the Range of CT Scanner Types: Recommendations & Misconceptions

Quality Assurance. The selection of the equipment. Equipment Specifications. Medical Exposure Directive 97/43 Euratom. Quality Assurance Programme

Cynthia H. McCollough b) and Michael R. Bruesewitz Department of Radiology, Mayo Clinic College of Medicine, Rochester, Minnesota 55905

The Field. Radiologic technologists take x-rays and administer nonradioactive materials into patients' bloodstreams for diagnostic purposes.

PATIENT PREPARATION FOR RADIOLOGY EXAMINATIONS

Diagnostic CT for Molecular Imaging

PET. Can we afford PET-CT. Positron annihilation. PET-CT scanner. PET detection

Appropriateness in cardiology

MDCT Technology. Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington

Multi-slice Helical CT Scanning of the Chest

CLINICAL PERFORMANCE OBJECTIVES

CT Dose to Patients. CT Dose Reporting Requirements of CA Senate Bill Sources of Ionizing Radiation Exposure (then) 5/3/2011

European Academy of DentoMaxilloFacial Radiology

Regulations, Curriculum, Syllabus ( ) Diploma in Radiology Imaging Technology. Course Guidelines & Framework

Radiologic Technology (RAD, CLE) courses are open only to Radiologic Technology majors.

Pediatric Hospitals Bring Low-dose CT to the Middle East

Exposure to Diagnostic Ionizing Radiation in Sports Medicine: Assessing and Monitoring the Risk

Radiation Protection Series

Cabrillo College Catalog

Crosswalk for Positron Emission Tomography (PET) Imaging Codes G0230 G0030, G0032, G0034, G0036, G0038, G0040, G0042, G0044, G0046

Transcription:

National Diagnostic Reference Level Fact Sheet What is the definition of a Diagnostic Reference Level? A Diagnostic Reference Level (DRL), is defined by the International Commission on Radiological Protection (ICRP) 1, as; a form of investigation level, applied to an easily measured quantity, usually the absorbed dose in air, or tissue-equivalent material at the surface of a simple phantom or a representative patient. The ICRP recommends the establishment of diagnostic reference levels as a tool for optimising the radiation dose delivered to patients in the course of diagnostic and/or therapeutic procedures. The Council of the European Union 2 defines DRLs as; dose levels in medical radiodiagnostic practices or, in the case of radiopharmaceuticals, levels of activity, for typical examinations for groups of standard-sized patients or standard phantoms for broadly defined types of equipment. These levels are expected not to be exceeded for standard procedures when good and normal practice regarding diagnostic and technical performance is applied. The ARPANSA national DRL is the 75 th percentile (third quartile) of the spread of the median 3 doses of common protocols as recorded from data submitted to the National Diagnostic Reference Level Service. A local facility reference level (FRL) is defined as the median value of the spread of doses for common protocols surveyed at the local radiology facility. The development of DRLs will be derived from the ongoing data submitted to the National DRL Service, which it is assumed, have produced images of acceptable diagnostic quality as defined by the reporting specialist. What is the objective of DRLs? The objective of a diagnostic reference level is to help avoid excessive radiation dose to the patient that does not contribute additional clinical information value to the medical imaging task 4. E-mail: info@arpansa.gov.au Web: www.arpansa.gov.au Freecall: 1800 022 333 (a free call from fixed phones in Australia) ABN: 613 211 951 55 PO Box 655, MIRANDA NSW 1490 Phone: +61 2 9541 8333, Fax: +61 2 9541 8314 619 Lower Plenty Road, YALLAMBIE VIC 3085 Phone : +61 3 9433 2211, Fax: +61 3 9432 1835 GPO Box 726, CANBERRA ACT 2601 Phone: 1800 022 333

Typically, diagnostic reference levels are used as investigation levels (i.e. as a quality assurance tool), they are advisory and NOT a dose limit, therefore should not be applied to individual patients. The application of a FRL is for the local imaging facility to establish a reference dose for their common imaging protocols that can be used for internal and external comparison. DRLs can also be used for international comparative dosimetry. What are the applications of DRLs? DRLs, together with an optimisation process, help reduce unnecessary patient doses and the consequent radiation risks. A diagnostic reference level can be used to: improve local, regional, or national distributions of observed doses for a general medical imaging task, by reducing the frequency of unjustified high or low dose values promote a narrower range of doses that represent good practice for a more specific medical imaging task promote an optimum range of doses for a specified medical imaging protocol provide a common dose metric for the comparison of FRLs between facilities, protocols and modalities assess the dose impact of the introduction of new protocols provide compliance with the relevant state and territory regulatory requirements 5. Appropriate local review and action is required when the doses observed are consistently outside the selected diagnostic reference level, unless clinically justified. However this elevated dose with clinical justification should be an exception rather than the norm across multiple DRLs. How are DRLs used? FRLs can be used to: define local facility doses for common procedures compare FRLs with other similar protocols compare with other imaging facilities FRLs compare with regional or national DRLs provide a comparative dose metric for optimisation strategies comply with state and territory regulatory requirements. Page 2 of 10

DRLs are used to: compare against FRLs compare with international DRLs comply with state and territory regulatory requirements. What are the regulatory requirements? State and territory regulatory bodies require implementation of the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA) Code of Practice (RPS 14) 5 which requires the development and application of diagnostic reference levels. The ARPANSA Code of Practice (RPS 14), Section 3.1.8 states that the Responsible Person must establish a program to ensure that radiation doses administered to a patient for diagnostic purposes are: a) Periodically compared with diagnostic reference levels (DRLs) for diagnostic procedures for which DRLs have been established in Australia; and b) If DRLs are consistently exceeded, reviewed to determine whether radiation has been optimised. In addition, the ARPANSA Safety Guide 6, Section 7.8, suggests that as part of the QA program, patient dose surveys are undertaken periodically to establish that the doses are acceptable when compared with published DRLs. The Department of Health & Ageing (DoHA) Diagnostic Imaging Accreditation Scheme (DIAS), the Royal Australian & New Zealand College of Radiology (RANZCR) Quality and Accreditation Program and the Australian College on Healthcare Standards (ACHS) EQuIP 5 Accreditation Standards all require compliance with state and territory regulation which in turn requires compliance with the ARPANSA Code of Practice (RPS.14) 5. What measurement quantities are commonly used? From a practical perspective, the DRL should be expressed as an easily measured patient dose-related quantity for the specified imaging platform, for example, multi-detector computed tomography (MDCT): MDCT examinations volume computed tomography dose index (CTDI vol, mgy) 7,8 and the dose-length product (DLP, mgy.cm) 7,8. New CT scanners in accordance with Australian Standards, AS/NZS 32002.44 9, should display the CTDI vol and/or the DLP on the operator s console after the selection of technique factors and prior to the initiation of x-rays. Average CTDI vol and total DLP should be available at the end of the scan procedure 8. Fluoroscopic examinations dose area product (DAP, mgy.cm 2 ), screening time (sec), number of acquired frames 7,8. Page 3 of 10

General Radiographic examinations (film-screen CR & DR) either entrance skin dose (ESD, mgy) 7 or the dose area product (DAP, mgy.cm 2 ) 8. Mammography the mean glandular dose (MGD, mgy) 7,8. Nuclear Medicine adult reference activity (MBq) 8. Estimating Effective Dose (msv) from DRL assessment As seen above, different imaging modalities have different basic dose metrics. To compare these dose metrics and gain some information on the radiation dose delivered and the consequent population statistical risk it is useful to convert the individual DRL dose metrics into approximate effective dose (ED, msv). MDCT DLP to ED 10 Fluoroscopy & Radiography DAP to ED 11 Nuclear Medicine Activity to ED 12 Mammography MGD to ED 13 It should be noted that these effective dose conversions are to be used with caution. They should not be applied to an individual but rather are statistical estimates of a dose and risk to a population who may receive that dose. Australian National DRLs (NDRL) ARPANSA, in collaboration with other stakeholders, has developed the National DRL Service which facilities can use to compare their doses with the national DRLs and from which dose data will be used to develop and update national DRLs. Due to its significantly higher population dose contribution, the National DRL Service will initially be applied to MDCT. This will be followed by interventional fluoroscopic procedures, nuclear medicine, mammography and general radiography & fluoroscopy. The ARPANSA NDRL project will initially give emphasis to the higher dose modalities. ARPANSA will provide an easy to use tool for all modalities but until these are developed and distributed each facility is encouraged to undertake paper based local surveys to establish their own FRLs as soon as possible. Australian national DRLs for adult and paediatric MDCT are now available and are shown in Tables 1a-c. Page 4 of 10

Table 1a: Australian Adult (15+ years) MDCT DRLs Australian Adult (15+ years) MDCT Diagnostic Reference Levels Adult Protocol DLP (mgy.cm) CTDI vol (mgy) Head 1000 60 Neck 600 30 Chest 450 15 AbdoPelvis 700 15 ChestAbdoPelvis 1200 30 Lumbar Spine 900 40 For more information see Adult DRLs information on ARPANSA s website (http://www.arpansa.gov.au/services/ndrl/adult.cfm) Table 1b: Australian Child (5-14 years) MDCT DRLs Australian Child (5-14 years) MDCT Diagnostic Reference Levels) Child Protocol DLP (mgy.cm) CTDIvol (mgy) Head 600 35 Chest 110 5 AbdoPelvis 390 10 Table 1c: Australian Baby/Infant (0-4 years) MDCT DRLs Australian Baby (0-4 years) MDCT Diagnostic Reference Levels Baby Protocol DLP (mgy.cm) CTDI vol (mgy) Head 470 30 Chest 60 2 AbdoPelvis 170 7 For more information see Paediatric DRLs information on ARPANSA s website (http://www.arpansa.gov.au/services/ndrl/paediatric.cfm) Page 5 of 10

Examples of UK and European DRLs Table 2: UK & EU MDCT DRLs 14 Comparison of Head, Chest, and Abdominal CT Dose Values with DRLs Given in European Guidelines (Table 6) Examination Head CT Mean Value 3 rd -Quartile Value United Kingdom Study (3 rd -Quartile Value) European DRL CTDI w (mgy) 39 47 66 60 DLP (mgy cm) 544 527 787 1050 Chest CT CTDI w (mgy) 9.3 9.5 17 30 DLP (mgy cm) 348 447 488 650 Abdominal CT CTDI w (mgy) 10.4 10.9 19.0 35 DLP (mgy cm) 549 696 472 780 Note: Data are mean and 3 rd quartile values for the examinations performed in the entire patient sample. CTDI w weighted CT dose index. Table 3: Recommended diagnostic reference doses for general radiography for individual radiographs on adult patients 15 Radiograph ESD per radiograph (mgy) DAP per radiograph (Gy cm 2 ) Skull AP/PA 3 - Skull LAT 1.5 - Chest PA 0.2 0.12 Chest LAT 1 - Thoracic spine AP 3.5 - Thoracic spine LAT 10 - Lumbar spine AP 6 1.6 Lumbar spine LAT 14 3 Lumbar spine LSJ 26 3 Abdomen AP 6 3 Pelvis AP 4 3 Note: Adult is defined as a person of average size (70 to 80 kg) Page 6 of 10

Table 4: Recommended diagnostic reference doses for fluoroscopic/ interventional examinations on adult patients 15 Examination DAP per exam (Gy.cm 2 ) Fluoroscopy time per exam (mins) Barium (or water soluble) swallow 11 2.3 Barium meal 13 2.3 Barium follow through 14 2.2 Barium (or water soluble) enema 31 2.7 Small bowel enema 50 10.7 Biliary drainage/intervention 54 17 Femoral angiogram 33 5 Hickman line 4 2.2 Hysterosalpingogram 4 1 IVU 16 - MCU 17 2.7 Nephrostogram 13 4.6 Nephrostomy 19 8.8 Retrograde pyelogram 13 3 Sialogram 1.6 1.6 T-tube cholangiogram 10 2 Venogram (leg) 5 2.3 Coronary angiogram 36 5.6 Oesophageal dilation 16 5.5 Pacemaker implant 27 10.7 Page 7 of 10

Table 5: Recommended fluoroscopic/interventional diagnostic reference doses for complete examinations on paediatric patients 15 Examination Standard age (y) DAP per exam (Gy.cm 2 ) MCU 0 0.4 1 1.0 5 1.0 10 2.1 15 4.7 Barium meal 0 0.7 1 2.0 5 2.0 10 4.5 15 7.2 Barium swallow 0 0.8 1 1.5 5 1.5 10 2.7 15 4.6 Table 6: Recommended diagnostic reference levels for CT examinations (CTDIvol and DLP ) 16 Patient group Scan region CTDI vol (mgy) single slice/ multi slice DLP (mgy.cm) Single slice/ multi slice Adults Brain 55/65 760/930 Abdomen (liver metastases) 13/14 460/470 Abdomen &pelvis (abscess) 13/14 510/560 Chest, abdomen & pelvis (lymphoma staging or follow up) 22/26 760/940 Chest (lung cancer) 10/13 430/580 Chest Hi-res 3/7 80/170 Children 0-1 yr old Head Thorax 30 12 270 200 5 year old Head Thorax 45 13 470 230 10 year old Head Thorax 50 20 620 370 Dose values for adults relate to the 16cm diameter CT dosimetry phantom for examinations of the head and the 32cm diameter CT dosimetry phantom for examinations of the trunk. All dose values for children relate to the 16 cm diameter CT dosimetry phantom. Page 8 of 10

Table 7: Recommended diagnostic reference level for mammography for a typical adult patient For film screen examinations using a grid, the mean glandular dose (MGD) is 2 mgy based on the 4.2 cm acrylic American College of Radiologists phantom 17. Additionally for Digital Mammography, the MGD shall be 1 mgy for 2.0 cm PMMA (2.3 cm 50% adipose, 50% glandular breast) and 4.5 mgy for 6.0 cm PMMA (6.5 cm 50% adipose, 50% glandular breast ) 18 Table 8: Sample Australian nuclear medicine DRLs Procedure Name Nuclide Chemical Form Route of Administration Most Common Activity 19 (Mode) (MBq) Adult Reference Activity 19 (MBq) Bone Scan Tc-99m MDP, HDP iv 800 900 5.1 Myocardial perfusion 2 day Tc-99m MIBI iv 600 900 7.1 stress/rest (stress) Myocardial perfusion 2 day Tc-99m MIBI iv 600 840 7.6 stress/rest (rest) Thyroid Tc-99m pertechnetate iv 200 200 2.6 Lung perfusion Tc-99m MAA iv 200 200 2.2 Renal scan Tc-99m MAG3 iv 300 350 2.5 Effective whole body dose 20 (msv) References 1. Radiological protection and safety in medicine. ICRP Publication 73. Ann ICRP 1996, 26 (2), 1-47. 2. Commission, E., The Health Protection of Individuals Against the Dangers of Ionizing Radiation in Relation to Medical Exposure. L180/22, O. f. O. P. o. E. C., Ed. European Commission: Luxemburg, 1997. 3. Mould, R., Introductory Medical Statistics. 3rd ed.; IoP: Bristol, 1995. 4. IAEA Radiological Protection for Medical Exposure to Ionizing Radiation; IAEA: Vienna, 2002. 5. ARPANSA RPS 14. Code of Practice for Radiation Protection in the Medical Applications of Ionizing Radiation; Australian Radiation Protection & Nuclear Safety Agency: Yallambie, 2008. 6. ARPANSA RPS 14.1 Safety Guide for Radiation Protection in Diagnostic and Interventional Radiology; Australian Radiation Protection & Nuclear Safety Agency: Yallambie, 2008. Page 9 of 10

7. Heggie, J.; Liddell, N.; Maher, K., Applied Imaging Technology. 4th ed.; St Vincent's Hospital: Melbourne, 2001. 8. ICRP, Diagnostic reference levels in medical imaging: review and additional advice. Ann ICRP 2001, 31 (4), 33-52. 9. SAA, Medical Electrical Equipment - Particular Requirements for Safety - X-Ray Equipment for Computed Tomography. In AS/NZS 3200.2.44 Ed 2.1, AS/NZS: Melbourne, 2005. 10. McCullough, C. AAPM Report No. 96: The Measurement, Reporting and Management of Radiation Dose in CT; AAPM: 2008. 11. Commission, E. Guidance on Estimating Population Doses from Medical X-Ray Procedures; European Commission: Chilton, UK, 2008. 12. ICRP, Radiation dose to patients from radiopharmaceuticals. Addendum 3 to ICRP Publication 53. ICRP Publication 106. Approved by the Commission in October 2007. Ann ICRP 2008, 38 (1-2), 1-197. 13. 6. Patient Dosimetry in Mammography. JOURNAL OF THE ICRU 2009, 9 (2), 53-63. 14. Tsapaki, V.; Aldrich, J. E.; Sharma, R.; Staniszewska, M. A.; Krisanachinda, A.; Rehani, M.; Hufton, A.; Triantopoulou, C.; Maniatis, P. N.; Papailiou, J.; Prokop, M., Dose Reduction in CT while Maintaining Diagnostic Confidence: Diagnostic Reference Levels at Routine Head, Chest, and Abdominal CT--IAEA-coordinated Research Project 10.1148/radiol.2403050993. Radiology 2006, 240 (3), 828-834. 15. Hart, D.; M.C., H.; Wall, B. F. Doses to patients from medical x-ray examinations in the UK - 2000 review; NRPB: Chilton, 2002. 16. Shrimpton, P. C.; Hillier, M. C.; Lewis, M. A.; Dunn, M., National survey of doses from CT in the UK: 2003. Br J Radiol 2006, 79 (948), 968-980. 17. Craig, A.; Heggie, J.; McLean, I.; Coakley, A.; Nicoll, J., Recommendations for a mammography quality assurance program [ACPSEM Position Paper]. Australas Phys Eng Sci Med 2001, 24 (3), 107-131. 18. Australia, B. National Accreditation Standards; BreastScreen Australia: Sydney, 2008. 19. Botros, G.; Smart, R. C.; Towson, J. E., Diagnostic reference activities for nuclear medicine procedures in Austrlaia and New Zealand derived from the 2008 survey. ANZ Nuclear Medicine 2009, 40 (4), 2-11. 20. ICRP, Radiation dose to patients from radiopharmaceuticals, Publication 80. In Annals of the ICRP, ICRP: Oxford, UK, 1998; Vol. 80. Updated October 2013 Page 10 of 10