Aberdeen AberNAS 110 RAID Recovery Technical Brief



Similar documents
Storage Solutions Overview. Benefits of iscsi Implementation. Abstract

LSI MegaRAID User s Manual

Intel Matrix Storage Console

SATA RAID SIL 3112 CONTROLLER USER S MANUAL

LSI Software RAID Configuration Utility

Promise FastTrak 100-Lite RAID Controller

PENTEK S TALON 27XX SERIES RECORDING SYSTEMS

Configuring ThinkServer RAID 100 on the TS140 and TS440

RAID configuration and driver installation guide

SBI-7125B-T1 Blade Module RAID Setup Procedure

Intel Rapid Storage Technology

Intel Matrix Storage Manager 8.x

Intel Server Raid Controller. RAID Configuration Utility (RCU)

SATARAID5 Serial ATA RAID5 Management Software

Configuring ThinkServer RAID 100 on the Lenovo TS130

Intel RAID Volume Recovery Procedures

Guide to SATA Hard Disks Installation and RAID Configuration

Chapter 2 Array Configuration [SATA Setup Utility] This chapter explains array configurations using this array controller.

M5281/M5283. Serial ATA and Parallel ATA Host Controller. RAID BIOS/Driver/Utility Manual

Recovery BIOS Update Instructions for Intel Desktop Boards

SATARaid Serial ATA RAID Management Software

HP Embedded SATA RAID Controller

Dell Statistica Statistica Enterprise Installation Instructions

Mylex Online RAID Expansion Enhancement for DACCF Utilities 4.4 and Global Array Manager Part Number D01

RAID OPTION ROM USER MANUAL. Version 1.6

Intel ESB2 SATA RAID Setup Guidelines

Guide to SATA Hard Disks Installation and RAID Configuration

WHITE PAPER. HP Guide to System Recovery and Restore

This user guide describes features that are common to most models. Some features may not be available on your computer.

SATARAID5 Serial ATA RAID5 Management Software. Users Manual

Symantec Backup Exec TM 11d for Windows Servers. Quick Installation Guide

NVIDIA RAID Installation Guide

PROMISE ARRAY MANAGEMENT (PAM) for

TotalShredder USB. User s Guide

Symantec Enterprise Vault Technical Note. Administering the Monitoring database. Windows

ENLTV-FM3. PCI TV Tuner Adapter with FM Radio. User s Guide

5-Bay Raid Sub-System Smart Removable 3.5" SATA Multiple Bay Data Storage Device User's Manual

SATA RAID Function (Only for chipset Sil3132 used) User s Manual

RocketRAID User's Manual. Revision: 1.0 Date: Mar HighPoint Technologies, Inc.

Intel ICH7R/ICH9R/ICH10R HostRAID Setup Guidelines

HP dx5150 RAID Installation and Setup Guide Version Document Part Number:

Symantec Backup Exec 2010 R2. Quick Installation Guide

Guide to SATA Hard Disks Installation and RAID Configuration

Symantec Backup Exec System Recovery Exchange Retrieve Option User's Guide

UTC3100 and 3170 POS RAID Information

Microsoft BackOffice Small Business Server 4.5 Installation Instructions for Compaq Prosignia and ProLiant Servers

Copy Tool For Dynamics CRM 2013

AMD RAID Installation Guide

AMD RAID Installation Guide

Remote PC Guide Series - Volume 2a

formerly Help Desk Authority Upgrade Guide

SiS S-ATA User s Manual. Quick User s Guide. Version 0.1

The SATA II PCIe RAID is an ultra high-speed two channel Serial ATA Generation II RAID controller for use in PCI Express enabled systems.

HP ProtectTools Embedded Security Guide

How To Run Qqripper On A Cd Or Mp3 Player (For Pc)

StarPort iscsi and ATA-over-Ethernet Initiator: Using Mirror (RAID1) disk device

This chapter explains how to update device drivers and apply hotfix.

AMD RAID Installation Guide

Onboard-RAID. Onboard-RAID supports striping (RAID 0), mirroring (RAID 1), striping/mirroring (RAID 0+1), or spanning (JBOD) operation, respectively.

Serial ATA RAID PCI. User's Manual

White Paper A New RAID Configuration for Rimage Professional 5410N and Producer IV Systems November 2012

Digipass Plug-In for IAS. IAS Plug-In IAS. Microsoft's Internet Authentication Service. Installation Guide

46xx_47xx_1546_1547 RAID Recovery/Set Up Instructions

Serial ATA 4-Channel RAID Quick Installation Guide

MultiOne. Getting started

Total Disaster Recovery in Clustered Storage Servers

Ultra ATA 133 RAID PCI Pro

4 Backing Up and Restoring System Software

RAID 1(+0): breaking mirrors and rebuilding drives

Dotworkz NVR Series User Manual. Rev 1.26

VERITAS Backup Exec 9.1 for Windows Servers Quick Installation Guide

VERITAS Backup Exec TM 10.0 for Windows Servers

SATA150 TX2PLUS, TX4 QUICK START GUIDE. Version 1.2

VIA / JMicron RAID Installation Guide

Configuring ThinkServer RAID 100 on the Lenovo TS430

SATA II PCIe RAID Quick Installation Guide

Adaptec SAS RAID Configuration and the Windows OS Installation Instructions

MegaRAID RAID Controller Configuration Software Guide

SiS964 RAID. User s Manual. Edition. Trademarks V1.0 P/N: U49-M2-0E

Upgrade Guide. CA Application Delivery Analysis 10.1

MANAGING DISK STORAGE

SiS 180 S-ATA User s Manual. Quick User s Guide. Version 0.1

Symantec Backup Exec System Recovery Granular Restore Option User's Guide

Symantec AntiVirus Corporate Edition Patch Update

Microsoft File and Print Service Failover Using Microsoft Cluster Server

Remote PC Guide Series - Volume 2b

Areas Covered. Chapter 1 Features (Overview/Note) Chapter 2 How to Use WebBIOS. Chapter 3 Installing Global Array Manager (GAM)

Corsair Flash Voyager USB 2.0 Flash Drive UFD Utility User s Manual

BrightStor ARCserve Backup for Windows

HP Point of Sale (POS) Peripherals Configuration Guide ap5000 VFD Windows (non-opos)

Beckhoff onboard SATA-RAID

Monetra Payment Software

AXIS Camera Station Quick Installation Guide

HP Embedded SATA RAID Controller

How To Set Up A Raid On A Hard Disk Drive On A Sasa S964 (Sasa) (Sasa) (Ios) (Tos) And Sas964 S9 64 (Sata) (

RAID User Guide. Edition. Trademarks V1.0 P/N: C51GME0-00

WebBIOS Configuration Utility Guide

SiS964/SiS180 SATA w/ RAID User s Manual. Quick User s Guide. Version 0.3

Transcription:

Aberdeen AberNAS 110 RAID Recovery Technical Brief Aberdeen LLC. Charles D. Jansen Published: February 2005 Abstract This Aberdeen technical brief provides a quick step by step procedure required to repair failed disk redundancy in the event of a hard drive failure. Aberdeen AberNAS 110 RAID Recovery

No part of this manual, including the products and software described in it, may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language in any form or by any means, except documentation kept by the purchaser for backup purposes, without the express written permission of ABERDEEN LLC. ("ABERDEEN"). ABERDEEN PROVIDES THIS MANUAL "AS IS" WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OR CONDITIONS OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL ABERDEEN, ITS DIRECTORS, OFFICERS, EMPLOYEES OR AGENTS BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES (INCLUDING DAMAGES FOR LOSS OF PROFITS, LOSS OF BUSINESS, LOSS OF USE OR DATA, INTERRUPTION OF BUSINESS AND THE LIKE), EVEN IF ABERDEEN HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES ARISING FROM ANY DEFECT OR ERROR IN THIS MANUAL OR PRODUCT. Products and corporate names appearing in this manual may or may not be registered trademarks or copyrights of their respective companies, and are used only for identification or explanation and to the owners' benefit, without intent to infringe. - Aberdeen, Stirling, AberNAS, Backup Monster, TeraBuster, TeraStorus, and XDAS are trademarks of Aberdeen LLC. - Intel, Pentium, and Xeon are trademarks of Intel Corporation. - Microsoft, Windows, and Windows NT are trademarks of Microsoft Corporation. For previous or updated manuals, BIOS, drivers, or product release information, contact ABERDEEN at http://www.aberdeeninc.com or through any of the means indicated on the following pages. SPECIFICATIONS AND INFORMATION CONTAINED IN THIS MANUAL ARE FURNISHED FOR INFORMATIONAL USE ONLY, AND ARE SUBJECT TO CHANGE AT ANY TIME WITHOUT NOTICE, AND SHOULD NOT BE CONSTRUED AS A COMMITMENT BY ABERDEEN. ABERDEEN ASSUMES NO RESPONSIBILITY OR LIABILITY FOR ANY ERRORS OR INACCURACIES THAT MAY APPEAR IN THIS MANUAL, INCLUDING THE PRODUCTS AND SOFTWARE DESCRIBED IN IT. Copyright 2004 ABERDEEN LLC. All Rights Reserved. Aberdeen AberNAS 110 RAID Recovery 2

The Aberdeen AberNAS 110 has been designed to sustain the failure of a single 250MB hard disk drive. In the event of a hard drive failure, the system will remain online. Once the system is available for maintenance, the following steps should be performed to return the system to its optimal state in a minimum amount of time. Below is the default logical disk configuration for the Aberdeen AberNAS 110: Aberdeen AberNAS 110 Physical Drive Locations: Aberdeen AberNAS 110 RAID Recovery 3

In the event of a disk failure, the following warning message will appear in the system tray: Windows FT Orphaning A disk that is part of a fault tolerant volume can no longer be accessed. To check the nature of the disk failure it is necessary to open the Disk Administrator. To do this, right click on My Computer, click Manage, then select Disk Management. The following screen will be appear: By viewing the disk manager we can tell that Disk 0 has disappeared and has been replaced with a missing disk that shows as offline. As shown at the beginning of this guide, Disk 0 is the left-most disk in the system chassis. In order to repair this type of failure and bring the server back to a healthy state, the following procedure must be applied: 1. Remove the failed drive and replace with a new, formatted hard drive of the same specifications. This step can be performed while Windows is running or while the system is powered down. 2. Restart the system, log back into Windows, and return to Disk Administrator. Note If the new drive contains existing information, the system will not boot to Windows. In this case, restart the system, and follow the instructions for formatting drives located at the end of this guide. It is extremely important to make sure the replacement drive is at least the same size as the failed drive. If it is NOT, you will NOT be able to successfully rebuild the failed array to a healthy state. Aberdeen AberNAS 110 RAID Recovery 4

Once in disk management you will be prompted immediately to initialize and covert the new disk so it can be used in the RAID. Make sure to convert to dynamic disk. The following screen will appear: 3. Click Next to select the drive to Initialize, then click Next to select and convert the new disk. Aberdeen AberNAS 110 RAID Recovery 5

After initializing and converting the new drive, your screen should now appear as shown below: The next step is to remove the mirror from the missing drive so the mirror can be re-established using the new drive. 4. Right click on the C: partition of the missing drive and select Remove Mirror. 5. You will be prompted to select which drive to remove from the mirror. Select the Missing drive, then click Remove Mirror. You will be prompted to confirm removal, click Yes to continue. The following screen will be displayed: Aberdeen AberNAS 110 RAID Recovery 6

After removing the mirror a warning message will be displayed informing that the boot file could not be updated. This is normal. 6. Click Ok to continue. Windows disk manager will now display the following screen: 7. Right click on C: on Disk 1 and click Add Mirror. The following screen will appear: Aberdeen AberNAS 110 RAID Recovery 7

8. Click Add Mirror. The mirror will then begin to rebuild/resynch. Rebuilding should take no longer than a minute or two. Your screen will look like the following: Once completed, the system drives should now appear healthy on disks 0 and 1 as shown below: Aberdeen AberNAS 110 RAID Recovery 8

9. The next step is to right click on any of the blue Failed Redundancy volumes and select Repair Volume. The following window will appear: 10. Click Ok to select the new drive to join into the redundant array. This will initialize the rebuild process which will take some time to complete. However, the server can still be accessed and utilized while in the rebuild state. Disk manager should now appear as shown below: Note It is important not to power down the machine while the rebuild is taking place or it will automatically restart from the beginning once the server is rebooted. Aberdeen AberNAS 110 RAID Recovery 9

11. Finally, now that there are no redundant volumes associated with the missing drive, it can be removed. To do this, simply right click on the missing drive and select Remove Disk. Once the resynching has concluded, Disk Manager should appear exactly like the default disk configuration shown at the beginning of this guide. Note The Aberdeen AberNAS 110 takes approximately 3hr40min to complete the rebuild. The server should not be powered off during the rebuild period. In the event the server is powered down, rebuild will automatically resume from the beginning once the server is brought back online. Aberdeen AberNAS 110 RAID Recovery 10

Formatting Drives The Aberdeen AberNAS 110 utilizes a Microsoft Windows based RAID 5 redundant volume configuration. The system is designed to remain online even during the failure of one of the disk drives. Once a drive has failed, it is important to replace the disk as soon as possible to avoid the risk of multiple drive failures which would result in total system failure. The following procedure should be followed to properly prepare a used hard drive for use as a replacement in the Aberdeen AberNAS 110. When a system drive failure occurs the failed drive should be replaced with a suitable NEW replacement. The drive should be received in a sealed anti-static protective bag. In the event a new drive is unavailable, a used drive of the same specifications can be used so long as it is formatted properly. To format a hard drive using the Aberdeen AberNAS 110 perform the following steps: 1. Restart the server. 2. During POST (Power-On Self Test) wait for the following screen to be displayed: 3. When the above screen appears, press and hold the CTRL key then press the A key. The Adaptec RAID Configuration Utility will be initiated and the following screen will appear: 4. Select Disk Utilities as shown above using the arrow keys and press Enter. Note Failure to properly format a drive for use in the Aberdeen AberNAS 110 can prevent the system from booting. When planning system maintenance to replace a failed drive, allow approximately 70mins to complete the format. Aberdeen AberNAS 110 RAID Recovery 11

The following screen is now displayed: 5. Select Format Disk as shown then press Enter. 6. You will be prompted to confirm the format, select Yes then begin the format by pressing Enter. 7. The format process will begin. When complete, press ESC and confirm to exit utility and restart the system by selecting Yes. Aberdeen AberNAS 110 RAID Recovery 12

Getting Help Aberdeen, LLC. 9130 Norwalk Blvd. Santa Fe Springs, CA 90670 (800) 552-6868 (Choose Option 2) Please have the following information available before contacting Aberdeen Technical Support: - Customer ID (Found under Customer field on Invoice) - Technical Support Case Number (If Applicable) - Product Model Names and Numbers - Product Serial Numbers - Operating System type and version - Detailed description of error codes and messages Having this information available will help improve the level of service you receive from Aberdeen technical support. Helpful information can also be found by visiting the Aberdeen technical support website: http://www.aberdeeninc.com/abcatg/support.htm Aberdeen AberNAS 110 RAID Recovery 13