Impact of medical waste incineration in the atmospheric PCDD/F levels of Porto, Portugal

Similar documents
ATMOSPHERIC EMISSIONS FROM GAS FIRED HOME HEATING APPLIANCES

Sludge Treatment Facility Stack Gas Monitoring Report February 2016

Technique of Monitoring Dioxins in Flue Gas from MSW Incinerators using Dioxin Precursor Analyzer

Examination syllabuses for Manual Stack emissions monitoring. Environment Agency Version 9 January 2015

PHARMACEUTICAL AND CHEMICAL WASTE MANAGEMENT

Official Journal of the European Communities

Waste Incineration Plants

AN EFFECTIVE THERMAL TECHNOLOGY FOR THE DETOXIFICATION OF THE MSW FLY ASH

Treatment and Disposal Technologies for Medical Wastes in Developing Countries

Holcim EMR List of EN Standards and VDI Guidelines usable for Discontinuous Measurements in Cement Plants

Norit Activated Carbon for Purification of Edible Oils

EMISSIONS OF AIR POLLUTANTS IN THE UK, 1970 TO 2014

4.09 THE IMPORTANCE OF BUILDING DOWNWASH IN ASSESSING THE NEED TO HEIGHTEN STACKS OF EXISTING SMALL AND MEDIUM SIZED INDUSTRIES

IT3 01 Conference, Philadelphia, PA, May 14-18, 2001

Waste to Energy in Düsseldorf. for a clean city.

Estimated emissions and CO2 savings deriving from adoption of in-place recycling techniques for road pavements

In this experiment, we will use three properties to identify a liquid substance: solubility, density and boiling point..

Use of Fly ash from KKAB, for sealing of landfills

Revealing the costs of air pollution from industrial facilities in Europe a summary for policymakers

Use of Substitute Fuels in Large Combustion Plants (LCPs)

WASTES INCINERATION PLANTS

IWR Integrated Waste Recycling. Integrated System for treatment and recycling of Municipal Solid Waste

Comparison of Different Methods for Determining Methane Emission from Waste Disposal Sites in Thailand

Site Identification No.: AAO Application No.:

Comparison of PM10 and SO 2 Concentrations in the Cities Located at the Mediterranean Coast of Turkey

GUIDELINES FOR PROCESSING AND USING REFUSE DERIVED FUEL (RDF) IN CEMENT INDUSTRY

Iron and Steel Manufacturing

SULFUR RECOVERY UNIT. Thermal Oxidizer

Nu G Medical Waste System Technology (Pyrolysis / Thermal Decomposition)

voestalpine Stahl, Linz, Austria Maximized Emission Reduction Of Sintering SIMETAL CIS MEROS plant Metals Technologies

Marsa Thermal Treatment Facility Yearly Emissions Statement

MICROORGANIC POLLUTANTS: ACTION NEEDED TO SIMPLIFY THEIR ANALYSIS

Catalytic Dioxin/Furan Removal from Flue Gas Streams

Stack Sampling Stack sampling or source sampling

Manual stack emission monitoring Performance standard for organisations. Environment Agency November 2011 Version 7.2

Improving Energy Efficiency through Biomass Drying

1.3 Properties of Coal

ENVIRONMENTAL EXTERNALITIES FROM LANDFILL DISPOSAL AND INCINERATION OF WASTE

A clean energy solution from cradle to grave

HEAT RECOVERY OPTIONS FOR DRYERS AND OXIDIZERS

How To Run A Power Plant In Celje

Waste a source of energy. Regional Solid Waste Management Plan Review: Engaging solutions for tomorrow. Incineration. Incineration

Developments and trends shaping the future for Waste-to- Energy technology suppliers

Costs of air pollution from European industrial facilities an updated assessment

Iowa Fine Particulate Monitoring Network Design Values Iowa DNR Ambient Air Monitoring Group

CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2

Handbook for Emission Measurements for Macedonia

A car air-conditioning system based on an absorption refrigeration cycle using energy from exhaust gas of an internal combustion engine

SIX REASONS TO DRY BIOGAS To A LOW DEWPOINT BEFORE COMBUSTION IN A CHP ENGINE STEVEN SCOTT MARKET DEVELOPMENT MANAGER ALTERNATIVE ENERGIES

Pollution and health impacts of waste incinerators

JASE-world Waste to Energy Sub WG Masanori Tsukahara Hitachi Zosen Corporation

Legrand's environmental commitments

Municipal waste management in Austria

Plasma Arc Technology

Calculation of Liquefied Natural Gas (LNG) Burning Rates

SLMA Meeting. Boiler MACT and Related Rules. Atlanta, GA March 2, Martin Rollins, P. E. H. M. Rollins Company, Inc. Gulfport, Mississippi

Form 0.5 chair, 2805 and 2806

Application Note 12: TrendView Recorders Continuous Emissions Monitoring

Module 5: Combustion Technology. Lecture 34: Calculation of calorific value of fuels

Healthcare Waste Management Training

SOLAR WATER PURIFICATION WITH THE HELP OF CSP TECHNOLOGY

GAS EMISSIONS OF YAKACIK CLOSED SOLID WASTE LANDFILL SITE IN ISTANBUL

Waste-to-Energy s contribution to Resource & Energy Efficiency

INCINERATION PLANTS. Hazardous waste incineration Wastewater incineration Sewage sludge incineration. A Bayer and LANXESS company

The Minimum Ignition Energy of Coal Dust in an Oxygen Enriched Atmosphere

Welcome to the Understanding Dissolved Oxygen learning module. This section provides information on the following topics:

Experience with co-combustion of biomass and waste in coal-fired power plants

Modern Sand Reclamation Technologies for Economy, Environment Friendliness and Energy Efficiency

Waste to Energy. Anders Damgaard. Thanks to Jiri Hyks and Thomas H Christensen DTU for some slides

Energy From Waste or Waste-to-Energy. Pyromex. The Solution to Multiple Energy & Environmental Issues James Pfeiffer, CEM

PREPARATION FOR CHEMISTRY LAB: COMBUSTION

A discussion of condensate removal systems for clarifier and thickener drives for water and wastewater facilities.

Trends in Solid Waste Management: Issues, Challenges and Opportunities

Biomass pellets production with industrial and agro-industrial wastes

Optimization Design for Sulfur Dioxide Flow Monitoring Apparatus in Thermal Power Plants Hao-wei Hu 1, a, Xue Yang 1, b and Xiao-wei Song 1, c

6 CONSIDERATION OF ALTERNATIVES

Calculate Available Heat for Natural Gas Fuel For Industrial Heating Equipment and Boilers

3 - Atomic Absorption Spectroscopy

Questions and answers about energy from waste facilities

Municipal Authorities Best Practice in Engaging. Packaging and Food Waste. March 2014

Country specific notes on municipal waste data

Lecture 35: Atmosphere in Furnaces

POROUS BURNER - A New Approach to Infrared

1. Theoretical background

Legrand's environmental commitments

This fact sheet provides an overview of options for managing solid

BIO MEDICAL WASTE MANAGEMENT

Policy on Monitoring of Stack Emissions to Air at EPA Licensed Sites

Long-Term Demonstration of CO2 Recovery from the Flue Gas of a Coal-Fired Power Station

Reduction in air pollution using the basa njengo magogo method and the applicability to low-smoke fuels

Recommendations Regarding the Handling of Norit GL 50 in Flue Gas Clean up Systems

Medical waste management in Korea *

Biomass Boiler House Best Practices. Irene Coyle & Fernando Preto CanmetENERGY

Hazardous and Regulated Waste Management Plan Purpose

Description of Thermal Oxidizers

Arecibo Resource Recovery Project

This method has been adopted in many communities in the United States and Europe

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

Beware of Exaggerated Claims and Uncertified Manufacturers Ratings Regarding Commercial Boiler Efficiency

ARP Food Industry, Portugal

Transcription:

Science of the Total Environment 362 (2006) 157 165 www.elsevier.com/locate/scitotenv Impact of medical waste incineration in the atmospheric PCDD/F levels of Porto, Portugal M. Coutinho a, *, M. Pereira a, R. Rodrigues a, C. Borrego a,b a IDAD-Instituto do Ambiente e Desenvolvimento, Campus Universitário, 3810-193 AVEIRO, Portugal b Departamento de Ambiente e Ordenamento, Universidade de Aveiro, 38910-193 AVEIRO, Portugal Received 17 March 2005; accepted 16 June 2005 Available online 10 August 2005 Abstract As a consequence of a monitoring program of a new municipal waste incinerator initiated in 1998, a large data-base of dioxin and furan concentrations in the atmosphere of the metropolitan area of Porto, in northern Portugal, has been collected. The existence of this data coincides with the shutdown in January 2001 of two medical waste incinerators that were under operation in the inner city of Porto. Dioxin emissions from these facilities were measured indicating emissions 100 to 1000 times larger than recent European Union directive limits. Data show that the shutdown of these two units had a clear effect on the improvement of air quality in the region that was observed either on the overall level of dioxins and furans or as in subtle alterations of the homolog pattern of these compounds in the atmosphere. D 2005 Elsevier B.V. All rights reserved. Keywords: Waste; Incineration; Dioxins; Furans; Ambient air 1. Introduction In 1997 the European Union (EU) concluded a first study for the development of an inventory of atmospheric emissions of polychlorinated dibenzo-pdioxins (PCDD) and polychlorinated dibenzo furans (PCDF) in Europe (Quass et al., 1997). According to that study, which reflected the emission situation for the period 1993 1995, substantial data gaps still existed for a number of potential and relevant * Corresponding author. Tel.: +351234400800; fax: +351234382876. E-mail address: msc@idad.ua.pt (M. Coutinho). dioxin emission sources. This study recommended additional research work that should focus on the development of measurement programs for all types of waste incinerators and diverse facilities in the metal production sector. Moreover, several countries had gathered little or none of their own relevant information up to that date. The lack of information was particularly noticeable in Portugal where no information about dioxin emissions measurements was available, despite the publication of a preliminary emission inventory for the metropolitan area of Porto (Coutinho et al., 1998) based on the application of emission factors. 0048-9697/$ - see front matter D 2005 Elsevier B.V. All rights reserved. doi:10.1016/j.scitotenv.2005.06.012

158 M. Coutinho et al. / Science of the Total Environment 362 (2006) 157 165 As a consequence of this situation a second stage of the project was launched with the aim of reducing these uncertainties and to bcatalyseq the implementation of corresponding national actions (Quass et al., 2004). The main objectives of this project were to carry out case studies on emission sources and, consequently, update the emission inventories on the basis of these results. Under this large framework, a monitoring program consisting of 13 samples covering the sectors of medical waste incineration, steel production and secondary aluminium and copper recovery was performed in Portugal within two measurement campaigns organized in December 1999 (Coutinho et al., 2000) and April 2000 (Coutinho et al., 2001a). Parallel to this work on emissions, the construction of a municipal solid waste (MSW) incinerator in the region of Porto in 1998 led to the development of an external environmental monitoring program (Coutinho et al., 2001b). This monitoring program includes the regular sampling of heavy metals, and dioxins and furans in several matrices such as ambient air, water, sediments, soil, vegetables and diary products. This monitoring program is in regular operation currently. Since the beginning of this program a total of 93 ambient air samples were collected in several sites in the vicinity of the MSW incinerator providing an extensive characterization of dioxins and furans atmospheric levels in the metropolitan area of Porto, as well as information about the temporal trend of the atmospheric concentration of these compounds. In the first trimester of 2001 the emission scenario in Porto experienced a significant reduction in the level of dioxins due to the shutdown of two medical waste incinerators responsible for an important fraction of the dioxin input to the atmosphere. This paper analyzes the reduction of the atmospheric levels of dioxins in the region of Porto as a consequence of the cessation of the operations of these facilities. 2. Experimental section 2.1. Emissions The cooled probe method (EN 1948 1 of December 1996) was followed for the sampling procedure. In the application of this method, a partial volume of the flue gas is extracted via a glass tube from the flue gas duct and conducted into the collection system. The glass probe is mounted centrally in a water cooled titanium probe. A rapid cool down of the gaseous sample is achieved using cooling water. The collection system consists of a cartridge with two polyurethane foam absorption units. Polyurethane is a special sorbent with proven efficiency for the separation of organic substances. These foam units are installed on both sides of a plane filter with high collection efficiency. Connected to this absorption unit is an equipment group consisting of a drying tower, a gas pump and a gas volume meter. A sampling standard is added to the condensate flask before sampling. The flow of the sampled gas stream is adjusted to isokinetic conditions at the sampling nozzle. 2.2. Ambient air monitoring The sampling apparatus for PCDDs/PCDFs in ambient air was carried out according to the German guideline VDI 3498 Part 2, 2002. The sampling apparatus consisted of a filter system, a mast, a suction pump, a gas volumeter and a timer. Particulate matter in the air was collected on a glass fiber filter. Filterpassing matter was collected on a polyurethane (PU) foam absorption filter. To monitor the effectiveness of sampling, a second polyurethane foam sampling unit was connected downstream. The reference volume is the volume of air that is drawn through the sampling device and measured with a gas volumeter during the sampling period (72 h). The PCDD/PCDF samples which were deposited on the glass fibre filter and absorbed in the PU foam, were extracted and cleaned up from interfering components in a multistage separation process. They were quantified by gas chromatography/mass spectrometry, according to the German guideline VDI 3498 Part 1, 2002. 3. Results and discussion 3.1. Medical waste incinerators emissions The city of Porto is the second largest city of Portugal with a metropolitan population of about

M. Coutinho et al. / Science of the Total Environment 362 (2006) 157 165 159 1,500,000 inhabitants. This region is served by two large general hospitals: The Hospital of S. João (HSJ) and the Hospital of S. António (HSA). These two hospitals have had their own facilities for the incineration of medical waste since the 1970s. Medical waste refers to any waste generated from the health care industry, including hospitals and medical laboratories. One of the major characteristics of medical waste is its heterogeneity. It includes anatomical waste, pathological waste, infectious waste, hazardous waste and other waste. Consequently atmospheric emissions caused by the incineration of medical waste depend not only on the incineration conditions, but also on the waste characteristics. Medical wastes must be classified according to their source, typology and risks factors associated with their handling, storage and ultimate disposal. Portuguese legislation classifies the waste stream produced through medical activities in four groups: Group I similar to municipal wastes (MunW); Group II non-hazardous medical waste that do not require specific treatment and can be considered similar to MunW; Group III medical waste with biological risks that must be pre-treated before elimination as MunW; and Group IV specific medical wastes with compulsory incineration. A recent work indicates that when waste collection follows usual segregation practices of HSA, Group I + II wastes Fig. 1. Map of the region of Porto with indication of sampling sites (1 to 6), medical waste incinerators (HSA and HSJ) as well as municipal solid waste incinerator (MSW).

160 M. Coutinho et al. / Science of the Total Environment 362 (2006) 157 165 represent 49% of the total, Group III 41% and Group IV only 10% on a weighted basis (Alvim-Ferraz and Afonso, 2003). Incineration has been the most widely used treatment technology for the disposal of medical wastes. The major advantages are a significant reduction in the volume of material, and destruction of pathogens and hazardous organics. The main disadvantage is that incineration may emit trace amounts of unwanted pollutants such as PCDD and PCDF, usually in cities due to the typical location of hospitals (Lee and Huffman, 1996). That was the case of HSA and HSJ (see Fig. 1) that are located near two universities in Porto. In 1999, stack PCDD/PCDF emission measurements were performed at these two hospitals incinerators in Porto (Coutinho et al., 2000). At the time, both hospitals were equipped with controlled air incinerators with two stage combustion. Waste was fed into the primary combustion chamber, which was operated with less than the full amount of air required for complete combustion. Under these sub-stoichiometric conditions, the waste was dried, heated and pyrolized. The non-volatile combustible portion was burned in the primary chamber. Moisture, volatiles and combustion gases from the primary chamber were mixed with air prior to entering the secondary combustion chamber where these combustible gases were ignited by a burner located near the entrance. Flue gases exiting the secondary chamber were sent directly to the stack (12 m high at HSJ and 30 m high at HSA) without any additional treatment. In the case of HSJ a heat recovery system was installed. Emission data collected in 1999 from the two incinerators is summarized in Table 1. In order to analyze the results obtained, it is important to note that the EU emission limit value for new waste incinerators is 0.1 I-TEQ ng m 3. Emissions resulting from the operation of these units were clearly above the EU limits: the emissions at HSA were 10 to 60 times higher than the limit, and HSJ emissions were three orders of magnitude above the limit. Taking into consideration the amount of waste burned during the sampling, it was possible to calculate an emission factor for PCDD/F that ranged between 30 and 200 I-TEQ Ag of PCDD/F per ton of waste incinerated. The HSA incinerator operated for a few hours, two days per week, for a total of about 416 h per year. On the other hand, HSJ collected waste from other hospitals and was in operation about 4800 h per year. As a consequence of this difference of the operational regime between the two incinerators, HSJ stands out as the major emitter of dioxins and furans to the atmosphere of Porto with a total of about 200 to 400 mg I-TEQ per year. These results confirm previous studies published about medical waste treatment in Portugal that concluded that the incineration of medical waste without atmospheric pollutants control did not obey the legal emission limits, even when correct practices of operation and maintenance were used (Alvim-Ferraz and Pontes, 2000). 2,3,7,8-substituted PCDD/F congener profiles for the hospital waste incinerator emission samples are represented in Fig. 2. Dioxin congeners are depicted in dark grey and furans in light grey. Less chlorinated congeners are represented to the left of each set of emission bar graphs. Table 1 PCDD/F emission data obtained in São João Hospital (HSJ) and S. António Hospital (HSA) waste incinerators Sample HSJ141299 HSJ151299 HSA071299 HSA171299 Stack temperature (8C) 185 191 435 430 Water content (%) 10.4 7.6 5.2 4.7 Oxygen (dry %) 14.8 14.0 17.6 16.3 Velocity (m/s) 1.8 1.5 12.0 13.2 Flow (dry Nm 3 /h) 835 701 7330 8200 Concentration at 11% O 2 (I-TEQ ng/m 3 ) 125 102 1.03 5.88 Incinerated waste during sampling (kg) 2634 2796 485 700 Emission factor (I-TEQ Ag/ton) 179 100 27 192 Hours of operation per year 4800 4800 416 416 Yearly emission (I-TEQ mg/yr) 380 220 1.4 9.3

M. Coutinho et al. / Science of the Total Environment 362 (2006) 157 165 161 25% Congener/Sum 2,3,7,8(PCDD/F) 20% 15% 10% 5% 0% SJ141299 SJ151299 SA071299 SA171299 Fig. 2. 2,3,7,8-substituted congener profiles. Congeners are represented in the following order: 2,3,7,8-TCDD; 1,2,3,7,8-PentaCDD; 1,2,3,4,7,8- HexCDD; 1,2,3,6,7,8-HexCDD; 1,2,3,7,8,9-HexCDD; 1,2,3,4,6,7,8-HepCDD; OCDD; 2,3,7,8-TCDF; 1,2,3,7,8-PentaCDF; 2,3,4,7,8-PentaCDF; 1,2,3,4,7,8-HexCDF, 1,2,3,6,7,8-HexCDF; 1,2,3,7,8,9-HexCDF; 2,3,4,6,7,8-HexCDF; 1,2,3,4,6,7,8-HepCDF; 1,2,3,4,7,8,9-HepCDF; OCDF. Analysis of the individual congener pattern for the hospital waste incinerators samples shows a very strong homogeneity among the four samples. Remember that measurements were performed in two hospitals, with and without heat recovery. Congener profiles represented in Fig. 2 show a relative balance between dioxins and furans and the excess of the more chlorinated species. As a consequence of the implementation of the national Strategic Plan for Medical Wastes (IR, 1998) these two incineration facilities were shutdown in January 2001. Since that time medical wastes are incinerated in a treatment facility with appropriate air pollutants control devices. 3.2. Ambient air An ambient air monitoring program for the MSW incinerator in the region of Porto (see Fig. 1) was designed with the main objective of evaluating the effects on the surrounding area. In 1998, a set of two monitoring sites were selected in the suburbs of Porto (sites 1 and 3), in a radius of a few kilometres from the MSW complex, followed by another two in 1999 (sites 2 and 6). In August 1999, sampling ceased at the closest site (#3) to the facility. One of the sites located in downtown Porto (#6) was discontinued in February 2000. Regular monitoring continued at sites 1 and 2, with samples taken every 3 months until the present. Sites 4 and 5 were used during a specific field campaign organized in February 2002. Through the summer of 2004, more than 90 ambient air samples of PCDD/PCDF were taken during this 5-year period. In this paper, in the computation of the total I- TEQ concentration calculated using I-TEF (International Toxicity Equivalency Factor), for those congeners below the detection limit the actual concentration was assumed to be half the detection limit. The median concentration occurring during entire sampling period was of 130 fg I-TEQ m 3, with frequent samples above 400 fg I-TEQ m 3. Another ambient air monitoring program, developed in the Lisbon region, Portugal and described elsewhere (Coutinho et al., 2004), revealed a range of concentrations from 7.5 to 152 fg I-TEQ m 3. Fig. 3 illustrates several statistical parameters for all these samples and the ones collected in the Porto region. This figure shows that the 25th percentile for the Porto region (69 fg I-TEQ m 3 ) is higher than the 75th percentile for the Lisbon region (41 fg I-TEQ m 3 ). The difference between the group of samples from Porto and from Lisbon cannot be explained by any natural characteristic of these regions. Both monitoring programs include territory with typical suburban

162 M. Coutinho et al. / Science of the Total Environment 362 (2006) 157 165 Concentration (I-TEQ fg/m 3 ) 450 400 350 300 250 200 150 100 50 0 P90 P75 P25 P10 Oporto region (n=89) Lisbon region (n=42) Fig. 3. PCDD/PCDF statistical parameters: mean ( n ), percentile 10 (P10), 25 (P25), 75 (P75) and 90 (P90). Determined for ambient air samples collected in the regions of Porto and Lisbon. land-use belonging to the metropolitan areas of Porto and Lisbon. According to Lohmann and Jones (1998), PCDD/F concentrations for the total sum of TEQ are typically as follows: remote b10 fg I-TEQ m 3 ); rural ~20 50 fg I-TEQ m 3 ); and urban/industrial ~100 400 fg I- TEQ m 3. Concentrations measured in Lisbon are comparable to those found in rural and uncontaminated urban areas: 83% of PCDD/PCDF concentrations in this region range from 10 to 100 fg I-TEQ m 3. On the other hand, in Porto 77% of samples collected are in the 40 to 400 fg I-TEQ m 3 range, approximately four times higher than the levels for the Lisbon region. Levels measured in Porto are consistent with data published for Barcelona, on the NE coast of the Iberian Peninsula, where the reported maximum concentrations were in the range of 600 to 800 fg I-TEQ m 3 (Abad et al., 2004). Several studies performed in different airsheds (Hippelein et al., 1996; Fiedler et al., 1997) have shown that atmospheric levels of PCDD/PCDF follow a typical seasonal variation characterized by higher concentrations during winter when compared with typical summer concentrations. This seasonal pattern 450 Average concentration PCDD+PCDF (fg I-TEQ/m 3 ) 400 350 300 250 200 150 100 50 0 1998 1998/99 1999 1999/00 2000 2000/01 2001 2001/02 2002 2002/03 2003 2003/04 2004 Fig. 4. Seasonal average atmospheric levels of PCDD/F in the region of Porto including standard deviation bars and trend line for winter (continuous) and summer (dashed) samples.

M. Coutinho et al. / Science of the Total Environment 362 (2006) 157 165 163 Factor 2 (6,2 %) 1,0 0,9 0,8 0,7 0,6 0,5 0,4 win98_99 win99_00 sum99 sum98 with MWI sum00 without MWI win02_03 win03_04 win01_02 sum04 sum03 sum02 win00_01 0,3 0,3 0,4 0,5 0,6 0,7 0,8 0,9 1,0 Factor 1 (89,4 %) Fig. 5. Principal component plot for the ambient air PCDD/F samples collected in the region of Porto. can be explained by the intensification of the operation of diverse combustion sources during winter as well as by the more frequent presence of thermal inversion layers at the surface level during winter. These inversions cause a significant increase of atmospheric concentrations when pollutants are emitted at low levels below the thermal inversion layer. To determine the seasonal behaviour of PCDD/F, two periods were considered, April September and October March, referred to as bsummerq and bwinterq in all figures presented in this paper. Fig. 4 shows the average PCDD/F concentration, expressed in I-TEQ, considering summer and winter periods in the region of Porto. Prior to the winter of 2001 02, winter levels in Porto were approximately 3 to 4 times higher than summer levels. After then it is possible to observe a significant decrease of mean concentrations of atmospheric PCDD/PCDF. The mean value (37 fg I-TEQ m 3 ) and concentration range (13 42 fg I-TEQ m 3 ) for 2002 are the lowest recorded in this region, followed by 2003 (mean: 50 fg I- TEQ m 3, range: 9,8 172 fg I-TEQ m 3 ). The decrease of atmospheric concentrations of PCDD/F was more evident during winter time: PCDD/F levels showed a reduction by a factor of 2, from average levels typically above 300 fg I-TEQ m 3 to values between 150 and 200 fg. I-TEQ m 3. For a more statistically significant approach, principal component analysis (PCA) was performed considering all seasonal periods since the beginning of PCDD/PCDF ambient air sampling in Porto. All data 0,30 0,25 Homolog Fraction 0,20 0,15 0,10 0,05 0,00 4D 5D 6D 7D 8D 4F 5F 6F 7F 8F Fig. 6. PCDD/F homologue profiles for the two clusters of ambient air samples identified through principal component analysis: before shutdown of MWI (black) and after (gray).

164 M. Coutinho et al. / Science of the Total Environment 362 (2006) 157 165 were normalized so that [PCDD] +[PCDF] = 1, and average homologue contributions from each season, expressed as I-TEQ m 3, were used as inputs to the cluster analysis. PCA shows that data is subdivided in two clusters separating samples obtained before and after the shutdown of the medical waste incinerators (Fig. 5). Homologue average profiles for each cluster were analysed in order to derive further indications on the possible dioxin sources (Fig. 6). The hepta- and octa- CDD and tetra-cdf have accounted for at least half of the total concentrations for the last few years. Since the shutdown of the medical waste incinerators, there has been an increased contribution of about 50% from the tetra-chlorinated species of furans, and a decrease to approximately one third of the hexa-chlorinated dioxins. Shutdown of the Hospital Waste incinerator at the beginning of 2001 resulted in a redistribution of homologue fractions, with an apparent increase in tetra-cdf species. This relative increase helped to identify the contribution of one of the main sources of these congeners: the ferrous and non-ferrous metal industries operating in the region. A major seasonal pollution source of atmospheric PCDD/PCDF levels in the region may also be household wood burning for heating in winter. Burning woods at low temperatures, with low burning efficiency, plus burning of wood treated with chlorinated phenols (added as a preservative) woods may increase PCDD/PCDF emissions (Dyke et al., 1997). 4. Conclusions Interpretation of temporal trends of atmospheric dioxin levels in the region of Porto shows the contribution that medical waste incinerators, without any air pollution control devices, might have in the deterioration of air quality in urban areas. The shutdown of two medical waste incinerators in Porto, Portugal caused a decrease in the atmospheric concentrations of dioxins and furans of about 50% in both winter and summer. Dioxins levels measured currently during the winter of approximately 200 fg I-TEQ m 3 reflect a relatively typical situation for a large urban area such as Porto. Nevertheless, these concentrations are significantly higher than levels monitored in a similar monitoring program in Lisbon and consequently deserve further research. Acknowledgements The authors gratefully acknowledge blipor Sistema Intermunicipal de Tratamento de Lixos da Região do PortoQ for the promotion and financial support to the external air quality monitoring program. The authors acknowledge the careful review of this paper in draft form by Thomas S. Davis. References Abad E, Caixach J, Rivera J, Gustems L, Massagué G, Puig O. Temporal trends of PCDDs/PCDFs in ambient air in Catalonia (Spain). Sci Total Environ 2004;334 335:279 85. Alvim-Ferraz M, Cardoso J, Pontes S. Concentration of atmospheric pollutants in gaseous emissions of medical waste incinerators. J Air Waste Manage Assoc 2000;50:131 6. Alvim-Ferraz M, Afonso S. Incineration of different types of medical wastes: emission factors for gaseous emissions. Atmos Environ 2003;37:5414 22. Coutinho M, Borrego C, Ferreira C. Atmospheric emissions of PCDD/PCDF and heavy metals in the Oporto urban area. Organohalog Compd 1998;36:153 6. Coutinho M, Rodrigues R, Duwel U, Papke O, Borrego C, Schroder H. The DG ENV European dioxin emission inventory Stage II: characterization of the emissions of 2 hospital waste incinerators and a steel mill plant in Portugal. Organohalog Compd 2000;46:287 90. Coutinho M, Rodrigues R, Duwel U, Papke O, Borrego C, Schroder H. The DG ENV European dioxin emission inventory Stage II: characterization of the emissions of secondary aluminum and copper production plants and a hospital waste incinerator in Portugal, Measuring Dioxin Emissions. VDI-Ber 2001a;1585: 161 6. Coutinho M, Ferreira J, Gomes P, Mata P, Borrego C. Atmospheric baseline levels of PCDD and PCDF in the region of Oporto. Chemosphere 2001b;43:497 500. Coutinho M, Mata P, Pereira M, Borrego C. Níveis ambientais e biológicos de dioxinas e furanos em Portugal (Environmental and biological levels of dioxins and furans in Portugal), Revista da Faculdade de Medicina de Lisboa, Série III 2004;9(4):285 91. Dyke P, Coleman P, James R. Dioxins in ambient air, bonfire night 1994. Chemosphere 1997;34:1191 201. Fiedler H, Lau C, Cooper K, Andersson R, Hjelt M, Rappe C, et al. PCDD/PCDF in the atmosphere of southern Mississippi, USA. Organohalog Compd 1997;33:122 7. Hippelein M, Kaupp H, Dorr G, Hutzinger O. Baseline contamination assessment for a new resource recovery facility in Germany: Part

M. Coutinho et al. / Science of the Total Environment 362 (2006) 157 165 165 II. Atmospheric concentrations of PCDD/F. Chemosphere 1996;32(8):1605 16. IR. Plano Estratégico dos Resíduos Sólidos Hospitalares (Strategic Plan for Medical Wastes). Instituto dos Resíduos. Lisbon7 Ministery of Environment; 1998. Lee C, Huffman G. Review: medical waste management/incineration. J Hazard Mater 1996;48:1 30. Lohmann R, Jones K. Dioxins and furans in air and deposition: a review of levels, behaviour and processes. Sci Total Environ 1998;219(1):53 81. Quass U, Ferman M, Broker G. Identification of relevant industrial sources of dioxins and furans in Europe. Final report of the DG Environment European Dioxin Emission Inventory Project Stage I, vol. 43. LUA-Materialen. Quass U, Ferman M, Broker G. The European dioxin emission inventory project final results. Chemosphere 2004;54: 1319 27.