How To Use A Power Pro Elite With An Alternating Pressure Mattress

Similar documents
Operation Manual FOR & 14030

Med-Aire 8 Alternating Pressure Mattress Replacement System With Low Air Loss

Dual Cushion User Manual. Specialist Suppliers to the Healthcare Industry

Digital Photo Picture Frame. Operation Manual

How To Use A Power Supply Unit (Upu)

PLEASE READ ALL INSTRUCTIONS BEFORE USE AND SAVE A COPY FOR FUTURE REFERENCE!

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

19 LED Tube Controller ORDERCODE 41003

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

National- Spencer Inc.

Anti-decubitus Mattress 418E 516E - 820Z User's manual

INTELLIHEAT HEATED UNDERBLANKET

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

VACUUM CLEANER INSTRUCTION MANUAL

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

User Installation Guide

2-SLICE COOL TOUCH TOASTER

Heated throw User manual

- 2 - IMPORTANT SAFETY REMINDERS

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

User s Manual AURORA 1.2K/2.2K

Daily use. Never use alcohol or other solvents to clean any part of the loudspeakers!

CARING FOR YOUR WATER HEATER

OPL BASIC. Dosing System for Professional Laundry machines. Contents

MIC-WKT and MIC-WKT-IR

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

CHAPTER 4 UTILITY SYSTEMS ELECTRICAL. Utility Systems Electrical. Main Panel

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

IMPORTANT SAFETY RULES TO FOLLOW

Active Pressure Relieving Systems

San josé OWNER S MANUAL

15GAL STEEL OIL DRAIN WITH 110V PUMP

OPERATOR S MANUAL Vet Pump

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

PowlVac Vacuum Integrity Tester

TABLE OF CONTENTS QUICK START... 1 DIAGRAM OF THE DIGITAL PHOTO FRAME... 2 KEYPAD BUTTON FUNCTIONS... 3 REMOTE CONTROL FUNCTIONS..

Support Cleaning Apparatus. Operation, Cleaning, & Safety Manual

Safety, Operation and Maintenance Manual with Parts List

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS

MBSAW. Meat Cutting Band Saw With Meat Grinder Assembly & Operating Instructions

User Manual. Instructions for installing the Sure Stitch on the Next Generation Quilting Frame. Parts Included:

Technical Update TAA.TU Rev. 1

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

CAR SEAT/ STROLLER INSTRUCTION MANUAL

English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...

Samuel Shorty Bunk Bed

Wooden Shipping Crate is Available to Protect Your UV Light Source. 11 X " diameter tubes 120 VAC Amps Watts

pc-6 humantouch.com use & care manual

Ultra-Violet Products Ltd 2066 W 11th Street, Upland, CA Unit 1, Trinity Hall Farm Estate

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

Ultrasonic support removal tank

COLOR TFT LCD MONITOR. User Manual

WATERBED ASSEMBLY INSTRUCTIONS

400 Amp Rechargeable Jump Start System RAC-HP082


SERVICE MANUAL RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS. Troubleshooting Guide and Instructions for Service

PATIENT GUIDE. Care and Maintenance Drainage Frequency: Max. Drainage Volume: Dressing Option: Clinician s Signature: Every drainage Weekly

3 WATT LED SPOTLIGHT Model No. SLM

Portable Air Conditioner

OWNER S MANUAL DRAINVAC ATOMIK PRINTED APRIL

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

BTH360-S Bluetooth Stereo Headset Specifications & User's Guide

SBC90. Abrasive Blast Cabinet Assembly & Operating Instructions

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

4 in 1 Air Compressor

ROUTER TABLE INSERT ASSEMBLY AND OPERATING INSTRUCTIONS

Use and Care Manual. Model CPA12KH AIR CONDITIONER

PA 03 basic device TECHNICAL DATA. English

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

When you switch off your system, or mute the sound, the red indicator light appears immediately, indicating that the subwoofer is not in use.

Please read and keep these instructions. Run water through your machine before first use

M V Intake Manifold INSTALLATION INSTRUCTIONS

PAL to NTSC (NTSC to PAL) Converter with 19 inch Rack (CDM-640AR)

High Efficiency Vaporizing System and Highly Durable Heaters Ensure 25% Increased Output.

ClearView 100. Instruction Manual

WSD130 SOLDERING STATION

Operations Manual Blast Chiller

Replacing the Gateway M675 Keyboard

WINDOW ROOM AIR CONDITIONER

floater imports DF169 ECO AIR COOLER EVAPORATIVE AIR COOLER WITH IONIZER USER S MANUAL

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

Dehumidifier Users manual. For Models: DH45S DH65S

INSTALLATION MANUAL 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS

UV100A Ultraviolet Air Treatment System

Cooling system components, removing and installing

User s Manual MXH-BT600E BLUETOOTH WIRELESS HEADPHONE

Split Type Room Air Conditioner. KSWM units

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

4.3-inch Back-Up Camera

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Replacing the Gateway M320 Keyboard

350, 500, 650 and 1000 MODELS

SMD Rework Station TABLE OF CONTENTS

USER S MANUAL HSC-24A

Transcription:

- Power Pro Elite - Alternating Pressure Mattress System with True Low Air Loss User Manual 1 Blake Medical Distribution 38 Lincoln Street Hamilton, ON L8L 7L5 Ph.: 1-866-662-3459 Fax: 905-560-1342

Warning: - Connect the Master Control unit to a proper power source. - Don t use the system in the presence of any flammable gases (such as Anesthetic agents) - Keep the pump and mattress away from sources of liquid or open flame - Keep the mattress away from sharp objects - Do not place a heating device close to the mattress system Caution - Use the mattress under the physician s instruction - Re-positioning the patient is still necessary when using this system - The control unit can only be repaired by an authorized distributor - Do not drop the control unit - Use the mattress system in cooperation with side rails if possible - Do not store the system in direct sunlight or extreme cold conditions Master Control Unit Features - Alternating time can be adjusted from 5 mins to 95 mins. Or the caregiver can even select the Static Mode that will stop the Alternate mode and provide only True Low Air Loss Therapy. Once in Low air Loss, the caregiver can select Pulsate mode to add a pulsating effect - Auto firm mode provides a uniformed firmness for nursing procedure - Power failures produce an audio and visual alarm for added safety - 10 settings for Soft/Firm Comfort control - Double insulation provides for quiet operation - Foot board mounting rack provides the convenience of placement 2

Instruction for Proper Use - Remove the existing mattress from the bed frame - Replace the standard mattress with the Power-Pro True Low Air Loss with Alternating Pressure Mattress and make sure the hose connectors are placed at the foot of the bed - Secure the straps beneath the mattress to the bed frame - Hang the Master Control Unit on the foot-board of the bed frame. Attach the hose connectors to the socket on the left panel of the Master Control Unit. Be careful with the colour matching between the connectors and socket. (black connectors to black socket, red connector to red socket) - Ensure the air hoses are not obstructed in the mattress. Zip the top cover to the mattress - Carefully plug the power cord into a properly grounded power source. Turn on the master mechanical power switch on the right side panel. The STANDBY LED should illuminate - Push the STANDBY/OPERATE button on the front panel. The OPERATE LED light should now be illuminated and the Master Control Unit should start to operate - Push the AUTO FIRM button for fast inflation. Allow 4-7 minutes for full inflation - After the mattress is fully inflated, the caregiver can now transfer the patient onto the mattress. Push AUTO FIRM again to release the fast inflation mode. (Note: The Control unit can inflate the mattress with the patient lying on the inflating mattress) - Static Mode: Push the Mode button to select Static Mode and adjust the Comfort Control by pressing the SOFT/FIRM button to achieve the maximum patient comfort. During this mode the system provides True Low Air Loss Therapy. Perform a hand check by placing a hand under the patient s buttock between the air cells and bed frame - Dynamic Mode: Push the Mode button to select Alternate mode and enable the 2-1 alternating pressure - Alternation time can be adjusted by the CYCLE button. (If Static mode is selected the time window will not be illuminated) - Pulsate Mode*: Push the Mode button to select Pulsate mode and enable the pulsating Low air Loss. When selected, this feature allows the Low Air Loss to pulsate every 5 minutes - The Master Control Unit is equipped with a failure alarm. This function will generate an audible/visual alarm to remind the caregiver of a main power failure. The alarm can be disabled by pushing the Alarm Reset Button on the front panel - The Master Control Unit is also equipped with an auto-locking feature. All pulsate function keys will be automatically disabled if the control panel has not been touched for 3-minutes after powered on. When auto-locking has been engaged, the LOCK OUT button will illuminate. - Unlocking the control panel is easy. Simply press the LOCK OUT button on the control for 3-5 seconds * Optional feature available 3

Cleaning Power Pro Elite The mattress should be cleaned on the bed weekly using a damp soft cloth and mild detergent. If top sheet (top cover) or base (bottom cover) becomes excessively soiled, put on clean gloves, plastic gown and eye protection before removing top sheet or base and clean or dispose of the cover according to standard procedures for contaminated waste. Replace with clean covers. Covers can be washed in a washing machine. (Never use phenol based cleaning solutions. Tumble drying is not recommended) Storage and Care Master Control Unit Check the power cord and plug for abrasions and excessive wear Plug in the unit and verify that air flows from the hose connection ports Place in plastic bag for storage Mattress Replacement System Check the air manifold for kinks or breaks. Replace if necessary Twist open the CPR plug at the head of the mattress and disconnect the air feed tubes. All of the air will be expelled. Starting at the head of the mattress roll towards the foot of the bed. Use the base mounted straps to secure for containment Place the system in a plastic bag for storage Symptom Inspection Procedure Possible Solutions The air is flowing out from the control unit but the mattress is not inflating. 1. Is the power source correct? Improper voltage may cause the pump to function abnormally and damage the control unit 2. Do the air tubes allow smooth airflow? Is an air tube kinked? 3. Is there any air leakage from the air cells? 4. Is there any air leakage from air tube between mattress and control unit? 5. Has the air tube been connected properly? 1. Use power regulator 2. Adjust the air tubes to enable smooth air flow 3. Replace with newer air tubes 4. Replace with new air tubes 5. Re-connect the air tubes. The Control Unit is not working Some air cells have abnormal low air pressure while the air pressure for other air cells is normal. 4 1.Check the power cord and the power voltage 2. Check the fuse 1. Is the connection between air cells and the manifold kinked? 2. Is there any air leakage from the air cells? 1. Use a power regulator 2. Replace with a new fuse 1. Adjust the connection between cells and manifold 2. Replace with a new air cell

Operation - Place mattress on bed frame and secure to frame with the four corner straps - Plug in the control unit and place at foot of bed using the foldaway hanger brackets - Connect the three hose unit into black manifold and single hose to single part on the left side of the pump - The power switch is located on the right side of the pump - For rapid inflation push the operate button and then auto firm button. Pushing auto firm again will default into static mode - Once inflated push alternate button for Low Air Loss Therapy Mode - Push alternate button for Low Air Loss/Alternating Air Therapy Mode - Push Pulsate mode for Pulsating Low Air Loss Therapy Mode - Select cycle time: 5-95 minutes per cycle - Select patient comfort setting: Based on average patient weight - In emergency: Twist CPR Release Valve in either direction to release air from mattress Pump Weight Recommendations 5