illustra NAP-25 Columns For the purification of oligonucleotides and small DNA fragments. Desalting and buffer exchange.

Similar documents
illustra MicroSpin G-25 Columns

Page finder. 1. Legal Handling Safety warnings and precautions Storage Expiry 4

UniFlux 10: hollow fiber conversion kit ( ) installation instruction

RESOURCE Q, 1 ml and 6 ml RESOURCE S, 1 ml and 6 ml

Amersham High Molecular Weight Calibration Kit for native electrophoresis

HiTrap Heparin HP, 1 ml and 5 ml

GE Healthcare. UNICORN 6.x. SQL Server 2008 configuration for UNICORN installations

CU-950 Installation Guide

GE Healthcare. UNICORN 5.2 vs Software Change Description

His GraviTrap. GE Healthcare. Operation

Sterile ReadyToProcess Hollow Fiber Cartridges Instructions for Use

Genomic DNA Clean & Concentrator Catalog Nos. D4010 & D4011

Process-scale purification of monoclonal antibodies polishing using Capto Q

Summary of GE Healthcare's Quality Management System (QMS) Covering BioProcess chromatography media, equipment, software, and spare parts

GE Healthcare Life Sciences. Validation Services. Compliance support through life cycle management

soft ware change description

DeCyder Extended Data Analysis (EDA) Software

How to Download a GE Healthcare License File

Gain efficiency in your process development with ÄKTA avant

illustra puretaq Ready-To-Go PCR Beads

UltraClean PCR Clean-Up Kit

UNICORN. Hardening Guide

GAMP5 - a lifecycle management framework for customized bioprocess solutions

UNICORN MS SQL Server Integration

TIANquick Mini Purification Kit

ZR-96 DNA Sequencing Clean-up Kit Catalog Nos. D4052 & D4053

PCR and Sequencing Reaction Clean-Up Kit (Magnetic Bead System) 50 preps Product #60200

PicoMaxx High Fidelity PCR System

ZR DNA Sequencing Clean-up Kit

ab Hi-Fi cdna Synthesis Kit

HiTrap Chelating HP, 1 ml and 5 ml

ID kit. imegen Anchovies II. and E. japonicus) DNA detection by. User manual. Anchovies species (E. encrasicolus. sequencing.

Aurora Forensic Sample Clean-up Protocol

ExpressArt Bacterial H-TR cdna synthesis kit. With extreme selectivity against rrnas

UNICORN 7.0 software. Description. gelifesciences.com

ReadyKart Mobile Processing Station Instructions for Use

Instrument services for WAVE Bioreactor systems

ISOLATE II PCR and Gel Kit. Product Manual

GRS Plasmid Purification Kit Transfection Grade GK (2 MaxiPreps)

UNICORN control software

Genomic DNA Extraction Kit INSTRUCTION MANUAL

INSTRUCTION Probemaker

UltraClean Forensic DNA Isolation Kit (Single Prep Format)

Mir-X mirna First-Strand Synthesis Kit User Manual

For in vitro preparation of human mononuclear cells from peripheral blood, bone marrow, and umbilical cord blood. Not for in vitro diagnostic use.

Intended Use: The kit is designed to detect the 5 different mutations found in Asian population using seven different primers.

Application Note. USD 2995 (a) High Throughput Regeneration Study on MEP HyperCel Mixed-Mode Sorbent on ScreenExpert RoboColumns u

50 g 650 L. *Average yields will vary depending upon a number of factors including type of phage, growth conditions used and developmental stage.

Blue Sepharose 6 Fast Flow

QIAGEN Supplementary Protocol

The fastest spin-column based procedure for purifying up to 10 mg of ultra-pure endotoxin-free transfection-grade plasmid DNA.

GE Healthcare s cell culture media, sera and process liquids

NimbleGen DNA Methylation Microarrays and Services

Application Guide... 2

Classic Immunoprecipitation

FOR REFERENCE PURPOSES

ProteinChip Energy Absorbing Molecules (EAM)

ab Protein Sumoylation Assay Ultra Kit

Cord Blood Re-imagined The use of cord blood stem cells for clinical applications and medical innovations

The RNAi Consortium (TRC) Broad Institute

Smart Asset Management Services

UltraClean Soil DNA Isolation Kit

Path-ID Multiplex One-Step RT-PCR Kit

Affi-Prep Protein A Matrix Instruction Manual

illustra TempliPhi DNA Sequencing Template Amplification Kit

How To Test For Cleaning Efficiency With A Predictor 96 Well Filter Plate

Protocol v001 Page 1 of 1 AGENCOURT RNACLEAN XP IN VITRO PRODUCED RNA AND CDNA PURIFICATION

A novel AIEX chromatography medium (resin) to remove IgA and IVIG purification process

Wizard DNA Clean-Up System INSTRUCTIONS FOR USE OF PRODUCT A7280.

AxyPrep TM Mag PCR Clean-up Protocol

CompleteⅡ 1st strand cdna Synthesis Kit

AxyPrep Blood Genomic DNA Maxiprep Kit

Diafiltration: A Fast, Efficient Method for Desalting, or Buffer Exchange of Biological Samples

MagExtractor -Genome-

QIAsymphony RGQ Protocol Sheet

HBV Quantitative Real Time PCR Kit

TECHNICAL BULLETIN. FluoroTag FITC Conjugation Kit. Product Number FITC1 Storage Temperature 2 8 C

HiPer RT-PCR Teaching Kit

HiPer Ion Exchange Chromatography Teaching Kit

Clinical and Laboratory Practices Workshops. Helping to improve laboratory skills and the quality of care in resource-limited settings

How To Get Rid Of Small Dna Fragments

ENrich SEC 70 ENrich SEC 650 High-Resolution Size Exclusion Columns Instruction Manual

HisTrap HP, 1 ml and 5 ml

The EliA System Time for the essentials Cost efficient and flexible A boost in service for your laboratory and your clinicians

Image Lab Software for the GS-900 Densitometer

Maxwell 16 Blood DNA Purification System

PrimeSTAR HS DNA Polymerase

Fast Trak Training & Education

User Manual. CelluLyser Lysis and cdna Synthesis Kit. Version 1.4 Oct 2012 From cells to cdna in one tube

Agencourt RNAdvance Blood Kit for Free Circulating DNA and mirna/rna Isolation from μL of Plasma and Serum

RT-PCR: Two-Step Protocol

Genolution Pharmaceuticals, Inc. Life Science and Molecular Diagnostic Products

Kevin Bogart and Justen Andrews. Extraction of Total RNA from Drosophila. CGB Technical Report doi: /cgbtr

Updating the QIAcube operating software

Creatine Kinase Activity Assay Kit (Colorimetric)

Terra PCR Direct Polymerase Mix User Manual

ab StayBlue/AP Plus Stain Kit Instructions for Use An immunohistochemical chromogen substrate for staining tissue sections

Especially developed for the transfection of mammalian cells with sirna or mirna

SEQUENCING SERVICES. McGill University and Génome Québec Innovation Centre JANUARY 21, Version 3.4

One Shot TOP10 Competent Cells

Transcription:

GE Healthcare illustra NAP-25 Columns For the purification of oligonucleotides and small DNA fragments. Desalting and buffer exchange. Product booklet Codes: 17-0852-01 (20 columns) 17-0852-02 (50 columns)

Page finder 1. Legal 3 2. Handling 4 2.1. Safety warnings and precautions 4 2.2. Storage conditions 4 2.3. Expiry 4 3. Components 5 3.1. Kit contents 5 3.2. Materials to be supplied by user 5 3.3. Equipment to be supplied by user 5 4. Description 6 4.1. The basic principle 6 4.2. Introduction 6 4.3. Choosing the appropriate NAP column and buffer volumes 7 4.4. Product Specifications 8 5. Protocol 9 6. Appendices 12 6.1. Related products available from GE Healthcare 12 Tear off sheet: Experienced user protocol 2

1. Legal Product use restriction NAP -25 columns and components have been designed, developed and sold for research purposes only. They are suitable for in vitro use only. No claim or representation is intended for its use to identify any specific organism or for clinical use (diagnostic, prognostic, therapeutic, or blood banking). It is the responsibility of the user to verify the use of NAP-25 columns for a specific application range as the performance characteristics of this product has not been verified to a specific organism. GE and GE monogram are trademarks of General Electric Company AutoSeq, GFX, illustra, MicroSpin, NAP, NICK, ProbeQuant, Rediprime and Sephadex are trademarks of GE Healthcare companies ExoSAP-IT is a trademark of USB Corp Kathon is a trademark of Rohm and Haas Company 2006 General Electric Company All rights reserved. GE Healthcare reserves the right, subject to any regulatory and contractual approval, to make changes in specifications and features shown herein, or discontinue the product described at any time without notice or obligation. Contact your GE Representative for the most current information and a copy of the terms and conditions. http://www.gehealthcare.com/nap GE Healthcare UK Limited. Amersham Place, Little Chalfont, Buckinghamshire, HP7 9NA UK 3

2. Handling 2.1. Safety warnings and precautions Warning: For research use only. Not recommended or intended for diagnosis of disease in humans or animals. Do not use internally or externally in humans or animals. All chemicals should be considered as potentially hazardous. We therefore recommend that this product is handled only by those persons who have been trained in laboratory techniques and that it is used in accordance with the principles of good laboratory practice. Wear suitable protective clothing such as laboratory overalls, safety glasses and gloves. Care should be taken to avoid contact with skin or eyes. In the case of contact with skin or eyes wash immediately with water. See material safety data sheet(s) and/or safety statement(s) for specific advice. 2.2. Storage conditions Store at ambient temperature (4ºC to 30ºC). Do not freeze. 2.3. Expiry For expiry date please refer to outer packaging label. 4

3. Components 3.1. Kit contents Pack Size 20 50 Cat. No. 17-0852-01 17-0852-02 NAP-25 Columns 20 columns 50 columns containing Sephadex G-25 DNA Grade Columns are supplied with Sephadex G-25 DNA Grade in distilled water containing 0.15% Kathon CG/ICP Biocide as preservative. 3.2. Materials to be supplied by user Equilibration buffer, (N.B. any nuclease free buffer is suitable, including water or Tris/EDTA (TE)). Collection tubes for sample collection. 3.3. Equipment to be supplied by user A column support. A suitable receptacle to catch buffer flowthrough. 5

4. Description 4.1. The basic principle NAP columns are disposable columns prepacked with Sephadex G-25 DNA Grade resin and require only gravity to run. They allow DNA purification by the process of gel filtration. Molecules larger than the largest pores in the matrix are excluded from the matrix and elute first. Intermediate size molecules penetrate the matrix to varying extents, depending on their size. Penetration of the matrix retards progress through the column; very small molecules elute last. The volume required to elute these small molecules is dependent on the volume available both inside and outside the pores (i.e. the bed volume). 4.2. Introduction NAP-25 columns are designed for the rapid purification of DNA, by desalting, buffer exchange, and removal of unincorporated nucleotides from end-labeled oligonucleotides. They can be used for any DNA greater than 10 bases in length and are therefore ideal for the purification of oligonucleotides or very small DNA fragments following synthesis or a labeling reaction. They will not remove or denature enzyme. 6

4.3. Choosing the appropriate NAP column and buffer volumes NAP columns are available in three sizes depending on sample volume: up to 0.5 ml (NAP-5), up to 1 ml (NAP-10) or up to 2.5 ml (NAP-25). The table below provides a selection guide: Note: the composition of the equilibration buffer is not critical. Any nuclease free buffer is suitable, including water or Tris/EDTA (TE). Column Type Sample Equilibration Elution Volume (ml) Buffer (ml) Buffer (ml) NAP-5 0.1 0.4 0.5 0.25 0.25 0.7 0.5 max vol 0 1.0 NAP-10 0.75 0.25 1.2 1.0 max vol 0 1.5 NAP-25 1.5 1.0 2.5 2.0 0.5 3.0 2.5 max vol 0 3.5 7

4.4 Product Specifications Format Principle Column matrix Column buffer Gravity flow column Gel filtration Sephadex G-25 DNA grade Distilled water containing 0.15% Kathon Yield / Recovery of DNA >90% Purity of recovered DNA Length of labeled DNA recovered Major subsequent application Column capacity (maximum amount of DNA that can be loaded onto column) Typically <3% salt contamination >10 bp (N.B. there is no maximum length of oligonucleotide that can be purified) PCR, sequencing, labeling <1 mg/ml Do not load a DNA solution of a concentration greater than 1 mg/ml. Higher concentrations reduce column resolution and give lower yield due to increased viscosity. Samples at a concentration greater than 1 mg/ml should be diluted with equilibration buffer prior to loading. 8

5. Protocol Prior to commencing, ensure that the NAP-25 columns have equilibrated to ambient temperature. 1. Support the column over a suitable receptacle to catch buffer flow through. Remove the top and bottom caps from the NAP-25 column and allow the excess liquid to flow through the column. Note: not allowing the excess liquid to flow through the column prior to use will result in slow flow rates. 2. Equilibrate the gel with approximately 25 ml of equilibration buffer. Note: this volume corresponds to 3 complete refills of the column. Note: the composition of the equilibration buffer is not critical. Any nuclease free buffer is suitable, including water or Tris/EDTA (TE). It is important to use the same buffer in steps 2, 3, 5 and 7 and so this buffer will be the one that the sample is to be eluted into. 3. Allow the equilibration buffer to completely enter the gel bed by gravity flow. Do not apply positive pressure. 4. Add the sample to the column in a maximum volume of 2.5 ml. If the sample volume is less than 2.5 ml, do not adjust it at this time. Allow the sample to enter the gel bed completely. 9

Note: if the sample volume is less than 2.5 ml and you wish to elute your sample using the minimum volume of equilibration buffer (see Table 1. Buffer volume guide below) it is important not to adjust the sample volume to 2.5 ml with equilibration buffer at this point. For example: if 1.5 ml sample is loaded onto the column and allowed to enter the gel bed completely (as in step 4), and then 1.0 ml of equilibration buffer is added to the column and allowed to enter the gel bed completely (as in step 5), the sample can be eluted using just 2.5 ml equilibration buffer (as shown in Table 1 below). This is because the sample volume loaded onto the column is small and will elute earlier. Alternatively, if the sample is adjusted to 2.5 ml using the equilibration buffer and then added to the column in step 4 it would be necessary to elute with 3.5 ml equilibration buffer in order to obtain the maximum yield of the sample. Table 1. Buffer volume guide Column Type Sample Equilibration Elution Volume (ml) Buffer (ml) Buffer (ml) NAP-25 1.5 1.0 2.5 2.0 0.5 3.0 2.5 max vol 0 3.5 Note: concentration of the DNA sample should be below 1 mg/ml, as higher concentrations tend to reduce resolution and give lower yields due to increased viscosity. 10

5. For sample volumes less than 2.5 ml, add equilibration buffer so that the combined volume of sample added in step 4 and buffer added in step 5 equal 2.5 ml. Allow the equilibration buffer to enter the gel bed completely. 6. Place an appropriate size collection tube for sample collection under the column. 7. Elute the purified sample with an appropriate volume of equilibration buffer (please refer to Table 1. Buffer volume guide which can be found in step 4). Note: If you require a concentrated sample, collect 0.1 ml fractions as the sample elutes off the column. The concentration of the different fractions can be quantitated using a spectrophotometer or by loading 5 μl of each fraction onto an analytical gel (agarose or acrylamide). 11

6. Appendices 6.1. Related products available from GE Healthcare Application Product Product Code Pack Size Radiactive labeling Rediprime II RPN1633 30 rxns DNA labeling system Nick Translation kit N5000 20 rxns 5 -end labeling kit RPN1509 20 rxns Purification of MicroSpin oligonucleotides G-25 columns 27-5325-01 50 following synthesis (buffer columns exchange and desalt). Spin column format PCR and enzymatic GFX PCR and 28903470 100 DNA reaction gel band columns purification extraction kit (enzyme removal, buffer exchange, desalt, primer removal), 100 bp-10 kb size range Extraction of DNA from agarose gels 12

Rapid and efficient ExoSAP-IT US78201 500 rxns purification of PCR products for automated sequencing One-tube, one-step method Dye terminator removal AutoSeq G-50 27-5340-01 50 from automated columns sequencing reactions Unincorporated labeled ProbeQuant 28903408 50 nucleotide removal G-50 Micro columns from a DNA labeling Columns reaction Spin column format Unincorporated labeled NICK columns 17-0855-02 50 nucleotide removal columns from a DNA labeling reaction Gravity flow A full range of reagents can be found in the GE Healthcare catalogue. If you need any further information, GE Healthcare technical services are always happy to assist. http://www.gehealthcare.com/nap 13

14

15

GE Healthcare offices: GE Healthcare Bio-Sciences AB Björkgatan 30 751 84 Uppsala Sweden GE Healthcare Europe GmbH Munzinger Strasse 5 D-79111 Freiburg Germany GE Healthcare regional office contact numbers: Asia Pacific Tel: +85 65 6 275 1830 Fax: +85 65 62751829 Australasia Tel: + 61 2 8820 8299 Fax: +61 2 8820 8200 France Tel: 01 6935 6700 Fax: 01 6941 9877 Germany Tel: 0800 9080 711 Fax: 0800 9080 712 Greater China Tel: +852 2100 6300 Fax: +852 2100 6338 Portugal Tel: 21 417 7035 Fax: 21 417 3184 Russia & other C.I.S. & N.I.S Tel: +7 495 956 5177 Fax: +7 495 956 5176 Spain Tel: 902 11 72 65 Fax: 935 94 49 65 GE Healthcare UK Limited Amersham Place Little Chalfont Austria Tel: 01/57606-1613 Fax: 01/57606-1614 Italy Tel: 02 26001 320 Fax: 02 26001 399 Sweden Tel: 018 612 1900 Fax: 018 612 1910 Buckinghamshire HP7 9NA UK Belgium Tel: 0800 73 890 Fax: 02 416 82 06 Japan Tel: +81 3 5331 9336 Fax: +81 3 5331 9370 Switzerland Tel: 0848 8028 10 Fax: 0848 8028 11 GE Healthcare Bio-Sciences Corp 800 Centennial Avenue P.O. Box 1327 Piscataway NJ 08855-1327 USA GE Healthcare Bio-Sciences KK Sanken Bldg. 3-25-1 Hyakunincho Shinjuku-ku Tokyo 169-0073 Japan Canada Tel: 1 800 463 5800 Fax: 1 800 567 1008 Central & East Europe Tel: +43 1 972 720 Fax: +43 1 972 722 750 Denmark Tel: 45 16 2450 Fax: 45 16 2424 Eire Tel: 1 800 709992 Fax: +44 1494 542010 Korea Tel: 82 2 6201 3700 Fax: 82 2 6201 3803 Latin America Tel: +55 11 3933 7300 Fax: + 55 11 3933 7304 Middle East & Africa Tel: +30 210 9600 687 Fax: +30 210 9600 693 Netherlands Tel: 0800 8282821 Fax: 0800 8282824 UK Tel: 0800 515 313 Fax: 0800 616 927 USA Tel: +1 800 526 3593 Fax: +1 877 295 8102 Finland & Baltics Norway Tel: +358-(0)9-512 39 40 Tel: +47 815 65 777 Fax: +358 (0)9 512 39 439 Fax: +47 815 65 666 http://www.gehealthcare.com/nap GE Healthcare UK Limited Amersham Place, Little Chalfont, Buckinghamshire, HP7 9NA UK imagination at work 17-0852-01PL Rev A 2006

The next two pages are a protocol card. If required please add to the back page as a tear off addition If not then delete these three pages.

illustra NAP-25 Columns 17-0852-01 (20 columns) 17-0852-02 (50 columns) For the purification of oligonucleotides and small DNA fragments. Desalting and buffer exchange. Experienced user protocol 1. Remove top and bottom caps from the column and allow the excess liquid to flow through the column. 2. Equilibrate the gel with 25 ml equilibration buffer.. 3. Add the sample to the column. 4. Elute the purified sample. 17-0852-01PC Rev A 2006

NAP-25 Columns 17-0852-01 (20 columns) 17-0852-02 (50 columns) For the purification of oligonucleotides and small DNA fragments. Desalting and buffer exchange. Buffer volume guide Column Type Sample Equilibration Elution Volume (ml) Buffer (ml) Buffer (ml) NAP-25 1.5 1.0 2.5 2.0 0.5 3.0 2.5 max vol 0 3.5 GE and GE monogram are trademarks of General Electric Company. illustra and NAP are trademarks of GE Healthcare companies. 2006 General Electric Company All rights reserved. GE Healthcare reserves the right, subject to any regulatory approval, to make changes in specifications and features shown herein, or discontinue the product described at any time without notice or obligation. Contact your GE Representative for the most current information and a copy of the terms and conditions http://www.gehealthcare.com/nap GE Healthcare UK Limited Amersham Place Little Chalfont Buckinghamshire HP7 9NA UK imagination at work