Compliance-oriented development of innovative medical devices from research to market

Similar documents
GUIDANCE NOTES FOR MANUFACTURERS OF CLASS I MEDICAL DEVICES

Safeguarding public health The Regulation of Software as a Medical Device

(OJ L 169, , p. 1)

CE Marking: Your Key to Entering the European Market

Medical Device Software Do You Understand How Software is Regulated?

Med-Info. Council Directive 93/42/EEC on Medical Devices. TÜV SÜD Product Service GmbH

How To Know If A Mobile App Is A Medical Device

2002 No. 618 CONSUMER PROTECTION. The Medical Devices Regulations 2002

Medical Devices. Notified Bodies and the CE certification Process for Medical Devices. European Surgical Robotics Demonstration Day

Reporting Changes to your Notified Body

GUIDANCE NOTE FOR MANUFACTURERS OF CUSTOM-MADE MEDICAL DEVICES

WHITEPAPER: SOFTWARE APPS AS MEDICAL DEVICES THE REGULATORY LANDSCAPE

Guidance on the In Vitro Diagnostic Medical Devices Directive 98/79/EC

Guide for Custom-Made Dental Device Manufacturers on Compliance with European Communities (Medical Devices) Regulations, 1994

An introduction to the regulation of apps and wearables as medical devices

UNDERSTANDING THE EC DIRECTIVE 98/79/EC ON IN VITRO DIAGNOSTIC MEDICAL DEVICES

Regulatory Strategy for Drug-Device Combinations By John Worroll

National Decontamination Guidance on Loan Medical Devices (Reusable): Roles & Responsibilities GUID 5002

Medical Software Development. International standards requirements and practice

Medical Device Directive 2007/47/EC What is New? Are we moving towards Drug Rules?

MEDICAL DEVICES INTERIM REGULATION

Medical Devices: CE Marking Step-by Step

Navigating the New EU Rules for Medical Device Software

CE Marking Changing & Evolving Requirements September BSI Healthcare Roadshow

Basic Information about the European Directive 93/42/EEC on Medical Devices

Guidelines for conformity assessment of In Vitro Fertilisation (IVF) and Assisted Reproduction Technologies (ART) products

US & CANADA: REGULATION AND GUIDELINES ON MEDICAL SOFTWARE AND APPS OR

Schneps, Leila; Colmez, Coralie. Math on Trial : How Numbers Get Used and Abused in the Courtroom. New York, NY, USA: Basic Books, p i.

Final Document. Software as a Medical Device (SaMD): Key Definitions. Date: 9 December Despina Spanou, IMDRF Chair. IMDRF/SaMD WG/N10FINAL:2013

Emerging Device Topics for Regulatory Consideration.. Janine Jamieson May 2015

Guidance Notes for Applicants of the Certificate for Clinical Trial on Medical Device

Medical Certification: Bringing genomic microcores to clinical use OI- VF- WP- 011

The Act on Medical Devices

Guidance for manufacturers and Notified Bodies on reporting of Design Changes and Changes of the Quality System

Introduction Processes and KPIs Health Care Value Chain. Rafael Provencio

Clinical evaluation Latest development in expectations EU and USA

GOOD DISTRIBUTION PRACTICE FOR MEDICAL DEVICES (GDPMD)

Medical Device Software Standards for Safety and Regulatory Compliance

NOTICE TO MANUFACTURERS OF RADIOTHERAPY MEDICAL DEVICES

BSI Unannounced Audits

Medical Devices. IRELAND Arthur Cox

Software within the medical device regulatory framework in the EU

Implementation of ANSI/AAMI/IEC Medical Device Software Lifecycle Processes.

Processes for the Development of Healthcare Applications. Christian Johner

GUIDELINES ON MEDICAL DEVICES. IVD GUIDANCES : Borderline issues A GUIDE FOR MANUFACTURERS AND NOTIFIED BODIES

CHAPTER 3 SCOPE AND STANDARDS OF NURSING PRACTICE AND CNA ROLE

GUIDELINES ON MEDICAL DEVICES EVALUATION OF CLINICAL DATA : A GUIDE FOR MANUFACTURERS AND NOTIFIED BODIES

Registration of Class B Medical Devices

Quality Assurance Manual

EU Law and Life Sciences Mobile Health Apps. Webinar - Brussels, 9 July 2014

GUIDELINES ON MEDICAL DEVICES

MONTANA STATE HOSPITAL POLICY AND PROCEDURE WORKER S COMPENSATION

EPF Position Statement on the European Commission s proposal for a Regulation on In Vitro Medical Devices

Glossary of terms used in our standards. June Upholding standards and public trust in pharmacy

This is Document Schedule 5 Part 1 referred to in this Contract SCOTTISH MINISTERS REQUIREMENTS SCHEDULE 5 PART 1 QUALITY MANAGEMENT SYSTEM

Vigilance Reporting. Vicky Medley - Head of QMS, Medical Devices. September Copyright 2015 BSI. All rights reserved.

Medical Device Classification

Conformity assessment certification

CE Marking and Technical Standardisation

AGREEMENT On the Uniform Principles and Rules Governing Market Circulation of Medical Devices within the Eurasian Economic Union

A Revised EMC Directive from Europe

The New Paradigm for Medical Device Safety. Addressing the Requirements of IEC Edition 3.1

Risk Management and the Impact of EN ISO 14971:2012 Annex Z

APMI CODE OF PRACTICE ON ADVERTISING OF MEDICINAL PRODUCTS ISSUE 1

EMKI has competence in conformity assessment - on the basis of EU directives 93 /42/EEC - for companies dealing with product ranges listed below.

The Regulation of Medical Devices in the UK

Manual for ITC's clients, Conformity assessment of ACTIVE IMPLANTABLE MEDICAL DEVICES pursuant to Council Directive 90/385/EEC

The Medical Products Agency s Working Group on Medical Information Systems. Project summary

Konformitätsbewertung 3.9 B 17. Guidance for Notified Bodies auditing suppliers to medical device manufacturers

Introduction into IEC Software life cycle for medical devices

International standards and guidance that address Medical Device Software

WORKING DOCUMENT FOR SCC CONSULTATION CONSTRUCT09/874 EUROPEAN COMMISSION ENTERPRISE AND INDUSTRY DIRECTORATE-GENERAL

Regulatory Considerations for Medical Device Software. Medical Device Software

PLM: Privat Label Manufacturer (Customer of the OEM-PLM relation) OEM: Original Equipment Manufacturer (Supplier of the OEM-PLM relation)

GOVERNMENT OF THE RUSSIAN FEDERATION RESOLUTION from December 27, 2012 N 1416 APPROVAL OF THE RULES STATE REGISTRATION OF MEDICAL PRODUCTS

Health Informatics Application of clinical risk management to the manufacture of health software Formerly ISO/TS 29321:2008(E) DSCN14/2009

CE MARKING OF MEDICAL DEVICES Guide

Correspondence between ISO 13485:2003 and the US Quality System Regulation

BSI: An In Vitro Diagnostics Notified Body. A guide to the In Vitro Diagnostic Directive....making excellence a habit.

Regulated Mobile Applications

Medical Device Regulatory Requirements for Taiwan

MEDICAL DEVICES REGULATIONS

A. CPT Coding System B. CPT Categories, Subcategories, and Headings

Medical Information Systems. guidance for qualification and classification of standalone software with a medical purpose

Clinical Data for Medical Devices

Medical Device Training Program 2015

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

Understanding Medical Device Regulation for mhealth A Guide for Mobile Operators

Response of the German Medical Association

How To Protect Mental Health Information In Upb

Revision of the Directive 98/79/EC on In Vitro Diagnostic Medical Devices. Response from Cancer Research UK to the Commission August 2010

Abstract. Introduction

Frequently Asked Questions. Unannounced audits for manufacturers of CE-marked medical devices. 720 DM a Rev /10/02

Medical Technologies Evaluation Programme Methods guide

Transcription:

Compliance-oriented development of innovative medical devices from research to market Workshop at BRI 10.02.2016 Pontedera, Italy Ovesco Endoscopy AG Tuebingen, Germany Dr. Sebastian Schostek sebastian.schostek@ovesco.com

TRL and the valley of death Why regulations? Some basics The how-to

TRL and the valley of death Compliance Workshop 10.02.2016 Valley of death 3

TRL and the valley of death Compliance Workshop 10.02.2016 Valley of death 4 Resources spent Resources required

TRL and the valley of death Why regulations? Some basics The how-to

Innovation in medical technologies 6 Disruptive innovations cause the interface between engineering and medicine to oscillate this drives the advancement of a new field. Here: Minimally invasive surgery. Engineering: TECHNOLOGY Medicine: TECHNIQUE Technology push through a novel technique New technology requires the development of novel techniques Technology push through a novel technique Kurt Semm 1980: The advent of Minimally Invasive Surgery (MIS)

Innovation in medical technologies 7 The driving cycle consist of four essential steps. An advancement in one discipline requires and advancement in the other (steps 1, 3). Decisive is the purposeful translation between the fields (steps 2, 4). Engineering: TECHNOLOGY Consequence: Increased level of complexity and difficulty 2 Motivation: Facilitate / ease procedures through technology Consequence: Increased level of complexity and difficulty 1 3 1 Medicine: TECHNIQUE Motivation: Improve safety, efficacy and patient comfort Consequence: New technique related paradigms (e.g. user interface) 4 Motivation: Improve safety, efficacy and patient comfort Kurt Semm 1980: The advent of Minimally Invasive Surgery (MIS)

8 Innovation in medical technologies Engineering: TECHNOLOGY Medicine: TECHNIQUE Wilhelm Conrad Röntgen 1895 Learnings: In the field of medical technology, the emergence of innovations realies on both engineers and doctors to the same extent (symmetrical). An innovation can be driven by either engineering or medicine. Decisive for exploitation is to purposefully act at the interface between both fields. Engineering: TECHNOLOGY Medicine: TECHNIQUE Kurt Semm 1980

Innovation in medical technologies: Stakeholders 9 Politics and authorities Medical device industry Market (Naiv population) Interface Healthcare providers Payers

What s so special about medical devices? 10 Industrial product, e.g. smartphone It is safe It works It is easy to use Service is provided Good guidance provided Price Colour Design Medical device, e.g. EndoVESPA It is safe It works It is easy to use Service is provided Good guidance provided Price Colour Design

TRL and the valley of death Why regulations? Some basics The how-to

Definition of a medical device (see MDD 93/42/EEC) 12 Medical device means any instrument, apparatus, appliance, software, material or other article, whether used alone or in combination, including the software intended by its manufacturer to be used specifically for diagnostic and/or therapeutic purposes and necessary for its proper application, intended by the manufacturer to be used for human beings for the purpose of: diagnosis, prevention, monitoring, treatment or alleviation of disease, diagnosis, monitoring, treatment, alleviation of or compensation for an injury or handicap, investigation, replacement or modification of the anatomy or of a physiological process, control of conception, and which does not achieve its principal intended action in or on the human body by pharmacological, immunological or metabolic means, but which may be assisted in its function by such means.

Compliance It s all about requirements 13 Directives and standards Top-down requirements Design input Medical device development Notified body Market Design input Bottom-up requirements User requirements, risk management file output, usability file output, manufacturability, marketing, etc.

Compliance It s all about requirements 14 Directives and standards Top-down requirements Design input Medical device development Notified body Market Design input Bottom-up requirements User requirements, risk management file output, usability file output, manufacturability, marketing, etc.

Directives Why regulations? Compliance Workshop 10.02.2016 Compliance Top-down requirements 15 Directives: MDD 93/42 or AIMD 90/385 or IVD 98/79 MDD: Medical Device Directive 93/42/EEC Applies to all other Medical devices Includes classification AIMD: Active implantable medical devices 90/385/EEC Applies to AIMD only No classification included IVD: In-vitro diagnostic medical devices 98/79/EC Applys to IVD only No classification included

Compliance Top-down requirements 16 MDD: Medical Device Directive 93/42/EEC Article 1: Definitions, scope Article 2: Placing on the market and putting into service Article 3: Essential requirements Article 4: Free movement, devices intended for special pruposes Article 5: Reference to standards Article 6: Committee on Standards and Technical Regulations Article 7: The Committee Article 8: Safeguard claus Article 9: Classification Article 10: Information on incidents occuring following placing of devices on the market Article 11: Conformity assessment procedures Article 12: Particular procedure for systems and procedure packs and procedure for sterilisation Article 13: Decision with regard to classification and derogation clause Article 14: Registration of persons responsible for placing devices on the market Article 15: Clinical investigation Article 16: Notified bodies Article 17: CE marking Article 18: Wrongly affixed CE marking Article 19: Decision in respect of refusal or restriction Article 20: Confidentiality Article 21: Repeal and amendment of Directives Article 22: Implementation, transitional provisions Annex I: Essential requirements Annex II: EC declaration of conformity Annex III: EC type-examination Annex IV: EC verification Annex V: EC declaration of conformity (production quality assurance) Annex VI: EC declaration of conformity (product quality assurance) Annex VII: EC declaration of conformity Annex VIII: Statement concerning devices for special purposes Annex IX: Classification criteria Annex X: Clinical evaluation Annex XI: Criteria to be met for the designation of notified bodies Annex XII: CE marking of conformity

Compliance Top-down requirements 17 MDD: Medical Device Directive 93/42/EEC Article 1: Definitions, scope Article 2: Placing on the market and putting into service Article 3: Essential requirements Article 4: Free movement, devices intended for special pruposes Article 5: Reference to standards Article 6: Committee on Standards and Technical Regulations Article 7: The Committee Article 8: Safeguard claus Article 9: Classification Article 10: Information on incidents occuring following placing of devices on the market Article 11: Conformity assessment procedures Article 12: Particular procedure for systems and procedure packs and procedure for sterilisation Article 13: Decision with regard to classification and derogation clause Article 14: Registration of persons responsible for placing devices on the market Article 15: Clinical investigation Article 16: Notified bodies Article 17: CE marking Article 18: Wrongly affixed CE marking Article 19: Decision in respect of refusal or restriction Article 20: Confidentiality Article 21: Repeal and amendment of Directives Article 22: Implementation, transitional provisions Annex I: Essential requirements Annex II: EC declaration of conformity Annex III: EC type-examination Annex IV: EC verification Annex V: EC declaration of conformity (production quality assurance) Annex VI: EC declaration of conformity (product quality assurance) Annex VII: EC declaration of conformity Annex VIII: Statement concerning devices for special purposes Annex IX: Classification criteria Annex X: Clinical evaluation Annex XI: Criteria to be met for the designation of notified bodies Annex XII: CE marking of conformity

Compliance Top-down requirements 18 MDD: Medical Device Directive 93/42/EEC Article 1: Definitions, scope Article 2: Placing on the market and putting into service Article 3: Essential requirements Article 4: Free movement, devices intended for special pruposes Article 5: Reference to standards Article 6: Committee on Standards and Technical Regulations Article 7: The Committee Article 8: Safeguard claus Article 9: Classification Article 10: Information on incidents occuring following placing of devices on the market Article 11: Conformity assessment procedures Article 12: Particular procedure for systems and procedure packs and procedure for sterilisation Article 13: Decision with regard to classification and derogation clause Article 14: Registration of persons responsible for placing devices on the market Article 15: Clinical investigation Article 16: Notified bodies Article 17: CE marking Article 18: Wrongly affixed CE marking Article 19: Decision in respect of refusal or restriction Article 20: Confidentiality Article 21: Repeal and amendment of Directives Article 22: Implementation, transitional provisions Annex I: Essential requirements Annex II: EC declaration of conformity Annex III: EC type-examination Annex IV: EC verification Annex V: EC declaration of conformity (production quality assurance) Annex VI: EC declaration of conformity (product quality assurance) Annex VII: EC declaration of conformity Annex VIII: Statement concerning devices for special purposes Annex IX: Classification criteria Annex X: Clinical evaluation Annex XI: Criteria to be met for the designation of notified bodies Annex XII: CE marking of conformity

Compliance Top-down requirements 19 Harmonized standards For a start: focus on standards with relevance on construction and design

Compliance It s all about requirements 20 Directives and standards Top-down requirements Design input Medical device development Notified body Market Design input Bottom-up requirements User requirements, risk management file output, usability file output, manufacturability, marketing, etc.

Compliance Bottom-up requirements 21 Risk management file User requirements EN ISO 14971 Medical device, e.g. EndoVESPA It is safe It works Usability file EN 62366 It is easy to use Service is provided Good guidance provided Manufacturer certification EN ISO 13485 Manufacturability Marketing Price Colour Design

TRL and the valley of death Why regulations? Some basics The how-to

The how-to - Compliance Workshop 10.02.2016 Methodology: Sources (non-exclusive) 23 Europe: EN ISO 13485 Chapter 7.3 For programmable electrical medical systems (PEMS): EN 60601-1 (3 rd edition) Chapter 14.4 For medical software: EN 62304 FDA: CFR 820.30 Design controls Available online (google CFR 820.30)

The how-to - Compliance Workshop 10.02.2016 24 Methodology: Implementation Start Planning Project plan User needs A A normative and regulatory requirements User requirements Application validation plan Design Input Product requirements Test plan Execution A Risk management Usability Verification and validation Outputs Manufacturability Test reports Specifications Transfer into production List of applicable Standards Application validation Manufacturing documentation Conformity evaluation End Riskmanagement file Validation reports Technical documentation Usability file Manufacturability input

The how-to - Compliance Workshop 10.02.2016 Methodology: Implementation 25 Start Planning A Project plan normative and regulatory requirements User needs User requirements Application validation plan A Design Input Product requirements Test plan Execution Iterative development cycle A Risk management Usability Verification and validation Outputs Manufacturability Test reports Specifications Transfer into production List of applicable Standards Application validation Manufacturing documentation Conformity evaluation End Riskmanagement file Validation reports Technical documentation Usability file Manufacturability input

Thank you Compliance-oriented development of innovative medical devices from research to market Workshop at BRI 10.02.2016 Pontedera, Italy Ovesco Endoscopy AG Tuebingen, Germany Dr. Sebastian Schostek sebastian.schostek@ovesco.com