First steps for success. Getting to know continuous glucose monitoring (CGM).

Similar documents
Insulin Pump Management and Continuous Glucose Monitoring Systems (CGMS)

CONTINUOUS GLUCOSE MONITORING SYSTEM. Receiver with Share TM USER S GUIDE

CONTINUOUS GLUCOSE MONITORING SYSTEM USER S GUIDE

Get to know the Animas Vibe insulin pump and CGM * system.

Basal and Bolus Insulin 7/16/2014. Jackie Aday RN, BSN, CDE Jeni Neighbors RN, BSN, CDE. BASAL: Small amount of insulin infused every few minutes

IMPORTANT CONTACTS AND NUMBERS

Why is Insulin so Important?

DIABETES. Eyes, Heart, Nerves, Feet, and Kidneys.

OneTouch Reveal Web Application. User Manual for Patients Instructions for Use

How to get the most of your blood glucose readings

Blood Glucose Monitoring Basics

Medical Coverage Policy Glucose Monitoring Systems sad

BOLUS INSULIN DOSAGES H. Peter Chase, MD and Erin Cobry, BS

The OmniPod Insulin Management System

MANAGING YOUR DIABETES WITH AN INSULIN PUMP

4/7/2015 CONFLICT OF INTEREST DISCLOSURE OBJECTIVES. Conflicts of Interest None Heather Rush. Heather M. Rush, APRN, CDE Louisville, KY

A guidebook for people with diabetes

Methods for Delivering Insulin and Monitoring Blood Sugar. A Review of the Research for Children, Teens, and Adults With Diabetes

Insulin Dose Adjustment REAL-Time CGMS Guidelines for Subjects on Pump Therapy

Blood Sugar Testing. Bayer Health Facts

Objectives PERINATAL INSULIN PUMPS: BASICS FOR NURSES. Historical Perspective. Insulin Pumps in Pregnancy. Insulin Pumps in the US

Alternative method for delivering insulin using continuous subcutaneous insulin infusion (CSII) open loop system

Self-Monitoring of Blood Glucose

Corporate Medical Policy

MiniMed 640G System Intelligent for Better Control

Mobile App User Guide

Health Professional s. Guide to INSULIN PUMP THERAPY

FLASH GLUCOSE MONITORING SYSTEM. User s Manual

Causes, incidence, and risk factors

BLOOD GLUCOSE METER. Standard Owner s Booklet for Single Patient Use Only

Smart Pumping with Insulin Pumps

Gestational diabetes. Information to help you stay healthy during your pregnancy. What is gestational diabetes?

The FreeStyle Lite Meter and How It Works

Diabetes Hypoglycemia/Hyperglycemia Reaction

Inform II. Quick Reference Guide. for Healthcare Professionals BLOOD GLUCOSE MONITORING SYSTEM

You and Your Child s Rights. What is a 504 Plan? Who Qualifies for a 504? 3/11/2014. Speak Softly and Carry a Big Stick!

Abbott Diabetes Care Inc. ART20494 Rev. B 02/11

P R E S S U R E P O I N T S S E R I E S : Measuring your blood pressure at home

The MiniMed Paradigm Veo System A step-by-step guide

Diabetes Insulin Pump Health Care Plan District Nurse Phone: District Nurse Fax:

Insulin Pumps. with Diabetes

The Diabetes Self Management Insulin Pump Therapy Program

Report reference guide. mmol/l. One. solution EMR. No fuss

Diabetes means you have too much sugar in

Continuous Subcutaneous Insulin Infusion (CSII) pump therapy

Insulin Delivery System. Reference Guide

A patient guide to the use of insulin for diabetes

The MiniMed Paradigm Veo System

Blood Glucose Management

User Manual Important: First read the Medication Guide that comes inside your FORTEO carton.

2. What Should Advocates Know About Diabetes? O

QUESTION 3. HOW SHOULD THE DATA AND REPORTING BE INTERPRETED?

Introducing DEXCOM STUDIO INTUITIVE. FOCUSED. SIMPLIFIED. HELP TAKE the GUESSWORK OUT of GLUCOSE PATTERN MANAGEMENT

Understanding Diabetes

MEDICATION GUIDE ACTOPLUS MET (ak-tō-plus-met) (pioglitazone hydrochloride and metformin hydrochloride) tablets

The Quantified Self on Steroids: Innovation in Devices, Pumps and Monitors

BLOOD GLUCOSE METER. Getting Started Guide for Single Patient Use Only

Ketones & diabetes; Reduce your risk!

Mobile App User Guide

A Reference Guide for School Nurses. with the Medtronic MiniMed Insulin Pump

Accu-Chek Connect Online diabetes management system. Setup Guide for Healthcare Providers

My Sick Day Plan for Type 1 Diabetes on an Insulin Pump

written by Harvard Medical School Insulin Therapy Managing Your Diabetes

Medical Benefit Effective Date: 04/01/11 Next Review Date: 01/13 Preauthorization* Yes Review Dates: 07/07, 07/08, 07/09, 01/10, 01/11, 01/12

Guidelines for Education and Training

Imagine a world... Believe in better control. MiniMed Veo Paradigm System Questions and Answers About Insulin Pumping

Humulin (HU-mu-lin) R

FDA Perspective on Closed-Loop Studies

Introduction to Insulin. Your guide to taking insulin

Telserve Licensed Healthcare Professional User Manual

Imagine a world... Believe in better control. MiniMed Veo Paradigm System

Dexcom Portrait on the Web User Guide For Use with the Dexcom G4 PLATINUM Continuous Glucose Monitoring System

Description. Comprehensive Education Courses Take Control Now! (2 Hour Session Billed to Insurance)

DIABETIC EDUCATION MODULE ONE GENERAL OVERVIEW OF TREATMENT AND SAFETY

Blood Sugar and How to Manage It

JDRF Type One Nation Research Summit Diabetes Technology: A Bridge to a Cure

Insulin is a hormone produced by the pancreas to control blood sugar. Diabetes can be caused by too little insulin, resistance to insulin, or both.

Taking Insulin Pumps to School. Rachel Calendo, MS, RN, CPNP, CDE, Martha Cuevas, RN, BSN, CPT

Introduction. What does PICO do? How does PICO work?

Script/Notes for PowerPoint Presentation. Medication Use Safety Training for Seniors (MUST for Seniors)

HUMULIN (HU-mu-lin) N

High Blood Pressure and Chronic Kidney Disease. For People With CKD Stages 1 4

Getting the most from blood pressure medicines

Is what you know about INSULIN PUMP THERAPY. This educational resource is provided by Medtronic MiniMed, Inc.

You are a doctor at a busy general practice surgery in the city suburbs.

Diabetes and Technology. Disclosures Certified Insulin Pump Trainer for: Animas Medtronic Diabetes Omnipod. Rebecca Ray, MSN, APRN, FNP-C

Hypoglycemia and Diabetes

YOUR GUIDE TO THE LANTUS SOLOSTAR INSULIN PEN

Insulin Pump Therapy during Pregnancy and Birth

Electronic Bid Submission Supplier Guide

High Blood pressure and chronic kidney disease

SCHOOL DISTRICT #22 VERNON DIABETES POLICY

Information for Starting Insulin Basal-Bolus Regime

Diabetes Mellitus: Type 1

Are you ready to pump?

Insulin Dependent Diabetes Trust

Managing the Diabetes Patient. Dan Kremer, RN, BSN Diabetes Nurse Educator

Diabetes at the End of Life. Dr David Kerr MD Bournemouth Diabetes and Endocrine Centre

Instructions for Use

The Basics of Insulin Pump Therapy

Transcription:

First steps for success. Getting to know continuous glucose monitoring (CGM). The Animas Vibe System is approved for persons age 2 and older.

Important Safety Information The Animas Vibe Insulin Pump and CGM System is intended for the delivery of insulin and for continuous glucose monitoring (CGM) for the management of insulin-requiring diabetes. The Animas Vibe System s CGM, which includes the Dexcom G4 PLATINUM Sensor and Transmitter, is indicated for detecting trends and tracking patterns in persons age 2 and older. The system is intended for single patient use and requires a prescription. Contraindications: Insulin pump therapy is not recommended for people unwilling or unable to test their blood glucose four to six times per day, unwilling or unable to see their healthcare professional regularly, or whose vision or hearing does not allow recognition of pump alerts, warnings, and alarms. The Animas Vibe Insulin Pump must be removed before MRI or CT scan, and the Dexcom G4 PLATINUM Sensor and Transmitter must be removed before MRI, CT scan, or diathermy treatment. Taking acetaminophen-containing medications while wearing the sensor may falsely raise sensor glucose readings. Warnings: Connecting to the pump before receiving the necessary training could result in serious injury or death. Younger children may inadvertently press the pump buttons and deliver insulin, which can lead to hypoglycemic events. Caregivers are responsible for helping to ensure safe and effective delivery of insulin to people in their care, including using the safety features on the Animas Vibe System to help prevent injury. CGM glucose readings are not to be used to make treatment decisions. The sensor and transmitter do not replace a blood glucose meter. The sensor and transmitter are not to be used during pregnancy or while on dialysis. Sensor placement is only approved for sites under the skin of the belly (abdomen) in adults and the belly or upper buttocks for ages 2 to 17 (pediatrics). Patients should seek professional medical help if a sensor breaks and no portion of it is visible above the skin, or if there is infection or inflammation. Any broken sensors or adverse events should be reported to Customer Service. Contact Customer Service at 1-877-937-7867 or visit www.animas.com/importantsafetyinformation for detailed indications for use and safety information.

Welcome to the First Steps for Success: Getting to Know CGM training course. If you have never experienced CGM before, this course is for you. Starting CGM can be an emotional experience. You are going to learn more about your body and your diabetes. The purpose of this course is to help you understand what to expect your first week on CGM and help make your first week a success. Please note: We recommend that you insert your first Sensor and start your first Sensor session prior to taking this course. The Animas Vibe Insulin Pump and CGM System Owner s Booklet provides you with a thorough understanding of the Animas Vibe System and how to get the most from it. Please read it carefully.

Expect the unexpected. Your first week on CGM may be an emotional roller coaster. These are some common situations you may see your first week: "I guess I took too much insulin." "I didn't know pizza did this to me." 3 hours in my target range!"

Watch and learn. Accept what comes your way and learn from CGM during this first week. Try not to be frustrated and remember this is the first step to helping you improve your glucose control. Your first week you may want to sit back, watch and learn. Try not to over react, especially when you see those high glucose values 1 hour after a meal and are tempted to correct and take more insulin. Watch and learn is the best course for you to learn on your CGM. Consult your healthcare provider before making any adjustments to your insulin therapy. Do not use glucose readings from the Dexcom G4 PLATINUM Sensor and Transmitter to make treatment decisions, such as how much insulin to take. The BG value from your BG meter should be used for treatment decisions.

Taking the first steps. Getting to know CGM. In this course you will learn about: Calibration and accuracy Speed and direction Alert settings Troubleshooting New Sensor Session New Sensor Session Troubleshooting Alert Settings Speed and Direction Calibration and Accuracy

Calibration basics. Your Sensor does not automatically know your glucose levels. Your blood glucose (BG) meter needs to teach your Sensor what your BG levels are. You do this by calibrating. Your Sensor needs to be calibrated at least once every 12 hours (after the initial startup calibration) to keep it on track. The accuracy of your Sensor glucose readings may be compromised unless you calibrate at least once every 12 hours.

What does that number really mean? Your BG meter reading and the CGM reading on your pump may not match. That is okay. Readings can be different and still be considered accurate. CGM readings from interstitial fluid are different than BG readings from a BG meter. There are differences in how glucose is measured in the blood versus how it is measured in the fluid below the skin. And there is a lag time between when glucose is absorbed into the blood versus when it is absorbed into the fluid below the skin. This is why you will continue to use a BG meter to make treatment decisions and to calibrate the Sensor.

Teaching your Sensor. Periodic BG values from a BG meter are used to calibrate the Sensor, which adjusts Sensor readings to your body s current health status to help ensure the accuracy of the readings. TIP: Do not calibrate if your BG is changing more than 2 mg/dl per minute.

Teaching your Sensor: Example 1. Example 1: Here is an example of where the meter and CGM readings are off. Your meter reads 100 mg/dl and your CGM reads 204 mg/dl. How would you correct this? Consult your healthcare provider before making any adjustments to your insulin therapy. Do not use glucose readings from the Dexcom G4 PLATINUM Sensor and Transmitter to make treatment decisions, such as how much insulin to take. The BG value from your BG meter should be used for treatment decisions.

Teaching your Sensor: Example 1. Answer: In this situation, you should wash your hands and take a 2 nd fingerstick BG meter reading. If the value of your 2 nd fingerstick is within close range to the first, enter that number as a the calibration value into your Insulin Pump. By taking a 2 nd fingerstick, you are confirming your meter reading is accurate before you calibrate. 1 st fingerstick: 100 mg/dl 2 nd fingerstick: 106 mg/dl Consult your healthcare provider before making any adjustments to your insulin therapy. Do not use glucose readings from the Dexcom G4 PLATINUM Sensor and Transmitter to make treatment decisions, such as how much insulin to take. The BG value from your BG meter should be used for treatment decisions.

Teaching your Sensor: Example 1. After entering the 106 mg/dl into the Animas Vibe Insulin Pump, the number shifts from 204 mg/dl to 138 mg/dl. Consult your healthcare provider before making any adjustments to your insulin therapy. Do not use glucose readings from the Dexcom G4 PLATINUM Sensor and Transmitter to make treatment decisions, such as how much insulin to take. The BG value from your BG meter should be used for treatment decisions.

Teaching your Sensor: Example 2. Example 2: Here is another example where the meter and CGM are off. Your meter reads 240 mg/dl and your CGM reads 104 mg/dl. How would you correct this? Consult your healthcare provider before making any adjustments to your insulin therapy. Do not use glucose readings from the Dexcom G4 PLATINUM Sensor and Transmitter to make treatment decisions, such as how much insulin to take. The BG value from your BG meter should be used for treatment decisions.

Teaching your Sensor: Example 2. Answer: In this situation, you should wash your hands and take a 2 nd fingerstick. In this example there was something wrong with the 1st fingerstick. In this situation no action is needed. By taking the 2 nd fingerstick, you are confirming your meter reading is accurate before you calibrate. 1 st fingerstick: 240 mg/dl 2 nd fingerstick: 100 mg/dl Consult your healthcare provider before making any adjustments to your insulin therapy. Do not use glucose readings from the Dexcom G4 PLATINUM Sensor and Transmitter to make treatment decisions, such as how much insulin to take. The BG value from your BG meter should be used for treatment decisions.

Speed and direction. Your trend graph provides information regarding the speed and direction of your glucose. It is not all about the number. A 95 mg/dl value going down is different than 95 mg/dl going up. Consult your healthcare provider before making any adjustments to your insulin therapy. Do not use glucose readings from the Dexcom G4 PLATINUM Sensor and Transmitter to make treatment decisions, such as how much insulin to take. The BG value from your BG meter should be used for treatment decisions.

Speed and direction: Example 1. If you saw 95 mg/dl with two arrows pointing downwards and were about to exercise, what would you do? Eat glucose tablets (or take another form of rapid acting carbohydrate) Take insulin Do nothing Consult your healthcare provider before making any adjustments to your insulin therapy. Do not use glucose readings from the Dexcom G4 PLATINUM Sensor and Transmitter to make treatment decisions, such as how much insulin to take. The BG value from your BG meter should be used for treatment decisions.

Speed and direction: Example 1. Eat glucose tablets (or another form of rapid acting carbohydrate) may be the best option in this situation to avoid a low glucose value while exercising. Taking insulin in this situation would not be an option. Doing nothing would put you at risk for having a low glucose value while exercising based on the rapid fall rate displayed on the pump screen. Consult your healthcare provider before making any adjustments to your insulin therapy. Do not use glucose readings from the Dexcom G4 PLATINUM Sensor and Transmitter to make treatment decisions, such as how much insulin to take. The BG value from your BG meter should be used for treatment decisions.

Speed and direction: Example 2. If you saw 95 mg/dl with a slowly rising arrow and were about to exercise, what would you do? Eat glucose tablets (or take another form of rapid acting carbohydrate) Take insulin Do nothing Consult your healthcare provider before making any adjustments to your insulin therapy. Do not use glucose readings from the Dexcom G4 PLATINUM Sensor and Transmitter to make treatment decisions, such as how much insulin to take. The BG value from your BG meter should be used for treatment decisions.

Speed and direction: Example 2. Since your glucose is rising (1-2 mg/dl per min), eating glucose tablets may not be necessary in this situation. Since your glucose value is not high, taking insulin would not be appropriate in this situation. This may be the best answer considering your glucose is not too low and is rising. Consult your healthcare provider before making any adjustments to your insulin therapy. Do not use glucose readings from the Dexcom G4 PLATINUM Sensor and Transmitter to make treatment decisions, such as how much insulin to take. The BG value from your BG meter should be used for treatment decisions.

Alert settings. Your default alert settings are set at 80 mg/dl for low and 200 mg/dl for high. Sometimes these low and high alerts levels are too aggressive. This may lead to too many alerts throughout the day and may cause you frustration. When first starting on CGM, consult with your HCP on the settings that are most appropriate for you to minimize your frustration.

Alert settings. The default low and high alerts may not be the best fit for you. You should set your alerts at a level that you would want to take action. Questions to ask yourself: What glucose level would you consider treating for a low glucose value, for instance, when taking rapid acting carbohydrate? What glucose level would you consider treating for a high glucose value, for instance, when taking insulin? Tip: Set your low and high alerts at a level at which you would take action, for example when you would treat a high or a low glucose value, based on the recommendations of your HCP?

Alert settings. You may also want to adjust the default rise rate and fall rate alert settings in your Animas Vibe Insulin Pump. Remember, too many alerts during your first week on CGM may be frustrating. The rise rate and fall rate are both enabled and are set to alert you if your CGM readings begin to rise or fall at or faster than 3 mg/dl per minute. You may adjust these settings in the CGM setup menu. For example: If you do not want to get rise rate alerts at this time, change the Enable setting from Yes to No Consult your healthcare provider before making any adjustments to your insulin therapy. Do not use glucose readings from the Dexcom G4 PLATINUM Sensor and Transmitter to make treatment decisions, such as how much insulin to take. The BG value from your BG meter should be used for treatment decisions. ANM-14-4339B, 2015 Animas Corporation 2015/11 Rx Only.

Extra protection when you are very low. An additional CGM Alarm will display/sound on your pump when your most recent CGM reading is at or below 55 mg/dl. This Alarm is fixed, and cannot be changed or disabled. You will be re-alerted every 30 minutes if your current reading remains at or below 55mg/dL. This can be your safety net to help avoid hypoglycemia. Tip: The goal is to not be at 55 mg/dl. Set your low alert for a level where you will take action and not ignore it.

CGM Warning screens. These CGM Warning screens will appear on pumps intended for pediatric patients (ages 2-17). Whenever the CGM Low (Glucose) Alert is set Anytime the current CGM reading is below the low user limit and/or below 55 mg/dl

Troubleshooting. As with any device, things may go wrong. Here are some examples you may see your first week of using the Dexcom G4 PLATINUM Sensor with your Animas Vibe Insulin Pump. Unknown Glucose Reading (usually resolves itself) Out of Range (make sure pump is within 12 feet of Transmitter) For more tips on troubleshooting, refer to the Animas Vibe System Owner's Booklet and Dexcom G4 PLATINUM Sensor and Transmitter Quick Start Guide.

New Sensor session. Your Animas Vibe Insulin Pump will tell you when to change your Sensor. Sensor expiration notifications will begin to appear 6 hours before the end of your Sensor session. At 6 hours, find your new Sensor. At 2 hours, get your Sensor ready. At 30 minutes, plan for insertion of new sensor.

New Sensor session. At 0 min, take off your Sensor and put on a new one. Reminder: Do not throw out the Transmitter. If you are not able to change your Sensor immediately, that s okay, just know you won't be getting any Sensor readings until you replace your Sensor. Start your new Sensor session and approximately 2 hours later do your initial Sensor calibration.

Course summary. Thank you for viewing the First Steps for Success: Getting to know CGM training course. This course was designed to help you understand what to expect your first week on CGM. To learn more about successfully using CGM, check out the Next Steps for Success: More tips for using CGM training course at www.animas.com