CHAIN-LINK FENCES BID SPECIFICATIONS DESCRIPTION

Similar documents
AIRPORT SECURITY FENCING. A. American Society for Testing and Materials (ASTM):

SECTION CHAIN LINK FENCES AND GATES

MERCHANTS METALS SECTION ARMORLINK ALUMINIZED CHAIN LINK FENCE AND GATES 2014!

HIGH TENSION CABLE BARRIER

Fence SpecCheck Wheatland Tube Company

SECTION STORM DRAIN SYSTEM

SECTION GUARDRAILS

PTS HELICAL PIERS INSTALLATION SPECIFICATIONS NOTICE

SECTION 1 GENERAL REQUIREMENTS

SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS

WILDCAT CANYON ROAD SPECIFICATION NO SLIDE REPAIR BIDDER'S PROPOSAL (continued)

SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)

SECTION PIPE HANGERS AND SUPPORTS

DIVISION 2 - SEWERAGE AND DRAINAGE SECTION STORM DRAIN SYSTEMS PART 1 - GENERAL

SECTION STORM DRAINAGE SYSTEM

A. Contractor shall furnish, to the Engineer, all materials certifications available from the manufacturer for all required materials.

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

1.02 SYSTEM DESCRIPTION

SECTION 15 AIR RELEASE VALVE ASSEMBLIES General

Precast Manhole Sections and Castings. These items shall conform to Section 31, "Storm Drain Installation," of these Standard Provisions.

San Antonio Water System Standard Specifications for Construction ITEM NO. 854 SANITARY SEWER LATERALS

ITEM # OSTERBERG CELL LOAD TESTING OF DRILLED SHAFT

TARIFF CODE and updates standard

PART 1 GENERAL 1.1 SECTION INCLUDES

TS 813 GROUNDING AND BONDING TTD TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD CONTROLLER CABINET GROUNDING

TECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR

DENVER MODEL 30 X 30 SPECIFICATIONS

A. The shade structure contractor shall be responsible for the design, engineering, fabrication, and supply of the work specified herein.

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION PUBLIC STORM UTILITY DRAINAGE PIPING

SECTION COLD-FORMED METAL DECK FRAMING Elevations Steel Deck Framing by Trex

SECTION REMOVAL OR ABANDONMENT OF EXISTING UTILITIES AND UNDERGROUND STRUCTURES. 1. Trench excavation, backfill, and compaction; Section

TECHNICAL SPECIFICATIONS CONCRETE SIDEWALKS, DRIVEWAYS AND CURB AND GUTTER

High Strain Dynamic Load Testing of Drilled Shafts

INDEX. Sec. No. Items Page Nos.

CCU Engineering Specifications. Section PRECAST CONCRETE PRODUCTS

Specifications for Lightning Protection. ASAE Engineering Practice

Standard Specification for Polyvinyl Chloride (PVC) and Other Organic Polymer-Coated Steel Chain-Link Fence Fabric 1

A D D E N D U M # 3 QUESTIONS FROM BIDDERS: DATE: November 5, All Bidders. Jenne dos Santos, CBI Consulting Inc. City of Chelsea, MA

SECTION STORM DRAINAGE STRUCTURES. 1. Trench excavation, backfill, and compaction; Section

SECTION 36 - CAST-IN-PLACE CONCRETE PIPE (CIPCP) TABLE OF CONTENTS

SECTION SUPPORT OF EXCAVATION

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

SPECIFICATIONS. INTERLOCKING CONCRETE POROUS PAVING UNITS or Permeable Interlocking Concrete Pavers (PICP)

SECTION PRECAST CONCRETE UTILITY STRUCTURES

CITY OF SAN ANTONIO. Issued By: Transportation and Capital Improvements Date Issued: February 10, 2016 ID NO.:

SECTION UNDERGROUND ELECTRIC SERVICE

3. Contractor shall ensure that all permits are obtained prior to any construction. Contractor shall be responsible for all utility fees.

MANUFACTURED HOUSING USED AS DWELLINGS

TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE

SECTION 6 SANITARY SEWER MAIN 6.01 SCOPE

GUIDELINES FOR UTILITY INSTALLATIONS Part 1 - Wire Lines and Communications Cables

SECTION PRECAST CONCRETE STRUCTURES

Section SEWER PIPE INSTALLATION AND TESTING

SAMPLE GUIDE SPECIFICATIONS FOR OSTERBERG CELL LOAD TESTING OF DEEP FOUNDATIONS

CONSTRUCTION OF PERIMETER FENCE - COMMERCIAL AND T&D OFFICE COMPOUND, ONVERWAGT

ATLANTA MODEL SPECIFICATIONS

SECTION CABLE TRAYS. A. Continuous, rigid, welded steel or stainless steel wire mesh cable management system.

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

1.02 DESCRIPTION A. This Section specifies furnishing and installing Cast in Place Detectable/Tactile Warning Surface tiles where indicated.

STANDARD AND SPECIFICATIONS FOR STORM DRAIN INLET PROTECTION

Mobile Home Pre-Inspection Checklist

State of Illinois Department Of Transportation CONSTRUCTION INSPECTOR S CHECKLIST FOR STORM SEWERS

San Antonio Water System Standard Specifications for Construction ITEM NO SLIP-LINING SANITARY SEWERS

Display hidden notes to specifier. (Don't know how? Click Here) A. Advanced Upcoiling Security Grilles, power operated.

GUARDRAIL POST STEEL

Preformed Metal Roofing and Siding

Specifications. Preformed Metal Wall and Roof Panels. Alcoa Cladding Systems Manufacturing Plant 100 Industrial Boulevard Eastman, Georgia 31023

COLORADO MODEL. 35 x 65 SPECIFICATIONS

FORM DESIGN. easy to work with, and generally available.

SECTION 807 PUMP STATION REHABILITATION

STANDARD SPECIFICATIONS FOR PRIVATE BUILDING SEWER LINES IN PUBLIC RIGHT-OF-WAY

The work of this Section includes furnishing and installing Reinforced Concrete Pressure Pipe as shown on the Drawings and as specified.

Acceptance Codes APPENDIX - A. Acceptance Criteria

SEPTIC SYSTEM CONSTRUCTION REQUIREMENTS ST. MARY S COUNTY HEALTH DEPARTMENT

Copper and Copper Alloy Tube, Pipe and Fittings

Storm Drain Inlet Protection - IP

Specification Guidelines: Allan Block Modular Retaining Wall Systems

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued November 1, Legacy report on the 1997 Uniform Building Code

SECTION PREFORMED METAL STANDING SEAM ROOFING PART 1 - GENERAL 1.1 DESCRIPTION OF WORK

SECTION WINDOW WASHING SYSTEMS

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 11/5/13)

PROJECT TITLE : 2-STOREY RESIDENCE LOCATION : ALONG DAANG HARI,MOLINO.BACOOR,CAVITE OWNER : CUEVASVILLE REALTY

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

Table 4.9 Storm Drain Inlet Protetion Applicable for

ARTICLE II (2) ARTICLE II - REQUIRED USE OF PUBLIC SEWERS. PARAGRAPH Purpose and Application.

CORROSION ENGINEERING RESIN-BASED POLYMER CONCRETES AND GROUTS

Wastewater Capital Projects Management Standard Construction Specification

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

MHD BRIDGE SECTION WEIGHTED AVERAGE UNIT PRICES GUIDELINES FOR THE USE OF THE WEIGHTED AVERAGE UNIT PRICE TABULATION SHEETS

Sports and High Mast Lighting Poles Phone: (866) Fax: (817)

SECTION GROUND WATER STORAGE TANKS

SECTION EARTH MOVING

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

SECTION STORM DRAINAGE TABLE OF CONTENTS

Proposed Minimum Subterranean Termite Treatment Standards

SECTION LS 2530 SANITARY SEWERS. A. General: Submit the following in accordance with The General Conditions.

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

Transcription:

CHAIN-LINK FENCES BID SPECIFICATIONS DESCRIPTION 1 This item shall consist of furnishing and erecting Chain-Link fence in accordance with these specifications and the details shown on the plans and in conformity with the lines and grades shown on plans or established by the Engineer. Contractor shall submit shop drawings on all fencing and gates. MATERIALS 2 FABRIC. The fabric shall be woven with a 9-gauge galvanized steel wire in a 2-inch mesh and shall meet the requirements of galvanized steel fabric and conform to the requirements of ASTM A 392, Class 2. 3 BARBED WIRE. Barbed wire shall be 2-strand 12-1/2 gauge zinc-coated wire with 4-point barbs and shall conform to the requirements of zinc-coated barbed wire shall conform to the requirements of ASTM A 121, Class 3, Chain-Link Fence Grade. 4 POSTS, RAILS AND BRACES. Line posts, rails, and braces shall conform to the requirements of AST- F-1043 or ASTM F 1083 as follows: Galvanized tubular steel pipe shall conform to the requirements of Group IA, (Schedule 40) coatings conforming to Type A, or Group IC (High Strength Pipe), External coating Type B, and internal coating Type B or D. Posts, rails, and braces furnished for use in conjunction with aluminum alloy fabric shall be aluminum alloy or composite. Posts, rails, and braces, with the exception of galvanized steel conforming to F 1043 or ASTM F 1083, Group 1A, Type A, or aluminum alloy, shall demonstrate the ability to withstand testing in salt spray in accordance with ASTM B 117 as follows: External: 1,000 hours with a maximum of 5% red rust Internal: 650 hours with a maximum of 5% red rust. The dimensions of the posts, rails, and braces shall be in accordance with Tables 1 through VI of Fed. Spec. RR-F-191/3D. Where called for, reflective tape is to be placed completely around posts (top, middle, and bottom). Tape shall be Scotchlite (or approved equal) Reflective Conspicuity Marking, 11-inch red and 7-inch white meeting ASTM D4956-93B Type V and NHTSA conspicuity regulation: LS300-CFP92. Tape is to be considered incidental to the project. 5 GATES. Gate frames shall consist of galvanized tubular steel pipe and shall conform to the specifications for the same material under paragraph 162-2.3. The fabric shall be of the same type material as used in the fence. 1

6 WIRE TIES AND TENSION WIRES. Wire ties for use in conjunction with a given type of fabric shall be of the same material and coating weight identified with the fabric type. Tension wire shall be 7-gauge marcelled steel wire with the same coating as the fabric type and shall conform to ASTM A 824. All material shall conform to Fed. Spec. RR-F-191/4D 7 MISCELLANEOUS FITTINGS AND HARDWARE. Miscellaneous steel fittings and hardware for use with zinc-coated steel fabric shall be of commercial grade steel or better quality, wrought or cast as appropriate to the article, and sufficient in strength to provide a balanced design when used in conjunction with fabric posts, and wires of the quality specified herein. Barbed wire support arms shall withstand a load of 50 pounds (113 kg) applied vertically to the outermost end of the arm. 8 CONCRETE. Concrete shall be of a commercial grade with a minimum 28-day compressive strength of 2500 psi (17 240 kpa). 9 MARKING. Each roll of fabric shall carry a tag showing the kind of base metal (steel, aluminum, or aluminum alloy number), kind of coating, the gauge of the wire, the length of fencing in the roll, and the name of the manufacturer. Posts, wire, and other fittings shall be identified as to manufacturer, kind of base metal (Steel, aluminum, or aluminum alloy number), and kind of coating. CONSTRUCTION METHODS 10 CLEARING FENCE LINE. All trees, brush, stumps, logs, and other debris which would interfere with the proper construction of the fence in the required location shall be removed a minimum width of 2 feet (61 cm) on each side of the fence centerline before starting fencing operations. The cost of removing and disposing of the material shall not constitute a pay item and shall be considered incidental to fence construction. 11 INSTALLING POSTS. All posts shall be set in concrete at the required dimension and depth and at the spacing shown on the plans. Posts should be spaced not more than 10 feet (3 m) apart and should be set a minimum of 36 inches (90 cm) in concrete footings. If the frost depth is greater than 36 inches (90 cm), the posts should be set accordingly. The posts holes shall be in proper alignment so that there is a minimum of 3 inches (75 mm) of concrete on all sides of the posts. The concrete shall be thoroughly compacted around the posts by tamping or vibrating and shall have a smooth finish slightly higher than the ground and sloped to drain away from the posts. All posts shall be set plumb and to the required grade and alignment. No materials shall be installed on the posts, nor shall the posts be disturbed in any manner within 7 days after the individual post footing is completed. Should rock be encountered at a depth less than the planned footing depth, a hole 2 inches (50 mm) larger than the greatest dimension of the posts shall be drilled to a depth of 12 inches (300 mm). After the posts are set, the remainder of the drilled hole shall be filled with grout, 2

composed of one part Portland cement and two parts mortar sand. Any remaining space above the rock shall be filled with concrete in the manner described above. In lieu of drilling, the rock may be excavated to the required footing depth. No extra compensation shall be made for rock excavation. 12 INSTALLING TOP RAILS. The top rail shall be continuous and shall pass through the post tops. The coupling used to join the top rail lengths shall allow for expansion. 13 INSTALLING BRACES. Horizontal brace rails, with diagonal truss rods and turnbuckles, shall be installed at all terminal posts. 14 INSTALLING FABRIC. The wire fabric shall be firmly attached to the posts and braced in the manner shown on the plans. All wire shall be stretched taut and shall be installed to the required elevations. The fence shall generally follow the contour of the ground, with the bottom of the fence fabric no less than 1 inch (25 mm) or more than 4 inches (100mm) from the ground surface. Grading shall be performed where necessary to provide a neat appearance. At locations of small natural swales or drainage ditches and where it is not practical to have the fence conform to the general contour of the ground surface, longer posts may be used and multiple strands of barbed wire stretched thereon to span the opening below the fence. The vertical clearance between strands of barbed wire shall be 6 inches (150 mm) or less. 15 ELECTRICAL GROUNDS. Electrical grounds shall be constructed where a power line passes over the fence and at 500-foot (150 m) intervals. The ground shall be installed directly below the point of crossing. The ground shall be accomplished with a copper clad rod 8 feet (240 cm) long and a minimum of 5/8 inch (15 mm) in diameter driven vertically until the top is 6 inches (150 mm) below the ground surface. A No. 6 solid copper conductor shall be clamped to the rod and to the fence in such a manner that each element of the fence is grounded. Installation of ground rods shall not constitute a pay item and shall be considered incidental to fence construction. BASIS OF PAYMENT 16 Payment will be made at the contract bid price. The price shall be full compensation for furnishing all materials, and for all preparation, erection, and installation of these materials, and for all labor equipment, tools, and incidentals necessary to complete the item. MATERIAL REQUIREMENTS ASTM A 121 Zinc-coated (Galvanized) Steel Barbed Wire ASTM A 123 Zinc (Hot Galvanized) Coatings on Products Fabricated from Rolled, Pressed, and forged Steel Shapes, Plates, Bars, and Strip ASTM A 153 Zinc Coating (Hot-Dip) on Iron and Steel Hardware ASTM A 392 Zinc-Coated Steel Chain-Link Fence Fabric 3

ASTM A 446 Specification for Steel Sheet, Zinc-Coated (Galvanized) by the Hot-Dip Process, Structural (Physical) Quality ASTM A 491 Aluminum-Coated Steel Chain-Link Fence ASTM A 569 Steel, Carbon (0.15 Maximum, Percent), Hot Rolled Sheet and Strip Commercial Quality ASTM A 570 Hot-Rolled Carbon Steel Sheet and Strip Structural Quality ASTM A 572 High-Strength Low-Alloy Columbium-Vanadium Steels of Structural Quality ASTM A 585 Aluminum-Coated Steel Barbed Wire ASTM F 668 Poly (Vinyl Chloride)(PVC)-Coated Steel Chain-Link Fence ASTM F 1043 Strength and Protective Coatings on Metal Industrial Chain-Link Fence Framework ASTM F 1083 Pipe, Steel, Hot-Dipped Zinc-Coated (Galvanized) Welded, for Fence Structures ASTM F 1183 Aluminum Alloy Chain-Link Fence Fabric ASTM F 1234 Protective Coatings on Steel Framework for Fences Fed. Spec. Fed. Spec. Fencing, Wire and Post, Metal (Chain-Link Fence Posts, Top Rails and braces) RR-F-191/3D Fencing, Wire and Post, Metal (Chain-Link Fence Accessories) RR-F- 191/4D 4

5

NOTICE TO VENDORS Sealed proposals including vendor name and address will be received by the City of Lafayette, at the office of the City of Lafayette Recorder s Office, 200 East Locust St., Lafayette, TN 37083, the hour 2:00 p.m., on the 6 th, day of March 2012 at which time proposals duly delivered and submitted. Until the final award by the City of Lafayette, said city reserves the right to reject any and/or all proposals, to waive technicalities, to re-advertise, to proceed otherwise when the best interests of the City will be realized hereby. Proposals will be submitted sealed and plainly marked with the date and time of receipt. The City of Lafayette does not discriminate based on race, color or national origin in federal or state sponsored programs, pursuant to Title VI of the Civil Rights Act of 1964 (42 U.S.C. 2000d).With regard to all aspects of this contract, contractor certifies and warrants it will comply with this policy. Bidder Phone: Address: Bid : CITY OF LAFAYETTE CONTRACT MONITORING TDOT requires that sub-recipients maintain records of those ethnic and gender groups who are awarded bids on projects. For Title VI compliance, we ask for voluntary disclosure of the following information: Gender: Male Race: Female Caucasian African American Hispanic American Indian and Alaskan Native Native Hawaiian or other Pacific Islander Other (please specify) 6