Preservation By Design

Similar documents
Laboratory Solutions. Optimization By Design

Smile Confidently With DIEM 2. Immediate Full Arch Rehabilitation

Encode Impression System. Optimization By Design

Don t Let Life Pass You By Because Of Missing Teeth

Don t Let Life Pass You By Because Of Oral Bone Loss

Dental Implant System Design and the Potential Impact on Long-Term Aesthetics: A Review of the 3i T3 Tapered Implant

Laboratory Designed Abutment. Optimization By Design

Histologic comparison of biologic width around teeth versus implants: The effect on bone preservation

Dynamic Loading Fluid Leakage Characterization of Dental Implant Systems

SPECIAL SUPPLEMENT. Inside this issue: 2014 No. 2. Abstracts from Selected Publications and Poster Presentations BIOMET 3i T3 Implants

Better For Your Patients, Better For Your Practice

Clinical and Laboratory Procedures for Fixed Margin Implant Abutments

1 The Single Tooth Implant. The Ultimate Aesthetic Challenge

Straumann Dental Implant System. Implant Selection Guide.

Prosthetic treatment planning on the basis of scientific evidence.

Ridge Reconstruction for Implant Placement

Clinical Indications For Immediate Restoration Of Implants Using PreFormance Provisional Components

Dental Implant Restoration

Healing Abutment Selection. Perio Implant Part I. Implant Surface Characteristics. Single Tooth Restorations. Credit and Thanks for Lecture Material

Accelerated Patient Rehabilitation

Supervisors: Dr. Farhan Raza Khan

IMMEDIATE CUSTOM IMPLANT PROVISIONALIZATION: A PROSTHETIC TECHNIQUE

CUSTOMIZED PROVISIONAL ABUTMENT AND PROVISIONAL RESTORATION FOR AN IMMEDIATELY-PLACED IMPLANT

Reconstruction of the anterior maxilla with implants using customized zirconia abutments and all-ceramic crowns: a clinical case report

Mastering aesthetics in post-extraction sites Ronnie J. Goené, DMD and Alwin C.L. van Daelen, DMD. Special Reprint, JIRD Vol. 4, No.

education Although demographic factors and growing patient awareness of the benefits of dental implants

Photoelastic Comparison of Single Tooth Implant-Abutment-Bone of Platform Switching vs Conventional Implant Designs

Clinical Perspectives

Saudi Fellowship In Dental Implant (SF-DI)

While the prosthetic rehabilitation of

TRI Product NewsFlash. December 2015

Standard Internal Hex

REALITIES AND LIMITATIONS IN THE MANAGEMENT OF THE INTERDENTAL PAPILLA BETWEEN IMPLANTS: THREE CASE REPORTS

Dental Implant Options in Atrophic Jaws

Contact: Steve Hurson VP, R & D Nobel Biocare Savi Ranch Pkwy Yorba Linda, CA (714) steve.hurson@nobelbiocare.

Replacement of a single front tooth Surgical procedure and three-year results

Modern Tooth Replacement Strategies & Digital Workflow

Straumann. Time-tested

THE EVOLUTION OF EXTERNAL AND INTERNAL IMPLANT/ABUTMENT CONNECTIONS

Retrospective study on the survival rate of IBS implant

Implant platform switching concept: An updated review

CPD Article ISSUE 15. Proud of our History, Looking Forward to the Future

IMMEDIATE OCCLUSAL LOADING

The SATURN implant by Cortex Dental Industries

Amajor limitation in the use of most

All-on-4 treatment concept with NobelSpeedy Groovy

RESEARCH. Key Words: crown-implant ratios, proximal bone-to-implant contact. Journal of Oral Implantology 425

Restoring missing teeth in the anterior maxilla with

More than an implant. A sense of trust. Straumann Dental Implant System

Many factors must be considered when

More than a fixed rehabilitation.

Redesign of a fixture mount to be used as an impression coping and a provisional abutment as well

Powertome Assisted Atraumatic Tooth Extraction

Replacement of the upper left central incisor with a Straumann Bone Level Implant and a Straumann Customized Ceramic Abutment

Quality from Switzerland

Improving Esthetics with Sequential Treatment Planning and Implant-Retained Dentures

The predictability of attaining osseointegration

ALL-CERAMIC DENTAL IMPLANT SOLUTIONS

Objective Criteria: Guiding and Evaluating Dental Implant Esthetics

The Institute for Implant and Reconstructive Dentistry Presents: The Lazzara Educational Webinar Series

Long-Term dental Implant Survival In Fully Endentulous Patients: A Month Follow-Up

Dental Implant Treatment after Improvement of Oral Environment by Orthodontic Therapy

Evolution through science ASTRA TECH Implant System EV

IMPLANTS IN FOCUS. Endosseous dental implant restorations PLANNING FOR IMPLANT RESTORATIONS

Straumann Bone Level Tapered Implant Peer-to-peer communication

Replacing Hopeless Retained Deciduous Teeth in Adults Utilizing Dental Implants: Concepts and Case Presentation

IMPLANT CONSENT FORM WHAT ARE DENTAL IMPLANTS?

The Surface and Material of Dental Implants

MAIN LINE DENTAL IMPLANT CENTER

Tissue alterations at implant-supported single-tooth replacements: a 1-year prospective clinical study

BioHorizons Education Programme 2015

ATLANTIS ISUS the benchmark for CAD/CAM suprastructures. For all major implant systems

Renaissance of One-Piece Implants

The immediate post-extractional insertion of screw implants in dental practice

Residency Competency and Proficiency Statements

Dental Implant Interventions - A Review

USE OF DENTAL IMPLANTS IN THE NAVY MEDICAL HEALTH CARE SYSTEM

The management of immediate implant placement to optimize aesthetic outcome in the anterior maxilla

Radiographic Vertical Bone Loss Evaluation around Dental Implants Following One Year of Functional Loading

Bone augmentation procedure without wound closure

IMPLANT DENTISTRY EXAM BANK

PATIENT INFORM CONSENT for IMPLANT RESTORATION Rev

Osseointegrated dental implants traditionally

IMPLANT DENTISTRY CLINICAL SYLLABUS

Implants in your Laboratory: Abutment Design

BONE LEVEL IMPLANT SCIENTIFIC OVERVIEW

IMPLANT MENTOR PROGRAM

E. Richard Hughes, D.D.S.

The Chairside Fabrication of a Provisional Crown for a Single Tooth Implant

Soft tissue stability at the facial aspect of gingivally converging abutments in the esthetic zone: A pilot clinical study

The Immediate Placement of Dental Implants Into Extraction Sites With Periapical Lesions: A Retrospective Chart Review

Immediate Provisionalization of Dental Implants Placed in Healed Alveolar Ridges and Extraction Sockets: A 5-year Prospective Evaluation

Rehabilitation of Endondontically Failed Anterior teeth by Immediate Replacement and Loading of an Implant supported Crown: A Case Report.

Instructions For Use:

Straumann Dental implant system ONE SYSTEM ONE INSTRUMENT KIT ALL INDICATIONS*

Clinical and scanning electron microscopic analysis of fractured dental implants: a retrospective clinical analysis

BICON DENTAL IMPLANTS

GIVE YOUR PATIENTS THE FREEDOM TO EAT, SPEAK AND LAUGH AGAIN.

Curriculum Vitae Frank L. Higginbottom, D.D.S.

Implant Replacement of the Maxillary Central Incisor Utilizing a Modified Ceramic Abutment (Thommen SPI ART) and Ceramic Restoration

Transcription:

Preservation By Design

Preservation Is Key To Aesthetics Traditional challenges to aesthetic outcomes: Introducing The Designed To Deliver Aesthetic Results Through Tissue Preservation Delayed Osseointegration Implants lacking a complex surface topography 1 and primary stability require more time for osseointegration. 2 Contemporary Hybrid Surface Provided by complex multi-surface topography Seal Integrity Peri-implantitis The prevalence of implants experiencing peri-implantitis has been reported in excess of 12%. 3,4 Provided by a stable and tight implant/abutment interface Integrated Platform Switching Provided by a medialized implant/abutment junction Crestal Bone Loss Average implant crestal bone remodeling can exceed 1.5mm following the first year of function, leading to compromised aesthetics. 5

Contemporary Hybrid Design Primary stability 6,7,8 Initial Bone-to-Implant Contact is a major contributor to the implant s stability. 9 The specifications of the 3i T3 Implant are held to rigorous tolerances to provide a closely integrated implant-to-osteotomy fit, creating a dental implant system that helps to achieve primary stability. Osseointegration 10,11 In preclinical studies*, the 3i T3 with DCD Surface demonstrated increased integration strength throughout the healing phase as compared to less complex surface topographies. 11 No Increased Peri-implantitis risk 12,13 The 3i T3 Implant utilizes the proven OSSEOTITE Surface technology at the coronal aspect of the implant. In a five-year study **, the dual acid-etched surface of the OSSEOTITE Implant presented no increased risk of peri-implantitis or softtissue complications versus a machined surface. 12 Coarse And Fine Micron Surface Features Create An Average Mean Surface Roughness Value Of 1.4μm 14 Coarse and fine micron features Coarse: (10+ microns) via resorbable calcium phosphate media blast Fine: (1-3 microns) via dual acid-etching (DAE) on top of the blasted surface Option for nano-scale features along the full length of the implant via Discrete Crystalline Deposition (DCD) of calcium phosphate Fine micron features on the implant collar (1-3 microns) via dual acid-etching (DAE) Multicenter, randomized controlled 5-year study of hybrid and fully etched implants for the incidence of peri-implantitis ** % Sulcus Bleeding Index* Hybrid Surface Design Full DAE Surface Design SBI Scores # of Sites Probed Probing Depth Scores* Hybrid Surface Design Full DAE Surface Design Probing Depths: Change from baseline (mm) * Preclinical studies are not necessarily indicative of clinical performance. 84% of all SBI scores were 0 (absence of bleeding); 13% of scores were 1 - isolated bleeding spot. No implant (test or control) showed changes in probing depths greater than 3.0mm. ** Zetterqvist et al. A Prospective, Multicenter, Randomized Controlled 5-Year Study Of Hybrid And Fully Etched Implants For The Incidence Of Peri-implantitis. J Periodontol April 2010. One hundred twelve patients who were enrolled at seven centers received 139 control and 165 test implants (total: 304 implants).

Seal Integrity 800 700 Seal Integrity Dynamic Fluid Leakage Testing (Leak or Fracture) A stable, tight implant/abutment interface minimizes abutment micromotion and reduces potential microleakage. 15 Implant/abutment seal strength Newtons 600 500 400 300 200 100 Competitor 1 16 Competitor 2 16 Competitor 3 16 BIOMET 3i T3 with DCD Implant 17 with Platform Swtiching, BNPT4315 Designed to reduce microleakage through exacting interface tolerances and maximized clamping forces. Seal integrity test was performed by BIOMET 3i July 2011 - June 2012. In order to test the implant systems, a dynamic - loading leakage test was developed and executed. The test set-up was adapted from ISO14801, Dentistry - Implants - Dynamic Fatigue Test for Endosseous Dental Implants. Five samples each of the BIOMET 3i and three competitive implant systems were evaluated. The mean seal strength (N) at which each of the systems leaked or fractured is detailed in the graph. Bench test results are not necessarily indicative of clinical performance. Implant/abutment clamping force Use of the Gold-Tite Screw increases Certain Implant/ abutment clamping force by 113% vs. a non-coated screw. 18 Patented* Gold-Tite Surface lubrication allows the screw to rotate further, increasing clamping force and maximizing abutment stability. 19 Implant Screw *USPTO 6287116 and additional patents pending. Integrated Platform Switching Bone remodeling with integrated platform switching Integrated platform switching medializes the implant/abutment junction (IAJ) inward, creating a biologic width between connective tissue and the IAJ, helping to maintain bone levels. 20 Reduced crestal bone loss Studies show implants with the BIOMET 3i integrated platform switching feature demonstrated crestal bone loss as low as 0.37mm.** 21 Reduction in crestal bone remodeling vs. non platformswitched implants 22 A medialized implant/abutment junction provides support for connective tissue, reducing the potential for recession by 50%.** Image courtesy of Dr. Xavier Vela, Spain. 3.4mm 4mm **Results are not necessarily typical, indicative or representative of all recipient patients.

With DCD Implant Clinical Case Presentation Clinical Treatment by Dr. Tiziano Testori & Dr. Fabio Scutellá Fig. 1 Hopeless central incisors. Fig. 2 Two 3i T3 DCD Tapered Implants x 13mm(L) placed immediately after extractions. Fig. 3 Two PreFormance Provisional Posts adjusted intraorally. Fig. 4 An acrylic-resin splinted provisional restoration was cemented to the PreFormance Posts. Fig. 5 One month follow-up. Fig. 6 Final result with definitive prosthesis six months post-extractions and implant placement. Note the maintenance of the facio-palatal width. Fig. 7 Periapical at six months follow-up showing bone preservation both distally and mesially. Fig. 8 Cone beam images at six months. Note the facial wall thickness is maintained at 2.7mm.

References 1. Sullivan DY, Sherwood RL, Porter SS. Long-term performance of OSSEOTITE Implants: A 6-year follow-up. Compendium. 2001 Apr;Vol.22, No.4. 2. Javed F, Romanos GE. The role of primary stability for successful immediate loading of dental implants. A literature review. J Dent. 2010 Aug;38(8):612-20. Epub 2010 Jun 11. Review. 3. Fransson C, Lekholm U, Jemt T, Berglundh T. Prevalence of subjects with progressive bone loss at implants. Clinical Oral Implants Research. 2005;16:440 446. 4. Zitzmann NU, Berglundh T. Definition and prevalence of peri-implant diseases. J Clin Perio. 2008;35:286 291. 5. Lazzara RJ, Porter SS. Platform Switching: A new concept in implant dentistry for controlling post restorative crestal bone levels. Int J Periodontics Restorative Dent. 2006;26:9-17. 6. Östman PO, Wennerberg A, Ekestubbe A, et al. Immediate occlusal loading of NanoTite tapered implants: A prospective 1-year clinical and radiographic study. Clin Implant Dent Relat Res. 2012 Jan 17. 7. Block MS. Placement of implants into fresh molar sites: Results of 35 cases. J Oral Maxillofac Surg. 2011 Jan;69(1):170-174. 8. Meltzer AM. Immediate implant placement and restoration in infected sites. Int J Periodontics Restorative Dent. 2012 Oct;32(5):e169-173. 9. Meredith N. Assessment of implant stability as a prognostic determinant. Int J Prosthodont. 1998 Sep-Oct;11(5):491-501. 10. Nevins M, Nevins ML, Schupbach P, Fiorellini J, Lin Z, Kim DM. The impact of bone compression on bone-to-implant contact of an osseointegrated implant: A canine study. Int J Periodontics Restorative Dent. 2012 Dec;32(6):637-645. 11. Mendes V, Davies JE. Early Implant healing at implant surfaces of varying topographical complexity. Poster Presentation: Academy of Osseointegration, 26th Annual Meeting; March 2011; Washington, DC. http://biomet3i.com/pdf/posters/poster_ Early_Periimplant_Healing.pdf. 12. Zetterqvist L, Feldman S, Rotter B, et al. A prospective, multicenter, randomized-controlled 5-year study of hybrid and fully etched implants for the incidence of peri-implantitis. J Periodontol. 2010 April;81:493-501. 13. Lang NP, Berglundh T. Periimplant diseases: Where are we now?-consensus of the Seventh European Workshop on Periodontology; Working Group 4 of Seventh European Workshop on Periodontology. J Clin Perio. 2011 Mar;38 Suppl 11:178-181. 14. Gubbi P, Towse R, Quantitative and qualitative characterization of various dental implant surfaces. Poster Presentation P421: European Association For Osseointegration, 20th Meeting; October 2012; Copenhagen, Denmark. (http://www.biomet3i.com/pdf/ Posters/Poster_421_EAO_Final.pdf). 15. Lazzara R. Dental implant system design and the potential impact on long-term aesthetics: A review of the 3i T3 Tapered Implant. ART1193EU BIOMET 3i White Paper. BIOMET 3i, Palm Beach Gardens, Florida, USA. http://biomet3i.com/pdf/emea/art1193c_ T3%20Implant_White_Paper_EU.pdf 16. Suttin et al. A novel method for assessing implant-abutment connection seal robustness. Poster Presentation: Academy of Osseointegration, 27th Annual Meeting; March 2012; Phoenix, AZ. http://biomet3i.com/pdf/posters/poster_seal%20study_zs_ao2012_no%20logo.pdf 17. Suttin Z, Towse R. Dynamic loading fluid leakage characterization of dental implant systems. ART1205EU BIOMET 3i White Paper. BIOMET 3i, Palm Beach Gardens, Florida, USA. http://biomet3i.com/pdf/emea/art1205eu%20dynamic%20loading%20t3%20white%20paper.pdf 18. Suttin Z, Towse R. Effect of abutment screw design on implant system seal performance. Presented at the European Association for Osseointegration, 20th Annual Scientific Meeting; October 2012; Copenhagen, Denmark. http://biomet3i.com/pdf/ Posters/P-450_Effect_of_Screw_Design_on_Implant_Seal.pdf 19. Byrne D, Jacobs S, O Connell B, Houston F, Claffey N. Preloads generated with repeated tightening in three types of screws used in dental implant assemblies. J. Prosthodont. 2006 May Jun;15(3):164-171. 20. Lazzara RJ, Porter SS. Platform switching: A new concept in implant dentistry for controlling postrestorative crestal bone levels. Int J Perio Rest Dent. 2006;26:9-17. 21. Östman PO, Wennerberg A, Albrektsson T. Immediate occlusal loading of NanoTite prevail implants: A prospective 1-year clinical and radiographic study. Clin Implant Dent Relat Res. 2010 Mar;12(1):39-47. 22. Boitel N, Andreoni C, Grunder U, Naef R, Meyenberg K. A three year prospective, multicenter, randomized-controlled study evaluating platform-switching for the preservation of peri-implant bone levels. Poster Presentation P83: Academy of Osseointegration, 26th Annual Meeting: 2011 March 3-5; Washington DC. http://biomet3i.com/resource%20center/ Publications%20of%20Interest/Platform_Switching_for_the_Preservation_of%20Peri_Implant%20Bone%20Levels.pdf Dr. Block, Dr. Goené, Dr. Grunder, Dr. Lazzara, Dr. Makigusa, Dr. Meltzer, Dr. Méndez, Dr. Meyenberg, Dr. Nevins, Dr. Östman, Dr. Rodríguez, Dr. Segalá, Dr. Scutellá, Dr. Tarnow, Dr. Testori and Dr. Vela have financial relationships with BIOMET 3i LLC resulting from speaking engagements, consulting engagements and other retained services. Dr. Gubbi, Mr. Suttin and Mr. Towse contributed to the above research while employed by BIOMET 3i. References 6 10 discuss the BIOMET 3i Tapered Implant macrodesign, which is incorporated into the 3i T3 Implant. References 10 13 discuss the BIOMET 3i OSSEOTITE and/or NanoTite Implants dual acid-etched or DCD technology, which is incorporated into the 3i T3 Implant. References 20 22 discuss BIOMET 3i PREVAIL Implants with an integrated platform switching design, which is also incorporated into the 3i T3 Implant.

Introducing The Designed To Deliver Aesthetic Results Through Tissue Preservation Contemporary Hybrid Surface Provided by complex multi-surface topography Seal Integrity Provided by a stable and tight implant/abutment interface Integrated Platform Switching Provided by a medialized implant/abutment junction

(D) = Diameter (P) = Platform Ordering Information Tapered Implants 3i T3 3i T3 Non-Platform Switched 3.2 6mm(P) 8.5mm BOPT4385 BOPT5485 BOPT6585 8.5mm BOST3285 BOST485 BOST585 BOST685 10mm BOPT4310 BOPT5410 BOPT6510 10mm BOST3210 BOST410 BOST510 BOST610 11.5mm BOPT4311 BOPT5411 BOPT6511 11.5mm BOST3211 BOST411 BOST511 BOST611 13mm BOPT4313 BOPT5413 BOPT6513 13mm BOST3213 BOST413 BOST513 BOST613 BOPT4313 15mm BOPT4315 BOPT5415 BOPT6515 3i T3 With DCD BOST413 15mm BOST3215 BOST415 BOST515 BOST615 3i T3 Non-Platform Switched With DCD 3.2 6mm(P) 8.5mm BNPT4385 BNPT5485 BNPT6585 8.5mm BNST3285 BNST485 BNST585 BNST685 10mm BNPT4310 BNPT5410 BNPT6510 10mm BNST3210 BNST410 BNST510 BNST610 11.5mm BNPT4311 BNPT5411 BNPT6511 11.5mm BNST3211 BNST411 BNST511 BNST611 13mm BNPT4313 BNPT5413 BNPT6513 13mm BNST3213 BNST413 BNST513 BNST613 15mm BNPT4315 BNPT5415 BNPT6515 15mm BNST3215 BNST415 BNST515 BNST615 BOPS4313 3i T3 8.5mm BOPS4385 BOPS5485 BOPS6585 10mm BOPS4310 BOPS5410 BOPS6510 11.5mm BOPS4311 BOPS5411 BOPS6511 13mm BOPS4313 BOPS5413 BOPS6513 15mm BOPS4315 BOPS5415 BOPS6515 3i T3 With DCD Parallel Walled Implants 8.5mm BNPS4385 BNPS5485 BNPS6585 10mm BNPS4310 BNPS5410 BNPS6510 11.5mm BNPS4311 BNPS5411 BNPS6511 13mm BNPS4313 BNPS5413 BNPS6513 15mm BNPS4315 BNPS5415 BNPS6515 BOSS413 3i T3 Non-Platform Switched 3.2 6mm(P) 8.5mm BOSS385 BOSS485 BOSS585 BOSS685 10mm BOSS310 BOSS410 BOSS510 BOSS610 11.5mm BOSS311 BOSS411 BOSS511 BOSS611 13mm BOSS313 BOSS413 BOSS513 BOSS613 15mm BOSS315 BOSS415 BOSS515 BOSS615 18mm BOSS318 BOSS418 N/A N/A 3i T3 Non-Platform Switched With DCD 3.2 6mm(P) 8.5mm BNSS385 BNSS485 BNSS585 BNSS685 10mm BNSS310 BNSS410 BNSS510 BNSS610 11.5mm BNSS311 BNSS411 BNSS511 BNSS611 13mm BNSS313 BNSS413 BNSS513 BNSS613 15mm BNSS315 BNSS415 BNSS515 BNSS615 18mm BNSS318 BNSS418 N/A N/A For More Information, Please Contact Your Local BIOMET 3i Sales Representative. Global Headquarters 4555 Riverside Drive Palm Beach Gardens, FL 33410 1-800-342-5454 Outside the U.S.: +1-561-776-6700 Fax: +1-561-776-1272 www.biomet3i.com EC REP BIOMET 3i Europe, Middle East & Africa WTC Almeda Park, Ed. 1, Planta 1ª Pl. de la Pau, s/n 08940, Cornellà de Llobregat (Barcelona) Spain Phone: +34-93-470-55-00 Fax: +34-93-371-78-49 3i T3, BellaTek design, DCD, Encode, GingiHue, Gold-Tite, OSSEOTITE, PreFormance, Preservation By Design and PREVAIL are registered trademarks of BIOMET 3i LLC. 3i T3 Implant design and Providing Solutions - One Patient At A Time are trademarks of BIOMET 3i LLC. Endobon is a registered trademark of BIOMET Deutschland. 2014 BIOMET 3i LLC. All trademarks herein are the property of BIOMET 3i LLC unless otherwise indicated. This material is intended for clinicians only and is NOT intended for patient distribution. This material is not to be redistributed, duplicated, or disclosed without the express written consent of BIOMET 3i. For additional product information, including indications, contraindications, warnings, precautions, and potential adverse effects, see the product package insert and the BIOMET 3i Website: www.ifu.biomet3i.com. ART1190 REV D 04/14