Dried Blood Spot Specimens for Serological Testing of Rodents

Similar documents
STANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA

Talk to the animals: biosecurity from a rodent s point of view

Lyme (IgG and IgM) Antibody Confirmation

4A. Types of Laboratory Tests Available and Specimens Required. Three main types of laboratory tests are used for diagnosing CHIK: virus

Algorithm for detecting Zika virus (ZIKV) 1

LIAISON XL HCV Ab Accurate diagnosis of the early stage of HCV infection

INTERPRETATION INFORMATION SHEET

Guidance Document Infectious Substances

Animal Health Diagnostic Center. Lyme Disease Multiplex Testing for Dogs. Background on Lyme disease and Lyme diagnostics in dogs

APPENDIX A GUIDANCE DOCUMENT

Medical Laboratory Technology Program. Student Learning Outcomes & Course Descriptions with Learning Objectives

Toxoplasma gondii IgM ELISA Kit Protocol

Zika Virus. Fred A. Lopez, MD, MACP Richard Vial Professor Department of Medicine Section of Infectious Diseases

How Does a Doctor Test for AIDS?

JIANGSU CARTMAY INDUSTRIAL CO.,LTD mail:

Course Descriptions. I. Professional Courses: MSEG 7216: Introduction to Infectious Diseases (Medical Students)

ELISA BIO 110 Lab 1. Immunity and Disease

Effective Treatment of Lyme Borreliosis with Pentacyclic Alkaloid Uncaria tomentosa (TOA-free Cat s Claw)

Identifying Celiac Disease and Gluten Sensitivity with Minimally Invasive Testing

Molecular Diagnosis of Hepatitis B and Hepatitis D infections

Cold Agglutination Titer detecting Cold Reacting Antibodies

Testing for Tick Borne Diseases: How and When?

Guidelines for Collection and Transport of Specimen for Laboratory Diagnosis of Pathogenic Leptospira spp.

IgM ELISA. For the quantitative determination of IgM in human serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.

Borrelia burgdorferi IgG, IgM Fully automated chemiluminescence assays for quantitative determination of Borrelia antibodies in serum and CSF

Hepatitis and Retrovirus. LIAISON XL Accurate detection of HIV infection. HIV Ab/Ag FOR OUTSIDE THE US AND CANADA ONLY

Stachybotrys chartarum a mold that may be found in water-damaged homes

Diagnostic Testing and Strategies for BVDV

LIAISON XL HBsAg Quant

Diagnosing arbovirus infections (and Bill s holiday snaps) David W Smith Division of Microbiology and Infectious Diseases PathCentre

Streptococcus pneumoniae IgG AB (13 Serotypes), MAID... 7

Mouse IgM ELISA. Cat. No. KT-407 K-ASSAY. For the quantitative determination of IgM in mouse biological samples. For Research Use Only. 1 Rev.

Parvovirus B19 Infection in Pregnancy

General Information and Guidelines. Submission of blood tubes

Development and Validation of In Vitro Diagnostic Tests. YC Lee, Ph.D. CEO

Measles (Rubeola) IgM ELISA Catalog No. CB (96 Tests)

Rat Creatine Kinase MB isoenzyme,ck-mb ELISA Kit

Urine Specimen Dilution: Assessment and Policy Recommendations

Human Peripheral Blood Mononuclear Cell (PBMC) Manual

Course Curriculum for Master Degree in Medical Laboratory Sciences/Clinical Microbiology, Immunology and Serology

HBV DNA < monitoring interferon Rx

Viral Hepatitis APHL survey report

NovaLisa (ZVM0790) Performance Characteristics

Viral load testing. medical monitoring: viral load testing: 1

Competency 1 Describe the role of epidemiology in public health

Examination Content Blueprint

TRIIODOTHYRONINE (T3) ELISA Kit Protocol

7- Master s Degree in Public Health and Public Health Sciences (Majoring Microbiology)

Overview of the Cattle Immune System 1

Biopharmaceutical Process Evaluated for Viral Clearance

Policy for the Disposal of Biological Waste

AIR FORCE REPORTABLE EVENTS GUIDELINES & CASE DEFINITIONS

Mouse Insulin ELISA. For the quantitative determination of insulin in mouse serum and plasma

The sensitive marker for glomerular filtration rate (GFR) Estimation of GFR from Serum Cystatin C:

PROPOSED DOCUMENT. Global Harmonization Task Force. Title: Principles of In Vitro Diagnostic (IVD) Medical Devices Classification

HEPATITIS WEB STUDY Acute Hepatitis C Virus Infection: Epidemiology, Clinical Features, and Diagnosis

IgM ANTIBODY CAPTURE ENZYME-LINKED IMMUNOSORBENT ASSAY PROTOCOL

SOP: Prepare Cold Chain (2-8 C) shipment of clinical samples in tropical settings.

(EMEA/CHMP/BWP/298390/2005)

TEST METHOD VERIFICATION AND VALIDATION

High Throughput Assays for Mouse Metabolic Markers: Insulin, Leptin and Adiponectin

Allergy Testing Test Request and Result Interpretation. Learning Objectives

Comparative Pathology Laboratory Services List. Test Name Description of Services Specimen Requirement Notes

SCANTIBODIES Laboratory, Inc. Contract Monoclonal Antibody Production

VS Guidance Date 04/26/13

Clinical Laboratory Parameters For Crl:WI(Han)Rats

FACULTY OF MEDICAL SCIENCE

Manufacturing process of biologics

510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY

QUALITY MANAGEMENT IN VETERINARY TESTING LABORATORIES

Fact Sheet for Health Care Providers: Interpreting Results from the Aptima Zika Virus Assay. June 17, 2016

Laboratory Testing for Middle East Respiratory Syndrome Coronavirus

Edith Cowan University Faculty of Health, Engineering and Science Work Health and Safety Committee

in hiv diagnostics the role of phls

CCAC Animal Data Report

Shipping of Infectious Substances and Patient Specimens

Drug development for children: how adequate is the current European ethical guidance?

Course Curriculum for Master Degree in Medical Laboratory Sciences/Clinical Biochemistry

UTILIZATION of PLASMA ACTIVATED WATER in Biotechnology, Pharmacology and Medicine. JSC TECHNOSYSTEM-ECO Moscow, Russia April, 2009

MALARIA DIAGNOSIS: A GUIDE FOR SELECTING RAPID DIAGNOSTIC TEST (RDT) KITS - 1 st edition

SMF Awareness Seminar 2014

LYME DISEASE. 2.5M specimen tests per year. 97% accuracy with Rockland tools

Basic Overview of Preclinical Toxicology Animal Models

ELITE Custom Antibody Services

OpenMedicine Foundation (OMF)

THE UNIVERSITY OF MAINE BIOMEDICAL WASTE MANAGEMENT PLAN

Human CD4+T Cell Care Manual

THE PREPARATION OF SINGLE DONOR CRYOPRECIPITATE

University of Colorado Campus Box 470 Boulder, CO (303) Fax (303)

Evaluation of SNAP Lepto in the Diagnosis of Leptospirosis Infections in dogs: Twenty two Clinical Cases

General presentation

Level Tow. Level Three

Clinical Laboratory Parameters for Crl:CD(SD) Rats. March, Information Prepared by Mary L.A. Giknis, Ph.D. Charles B. Clifford, D.V.M., Ph.D.

MOLECULAR BIOLOGY 4P03 / BIOLOGY 6P03 - Medical Microbiology

Journal of Chemical and Pharmaceutical Research

Inc. Wuhan. Quantity Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4 Standard (liquid) 2

Please note: Contact Coppe Laboratories at if archival plasma samples need to be tested.

Transcription:

IDEXX BioResearch l Laboratory Animal Diagnostics Dried Blood Spot Specimens for Serological Testing of Rodents Mathew H. Myles, Earl K. Steffen, Cynthia L. Besch-Williford, Beth A. Bauer, Robert S. Livingston, Marcus J. Crim and Lela K. Riley Abstract The utility of dried blood spot () sampling technology for rodent colony health monitoring was investigated using a two-tiered approach. In the first approach, groups of ICR mice and SD rats were experimentally infected. Mice were inoculated with epizootic diarrhea of infant mice (EDIM) virus, mouse hepatitis virus (MHV), murine norovirus (MNV), mouse parvovirus (MPV) or Theiler s murine encephalomyelitis virus (TMEV). Rats were inoculated with Kilham s rat virus (KRV) or rat theilovirus (RTV). Paired and serum specimens were collected at 2, 4, 6 and 12 weeks postinoculation. In the second approach, designed to evaluate real-world conditions, over 1, mouse and rat paired and serum specimens were collected from collaborating North American institutions. and serum specimens were evaluated by multiplex fluorescent immunoassay () against a comprehensive panel of infectious disease assays, and data was compared for magnitude of signal, signal-to-noise ratio, correlation and stability. Results from these studies demonstrated that the magnitude of the mean positive signal from the specimens was equal to or higher than the corresponding serum specimens. Moreover, the assay signal-to-noise ratio from the specimens was equal to or higher than the corresponding serum specimens. Evaluation of a large cohort of paired clinical and serum specimens showed 1% diagnostic correlation and improved specificity. Finally, stability studies showed no degradation of signal when specimens were protected from humidity and stored at room temperature or 4 C for up to 14 days or when stored at 2 C for up to 3 months, compared to controls. A moderate decrease in signal was encountered when specimens were stored at 37 C in 95% humidity for 24 hours; however, all specimens remained diagnostically positive. Introduction Over the past five decades, great strides have been made in the identification and eradication of infectious agents from laboratory rodents. As a result, most contemporary biomedical research rodent colonies are relatively free of the pathogenic viruses, parasites, bacteria and fungi that cause clinical disease. However, some microbes, especially those agents that cause subclinical disease, remain in an enzootic state in many research colonies. These agents, despite their insidious nature, have an impact on physiologic parameters of the host and thus on the results of animal experiments, independent of their pathogenic potential. Timely and accurate diagnosis of infectious disease in rodent colonies is critical to the success of biomedical research. To this end, institutional veterinarians closely monitor the health of research animals through periodic systematic examination of specimen groups of research and sentinel animals against a predetermined list of infectious agents. Serological testing for the detection of antibodies to infectious agents is an important component of a comprehensive rodent health monitoring program. Serological evidence of naturally acquired infection is typically detectable within 2 weeks postinfection and a measurable antibody titer persists for many months after initial infection. Accordingly, serological health monitoring provides a means for detection of both recent and past infectious disease exposure. The ability to detect past infections by serology dramatically increases the window of detection for infectious agents that can be cleared by the host, such as viruses, which can therefore easily go undetected by PCR evaluation alone. Serological testing is a critical component of a comprehensive rodent health monitoring program and has benefited significantly from recent technological advancements in serological testing platforms. One such advancement is the microsphere-based multiplex system that requires as little as 1 μl of undiluted serum for evaluation against a comprehensive panel of infectious agents. Despite the improvements in testing technology, there has been little change in blood specimen collection techniques. Conventional blood specimen collection from rodents is accomplished by cardiocentesis or superficial venipuncture and requires a relatively large volume of blood because of the logistical constraints associated with downstream processing, preparation and transport of serum; however, most of the serum specimen goes unused by the testing laboratory. Dried blood spot sampling technology offers a mechanism to harmonize blood specimen collection and specimen volume testing requirements. Dried blood spot () sampling technology involves the collection of a single drop (~25 μl) of whole blood onto filter paper. The specimen, once dry, is very stable and amenable to a variety of quantitative and qualitative analyses. 1 sampling technology was first introduced in 1963 as a means to measure phenylalanine levels for the diagnosis of phenylketonuria in newborns. 2 Since that time, sampling technology has been used as a sampling technique for newborn metabolic disease screening, molecular testing for infectious disease diagnosis and therapeutic drug monitoring. 3,4 Furthermore, pharmaceutical

2 companies have recently adopted sampling methods for preclinical pharmacokinetic and toxicokinetic testing in rodents in order to improve animal welfare, drastically reduce animal numbers, improve study precision and reduce costs. Study Design The utility of sampling technology for rodent colony health monitoring was investigated using a two-tiered approach. To this end, 6 groups of 2 ICR mice each were inoculated by gavage or dirty bedding transfer with epizootic diarrhea of infant mice (EDIM) virus, mouse hepatitis virus (MHV), murine norovirus (MNV), mouse parvovirus (MPV), Theiler s murine encephalomyelitis virus (TMEV) or sham. In addition, 3 groups of 8 SD rats each were inoculated by gavage or dirty bedding transfer with Kilham s rat virus (KRV), rat theilovirus (RTV) or sham. Serial paired and serum specimens were collected at 2, 4, 6 and 12 weeks postinoculation. Further, over 1, mouse and rat paired and serum specimens were collected from collaborating North American institutions. Paired and serum specimens were evaluated by multiplex fluorescent immunoassay () against a comprehensive panel of infectious disease assays, and data was compared for magnitude of signal, signal-to-noise ratio, diagnostic correlation and stability. Results Experimental Infection of Mice (Fig. 1) The results from this study demonstrated that seroconversion to EDIM, MHV, MNV, MPV and TMEV occurred by week 2 postinfection, and agent-specific antibody titers remained elevated throughout the duration of the study. Mice developed antibody exclusively to the specific infectious agent with which they were inoculated, and there was no antibody cross-reactivity to any of the other 27 assays. The magnitude of the mean positive signal from the specimens was equal to or higher than the corresponding serum specimens. Moreover, the assay signal-to-noise ratio from the specimens was equal to or higher than the corresponding serum specimens. Experimental Infection of Rats (Fig. 2) The results from this study demonstrated that seroconversion to KRV and RTV occurred by week 2 postinfection, and agent-specific antibody titers remained elevated throughout the duration of the study. Rats developed antibody exclusively to the specific infectious agent with which they were inoculated, and there was no antibody cross-reactivity to any of the other 21 assays in the panel of tests. The magnitude of the mean positive signal from the specimens was equal to or higher than the corresponding serum specimens. Moreover, the assay signal-to-noise ratio from the specimens was equal to or higher than the corresponding serum specimens. Collaborative Studies (Fig. 3) To evaluate the clinical utility of sampling technology, over 1, mouse and rat paired and serum specimens were collected from collaborating North American institutions. Paired specimens were evaluated by against a comprehensive panel of infectious disease assays, and data was compared for magnitude of signal and diagnostic correlation. Antibodies to MNV, MHV and MPV were detected by in a subset of the paired serum and specimens, and positive MHV and MPV results acquired by were confirmed by immunofluorescence assay (IFA) of the specimen. The magnitude of the signal from all positive specimens was equal to or higher than the corresponding serum specimen. Moreover, the paired clinical and serum specimens showed 1% diagnostic correlation. Stability Studies (Fig. 4) The stability of specimens was evaluated using whole blood collected from known antibody-positive mice. To simulate short- and long-term storage conditions, whole blood (25 μl) was deposited on multiple strips, and specimens were stored in sealed plastic bags with desiccant at 2 C, 4 C or room temperature (~21 C). Further, to simulate the environmental extremes that specimens may encounter during shipment, specimens were stored at 37 C in % or 95% humidity for 24 hours. Specimens were removed from storage at various time points and evaluated by against a comprehensive panel of infectious disease assays, and data was compared for magnitude of signal. The stability studies demonstrated no degradation of signal when specimens were protected from humidity and stored at room temperature or 4 C for up to 14 days or when stored at 2 C for up to 3 months, compared to controls. specimens stored at 37 C and % humidity for 24 hours showed a modest decrease in mean signal compared to specimens stored at room temperature (37 C, % humidity: 15,42.11 ± 5,55.55; room temperature: 2,16.83 ± 3,989.82). specimens stored for 24 hours at 37 C and 95% humidity showed a more marked decrease in mean signal compared to control specimens (9,574.78 ± 3,678.96); however, all specimens remained diagnostically positive. Conclusion Dried blood spot sampling technology requires only a single drop (~25 μl) of whole blood, making antemortem sampling easily achievable and potentially reducing the number of mice used for sentinel monitoring. Unlike traditional serum, specimens require no further processing before shipment to the testing laboratory, saving the investigator time and costs associated with specimen processing. specimens are stable at room temperature for up to 14 days when protected from humidity; thus, allowing for shipment in a standard overnight envelope and avoiding additional shipping costs associated with refrigerated shipping boxes.

3 2 MNV 3, MPV 2, 2 2, 3, MHV 3, TMEV 2 2 2, 2, 2, EDIM Positive Serum Positive Negative Serum Negative Figure 1. Experimental Infection of Mice Groups of 2 ICR mice were inoculated, by gavage or dirty bedding transfer, with EDIM, MHV, MNV, MPV, TMEV or sham. Serial paired and serum specimens were collected at 2, 4, 6 and 12 weeks postinoculation. Mice developed antibody exclusively to the specific infectious agent with which they were inoculated, and there was no antibody cross-reactivity to any of the other 27 assays. The magnitude of the mean positive signal from the specimens was equal to or higher than the corresponding serum specimens. Moreover, the assay signal-tonoise ratio from the specimens was equal to or higher than the corresponding serum specimens.

4 2, Positive Serum Positive Negative Serum Negative KRV 2 2, Positive Serum Positive Negative Serum Negative RTV Week Postinfection Week Postinfection Figure 2. Experimental Infection of Rats Groups of 8 SD rats were inoculated, by gavage or dirty bedding transfer, with KRV, RTV or sham. Serial paired and serum specimens were collected at 2, 4, 6 and 12 weeks postinoculation. Paired specimens were evaluated by against a comprehensive panel of infectious disease assays, and data was compared for magnitude of signal and signal-to-noise ratio. The results from this study demonstrated that seroconversion to KRV and RTV occurred by week 2 postinfection, and agent-specific antibody titers remained elevated throughout the duration of the study. Rats developed antibody exclusively to the specific infectious agent with which they were inoculated, and there was no antibody crossreactivity to any of the other 21 assays in the panel of tests. The magnitude of the mean positive signal from the specimens was equal to or higher than the corresponding serum specimens. Moreover, the assay signal-to-noise ratio from the specimens was equal to or higher than the corresponding serum specimens. 3, MNV Serum 2 MHV Serum 2 2, 2, Negative Positive Negative Positive Negative Positive Negative Positive Figure 3. Collaborative Studies To evaluate the clinical utility of sampling technology, over 1, mouse and rat paired and serum specimens were collected from collaborating North American institutions. Paired specimens were evaluated by against a comprehensive panel of infectious disease assays and data were compared for magnitude of signal and diagnostic correlation. Antibodies to MNV, MHV and MPV were detected by in a subset of the paired serum and specimens, and positive MHV and MPV were results acquired by were confirmed by immunofluorescence assay (IFA) of the specimen. Paired clinical and serum specimens showed 1% diagnostic correlation.

5 2 A 2 C 2 B 4 C 2, 2, 3 6 9 1 3 7 14 Days in Storage Days in Storage Room Temperature 37 C 2 C 2 D 2, 2, 1 3 7 14 Days in Storage Serum RT 37 C/%H 37 C/95%H Figure 4. Stability Studies The stability of specimens was evaluated using whole blood collected from known antibody positive mice. To simulate short- and long-term storage conditions, whole blood (25 μl) was deposited on multiple strips, and specimens were stored in sealed plastic bags with desiccant at (A) 2 C, (B) 4 C or (C) room temperature (~21 C). Further, to simulate the environmental extremes that specimens may encounter during shipment, specimens were stored at (D) 37 C in % or 95% humidity for 24 hours. Specimens were removed from storage at various time points and evaluated by against a comprehensive panel of infectious disease assays, and data was compared for magnitude of signal. The stability studies demonstrated no degradation of signal when specimens were protected from humidity and stored at room temperature or 4 C for up to 14 days or when stored at 2 C for up to 3 months, compared to controls. specimens stored at 37 C and % humidity for 24 hours showed a modest decrease in mean signal compared to specimens stored at room temperature (37 C, % humidity: 15,42.11 ± 5,55.55; room temperature: 2,16.83 ± 3,989.82). specimens stored for 24 hours at 37 C and 95% humidity showed a more marked decrease in mean signal compared to control specimens (9,574.78 ± 3,678.96); however, all specimens remained diagnostically positive. References 1. Adam BW, Hall EM, Sternberg M, et al. The stability of markers in dried-blood spots for recommended newborn screening disorders in the United States. Clin Biochem. 211;44(17 18):1445 145. 2. Guthrie R, Susi A. A simple phenylalanine method for detecting phenylketonuria in large populations of newborn infants. Pediatrics. 1963;32(3):338 343. 3. Dowd JB, Aiello AE, Chyu L, Huang YY, McDade TW. Cytomegalovirus antibodies in dried blood spots: a minimally invasive method for assessing stress, immune function, and aging. Immun Ageing. 211;8:3. www.immunityageing.com /content/8/1/3. Published January 13, 211. Accessed December 6, 213. 4. Corran PH, Cook J, Lynch C, et al. Dried blood spots as a source of anti-malarial antibodies for epidemiological studies. Malar J. 28;7:195. www.malariajournal.com/content/7/1/195. Published September 3, 28. Accessed December 6, 213.

IDEXX BioResearch Europe +49 () 7141 64 83 585 idexxbioresearch.com.europe idexxbioresearch-europe@idexx.com 213 IDEXX Laboratories, Inc. All rights reserved. 9-8545- All /TM marks are owned by IDEXX Laboratories, Inc. or its affiliates in the United States and/or other countries. The IDEXX Privacy Policy is available at idexx.com.