BEST PRACTICES for FLEXIBLE PIPE INTEGRITY EVOLVE. PAM BOSCHEE l OIL & GAS FACILITIES EDITOR 2 3 4 5

Similar documents
Subsea Technology. Alain Marion, Senior VP Assets & Subsea Technology. Investor Day in Brazil, October 4, 2011

How to live with Flexible Pipe, happily ever after?

November, 2008, Aberdeen. Riser Integrity. HSE Flexible Pipe Integrity Forum

Comparison of Steel Tubes and Thermoplastic Hoses in Umbilical Service

In-line inspection (intelligent pigging) of offshore pipeline. Birger Etterdal

SPECIALTY FIBER OPTIC CABLE. Downhole Sensing Subsea

THERMOPLASTIC LINERS FOR REHABILITATION OF OIL FLOWLINE AND WATER INJECTION LINES, INTEGRITY AND SERVICE LIFE

NON-DESTRUCTIVE TESTING OF PIPELINES. L. Annila. Abstract

Kodiak Deepwater Project Challenges and Solutions

PIPELINE INSPECTION UTILIZING ULTRASOUND TECHNOLOGY: ON THE ISSUE OF RESOLUTION By, M. Beller, NDT Systems & Services AG, Stutensee, Germany

The Suitability of CRA Lined Pipes for Flowlines Susceptible to Lateral Buckling SUT Global Pipeline Buckling Symposium, February 2011

Revolutionary Inspection Technology by FORCE Technology

Guidelines the DNV way

RISK BASED INSPECTION (RBI)

MODELING THE EFFECT OF TEMPERATURE AND FREQUENCY ON BITUMEN-COATED HELICAL CABLE ELEMENTS

Total Subsea Solutions

High Density Polyethylene Liners for Rehabilitation of Corroded Pipelines

CATHODIC PROTECTION SYSTEM DESIGN

An Introduction to Oil and Gas Well Servicing

OFFSHORE OIL & GAS SECTOR STRATEGY 2014 TO 2017

Subsea umbilicals. At the forefront of umbilical technology

AOG 2015 Acoustic System to Monitor Wellhead Fatigue in Real-time. March 12 th

Managing The Integrity Threat Of Subsea Pipework Fatigue Failure. John Hill Senior Consultant Xodus Group

Facilities Flexibras Tubos Flexíveis Ltda

13. FPSO Operational Problems Don Smith, OGP

Experimentation and Computational Fluid Dynamics Modelling of Roughness Effects in Flexible Pipelines

CH 6: Fatigue Failure Resulting from Variable Loading

NCCER Progress Blvd., Alachua, FL Tel: (888) Task Number Item Date(s) Recorded By

Subsea wellhead systems. Advanced solutions for extreme conditions

Fiber Optic Cable Pipeline Leak Detection Systems for Arctic & Cold Region Applications

Electric heat tracing

CNG & Hydrogen Tank Safety, R&D, and Testing

Fibre Mooring JIPs by DNV

Delivering Riser Engineering and Software Solutions

Tubing Data. Contents. Tubing Selection. Tubing Handling. Tubing Material. Tubing Outside Diameter Hardness. Tubing Wall Thickness

New Generation of Deepwater BOP Stacks. Dominique Allegre CAMERON Paris, October 23rd 2013

Numerical Analysis of Independent Wire Strand Core (IWSC) Wire Rope

Offshore Structures. Offshore Drilling Equipment

Subsea Drilling Systems

Honeywell Corrosion Solutions

Technip s Drilling & Refining Applications Division. Coflexip Flexible Steel Pipes for Drilling and Service Applications.

Prestressed Concrete Pipe Fitness for Service and Repair

Investigating the Impact of Boiler Aging In Replacement Decisions

Corrosion Reliability Inspection Scheduling CRIS-Joint Industry Project

Structural Failures Cost Lives and Time

Send your directly to

Salzgitter Industrial Supply Chain Concept for Offshore Wind Jackets

Ultrasonic Guided Waves Evaluation of Trials for Pipeline Inspection

Measuring the Condition of Prestressed Concrete Cylinder Pipe

The Use of Coatings for Corrosion Control on Offshore Oil Structures. J. Peter Ault, P.E. Consultant Ocean City, NJ

SECTION HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS FOR WATER DISTRIBUTION AND TRANSMISSION

Structural concepts for minimum facility platforms for Marginal field development in western offshore, India

HV Submarine Cable Systems Design, Testing and Installation

Crevice Corrosion on Stainless Steel Propeller Shafts

SECTION HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS

INTERNATIONAL STANDARD

DEVELOPMENT OF THE PATHFINDER FOAM CALIPER PIG. By: Peter Ward, Pipeline Innovations Ltd, UK

Water Transmission & Sewer Force Main Renewal 16 through 60

Subsea Asset Monitoring using Distributed Fiber Optic Sensing

WSSC Ad-Hoc Committee on Large Diameter Water Mains. August 2, 2013

Stainless Steel Pipe Fabrication

Introduction to Subsea Production System

Specification for Rotary Drill Stem Elements

different levels, also called repeated, alternating, or fluctuating stresses.

WELLHEAD FLOWLINE PRESSURE PROTECTION USING HIGH INTEGRITY PROTECTIVE SYSTEMS (HIPS)

Stilling Well Recommendations

CORNING CABLE SYSTEMS GENERIC SPECIFICATION FOR TIGHT BUFFER OPTICAL FIBER CABLES FOR INTER- AND INTRABUILDING APPLICATIONS.

North American Stainless

Meeting the Challenge of Pipeline Emergency Repair

Guidelines for the Survey of Offshore Mooring Chain Cable in Use

Naue GmbH&Co.KG. Quality Control and. Quality Assurance. Manual. For Geomembranes

Hyper duplex stainless steel for deep subsea applications

SilverPipe. Pipeline Integrity Management Software. Lene B. Synnestvedt December 2011

REPORT OF A COATING FAILURE ON A 16-INCH OIL PIPELINE UNDER WET CO2 SERVICE

Deepwater Horizon Accident Investigation Report

3. Test Methods for Evaluation of ESCR of Plastics

Premium Tubular Solutions Super Duplex Welded Tubes for Umbilical Applications

Ultrasonic Reference Blocks

CSA Group Safety Standards for Oil and Gas Pipeline Systems: A Life-Cycle Approach

Flexible Pipe Stress and Fatigue Analysis

Theory of Heating by Induction

Real-time Subsea Pipeline Leak Monitoring using Fiber Optic Sensing Technology

Darchem Thermal Protection

TABLE OF CONTENT

CONDITION ASSESSMENT AND RISK MANAGEMENT OF WATER MAINS SAVES TENS OF MILLIONS OF EUROS?

BUMAX. REYHER your partner for the BUMAX range

AC : MATERIAL SELECTION FOR A PRESSURE VESSEL

Force Main Condition Assessment: New Technologies & Case Studies

HSE information sheet. Fire and explosion hazards in offshore gas turbines. Offshore Information Sheet No. 10/2008

American Petroleum Institute Purchasing Guidelines Purchase API Spec 7K online at

Reducing CO2 emissions for Offshore oil and gas Operations under ETS. Margaret Christie, Environmental Advisor, UK Business Unit, Premier Oil UK Ltd

BKP Berolina Polyester GmbH & Co. KG. Berolina-Liner System Lightspeed in gravity pipe rehabilitation!

Wet Stator Units for Oil and Gas Upgrade and support services

Application of Welding Standards in Hong Kong. S. K. Babu Laboratory Manager - Foundation Techniques Ltd

SUBSEA CONNECTORS FOR MARINE RENEWABLE ENERGY APPLICATIONS

CURRENT EXPERIENCE IN TYPICAL PROBLEMS AND FAILURES WITH BOILER PIPING COMPONENTS AND SUPPORTS

Ultrasonic Gas Leak Detection

Rigorous Qualification and Development Program

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

More inside :: Tackle even the toughest water treatment piping challenges with

Transcription:

BEST PRACTICES for FLEXIBLE PIPE INTEGRITY EVOLVE 1 PAM BOSCHEE l OIL & GAS FACILITIES EDITOR 2 3 4 5

perators... BASED ON THE PROJECT DATABASE, KEY FLEXIBLE PIPE STATISTICS ARE AS FOLLOWS: are increasingly recognizing the need for a systematic assessment and management of flexible pipe integrity, but the identification of critical criteria and the means to best achieve valid and efficient inspection and monitoring (I&M) continues to evolve. Emerging technologies in I&M and operators expanding implementation of riskbased management are leading the way toward achieving a comprehensive integrity management approach for flexible pipeline and riser systems worldwide. Flexible pipes are being installed and operated in more marginal and challenging offshore conditions, adding to the complexity of acquiring complete and valid data for the determination of their integrity. Especially important is the accurate assessment of the remaining life of a flexible riser so operators can avoid costly premature change outs. To further develop the definition of best practices in flexible pipe integrity assurance, the SureFlex Joint Industry Project (JIP) presented key findings from its extensive 20-month-long survey work, including flexible pipe use worldwide, statistics on design limits, damage, and failure incidences. Conducted under the auspices of the Oil and Gas UK, a trade association for the United Kingdom upstream oil and gas industry, the State of the Art Report on Flexible Pipe Integrity and Guidance Note on Monitoring Methods and Integrity Assurance for Unbonded Flexible Pipes (2010) revisited the state of flexible pipe since the first survey in 2001 to 2002. The scope of work was international in its content and had the support of international companies outside of the UK. O Brien et al. (2011) reported the outcomes of the JIP s data gathering from flexible pipe operators worldwide, manufacturers, and specialists in the field. From the time of the first survey, MCS Kenny compiled an in-house database of flexible pipe use, damage, and failure incidents. A comprehensive literature review was also performed. The resultant database covered 1,900 flexible risers and 1,400 static flexible flowlines; 130 production facilities worldwide; and 315 individual damage and failure incidents from around the world. 58 % 76 % 90% <50,000 psi-in. 70% 70 % of installed flexible pipes are risers. of all flexible pipes have design pressures of less than 5,000 psi (345 bar). of all flexible pipes are less than 10-in. in diameter. Pressure by internal diameter (p ID) of the majority of flexible pipes. of flexible pipe has been designed for a temperature of less than 176 F (80 C). of operating flexible risers are in a water depth of less than 3,281 ft (1000 m). 16 Oil and Gas Facilities February 2012

2,000 1,800 1,600 1,400 Water Depth, m 1,200 1,000 800 600 400 200 0 0 2 4 6 8 10 12 14 16 18 Internal Diameter, in. Fig. 1 Water depth vs. internal diameter for flexible pipe in operation worldwide. Pressure, psi 20,000 18,000 16,000 14,000 12,000 10,000 8,000 6,000 4,000 2,000 P*ID=30,000 P*ID=50,000 P*ID=70,000 P*ID=80,000 0 0 2 4 6 8 10 12 14 16 18 20 Internal Diameter, in. Fig. 2 Design pressure vs. internal diameter for operating flexible pipe. The deepest water depth in which a flexible riser is installed is about 6,234 ft (1900 m) with a flexible pipe internal diameter (ID) of about 7.5 in. as shown in Fig. 1. Although flexible risers with ID of more than 16 in. have been installed offshore, these are in water depths not exceeding 1,312 ft (400 m). Fig. 2 shows the largest p ID value in operation, 80,000 psi-in. for a 12-in. flexible pipe. The majority of flexible pipe in use has a p ID value of less than 50,000 psi-in. Flexible Pipe Failure/Damage Mechanisms The most recent survey found that external sheath damage remains the most common failure, showing an increase since 2001 (Fig. 3). The external sheath is an external polymer barrier applied to the flexible pipe to resist mechanical damage and seawater corrosion of the tensile and pressure armor wires of the flexible pipe. Its presence creates an annulus between the internal barrier sheath and the external sheath of the flexible pipe. Patrick O Brien, group director of strategic business and marketing at Wood Group Kenny, said, We might attribute this increase to people not being fully aware of the real extent of external sheath damage in 2001, as they were likely not testing for it. However, when the issue was raised in the first report, more operators by good practice would regularly test the annuli of their flexible risers, and we began to see a higher incidence of the damage. In 2001, external sheath damage was identified when measurement of annulus pressure through a vent valve at the riser vessel connection revealed that the annulus did not hold its pressure, indicating that the sheath may have been breached, most likely by a small crack or a pinhole in the external sheath farther down the riser. In these cases, gross structural damage of the armor wires within the annulus was not found to have occurred. February 2012 Oil and Gas Facilities 17

40% 35% % of Failure/Damage Incidents 30% 25% 20% 15% 10% 2002 UKCS and Norway only 2010 Worldwide Others: Smooth bore collapses Pigging Damage Upheaval Buckling Excess Torsion Excess Tension Sheath cracking Armour wire failure 5% 0% External Sheath Damage/Flood Aged Internal Sheath Pullout Internal Sheath Ancillary Device Failure Overbend End Fitting Leak Birdcaging Ovalisation Vent System Anomalies Wax Blockage Corrosion Carcass Failure Other Fig. 3 Flexible pipe failure/damage mechanisms. Fig. 4 General armor wire corrosion. One finding related to external sheath damage has only emerged since the original study, O Brien said. There is a subset of external sheath damage where general and extensive armor wire corrosion (Fig. 4) occurs due to gross external sheath damage along a region of the riser within the splash zone and where the riser may also be shielded by vessel structures. The shielding effect of the vessel structures can prevent proper operation of the riser s corrosion protection system, while the splash zone causes intermittent wetting effects that provide a supply of oxygen, which encourages a highly corrosive environment. Hidden locations at the riser top section close to end fittings, for example at J-tubes, are susceptible to this type of external sheath breach and subsequent armor corrosion. Operators were generally not aware of its incidence or prevalence in the first study, but there have been significant instances of it in the last number of years, he said. Operators have increased their focus on how they connect and install their flexible risers to the floating production facility so as to avoid this failure mode in the future, he added. Two failure/damage mechanisms showing significant decreases in incidence since 2001 were related to the internal sheath aged internal sheaths and polyvinylidene fluoride (PVDF) internal sheath pullout failures (Fig. 3). The oil and gas industry has studied the causes of aged internal sheaths, largely affected by high water content and elevated bore temperatures on polyamide 11 (PA11), a high-performance polymer material that allows for higher operating pressures than does high-density polyethylene (HDPE). As a result, operators gained a better understanding of the properties of PA11 and how to monitor, control, and predict its life cycle. PVDF internal sheath pullout failures have dropped with the introduction of new end fitting designs developed by the flexible pipe manufacturers. Early Planning for Integrity Management O Brien noted that the survey results point to the need for operators to consider their flexible pipe integrity management strategies at the earliest stages possible. From the minute you think about designing a flexible riser or flexible pipeline, even at concept, front-end engineering design, and into operations, the guidance note recommendations propose what should be done at those stages to consider integrity, he said. One of the challenges in developing an early I&M strategy is the lack of coordinated efforts between project teams charged with the design and the operations personnel. How do you get a change in behavior at the project stage? 18 Oil and Gas Facilities February 2012

Fig. 5 Flexible pipe layers of dissected riser. Source: OTC 22398. End Fitting Sample 1 I-Tube 5 PA-11 External Sheath Carbon Steel Tensile Armors Carbon Steel Pressure Armor PA-11 Pressure Sheath 4 Project teams are focused on design, aiming for controlled costs. Then suddenly, it is handed over to operations, O Brien said. Despite recognized issues related to flexible pipe fatigue and armor wire corrosion, and the availability of monitoring techniques such as fiber optics embedded in armor wires to allow measurement of real-life stress, operators will sometimes decide at the design stage to forego their inclusion to cut costs. O Brien said, They re not thinking about the benefit that might bring to operations. Some operators are now making sure that they are bringing their operations people into the project team so no decision is made that might be favorable for capital expenditures, but would be a poor one for subsequent operating expenditures. Guidance for I&M High-strength armor wire used in flexible pipe systems for offshore applications is subject to harsh service conditions, including service stress loadings and corrosive environments. In efforts to accurately measure the condition and remaining life of the armor wires, one of the major issues is the determination of the real conditions within the flexible pipe annulus. O Brien said debate continues about whether or not armor wire in an annulus is fully exposed to presumed environmental conditions in the pipe bore, or if the actual environment is much more benign than what is being predicted. Today, we assume the worst case scenario, such as if there is hydrogen sulfide and carbon dioxide in the bore of the pipe, it will permeate out into the annulus, 3 Flexible Pipe 2 Sample 2 1 Bend Stiffener Interlocked Stainless Steel Carcass Subsea Fig. 6 Locations of flexible pipe dissection. Source: OTC 22398. exposing armor wires to the same conditions. However, there is significant evidence for that not being the case. Operators have made decisions to change out risers because their integrity prediction methods indicated that the riser was approaching its predicted fatigue life. Regarding the selection of appropriate I&M methods, O Brien said, Part of the problem is that there is no single magic piece of technology out there that is able to properly inspect flexible pipe. It is a bit like detective work, selecting a range of alternative inspection and monitoring techniques, which when utilized together help you to establish the current integrity of your flexible pipe. In a recent case, following the decommissioning of a 10-year-old flexible riser with a flooded annulus, the dissection, inspection, and laboratory analysis of components showed that the condition of the armor wire remained comparable to the as-manufactured conditions (Charlesworth et al. 2011). Fatigue Performance of a Flooded Annulus Charlesworth et al. described the dissection process and condition of a flexible, high-pressure gas riser following its decommissioning from the West of Shetland (WoS) region. BP managed riser integrity using a risk-based approach on its WoS flexible risers installed in the late 1990s. As part of this process, fatigue of armor wires in those risers with flooded annuli was identified as a failure mode. As occurs in many flexible risers worldwide, external sheath breaches occurred during installation of the WoS risers, causing annulus flooding. BP sealed the locations of the risers breaches, displaced the seawater in the annuli with a corrosion inhibitor, and implemented a program of regular fatigue life reassessments for the affected risers. In 2008, one of BP s WoS gas risers with a flooded annulus was identified by calculations used in the integrity management process to be approaching its predicted fatigue life, indicating that replacement was the appropriate course of action. Following decommissioning of the riser, it was dissected at Technip s Le Trait Manufacturing Unit and its various metallic and polymer layers were inspected. Armor wire samples were taken from the fatigue critical region of the riser and tested at Marintek to establish S-N curves in an environment representative of the affected riser s annulus. (An S-N curve shows the results of a fatigue test as a plot of stress [S] against the number of cycles to failure [N]. A log scale is used for N.) The major structural layers of the riser are shown in Fig. 5. Dissection locations are shown in Fig. 6, and findings of the dissection in Table 1. The S-N testing of the armor wire samples from the decommissioned pipe was carried out following the guidelines of a test protocol recently developed as part of a Marintek-run JIP on flexible pipe corrosion fatigue, as was the testing of the as-manufactured armor wire samples. Fatigue testing of the tensile armor wires taken from the February 2012 Oil and Gas Facilities 19

TABLE 1 FLEXIBLE PIPE DISSECTION FINDINGS Layer Sample 1 Sample 2 Carcass Isolated pitting Isolated pitting Pressure sheath Regular creeping into pressure armor Carcass rigidly held Regular creeping into pressure armor Carcass rigidly held Pressure armor Limited corrosion/pitting Limited corrosion/pitting Tensile armor No abnormal gaps or overlap Limited corrosion No abnormal gaps or overlap Limited corrosion External sheath Longitudinal surface scratches Discoloration Longitudinal scratches Marine growth stains and discoloration Local minor damage on internal skin Anti-wear tapes Regular distribution Regular distribution Local overlap under the bend stiffener Creeping under the bend stiffener High-strength tape Good general condition No disorganization Local slight tape stretching Major damage under the bend stiffener Source: OTC 22398. decommissioned pipe showed fatigue lives comparable to the as-manufactured wire. Charlesworth et al. said the findings demonstrated the conservative nature of current fatigue prediction models. As flexible pipe installations increase in more challenging environments, overly conservative fatigue prediction methodologies may limit the applicability of technology, they added. One factor that may contribute to overly conservative criteria used in prediction models is the lack of transparency about armor wire testing methods and results by flexible pipe manufacturers. O Brien said that although manufacturers perform comprehensive testing and qualification of their armor wires, the results are not made publicly available. He said, Without wanting to impact in any way or take from the commercial business of these manufacturers, as an industry, we need to get more transparency in terms of how fatigue calculations are performed, as this would facilitate the ability to radically improve our assessment of the remaining life of flexible riser systems. Emerging and New I&M Technologies The magnetic anisotropy and permeability system (MAPS), an emerging technology listed in Table 2, was developed by MAPS Technology as an inspection tool that can be connected to a flexible pipe to monitor for armor wire damage and breakage. The MAPS technology capitalizes on the magnetic properties of iron, steel, and other ferromagnetic materials and their sensitivity to stress. The internal magnetic structure of these materials is divided into domains, which are strained along the direction of their magnetization, a property known as magnetostriction. When stress occurs, the degree of domain alignment is altered, causing a measurable change in the material s magnetic properties. In experiments with armor wire, the wire s magnetostriction was altered with a change in stress applied to it. The applied stress and measured stress correlated well, enabling operators to monitor the stress in armor wires, during and after a significant wave event. Field trials of MAPS were being conducted on a Petrobras platform at the time of writing of the JIP report to determine the effectiveness of the method in a real environment. Tritech recently launched its riser and anchor chain monitoring system (RAMS), a multibeam sonar technology for floating production, storage, and offloading (FPSO) units. RAMS is deployed beneath the FPSO s turret and extends down below the level of the bend stiffeners. The transceiver 20 Oil and Gas Facilities February 2012

TABLE 2 Inspection AND MONITORING techniques Technique/Method Take-up (Rated 1 to 5) 1 Limited, specific applications 5 Common practice Industry JIP feedback (Rated 1 to 5) 1 Under development, unproven 5 Highly reliable Proof pressure testing 2 3 (short-term assurance only/ad hoc method) Visual inspection 5 4 (anomaly tracking/gross defects) Ultrasonic 2 (some examples to detect annulus flooding) 3 (unproven at detecting wire defects; access to critical region may be problematic) MAPS* 1 (offshore trials ongoing) 2 Polymer coupons 3 (commonly used for high-temperature applications) 4 (limited implementation, but can provide assurance for PA11) Annulus monitoring-various techniques 4 (significant increase in recent years) 3 4 (can detect flooding, though dependent on access) Eddy current 1 2 (new tool under development) Radiographics 2 (historically limited to topsides) 3 (digital method under development) Intelligent pigging 1 1 Torsion monitoring 1 (focused on deepwater applications) 1 (alternative systems under development) Curvature monitoring 1 (focused on fatigue) 2 (no operational feedback) Acoustic emission 1 2 (not field-proven) Sonar monitoring (RAMS) 1 (limited use to date) 4 (has detected bend stiffener loss) FPU excursion/environment monitoring 4 3 (several systems have failed to properly record and log excursion data) Fiber optic monitoring 2 (embedded in tensile armor wires to detect strain cycling) 2 (no operational feedback) * MAPS magnetic anisotropy and permeability system RAMS riser and anchor chain monitoring system (Tritech) For Further Reading emits a horizontal sonar beam through 360 to generate and record sonar images of the spatial positions of the risers and mooring chains. RAMS has the option to provide the FPSO operator with an alarm-based system that detects out-of-specification movement of risers and mooring lines, and allows the measurement and export of trend data for use in material fatigue analysis. The system has been installed since 2009 on the Teekay Petrojarl Foinaven FPSO, operating on BP s deepwater oil field off the West Coast of Shetland. BP reported the system to have been 100% effective. O Brien said that because flexible pipe I&M techniques continue to improve and develop at a reasonably fast pace, the guidance note will be reviewed annually to keep pace with developments and to keep operators up to date. OGF State of the Art Report on Flexible Pipe Integrity and Guidance Note on Monitoring Methods and Integrity Assurance for Unbonded Flexible Pipes (2010) at www.oilandgasuk.co.uk, publications, code OP010 OTC 22398 Operational Experience of the Fatigue Performance of a Flexible Riser with a Flooded Annulus by David Charlesworth, BP, et al. OTC 21844 Developments in Managing Flexible Risers and Pipelines, a Supplier s Perspective by C.S. Dahl, NKT Flexibles I/S, et al. OTC 21524 Outcomes from the SureFlex Joint Industry Project An International Initiative on Flexible Pipe Integrity Assurance by Patrick O Brien, Wood Group Kenny, et al. February 2012 Oil and Gas Facilities 21