18 Conductometric Titration

Similar documents
15. Acid-Base Titration. Discover the concentration of an unknown acid solution using acid-base titration.

Evaluation copy. Titration of a Diprotic Acid: Identifying an Unknown. Computer

DETERMINATION OF PHOSPHORIC ACID CONTENT IN SOFT DRINKS

ph units constitute a scale which allows scientists to determine the acid or base content of a substance or solution. The ph 0

To determine the equivalence points of two titrations from plots of ph versus ml of titrant added.

Acid Base Titrations

To see how this data can be used, follow the titration of hydrofluoric acid against sodium hydroxide below. HF (aq) + NaOH (aq) H2O (l) + NaF (aq)

Chem 1B Saddleback College Dr. White 1. Experiment 8 Titration Curve for a Monoprotic Acid

Acid Dissociation Constants and the Titration of a Weak Acid

Acid-Base Titrations Using ph Measurements

The Determination of an Equilibrium Constant

1. To perform a potentiometric titration of a sample of Liquid Drano with hydrochloric acid.

EXPERIMENT INTRODUCTION TO INDICATORS AND ACID-BASE TITRATIONS

(1) Hydrochloric acid reacts with sodium hypochlorite to form hypochlorous acid: NaOCl(aq) + HCl(aq) HOCl(aq) + NaCl(aq) hypochlorous acid

Chemistry 119: Experiment 7. Potentiometric Titration of Ascorbic Acid in Vitamin C Tablets

Electrical Conductivity of Aqueous Solutions

Juice Titration. Background. Acid/Base Titration

6 H2O + 6 CO 2 (g) + energy

STANDARDIZATION OF A SODIUM HYDROXIDE SOLUTION EXPERIMENT 14

Determining the Identity of an Unknown Weak Acid

Experiment 4 (Future - Lab needs an unknown)

TITRATION CURVES, INDICATORS, AND ACID DISSOCIATION CONSTANTS

Experiment 17: Potentiometric Titration

Experiment 6 Titration II Acid Dissociation Constant

Nitrogen, Ammonia. Known Addition ISE Method 1 Method Minimum of 0.8 mg/l NH 3 N. Ammonia ISE. Test preparation. Instrument-specific table

Related concepts Kohlrausch s law, equivalent conductivity, temperature dependence of conductivity, Ostwald s dilution law.

Direct ISE Method Method to 1000 mg/l Na + Sodium ISE

Determining the Quantity of Iron in a Vitamin Tablet. Evaluation copy

Determining the Free Chlorine Content of Swimming Pool Water. HOCl H + + OCl. Evaluation copy

Drop Counter Sensor Product Number: ENDRP-AD100

Ascorbic Acid Titration of Vitamin C Tablets This lab will be completed individually! Make sure you come prepared!

Acid Base Titration: ph Titration Curve

3 Energy Content of Food

Analyzing the Acid in Vinegar

The Determination of an Equilibrium Constant

Lab 25. Acid-Base Titration and Neutralization Reactions: What Is the Concentration of Acetic Acid in Each Sample of Vinegar?

Work and Energy. W =!KE = KE f

EXPERIMENT 10: TITRATION AND STANDARDIZATION

Stoichiometry Limiting Reagent Laboratory. Chemistry 118 Laboratory University of Massachusetts, Boston

EXPERIMENT 2 THE HYDROLYSIS OF t-butyl CHLORIDE. PURPOSE: To verify a proposed mechanism for the hydrolysis of t-butyl Chloride.

ENZYME ACTION: TESTING CATALASE ACTIVITY

Stoichiometry Limiting Reagent Laboratory. Chemistry 118 Laboratory University of Massachusetts, Boston

ph: Measurement and Uses

ACID-BASE TITRATIONS: DETERMINATION OF CARBONATE BY TITRATION WITH HYDROCHLORIC ACID BACKGROUND

ph and Acidity in Wine and Fruit Juice

The Determination of Acid Content in Vinegar

POTENTIOMETRIC TITRATION OF A WEAK ACID

Properties of Acids and Bases

9. Analysis of an Acid-Base Titration Curve: The Gran Plot

Reaction of Magnesium with Hydrochloric Acid (Gas Laws) Chemicals Needed:

Where the exp subscripts refer to the experimental temperature and pressure acquired in the laboratory.

Solubility Product Constants

MASSACHUSETTS INSTITUTE OF TECHNOLOGY Department of Chemistry Laboratory Chemistry THE POTENTIOMETRIC TITRATION OF AN ACID MIXTURE 1

Determination of Citric Acid in Powdered Drink Mixes

CHEMICAL DETERMINATION OF EVERYDAY HOUSEHOLD CHEMICALS

Experiment 2 Kinetics II Concentration-Time Relationships and Activation Energy

Experiment 7: Titration of an Antacid

Experiment 3 Limiting Reactants

Chemistry 112 Laboratory Experiment 6: The Reaction of Aluminum and Zinc with Hydrochloric Acid

EXPERIMENT 12 A SOLUBILITY PRODUCT CONSTANT

Chemistry 212 VAPOR PRESSURE OF WATER LEARNING OBJECTIVES

experiment5 Understanding and applying the concept of limiting reagents. Learning how to perform a vacuum filtration.

Enzyme Action: Testing Catalase Activity 50 Points

Experiment 8 - Double Displacement Reactions

TITRATION OF AN ACID; USING A ph METER. The ph meter is an instrument that measures the ph of a solution and affords a

Experiment 6 Coffee-cup Calorimetry

Calcium Analysis by EDTA Titration

Pressure -Temperature Relationship in Gases. Evaluation copy. Figure ml Erlenmeyer flask. Vernier computer interface

AP CHEMISTRY 2010 SCORING GUIDELINES (Form B)

Neutralizing an Acid and a Base

Evaluation copy. Case File 9. A Killer Cup of Coffee? GlobalTech manager dies

Lab #13: Qualitative Analysis of Cations and Anions

Endothermic and Exothermic Reactions. Evaluation copy. Mg(s) + 2 HCl(aq) H 2 (g) + MgCl 2 (aq)

The introduction of your report should be written on the on the topic of the role of indicators on acid base titrations.

USEPA Electrode Method Method 8156

A Potentiometric Analysis of Fluoride Ion in Toothpaste

Evaluation copy. Enzyme Action: Testing Catalase Activity (Method 1 O 2 Gas Sensor) Computer 2

Experiment 18: ph Measurements of Common Substances. Experiment 17: Reactions of Acids with Common Substances

LIGHTSTICK KINETICS. INTRODUCTION: General background on rate, activation energy, absolute temperature, and graphing.

Phosphates (ortho- and total)

EXPERIMENT 7 Electrochemical Cells: A Discovery Exercise 1. Introduction. Discussion

Recovery of Elemental Copper from Copper (II) Nitrate

Neutralization Reactions. Evaluation copy

Enzyme Pre-Lab. Using the Enzyme worksheet and Enzyme lab handout answer the Pre-Lab questions the pre-lab must be complete before beginning the lab.

EDTA Titrations 1: Standardization of EDTA and Analysis of Zinc in a Supplement Tablet. by Professor David Cash. September, 2008

Acid-Base Titrations. Setup for a Typical Titration. Titration 1

III. Chemical Kinetics

Lab #10 How much Acetic Acid (%) is in Vinegar?

Enzyme Action: Testing Catalase Activity

Volumetric Analysis. Lecture 5 Experiment 9 in Beran page 109 Prelab = Page 115

Chapter 10 Acid-Base titrations Problems 1, 2, 5, 7, 13, 16, 18, 21, 25

ph and Acidity in Tomato Sauce

Calibration of Volumetric Glassware

Phenolphthalein-NaOH Kinetics

Determination of the Amount of Acid Neutralized by an Antacid Tablet Using Back Titration

Determining Equivalent Weight by Copper Electrolysis

Physical Properties of a Pure Substance, Water

Enzyme Action: Testing Catalase Activity

Lab #11: Determination of a Chemical Equilibrium Constant

Tutorial 4 SOLUTION STOICHIOMETRY. Solution stoichiometry calculations involve chemical reactions taking place in solution.

Transcription:

Lab Activity 18 CONDUCTOMETRIC TITRATION LAB ACTIVITY 18 Conductometric Titration Background Titration is the a method of determining the concentration of an unknown solution (the analyte) by reacting it completely with a standardized reagent that is a solution of known concentration (the titrant). The point at which all of the analyte is consumed is the equivalence point. The number of moles of analyte is calculated from the volume of reagent that is required to react with all of the analyte, the titrant concentration, and the reaction stoichiometry. Previously, a ph electrode was used to measure the ph of the analyte and to determine when the equivalence point was reached. Another method of determining when the equivalence point is reached is by using a conductivity sensor to measure the conductivity of the analyte. The conductivity of a solution is dependent on several factors, including the concentration of the solute, the degree of dissociation of the solute, the valence of the ion(s) present in the solution, the temperature, and the mobility of the ions in the solution. In this case, we will be titrating a solution of barium hydroxide, Ba(OH) 2, with sulfuric acid, H 2 SO 4. Initially the Ba(OH) 2 will be almost completely dissociated into Ba 2+ and OH -. With the addition of the H 2 SO 4 the following reaction takes place: (1) Ba 2+ (aq) + 2 OH - (aq) + 2 H + (aq) + SO4 2- (aq) BaSO 4 (s) + H 2 O (l) The barium sulfate, BaSO 4, is fairly insoluble and precipitates out of solution. The hydronium and hydroxide ions combine to form water. Neither of the reactant products contribute very much to the conductivity of the solution, thus as the titration takes place the conductivity will decrease. At the equivalence point, when enough H 2 SO 4 has been added to react with the available Ba(OH) 2, the conductance of the analyte is at it s lowest point. Adding more titrant will cause the conductance of the analyte to increase again. Thus a plot of conductance vs. volume of H 2 SO 4 added will result in a V shaped graph. We will take the curve fit for the line on either side of the equivalence point and solve for the intercept of the two lines to derive an exact value of H 2 SO 4 used. Purpose In this lab, you will use a PASPORT Conductivity Sensor and Drop Counter to titrate a barium hydroxide solution of unknown concentration with a sulfuric acid solution of known concentration. You will use your data and the stoichiometry of the reaction to determine the concentration of the barium hydroxide solution. 233

Materials PASCO & Other Equipment PASPORT Xplorer GLX beaker, 150-mL (2) PASPORT Conductivity Sensor w/ 1x Conductivity electrode PASPORT Drop Counter Right-angle clamp Small Tripod Base & Rod Buret Clamp buret, 50-mL graduated cylinder, 100-mL magnetic stirrer and stir bar pipet with bulb, 50-mL wash bottle and waste container protective gear Consumables Barium hydroxide (Ba(OH) 2 ), unknown concentration, 50.0 ml Sulfuric acid (H 2 SO 4 ), 0.02 M, approximately 60 ml Water, distilled, 100mL Safety Precautions Always work in an area that is well ventilated. Follow all directions for using the equipment. Wear safety glasses, gloves, goggles and protective clothing. Do not pipette by mouth. Pre-Lab Questions 1) Sketch the expected appearance of the conductance vs. volume graph. 2) Indicate on the graph when the equivalence point is reached. Procedure Interface Setup 1) Connect the Conductivity electrode to the Conductivity Sensor. Connect the Conductivity Sensor to Port #1 on the GLX 2) Connect the Drop Counter to Port #2 on the GLX. 3) Open the GLX file 18_Cond_Titration.glx. 234

Equipment Setup 1) Set up the equipment as shown in the picture. Use a right-angle clamp to attach the Drop Counter to the support rod. Above the Drop Counter, use a buret or three-finger clamp to affix a buret to the support rod. Ensure the buret valve is closed. Place a magnetic stirrer at the base of the setup. Place the beaker you will be using for the titration on the stirrer. Lower the Drop Counter until it rests just above the beaker. Then lower the buret so that the valve is about one inch above the Drop Counter opening. 2) Use a buret clamp to attach a 50 ml buret to the support rod with the tip about 1 inch above the opening in the drop counter. Ensure the buret stopcock is closed. 3) Fill the buret. Remove the beaker from the magnetic stirrer and replace with a waste beaker. Rinse your buret with 1-2 ml of titrant. Discard as directed. Then, fill your buret with ~50 ml of titrant, making sure not to fill past the top volume gradation. Drain a small amount of titrant through the drop counter into the waste beaker to remove any air in the tip of the buret and then practice adjusting the stopcock so that the titrant goes through the drop counter in distinguishable drops that fall at about 1 second intervals. Close the stopcock. 4) Read the initial volume of titrant in the buret to 0.01 ml. Record the volume and actual concentration of the 0.02 M H 2 SO 4 in your data table. 5) The Conductivity Sensor is normally calibrated for the 10x electrode. Using the 1x electrode (necessary for the low conductivity values found in this experiment) will cause the conductivity values to read ten times higher than the actual value. In this experiment, however, the actual conductivity values are not important and the Conductivity Sensor does not require calibration. 6) Prepare the sample. Use the 50 ml pipet to add 50.0 ml of the barium hydroxide solution to the beaker. Record the volume of the barium hydroxide solution that you added in the data table. Use the graduated cylinder to add an additional 50 ml of distilled water to the beaker. 235

CAUTION: Never pipet by mouth. Always use a pipet bulb or a pipet pump. Be careful when handling any acid or base solutions. 7) Place the sample beaker on the stir plate, under the Drop Counter. 8) Install the supplied vertical stir bar in the end of the Conductivity electrode and insert the Conductivity electrode into one of the holes of the Drop Counter. Turn on the stir plate and begin stirring at a slow to medium speed. 9) The level of the water should be sufficient to cover the flow-through holes on the sides of the Conductivity electrode. If the water level is below the holes of the Conductivity electrode, add more distilled water until the holes are submerged. 10) Carefully examine the holes on the side of the electrode and check if there are any air bubbles trapped in the tip of the electrode. If there are air bubbles trapped in the tip, shake or tap the electrode to dislodge the air bubbles. Record Data 1) From the GLX Home screen, press Graph. Setup the graph to display Conductivity versus Drop Count. From the Home screen press to open the Graph Display. Press to turn on the active fields. Use the Arrow Keys to highlight the Time field (on the horizontal axis) and press to open the data source menu. Select Drop Count (drops) as the data source and press selection. again to accept the The Vertical axis should display conductivity. 2) Press to begin recording data. Turn the buret valve to release the H 2 SO 4 at approximately one drop per second. Press the Autoscale button to resize the titration graph and see the data. 3) Continue adding the H 2 SO 4 titrant to the beaker until the conductivity value stops decreasing and starts to increase. At this point, continue to add between 5-10 ml of H 2 SO 4 and press again to end data recording. 4) Read the final volume of titrant in the buret and record the value in your data table. Calculate the total volume of titrant used. 236

5) Turn off the magnetic stirrer. Remove the Conductivity electrode from the solution. Rinse the Conductivity electrode in distilled water and dry the sensor gently. 6) Dispose of the solution in the beaker as instructed. Analyze Record calculations in your data table on the Student Response Sheet as you complete your analysis. 1) Read the total number of drops counted on the graph and record the final drop count in your data table. 2) In the GLX calculator screen ( from the Home screen), you will see a calculation similar to the one shown below. Modify the calculation using the values from your titration. 3) Return to the graph display. Change the data source for the horizontal axis of the graph from drops to the calculated volume using the procedure described in step 1 under Record Data above. 4) With the Graph displayed, press Tools. Use the Arrow keys to select Linear Fit from the menu and press. The GLX will perform a Linear Fit on the data and display the Slope and Y-intercept data for the curve. The Linear Fit takes into account the data from both sides of the equivalence point; however we need the fit data for one side or the other. You will need to select the data from the side that you wish to analyze. 5) With the Linear Fit selected, you will see a dashed-line Statistics Box. All the data within the Statistics Box will be used to perform the fit. Use the Left and Right Arrow keys to move the data cursor and select a fairly linear region of the graph that is before the equivalence point. If you need to move the start of the Statistics Box, press Tools, use the Arrow Keys to select Swap Cursors and the press 237

. Record the Slope and Y-intercept information that is displayed on the GLX screen for the data points before the equivalence point. 6) Similarly, use the Arrow Keys and Swap Cursor function to select a linear region of the graph that is after the equivalence point. Record the Slope and Y-intercept values shown on the GLX into the data table. 7) Navigate to the GLX calculator by pressing, then. The calculator displays the equation to find the equivalence point: (b2-b1)/(m1-m2). Given the equation of a line (m*x+b) where m is the Slope and b is the Y-intercept, enter the slope and Y- intercept data for before (m1, b1) and after (m2, b2) the equivalence point into the GLX calculator. The resulting answer is the volume of H 2 SO 4 used at the equivalence point. Record this information to the Data Table. 8) Use your recorded information to calculate the number of moles of H 2 SO 4 used at the equivalence point. 9) Use the stoichiometry given in Equation 1 to calculate the number of moles of Ba(OH) 2 and the molarity of the unknown sample. 10) Follow your teacher s instructions regarding cleaning up your workspace. Data Table Item Value Volume of Ba(OH) 2 Concentration of H 2 SO 4 Inital volume of titrant Final volume of titrant Final drop count Volume of titrant used Slope before equivalence point Y-intercept before equivalence point Slope after equivalence point Y-intercept after equivalence point Volume of H 2 SO 4 used at equivalence point Moles of H 2 SO 4 used at equivalence point 238

Moles Ba(OH) 2 in solution Concentration of Ba(OH) 2 solution Analysis and Synthesis Questions 1) Derive the equation to find the equivalence point given the equation of two lines. 2) In this experiment, both the titrant and the analyte were conductive. What might the conductivity vs. volume curve look like if the analyte was not very conductive? 239

240 18 CONDUCTOMETRIC TITRATION LAB ACTIVITY