Operation Manual TPOP MINI. Doc No. OM-1213424-0101. 2.212134240101fro.fm



Similar documents
PLC Control Unit for a CSM-C Steam Compact Clean Steam Generator

Operational Overview and Controls Guide. Two or Three Pump IronHeart Lite with Variable Frequency Drives

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN

Rules for Safe Operation

15GAL STEEL OIL DRAIN WITH 110V PUMP

User manual. 086U6297 Rev. 9 EN

SunMaxx Solar Filling Station Operating Instructions

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

LG Wireless Remote Controller

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Power consumption (kw)

CLEANING IN PLACE AUTOMATION FOR PROCESS INDUSTRY USING PLC AND SCADA SOFTWARE

Ultrasonic support removal tank

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2014/07) en

Instruction manual for Firstline FCS12000CH

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

12 Volt 30 Amp Digital Solar Charge Controller

NESCAFÉ Solution 8/60 Beverage System. Operations Manual

NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL

The MKII Controller Operator s Guide 1

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Bradlee Boilers Ltd. Instruction Manual for starting up Bradlee Hire Boiler from Cold

Alfa Laval PureBallast 3.1

PUSH BUTTON START INSTALLATION MANUAL

Boiler Preparation, Start-Up and Shutdown

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type)

SECTION 13XXX CONTROL DESCRIPTION (DICP Models NC, 412, 622, 826, 1030)

PLEASE READ ALL INSTRUCTIONS BEFORE USE AND SAVE A COPY FOR FUTURE REFERENCE!

INSTALLER S & OWNER S MANUAL

Oil and Coolant Circulating Heating System. Model - OCSM

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

Private Water Supplies Sampling Manual. A Field Guide

Emergency Showers and Eyewash Stations

INSTRUCTION MANUAL. Boil-Out TABLE OF CONTENTS SAFETY WARNINGS 2-3 RESPONSIBILITY 3 INTRODUCTION 3 PRE-BOIL OUT PROCEDURES 3-5 BOIL OUT PROCESS 5-9

High Efficiency Vaporizing System and Highly Durable Heaters Ensure 25% Increased Output.

Support Cleaning Apparatus. Operation, Cleaning, & Safety Manual

MERLIN BEER BOTTLE FILLING MACHINE OPERATING MANUAL

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

PORTABLE AIR CONDITIONER

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

GEORGIA INSTITUTE OF TECHNOLOGY ENVIRONMENTAL HEALTH AND SAFETY PERSONAL PROTECTIVE EQUIPMENT

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

CLEANING IN PLACE IN PHARMACEUTICAL INDUSTRY USING PLC AND SCADA SOFTWARE

STANDARD OPERATING PROCEDURES DIVISION OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...

Inline Chlorinator Chlorine Chemical Feeder

How to read this guide

Convection Ovens. BX Classic. Models BX4 / FG 189C, BX / FG 158C, BX10 / FG 180C. Operator's Manual

PARAGON ELECTRIC, INC. LIQUID LEVEL CONTROLLER USER MANUAL MODELS: LLC-I, LLC-II AND TELEMETRY OPTIONS

User manual. Solid (FR 98,),

Tassimo The Art of the Perfect Cup

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance

Portable Air Conditioner

Hydraulic control unit series

Safety Data Sheet Avesta Neutralization Agent 502

Thermo Top - Troubleshooting Tree

Operators Manual. Use and Care Instructions Electric Models, SteamCraft Ultra 3, 5, 10. Series: 21CET8, 21CET16, 24CEA10. Part No. CET-OPM Rev A 1/01

National- Spencer Inc.

Safety Requirements Specification Guideline

Ambiente Quick Reference Manual

Operational Overview and Controls Guide

Users Instructions BQ3030 THESE INSTRUCTIONS TO BE RETAINED BY USER

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Conforms to Regulation (EC) No. 1907/2006 (REACH), Annex II and Regulation (EC) No. 1272/2008 (CLP) - Europe. Bona Wood Floor Cleaner

Industrial Process Pump Safety Manual IMPORTANT SAFETY NOTICE

TEMPLE UNIVERSITY ENVIRONMENTAL HEALTH AND RADIATION SAFETY

Overheating limit control

SERVICE MANUAL RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS. Troubleshooting Guide and Instructions for Service

SIMATIC HMI. WinCC flexible 2008 Getting Started - First-Time Users Getting Started. Printout of the Online Help 06/2008 A5E

Instruction Manual for Operating Panel 301 and 302

USER MANUAL HRV CONSTRUCTO 2.0ES* HRV CONSTRUCTO 1.5ES* * THESE PRODUCTS EARNED THE ENERGY STAR BY MEETING STRICT ENERGY EFFICIENCY

Domestic heat pumps. DHP-A Opti DHP-C Opti DHP-C Opti W/W DHP-H DHP-H Opti DHP-H Opti Pro/Opti Pro + DHP-L DHP-L Opti DHP-L Opti Pro/Opti Pro +

SET-UP AND TECHNICAL MANUAL

SIMATIC. WinCC V7.0. Getting started. Getting started. Welcome 2. Icons 3. Creating a project 4. Configure communication 5

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

Training on Standard Operating Procedures for Health Care Waste Management Swaziland 12 May, 2011

IMPORTANT SAFETY NOTICE

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

REMOTE CONTROL MANUAL

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

USER MANUAL OPERATION AND USE OF CAR WITH. Diego G3 / NEVO SEQUENTIAL GAS INJECTION SYSTEM

Standard Operating Procedure (SOP) Car/Truck Battery Safety

Error Codes: 02F. Model: (110. = Whirlpool) S/N: CSP Type: 199-AKP 705/WT. Sears Kenmore/Whirlpool Front Load Washer

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Please also see 10 golden rules for correct Saniflo installation on

Operating Manual Color Changing Fountains

TIG INVERTER INSTRUCTION MANUAL

Heavy Fuel Oil supply units. The world s best selling HFO supply unit. The right choice for any conditions

PBX Series Quick Fit Connector Bimetallic Steam Traps

Installation Instructions for Alarm Module Kit A043F059

Use and Care Manual. Model CPA12KH AIR CONDITIONER

GENERATOR TRANSFER SWITCH

Introduction. Section 2. Introduction 2-1

Presented by: Rich Perry Marsh Risk Consulting

Use and Care Instructions Dual Gas Steam Generator & Convection Steamer

Material Safety Data Sheet

Transcription:

OM Operation Manual Tetra Alcip 10 TPOP MINI 2.212134240101fro.fm

This document is valid for: Series No/ Machine No OM Operation Manual 2.212134240101fro.fm Issue 2002-01 Tetra Pak Dairy & Beverage Systems AB

Table of contents Introduction.................................... 1 Equipment.......................................... 1 Document........................................... 2 Safety precautions.............................. 3 Use of hazard information.............................. 3 General............................................ 4 Cleaning solution..................................... 5 General description.............................. 7 Application.......................................... 7 Requirements on personnel............................. 7 Operator station...................................... 7 Risk area........................................... 7 Denominations....................................... 8 Process description............................ 11 2.212134240101toc.fm Control panel.................................. 19 Denomination....................................... 19 General rules for indication............................ 20 Control system menu tree............................. 23 List of alarms....................................... 37 Preparations.................................. 39 Manual preparation.................................. 39 Preparation with metering pump........................ 41 Preparation using the by-pass.......................... 42 Operation..................................... 45 Initial start of cleaning................................ 45 Cleaning of package machine (optional).................. 46 Initial start of stations programs......................... 47 Stepping of cleaning cycle............................. 47 Drain of tank........................................ 48 Tetra Alcip 10 TPOP MINI i

Table of contents Cleaning...................................... 49 Settings...................................... 51 Inspection/change of parameter values................... 51 Inspection/change of controllers........................ 53 2.212134240101toc.fm ii Tetra Alcip 10 TPOP MINI

Introduction Introduction This section contains basic information about this manual and the Tetra Pak equipment described. 2.2 tf501632en.fm WARNING! To ensure maximum safety, always read the section Safety precautions before carrying out any work on the unit. Equipment Intended use of this Tetra Pak equipment This unit is intended for use according to the specifications in Technical data (see Technical Manual) and related documents. Tetra Pak will not be held responsible for injury or damage if the equipment is used for any other purpose. Service If problems are encountered when operating the unit, contact the nearest Tetra Pak service station. Manufacturer This Tetra Pak equipment was produced by: Tetra Pak Dairy & Beverage Systems AB Box 64 S-221 00 LUND Sweden Unit identification All units carry a machine plate stating: unit identification data unique to the unit Have this information available before contacting Tetra Pak concerning this particular unit. Machine Type Drawing Spec. Machine No. Manufacturer Tetra Pak Year of manufacture Tetra Alcip 10 TPOP MINI 1

Introduction Document Operation Manual (OM) The purpose of this Operation Manual is to provide the operator with information on how to operate the machine. Tetra Pak recommend that you study it carefully, and - above all - ensure its availability to those who will be operating the unit. Furthermore, it is important that you: keep the manual for the life of the equipment pass the manual on to any subsequent owner or user of the equipment. Tetra Pak will not be held responsible for any breakdown of the equipment caused by the owner s failure to follow the instructions given in this manual. Design modifications The information given in this document is in accordance with the design and construction of the machine at the time it was delivered by the Tetra Pak machine production facility. Further copies Additional copies can be ordered from the nearest Tetra Pak service station. When ordering technical publications, always quote the document number printed on the front cover of the document concerned. Document producer This document was produced by: Tetra Pak Dairy & Beverage Systems AB Box 64 S-221 00 LUND Sweden Number of pages This document contains a total of 56 pages. 2.2 tf501632en.fm Copyright 2001 Tetra Pak Dairy & Beverage Systems AB All rights reserved. No parts of this document or application software used in the product may be edited, reproduced or copied in any form or by any means without the written permission of Tetra Pak Dairy & Beverage Systems AB. 2 Tetra Alcip 10 TPOP MINI

Safety precautions Safety precautions To ensure maximum safety for the operator, always read this section carefully before carrying out any work on the machine or making any adjustments. Use of hazard information DANGER! Failure to observe this information results in immediate danger to life. WARNING! Caution! Failure to observe this information can result in major personal injury or loss of life Failure to observe this information can result in minor personal injury or damage to the equipment. 2.2 tf000017en.fm Tetra Alcip 10 TPOP MINI 3

Safety precautions General Only trained personnel are allowed to operate the machine. The machine may only be used in accordance with the instructions given in the manuals delivered with the equipment. If the safety precautions are not followed, there is risk of personal injury. This is an automated machine. It is controlled by a process controller and will change its mode of operation without operator intervention. All personnel must therefore: stay outside the safety area regard all electrical equipment as live regard all pipes as hot use hearing protection. Before carrying out maintenance and repair: shut off main steam supply switch off power allow the machine to cool down and adjust to atmospheric pressure rinse out concentrated chemicals and cleaning solution with water from pipes and pumps inform the operator and other relevant personnel about the work you intend to do post warning signs in prominent places. 2.2 tf000017en.fm Pipes and other parts of this machine may be hot. Contact with hot equipment may result in severe burns. Avoid contact with hot equipment. This machine operates under pressurized conditions. All personnel must therefore: watch out for leakage depressurize the equipment before attempting maintenance and repair work watch out for blasts of air/steam from safety valves. Keep the doors of the control panel closed to protect it from water and steam. 4 Tetra Alcip 10 TPOP MINI

Cleaning solution Safety precautions Handling of cleaning solution Cleaning solutions normally contain caustic soda (NaOH) or nitric acid (HNO 3 ). These chemicals may cause burning to skin and eyes. Follow the instructions given by the supplier. Whenever there is a risk of exposure to these chemicals, always wear: safety glasses protective gloves shoes made of PVC or PE plastic, or rubber apron. In the case of an accident involving cleaning solution, the basic rule is to rinse the affected area as soon as possible with as much water as possible. For this reason, always make sure that the showers work, that there are additional washing facilities, and that an eyewash device is available at or near each machine site. 2.2 tf000017en.fm Emergency precautions If swallowed If you happen to swallow cleaning solution: drink large amounts of lukewarm water (in order to dilute the cleaning solution); then seek medical attention immediately. Contact with eyes If cleaning solution is splashed into your eyes: wash the eyes thoroughlywith lukewarm water for 15 minutes (keep eyelids widely apart); then seek medical attention immediately. Contact with skin or clothes If cleaning solution comes into contact with skin or clothes: rinse immediately with plenty of water thoroughly wash the clothes before they are worn again. If skin burns appear, seek medical advice immediately. If inhaled If you experience irritation or pain due to having inhaled vaporized cleaning solution: leave the affected area to get fresh air. If the symptoms become worse, seek medical advice. Tetra Alcip 10 TPOP MINI 5

Safety precautions This page intentionally left blank 2.2 tf000017en.fm 6 Tetra Alcip 10 TPOP MINI

General description General description Application All food products demand a very strict standard of hygiene in the manufacturing process. The raw materials (e.g. milk, juice, beer) are in contact with a number of surfaces, all of which are potential sources of infection. Sterilization can reduce but not entirely eliminate the consequences of such an infection. The cleaning and disinfection equipment is therefore a most important aspect of the processing in a food plant. Tetra Alcip 10 is a complete, frame mounted, Cleaning-in-place unit designed especially to meet the requirements of the food industry. 2.2 tf501336en.fm Caution! Control of the CIP is carried out by a process control system, once the program has been started, the cleaning sequence is fully automatic regarding times, temperatures, routing of liquids etc. Requirements on personnel Operator: basic knowledge of industrial processes. Unauthorized personnel Operation by unauthorized personnel may endanger personnel and property. Operator station In front of the control panel. Risk area 2-3 metres around the equipment due to: hot pipes and equipment jets of hot liquid Tetra Alcip 10 TPOP MINI 7

General description Denominations 8 9 7 10 6 5 2 3 4 1 11 12 13 Symbol 14 15 Disinfectant metering pump Lye metering pump 2.2 tf501336en.fm Acid metering pump GF100604 1 Acid buffert tank (option) 2 Acid metering pump (option) 3 Lye metering pump (option) 4 Lye buffert tank (option) 5 Level switch 6 Plate heat exchanger 7 Flow switch 8 Steam regulating valve 9 Flow meter 10 Control panel 11 Conductivity transmitter 12 Flow regulating valve 13 Pressure pump 14 Steam trap 15 Balance tank 8 Tetra Alcip 10 TPOP MINI

General description 2.2 tf501336en.fm Buffer tanks The buffer tanks are used to: prepare cleaning solution contain cleaning solution to minimize cleaning solution losses The tanks are equipped with low level switches indicating when the tanks are empty. Control panel Contains all equipment necessary for: indication of process status supervision of process performance control of automatic functions Tetra Alcip automation is based on a process controller. This controller features: process sequence control timers control loops text display numeric and function keyboard Plate heat exchanger (PHE) PHE is used to heat the cleaning solution with use of steam. The plates are assembled in packs and clamped in a frame, each adjacent pair of plates forming a flow channel with the two media flowing in alternate channels. Two or more sections can be housed in the same frame. Tetra Alcip 10 TPOP MINI 9

General description This page intentionally left blank 2.2 tf501336en.fm 10 Tetra Alcip 10 TPOP MINI

TE 3 TE 1 Process description Process description Presented here is a flow chart simplified to enhance the understanding of the process. Please see complete flowchart in Technical Manual for details. Water Water Lye Acid M M 2 Water Lye tank Acid tank Rinse water tank CIP return CIP pressure 2.2 tf501607en.fm Balance tank Flow during circulation Cleaning liquid is pumped by pump M1 out to the process lines/cip circuits. Returning cleaning liquid flows back to the Tetra Alcip via CIP return pipes Cleaning liquid flows: during lye circulation: through V103, M1, cleaning object, V113, and the CIP-solution tank, during acid circulation: through V102, M1, cleaning object, V112 and the CIP-solution tank. Flow to drain Returning flow is routed to drain via V151. Flow during disinfection (Option) Disinfectant is pumped into the CIP circuit via the metering pump M9 and the disinfection solution is circulated over the balance tank. Tetra Alcip 10 TPOP MINI 11

Process description Flow during rinse Water flows via V100, V101 and pump M1 out to the process lines. Remaining (in the pipes) cleaning liquid flows back to the Tetra Alcip via CIP return pipes. The mixture of cleaning liquid/water, and finally pure water, is routed to drain via V151. Flow during recovery Returning cleaning solution is routed to appropriate CIP-solution tank, or rinse water tank. Flow during hot water circulation Water is circulated through the cleaning circuit, by-passing the balance tank. Cleaning of Active Cleaning Objects (ACO) The cleaning sequence is controlled by the ACO; the Tetra Alcip merely executes the commands received. The ACO can command the Tetra Alcip to: stand-by for cleaning of ACO, deliver liquid, collect liquid, heat the liquid being delivered. The liquids available depends on the Tetra Alcip configuration (lye, acid, rinse water). The conductivity instrument sorts the returned liquid to a tank or to drain. 2.2 tf501607en.fm Cleaning sequence step programmes Tetra Alcip supports 11 types of programmes and a total of 16 cleaning circuits. Preparation & emptying programs Cleaning programmes 31. Lye preparation 1. Lye 32. Acid preparation 2. Acid 41. Lye emptying 3. Lye and acid 42. Acid emptying 4. Disinfection 52. Rinse water emptying 5. Hot water 6. Flush 12 Tetra Alcip 10 TPOP MINI

Programme sequence steps Process description No Description Note 1 Water to object Water is flushed through the cleaning circuit for a preset time. Heating is started. 21 Lye to object Water in the circuit is purged to drain by lye solution until lye reaches concerned circuit. 22 Empty object Pump and heating stops during a preset time to allow the tank to be completely drained. 23 Lye to CIP unit Heating restarts and water in the circuit is purged to drain by lye solution until the conductivity transmitter in the return pipe detects the lye solution. This step is supervised by a min. and a max. time. 24 In-line dosing Lye solution is dosed while water is circulated for a preset time. Water from balance tank if rinse water does not exist In-line system: water from circulation tank The step is jumped by unless Tank is configured in Object type selection. In line system: water from circulation tank, maximum filling time is used as step condition. The step is jumped by if In-line system is not configured 2.2 tf501607en.fm 25 Lye circulation Hot lye is circulated during a preset time. If temperature drops below a preset value the time counting will stop. Time counting restarts when correct temperature is achieved. 30 Empty balance tank balance tank is completely emptied. The step is jumped by if In-line system is not configured 31 Water to object Lye in the circuit is purged to lye tank by water until water reaches concerned circuit. In-line system: return to drain. 32 Empty object Pump and heating stops during a preset time to allow the tank to be completely drained. 33 Lye recovery Water purges the lye in the circuit to the CIP solution tank. Purge continues until the conductivity transmitter in the return pipe detects water. This step is supervised by a minimum and a maximum time. 41 Acid to object Water in the circuit is purged to drain by acid solution until acid reaches concerned circuit. The step is jumped by unless Tank is configured in Object type selection. 42 Empty object Pump and heating stops during a preset time to allow the tank to be completely drained. The step is jumped by unless Tank is configured in Object type selection. Tetra Alcip 10 TPOP MINI 13

Process description No Description Note 43 Acid to CIP unit Heating restarts and water in the circuit is purged by acid solution until the conductivity transmitter in the return pipe detects the acid solution. This step is supervised by a min. and a max. time. 44 In-line dosing Acid solution is dosed while water is circulated for a preset time. 45 Acid circulation Hot acid is circulated during a preset time. If temperature drops below a preset value the time counting will stop. Time counting restarts when correct temperature is achieved. 50 Empty balance tank Balance tank is completely drained. In-line system: water from balance tank, maximum filling time is used as step condition. The step is jumped by if In-line system is not configured The step is jumped by if In-line system is not configured 51 Water to object Acid in the circuit is purged to acid tank by water until water reaches concerned circuit. 52 Empty object Pump and heating stops during a preset time to allow the tank to be completely empty. 53 Acid recovery Water purges the acid in the circuit to the CIP solution tank. Purge continues until the conductivity transmitter in the return pipe detects water. This step is supervised by a minumun and a maximum time. 61 Hot water circulation Water is circulated for a preset time. If the temperature drops below a preset value the time counting will stop. Time counting restarts when correct temperature is achieved. 62 Final hot water rinse Water flows through the circuit to drain for a preset time. 71 Water to object Water is sent to the circuit for a preset time. 72 Empty object Pump and heating stops during a preset time to allow the tank to be completetly drained. 73 Water to CIP unit Heating restarts and water in the circuit is flushed to drain fo a preset time. 74 In-line dosing Disinfection is dosed while water is circulated for a preset time. In-line system: return to drain. The step is jumped by unless Tank is configured in Object type selection. The step is executed only if temperature setpoint is > 0 ºC. The step is jumped by unless Tank is configured in Object type selection. 2.2 tf501607en.fm 14 Tetra Alcip 10 TPOP MINI

Process description No Description Note 75 Disinfection circulation Water and disinfection is circulated during a preset time. If temperature drops below a preset value the time counting will stop. Time counting restarts when correct temperature is achieved. 76 Empty balance tank Balance tank is completely emptied. 77 Final disinfection rinse Water flows through the circuit to drain for a preset time. 81 Water to object Water is flushed through the circuit to drain for a preset time. 91 Empty object Pump and heating stops during a preset time to allow the tank to be completetly drained. Return to rinse water tank if program no. 6 is not operating. Return to rinse water tank if program no. 6 is not operating. (The step is jumped by unless Tank is configured in Object selection) 2.2 tf501607en.fm Tetra Alcip 10 TPOP MINI 15

Process description Indications during cleaning of ACO A step sequence is not used in Tetra Alcip during cleaning of ACO. The function/command in progress is indicated on the operators panel (TPOP as a three digit value. 1:st digit = 8 = 9 Cleaning of ACO Cleaning of ACO a 2:nd digit request command function 3:rd digit return command function a. with the conductivity transmitter activating the return valve defined by the return function The following values are used for the 2:nd and 3:rd digit. Function 2:nd digit request 3:rd digit request None 0 0 Lye 6 6 Acid 5 5 Water 4 4 a 2.2 tf501607en.fm Rinse water 3 3 Closed return - 1 a. When return to balance tank during Hot water circulation. 16 Tetra Alcip 10 TPOP MINI

Cleaning programmes The following steps are utilised in the different programmes: Process description 2.2 tf501607en.fm Step 1. Lye Step 2. Acid Step 3. Lye and acid 1 Water to object. 1 Water to object. 1 Water to object. 21 Lye to object. 41 Acid to object. 21 Lye to object. 22 Empty object. 42 Empty object. 22 Empty object. 23 Lye to CIP unit. 43 Acid to CIP unit. 23 Lye to CIP unit. 24 In-line dosing. 44 In-line dosing. 24 In-line dosing. 25 Lye circulation 45 Acid circulation. 25 Lye circulation 30 Empty balance tank 50 Empty balance tank. 30 Empty balance tank 31 Water to object. 51 Water to object. 31 Water to object. 32 Empty object. 52 Empty object. 32 Empty object. 33 Lye recovery. 53 Acid recovery. 33 Lye recovery. 81 Water to object. 81 Water to object. 81 Acid to object. 91 Empty object. 91 Empty object. 91 Empty object. - - - - 41 Acid to CIP unit. - - - - 42 In-line dosing. - - - - 43 Acid circulation. - - - - 44 Empty balance tank. - - - - 45 Water to object. - - - - 50 Empty object. - - - - 51 Acid recovery. - - - - 52 Water to object. - - - - 53 Empty object. - - - - 81 Acid to object. - - - - 91 Empty object. Step 4. Disinfection Step 5. Hot water Step 6. Flush 71 Water to object. 61 Hot water 81 Water to object. 72 Empty object. 62 Final hot water 91 Empty object. rinse 73 Water to CIP unit. 91 Empty object. - - 74 In -line dosing. - - - - 75 Disinfection circulation. - - - - 76 Empty balance - - - - tank. 77 Final disinfection - - - - rinse. 91 Empty object. - - - - Tetra Alcip 10 TPOP MINI 17

Process description Preparation and emptying programmes The following steps are utilised in the different programmes: Step 31. Lye preparation (no by-pass) Step 31. Lye preparation (option by-pass) 113 Lye dosing 105 Fill detergent tank 106 Circulation before concentration check 107 Intermediate circulation between concentration checks 108 Lye concentration check 109 Add lye to detergent tank 110 Lye tank heating and temperature check 111 Water flush and collection of diluted lye 135 Final flush, pause 136 Final flush Step 32. Lye emptying 125 Lye emptying 135 Final flush, pause 136 Final flush Step 41. Acid preparation (no by-pass) Step 41. Acid preparation (option by-pass) 123 Acid dosing 115 Fill detergent tank 2.2 tf501607en.fm 116 Circulation before concentration check 117 Intermediate circulation between concentration checks 118 Acid concentration check 119 Add acid to detergent tank 120 Acid tank heating and temperature check 121 Water flush and collection of diluted acid 135 Final flush, pause 136 Final flush Step 42. Acid emptying Step 52. Rinse water emptying 127 Acid emptying 129 Rinse water emptying 136 Final flush 136 Final flush 18 Tetra Alcip 10 TPOP MINI

Control panel Denomination 1 Operator s panel 2 Conductivity instrument 3 Emergency stop button 4 Mains switch 5 Selector switch, remote control 1 = Tetra Alcip is operated from a remote system 0 = Tetra Alcip is operated from the TPOP on the control panel Control panel 6 Cleaning indication lamp (green) steady light; CIP sequence running flashing light; CIP sequence held 7 Alarm indication lamp (yellow): steady light; acknowledged alarm flashing light; unacknowledged alarm Tetra Alcip 10 2.2 tf501608en.fm Tetra Alcip 10 TPOP MINI 19

Control panel General rules for indication Local/Remote control Local/Remote is selected by means of a key switch on the front of the control panel. Local control means that the plant is operated from the TPOP. It is still possible to change pictures and view the application from the remote control unit, but it is not possible to operate the module If the key is in remote position the module can be operated from the TPOP, a remote control system or remote I/O (ACO CIP). Local control Remote control Remote I/O control Function symbols Functions available in the plant are indicated with a symbol. When the symbol is possible to select it appears as a Push-button. A recessed symbol indicates the function has been selected. 2.2 tf501608en.fm Selectable function Selected function 20 Tetra Alcip 10 TPOP MINI

Control panel Common function symbols and indications These function symbols indications are represented on several of the pictures Date and time Current step number Accumulated step time Step duration preset Alarm symbol Stop Start Confirm start/stop Leave the picture 2.2 tf501608en.fm Restricted functions The access code push-button is available in the Overview picture. To get access to the restricted functions push the access code push-button and enter the correct access code with the numerical keys. Following functions need access code: Manual step Regulator picture Editing parameters When entering correct code: green light If incorrect code is entered: blue light with a cross The correct code is valid until a incorrect code is entered or maximum 20 minutes Tetra Alcip 10 TPOP MINI 21

Control panel CIP module status These function symbols are represented on Overview and Operating picture CIP module not ready CIP module ready but last program manually completed Background: green and blue CIP module running Background: green CIP module temporary stopped but no severe alarm Background: green and yellow CIP module held, severe alarm on CIP module Background: yellow CIP module ready and last program properly completed Background: green and blue CIP module not ready, last program properly completed Background: blue 2.2 tf501608en.fm 22 Tetra Alcip 10 TPOP MINI

Control system menu tree Control panel Operation picture Overview picture Station selection picture Service picture Alarm log picture 2.2 tf501608en.fm Flowchart picture Parameter edit picture Language picture Temperature controller picture Parameter list picture Trend diagram picture Tetra Alcip 10 TPOP MINI 23

Control panel Overview picture 1 2 3 4 1 Bring up the OPERATION PICTURE see page 26 2 Bring up the NUMERICAL KEY PICTURE for entering acces code, see page 36 3 Bring up the SERVICE PICTURE see page 33 4 Bring up the ALARM LOG PICTURE see page 30 2.2 tf501608en.fm 24 Tetra Alcip 10 TPOP MINI

Flowchart picture Control panel 5 3 2 1 4 6 2.2 tf501608en.fm 1 Level indication symbol; low level in tank. 2 Valve symbol, green when active. 3 Displays temperature on return side; setpoint black field, measured value white field. 4 Displays temperature in the detergent tank; setpoint black field, measured value white field. 5 Displays conductivity on return side; setpoint black field, measured value white field. 6 Bring up the TEMPERATURE CONTROLLER PICTURE see page 27. Displays temperature on pressure side; setpoint black field, measured value white field. Tetra Alcip 10 TPOP MINI 25

Control panel Operation picture 3 4 5 2 6 7 1 8 1 Bring up the THE NUMERICAL KEY PICTURE see page 36 Display shows current CIP programme. 2 Bring up the NUMERICAL KEY PICTURE, see page 36. Display shows current CIP circuit. 3 Confirm chosen CIP circuit 4 Indicate CIP circuits ready for cleaning. 5 Indicate CIP circuits selected or running. 6 Bring up the CIP MODULE FLOWCHART PICTURE see page 22. See also CIP module status 7 Bring up the STATION SELECTION PICTURE, see page 34. 8 Manual step, used for forcing the cleaning cycle to step forward. 2.2 tf501608en.fm 26 Tetra Alcip 10 TPOP MINI

Temperature controller picture Control panel 2.2 tf501608en.fm 1 Bar graph and numeric display of the input signal to the regulator. 2 Bar graph and numeric display of the setpoint for the regulator. 3 Bar graph and numeric display of the output signal of the regulator. 4 Auto mode 5 Manual mode 6 Bring up the NUMERICAL KEY PICTURE for change of setpoint setting see page 36. 7 Bring up the NUMERICAL KEY PICTURE for change of manual outputsee page 36. 8 Bring up the NUMERICAL KEY PICTURE for change of gain setting see page 36. 9 Gain setting for the utilized sequence step. 10 Bring up the NUMERICAL KEY PICTURE for change of integration time see page 36. 11 Integration time for the utilized sequence step. Tetra Alcip 10 TPOP MINI 27

Control panel Parameter edit picture 1 Bring up the PARAMETER LIST PICTURE see page 32. 2 Toggles up/down available circuits parameters. 3 Toggles up/down (3 step toggle) available circuits parameters. 4 Displays shows next parameter number/parameter value up/down. 5 Bring up the NUMERICAL KEY PICTURE ee page 36.. The displays shows parameter number/ parameter value. 6 Bring up the NUMERICAL KEY PICTURE see page 36. Display shows current CIP circuit number 2.2 tf501608en.fm 28 Tetra Alcip 10 TPOP MINI

Date and time picture Control panel 2 1 2.2 tf501608en.fm 1 Selected pushbutton brings up the the NUMERICAL KEY PICTURE for setting of date and time for the PLC, see page 36. 2 Selected pushbutton brings up the the NUMERICAL KEY PICTURE for setting of date and time for the TPOP see page 36. Tetra Alcip 10 TPOP MINI 29

Control panel Alarm log picture 1 An active alarm is indicated by black text on yellow background togheter with a time stamp in the first column. When the alarm is cleared, the text appears on white background with a time stamp in the second column. When the alarm list is full the logged data is cleared according to the principle first-in-first-out. 2.2 tf501608en.fm 1 Acknowledge alarm 30 Tetra Alcip 10 TPOP MINI

Trend diagram picture Control panel 2.2 tf501608en.fm 1 Trend curve for temperature (TE) 2 Trend curve for concentrate (QE) Tetra Alcip 10 TPOP MINI 31

Control panel Parameter list picture 1 Parameter number 2 Parameter value 2.2 tf501608en.fm 32 Tetra Alcip 10 TPOP MINI

Service picture Control panel 2.2 tf501608en.fm 1 Bring up the PARAMETER EDIT PICTURE see page 28. 2 Bring up the TREND DIAGRAM PICTURE ee page 31. 3 Change brightness in picture 4 Bring up the DATE AND TIME PICTURE ee page 29. 5 Bring up the LANGUAGE PICTURE ee page 34. Tetra Alcip 10 TPOP MINI 33

Control panel Language picture 1 Selectable languages 2 Selected language 2.2 tf501608en.fm 34 Tetra Alcip 10 TPOP MINI

Station selection picture Control panel 2.2 tf501608en.fm 31 Lye preparation 32 Lye emptying 41 Acid preparation 42 Acid emptying 52 Rinse water emptying Tetra Alcip 10 TPOP MINI 35

Control panel 1 2 Numerical key picture 3 4 5 6 7 8 9 1 Selected parameter to be changed 2 Current value of selected parameter 3 If an entered value exceeds the min-max limits, there will be a flashing Indication: Max (Min) value exceeded. 4 Maximum permitted value of selected parameter 5 Entered value of selected parameter 6 Minimum permitted value of selected parameter 7 Back space 8 Enter new value 9 Leave the picture 2.2 tf501608en.fm 36 Tetra Alcip 10 TPOP MINI

List of alarms Control panel Caution! Fault indication Always investigate the cause of a fault indication. Otherwise you may endanger the equipment. Alarms are divided into two categories as follows: A Faults that will cause an alarm only. They are not critical but the operator should investigate the cause. B Faults that will cause a temporary stop. Rectify the fault. See section "Maintenance" in the technical manual (TeM) for trouble shooting chart. Type Text in alarm menu Fault A Temp fault return pipe Temperature fault return pipe A Low conc. return pipe Low concentration return pipe A High level circ. tank High level balance tank A Too high conc.return pipe Too high concentration return pipe (only ACO) 2.2 tf501608en.fm B Motor fault M1 Feedback fault on pressure pump B Motor fault M9 Feedback fault on disinfection metering pump B No flow in return pipe No flow in return pipe B Low level in circ. tank Low level in balance tank B Low level in lye tank Low level in lye tank B Low level in acid tank Low level in acid tank B Low airpressure Low pressure on air supply B Emergency stop activated Emergency stop activated B Temp. fault pressure side Temperature fault pressure side B Host communication fault Communication fault with host computer B Detergent tank not available Detergent tank not available (only ACO) Detergent tank interlocked (only if several pressure lines) B Circuit x not ready Circuit x not ready B AFM x feedback fault Valve or boosterpump feedback fault Tetra Alcip 10 TPOP MINI 37

Control panel This page intentionally left blank 2.2 tf501608en.fm 38 Tetra Alcip 10 TPOP MINI

Preparations Preparations WARNING! Chemical hazard Cleaning solutions normally contain caustic soda or acid. These chemical may cause burning to skin and eyes. Before proceeding read the Safety precautions. Manual preparation a) Check that required utilities are available: Water (pressure), OPEN MANUAL SHUT OFF VALVE Steam (pressure), OPEN MANUAL SHUT OFF VALVE Air (pressure), OPEN MANUAL SHUT OFF VALVE Electricity b) Calculate the amount of concentrated lye and acid necessary to achieve the correct concentration of cleaning solutions. 2.2 tf501609en.fm L = V ( ) DC C -1 where V is water volume in buffer tank C is required concentration of detergent solution in weight % DC is concentrated detergent concentration in weight % L is concentrated detergent needed, litres Example: 1000 ( ) 0.45 0.012 = 27.4 litres -1 Tetra Alcip 10 TPOP MINI 39

Preparations Preparation of lye a) Check that the MANUAL DRAIN VALVE V013 for the buffer tank is CLOSED. b) OPEN MANUAL WATER VALVE V023 to 50% to fill water into the lye buffer tank. c) When the water level reaches the water inlet pipe: ADD gently the concentrated lye into the buffer tank via the man hole. d) When the buffer tank is filled to required level (water + lye): CLOSE MANUAL WATER VALVE V023. Preparation of acid a) Check that the MANUAL DRAIN VALVE V013 for the buffer tank is CLOSED. b) OPEN MANUAL WATER VALVE (V022) to 50% to fill water into the acid buffer tank. c) When the water level reaches the water inlet pipe: ADD gently the concentrated acid into the buffer tank via the man hole. d) When the buffer tank is filled to required level (water + acid): CLOSE THE MANUAL WATER VALVE (V022). 2.2 tf501609en.fm 40 Tetra Alcip 10 TPOP MINI

Preparation with metering pump Preparations L -------= S CS where L is concentrated detergent needed, litres CS is capacity of metering pump, litres/second S is required metering pump run time, seconds to make a complete preparartion Example: 27, 4 -------------- = 498 0,055 seconds 2.2 tf501609en.fm a) Check the capacity of the metering pumps b) Calculate required dosing times c) Update parameter (see section Commissioning in Technical Manual) 1 FOR LYE 13 FOR ACID d) Check the level for concentrated lye and acid. Adjust if necessary. Preparation of lye (no by-pass valve) a) Check that the MANUAL DRAIN VALVE V013 for the buffer tank is CLOSED. b) OPEN MANUAL WATER VALVE V023 to 50% to fill water into the lye buffer tank. c) Display the STATION PROGRAM picture. see page 47 and start the desired station program Preparation of acid (no by-pass valve) a) Check that the MANUAL DRAIN VALVE V013 for the buffer tank is CLOSED. b) Open MANUAL WATER VALVE V022 to 50% to fill water into the acid buffer tank. c) Display the STATION PROGRAM picture. see page 47 and start the desired station program. d) When the buffer tank is filled to required level, CLOSE MANUAL WATER VALVE V023 (If lye preparation) V022 (If acid preparation) Tetra Alcip 10 TPOP MINI 41

Preparations Preparation using the by-pass a) Display the STATION PROGRAM picture. see page 47 and start the desired station program. b) The detergent tank is filled to LSH with water, fresh water is taken from the circulation tank. The steam valve is activated and the steam starts to heat up the cleaning solution. c) Detergent tank level reach LSH. d) Circulation of detergent tank starts and continues for a preset time (parameter). e) Intermediate circulation of detergent tank starts and continues for a preset time (parameter). f) Check of concentration starts. If concentration is below setpoint (parameter) the program continues on step g). If concentration is correct the program continues on step h). g) Filling of remaining concentrated detergent starts. Metering pump for concentrated detergent is activated for a (by the program) calculated time. When the time has elapsed the program continues on step e). h) Check of temperature starts. When the temperature reaches setpoint (parameter), the steam valve closes. i) Water is flushed into the system to sort out and collect the cleaning solution in the pipes to the detergent tank. j) Water is flushed to drain for a preset time (parameter). 2.2 tf501609en.fm 42 Tetra Alcip 10 TPOP MINI

TE 3 TE 3 TE 1 TE 1 Preparations Water Water Lye Acid M M 2 Water Lye tank Acid tank Rinse water tank CIP return CIP pressure Balance tank Flow during preparation, filling of lye tank 2.2 tf501609en.fm Water Water Lye Acid M M 2 Water Lye tank Acid tank Rinse water tank CIP return CIP pressure Balance tank Flow during preparation, lye circulation Tetra Alcip 10 TPOP MINI 43

Preparations This page intentionally left blank 2.2 tf501609en.fm 44 Tetra Alcip 10 TPOP MINI

Operation Circuit display Initial start of cleaning 1 a) Display the OPERATION PICTURE. 2.2tf501610en.fm Select CIP circuit program b) Select PRG PUSH-BUTTON to display the numerical key picture c) Use the numerical key to enter the desired CIP circuit program, see chapter Control panel. Select circuit number d) Select CIR PUSH-BUTTON to display the numerical key picture e) Use the numerical key to enter the desired CIP circuit, see chapter Control panel. f) Select push-button to CONFIRM. If the confirmation is valid the selected circuit will be marked with X in the Circuit display Tetra Alcip 10 TPOP MINI 45

à Operation g) START AND CONFIRM the program with the Common function symbols Cleaning of package machine (optional) 1 If cleaning of packaging machines it is possible to select more than one CIP circuit. 2.2tf501610en.fm To reset a selection, select the circuit again Communication: 4 packaging machines; circuit numbers 9-14 Confirm the circuit selection, select cleaning program and start the cleaning as described above. 46 Tetra Alcip 10 TPOP MINI

Operation Initial start of stations programs 1 a) Display the STATION PROGRAM picture. Note! The initial start of station programs must be done from the station program picture. When this is done it is possible to stop and restart the station program from other menus. b) Select the PUSH-BUTTON that represent the desired station program and the display turns yellow. c) START AND CONFIRM the program with the Common function symbols 2.2tf501610en.fm Stepping of cleaning cycle 1 Select the MANUAL STEP followed by CONFIRM to step the cleaning cycle forward Note! Manual stepping can be done only when CIP is running and if valid acess code is entered. Tetra Alcip 10 TPOP MINI 47

Operation Drain of tank Drain of a tank can be done as long as there is no cleaning started. If the module is not equipped with by-pass valve; connect the circuit to a neutralizing unit, drain etc. Note! The initial start of station programs must be done from the station program picture. When this is done it is possible to stop and restart the station program from other menus. a) Select the PUSH-BUTTON for the desired station program. The button will change color. b) Select START push-button. c) Select CONFIRM START/STOP push-button. 2.2tf501610en.fm 48 Tetra Alcip 10 TPOP MINI

Cleaning Cleaning To achieve the best possible performance of the equipment it is essential to keep it clean and tidy. Clean the buffer tanks when changing cleaning solution: Do as follows: a) Perform a Drain of the tank, see section Operation. b) Fill a small amount of water. Use a rubber hose. c) Scrub the tank inside with a broom. d) Open the manual drain valves (V013 for lye and V012 for acid) to drain the tank. e) Flush the tank with water. Use a rubber hose, continue until no residues remains. f) Close the manual drain valves (V013 and V012). Clean the panel once a week with a cloth. Clean remaining equipment at regular intervals. 2.2 tf501314en.fm WARNING! Chemical hazard Cleaning solution contains caustic soda (NaOH) or nitric acid (HNO 3 ). This chemical may cause severe burning to skin and eyes. Use protective clothes, goggles and gloves during handling. If exposed - wash with water for at least 15 minutes. Seek medical assistance. Follow the instructions given by the supplier. Tetra Alcip 10 TPOP MINI 49

Cleaning This page intentionally left blank 2.2 tf501314en.fm 50 Tetra Alcip 10 TPOP MINI

Settings 2.2tf501315en.fm Inspection/change of parameter values 1 a) Display the PARAMETER EDIT PICTURE for the appropriate module. CAUTION! Change of values A change of value will change the machines way of working. This operation needs access code Note! For parameter list, see section Commissioning in Technical Manual (TeM). Tetra Alcip 10 TPOP MINI 51

Settings 1 step toggle 3 step toggle Next parameter number toggling up Next parameter number toggling down parameter number Change parameter number 2 a) Toggle the ARROWS until the right parameter number to inspect/change is displayed or select the P PUSH- BUTTON to display the numerical keys picture and enter the desired parameter number b) To change value continue according to Change parameter value 3 Change parameter value a) Select V PUSH-BUTTON to display the numerical keys picture b) Use the numerical key to enter the new parameter value see chapter Control panel. Note! If no value is given the old value is kept unchanged. 2.2tf501315en.fm 52 Tetra Alcip 10 TPOP MINI

Inspection/change of controllers 4 a) Display the CONTROLLER PICTURE. Settings Note! In the controller menu change of settings for test purpose is possible. When leaving the controller menu the settings are reset to values used when entering the menu. Final setting is selected in a parameter, see section Commissioning in Technical manual (TeM). 2.2tf501315en.fm 5 Change of gain, TI and setpoint a) Select the PUSH-BUTTON symbolizing desired controller b) Use the numerical key to enter new value see chapter Control panel. Tetra Alcip 10 TPOP MINI 53

Settings 6 Change of output a) Select MANUAL MODE PUSHBUTTON for turning the controller manually off b) Select MAN OUT PUSH-BUTTON to display the numerical keys picture c) Use the numerical key to enter the new output see chapter Control panel. a) Select AUTO MODE PUSHBUTTON for turning the controller manually on. 2.2tf501315en.fm 54 Tetra Alcip 10 TPOP MINI

Ref text to introduction