Installation and Operation Guide for PD4000 Series Power Control Center



Similar documents
Installation and Operation Guide for PD4100 Series Power Control Centers

Installation and Operation Guide PD4600 Series Converter Replacement

Installation/Operator Manual For use with WFCO ULTRA III Power Center Model WF-8712P and WF-8725P

Installation and Operation Guide for PD5100 Automatic Transfer Switch

Operator Manual For use with WFCO ULTRA III Distribution Center WF-8900 Series (model number located on the door assembly label)

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

AUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER

OWNER'S MANUAL. Model CUL AC Power Inverter/Charger System OM/A96283 REV. A

INSTALLATION & SERVICE MANUAL. Display Panel

User s Manual Before using the inverter, you need to read and save the safety instructions.

Instructions & Safety Information Models A220-20D and A220-20L Version 2

LESTRONIC DV AUTOMATIC 12 OR 24 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL TYPE 12/24EL40-10ET

Installation and Operating Instructions (for chargers shown below)

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

ELIXIR POWER CONVERTER / CHARGER

Mobile Data Power Model: MDP-25

3000W Power Inverter

Advantium 2 Plus Alarm

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System

User Manual for CH-PFC76810

XC120 XC180. Owner's Guide Conforms to / Conforme à UL std. 458, Toll Free

VLT Series 300 Watt True Sine Wave Inverter

DCX300 - DCX400 - DCX600

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Amps Per Bank. Total Output. Battery System. Model Name. 6 amps 12 amps 10 amps 20 amps 30 amps 40 amps 15 amps 30 amps 45 amps

12-Volt 10-Amp Regulated Power Supply

6 & 12 Volt Battery and Systems Tester with 100 Amp Load

HM-W536 Install Guide

Battery Power Inverters

MCR1900 Media Converter 19-Slot Chassis

REDI-LINE ELECTRIC GENERATORS USER'S GUIDE. Rugged, Reliable, DC to AC Power Conversion

Installation and Operating Instructions (for chargers shown below)

TROUBLESHOOTING GUIDE

NSI DDR DIMMING RACK POWER DISTRIBUTION UNIT

13 Watt PORTABLE SOLAR POWER KIT

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

INSTALLATION INSTRUCTIONS

POWER TO GET THE JOB DONE

OWNER S MANUAL. Model AE150/AE300/AE AMP MULTI-USE SMART BATTERY CHARGER READ ENTIRE MANUAL BEFORE USING THIS PRODUCT

12-Volt Negative Ground Installation Instructions

750 WATT Power Inverter

For Models #6-5001, #6-7501, # & #10-12K1

3 WATT LED SPOTLIGHT Model No. SLM

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Installation Instructions for Alarm Module Kit A043F059

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

VK-250 WARRANTY REGISTRATION FORM

12 Volt 30 Amp Digital Solar Charge Controller

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Instructional & Operating Manual

AUTOMATIC BEST BATTERY SELECTOR INSTALLATION & OPERATION BBS-1600 BBS-1600E

i410/i1010 AC/DC Current Clamp

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

Global Water Instrumentation, Inc.

PSC POWER STAR LiFE TM

AIM TECHNICAL MANUAL PATENT PENDING STOP REMEMBER TO ACTIVATE UNIT BEFORE TESTING. See page 9 for Activation Instructions

Alarm Clock USER GUIDE

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

Model HPX10 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

NSI DIGITAL DIMMING SYSTEM DDS 9800 DIMMER PACKS

Installation Instructions

Single Station Remote Alarm

INSTRUCTION MANUAL FOR RECREATIONAL REFRIGERATOR/FREEZER MODEL

INSTRUCTION MANUAL MODEL PCD-88

Nest Learning Thermostat Installation Guide. Installation step-by-step

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

User Manual. English. APC Smart-UPS SC. 1000/1500 VA 110/120/230 Vac. 2U Tower/Rack-Mount Uninterruptible Power Supply

Transfer Switch 30 Amps STS-30. Manual. Please read this manual before operating your transfer switch

Table of Contents TO OPERATE THE 12.0 VOLT POWER PACK: THIS OPERATES ONLY OFF THE UNIT S RECHARGEABLE BATTERY, NOT OFF YOUR VEHICLE S BATTERY.

APOLLO Gate Operators, Inc.

AIR CONDITIONER & HEAT PUMP DIGITAL CONTROL FOR DUCTED SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS

400 Amp Rechargeable Jump Start System RAC-HP082

STEALTH I DC MANUAL TECH SUPPORT WEB BLACK UNIT IS 24/36 ONLY

WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL

User Manual. English. APC Smart-UPS 500 VA 100 VAC 750 VA 100/120/230 VAC. Tower Uninterruptible Power Supply

PagePac PAGEPAL V

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

User Manual HomeGrid 3000 Solar Generator

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

Battery Tester. GxT Incorporated, Cheboygan MI, U.S.A. All Rights Reserved E040-01G. 40 & 42HD Operator s Manual

CHARGING SYSTEMS INTERNATIONAL

Mini-led spotlight with magnetic base

Model SRMD Setra Remote Monitoring Display

FW-X240 AUTO TRANSFORMER Installation Manual

OWNERS MANUAL FOR CORDLESS INFLATOR AIR260

How To Use A Cdm250 Digital Multimeter

BATTERY CHARGER RLD USER'S MANUAL

Seven function digital multimeter

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Comfort Control Relay Panel (CCRP)

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

16/32 Channel 1U Rack Mount CCTV Power Supply

4 in 1 Air Compressor

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

Transcription:

Extended warranties are available for purchase at www.progressivedyn.com Installation and Operation Guide for PD4000 Series Power Control Center Member Thank you for selecting Progressive Dynamics as your choice for your RV power needs. We d like to welcome you to a full line of industry leading and time tested products including our newest addition to the PDI family, the PD4000 Series POWER CONTROL CENTER. The PD4000 Series POWER CONTROL CENTER offers break-through technologies that help maintain and lengthen the life of your batteries such as our patented Charge Wizard. The heart of the PD4000 is the INTELI-POWER Converter. The built-in Charge Wizard microprocessor constantly monitors the battery voltage then automatically adjusts the converter output voltage to provide the proper charging voltage for fast recharges and long-term maintenance. The intelligent way to charge and maintain your RV battery. With enough AC and DC branches you ll have plenty of options for your growing RV needs. Progressive Dynamics, Inc. 507 Industrial Rd. Marshall, MI 49068 www.progressivedyn.com Patent Numbers: 5,687,066-5,600,550-5,982,643-6,184,649-7,782,002 2011 Progressive Dynamics, Inc. All rights reserved. 110145 Rev F

Table of Contents Installation Instructions 1 Wiring Diagram 1 Features and Operating Instructions 2 The Charge Wizard 2 Reverse Battery Protection 2 Technical Specs and Troubleshooting 3-4 LIMITED WARRANTY I. LIMITED WARRANTY: Progressive Dynamics, Inc. warrants its power control center to be free from defects in material or workmanship under normal use and service; and limits the remedies to repair or replacement. II. DURATION: This warranty shall extend for a period of two years from the original date of purchase, and is valid only within the continental limits of the United States and Canada. III. WARRANTY EXCLUSIONS: This warranty specifically does not apply to: A. Any product which has been repaired or altered in any way by an unauthorized person or service station; B. Damage caused by excessive input voltage, misuse, negligence or accident; or an external force; C. Any product which has been connected, installed or adjusted or used other than in accordance with the instructions furnished, or has had the serial number altered, defaced or removed; D. Cost of all services performed in removing and re-installing the power converter; and E. ANY LOST PROFITS, LOST SAVINGS, LOSS OF USE OF ENJOYMENT OR OTHER INCIDENTAL DAMAGES ARISING OUT OF THE USE OF, OR INABILITY TO USE, THE PRODUCT. THIS IN- CLUDES DAMAGES TO PROPERTY AND, TO THE EXTENT PERMITTED BY LAW, DAMAGES FOR PERSONAL INJURY. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IV. PROOF OF PURCHASE: A warranty claim must be accompanied by proof of the date of purchase. V. CLAIM PROCEDURE: Upon discovery of any defect, Progressive Dynamics, Inc. shall be supplied the following information at the address listed in this manual: A. Name and address of the claimant; B. Name and model of the product; C. Name, year and model of the recreational vehicle in which the product was installed; D. Date of purchase; and E. Complete description of the claimed defect. Upon determination that a warranty claim exists (a defect in material or workmanship occurring under normal use and service,) the converter section shall be shipped postage prepaid to Progressive Dynamics, Inc. together with proof of purchase. The product will be repaired or replaced and returned postage prepaid. For Warranty Service Call: (269) 781-4241 Progressive Dynamics, Inc.

Installation Instructions The PD4000 series POWER CONTROL CENTER should be installed horizontally (converter section to the left). Unit is NOT ignition protected. Do not mount in the LP gas or the battery compartment. Cut mounting hole to approximately 10 3/4 wide X 7 1/4 high. Connect wiring system using proper connections and appropriately sized cable clamp. A closure plug kit for any unused Romex connectors may be purchased from Progressive Dynamics, Inc. Part Number PD812374. For installations without an external DC disconnect switch connect battery POS (+) to the BATTERY POS. + lug. The ALTER- NATE BATTERY POS. + lug is not used. (see wiring diagram for lug locations) DC DISCONNECT: For installations incorporating an external DC disconnect switch, connect battery POS (+) and the BATTERY POS. + lug to the same pole on the external disconnect switch. Remove the JUMPER. Connect the ALTERNATE BATTERY POS. + to other pole on the external disconnect switch. (see wiring diagram for component locations) Page 1 The OEM should test the POWER CONTROL CENTER converter under full load conditions in its intended mounting location to ensure proper ventilation. Failure to provide adequate ventilation will prevent the converter from supplying full output power. The INTELI-POWER converters are not designed for zero clearance compartments. The POWER CONTROL CENTER was not designed for wet or damp locations. Install in an interior / dry location. The following breakers are suitable for MAIN and BRANCH breakers MAIN Branch Filler Plate ITE/Siemens QP,QT Thomas & Betts TB & TBBD Series ITE/Siemens QF3 Square D HOM, HOMT 30A 15A GE TQLFPI Cutler Hammer/Bryant BR,BRD Series BATTERY NEG. - GE HACR Detailed Wiring Diagram Note: Some factory installed wiring not shown for clarity. MAIN BREAKER HOLD DOWN MAIN BREAKER (NOT SUPPLIED) AC HOT IN (BLACK) BATTERY POS. + JUMPER ALTERNATE BATTERY POS. + (DC DISCONNECT) AC GROUND IN (GREEN) AC IN GROUND (GREEN) TO CONVERTER AC HOT (BLACK) TO CONVERTER AC NEUTRAL IN (WHITE) AC NEUTRAL (WHITE) TO CONVERTER Note: Above image may vary, depending on model. Consult a licensed electrician or an RV technician for installation assistance

User Information Page 2 Many options will be installed prior to the purchase of your new RV, however there are a few options that you should be aware of while operating your new POWER CONTROL CENTER. The PD4000 series incorporates a microprocessor to provide a three-stage charge profile to ensure rapid, yet safe recharging of 12 volt batteries. These three separate stages BOOST, NORMAL, and STORAGE modes ensure that the battery is automatically recharged and maintained with minimum maintenance (i.e. reduced need to add water). BOOST MODE: If the converter senses that the battery voltage has dropped below a preset level the output voltage is increased to approximately 14.4 volts DC to rapidly recharge the battery. NORMAL MODE: Output voltage set at approximately 13.6 volts DC. STORAGE MODE: When the converter senses that there has been no significant battery usage for 30 hours the output voltage is reduced to 13.2 volts DC for minimal water usage. When in storage mode the microprocessor automatically increases the output voltage to 14.4 volts DC for 15 minutes every 21 hours to help reduce sulfation of the battery plates. - All times and voltages provided above are approximate. - CAUTION IT IS IMPORTANT THAT THE FLUID LEVEL OF ANY CONNECTED BATTERIES BE CHECKED ON A REGULAR BASIS. ALL BATTERIES WILL GAS AND LOSE SOME FLUID WHEN CONTINUOUSLY CONNECTED TO ANY CHARGING SOURCE. ~Does not apply to gel-cell batteries~ CONVERTER OUTPUT VOLTAGE 14.8 14.4 14.2 14.0 13.8 13.6 13.4 13.2 13.0 12.8 12.6 12.4 0 BOOST MODE 14.4 VOLTS RAPIDLY BRINGS RV BATTERY UP TO 90% OF FULL CHARGE. NORMAL MODE 13.6 VOLTS SAFELY COMPLETES CHARGE EQUALIZE MODE 14.4 VOLTS EVERY 21 HOURS FOR A PERIOD OF 15 MINUTES TO PREVENT BATTERY STRATIFICATION. STORAGE MODE 13.2 VOLTS MAINTAINS CHARGE WITHOUT GASSING OR WATER LOSS 4 8 12 16 20 24 28 32 36 40 44 48 52 56 60 68 72 76 80 RECHARGE TIME IN HOURS REVERSE BATTERY PROTECTION CIRCUIT If a battery is accidentally hooked up backwards, the converter will be protected. Easily accessible ATC type fuses will blow when a battery is connected in reverse. Correct battery wiring and replace fuses with same type and rating. The LED will glow if one of the fuses blow. Appropriate fuse size is indicated on the circuit board. The DC Section: The DC panel features up to 12 fused positions rated for up to 30 amps for accessories. CAUTION FOR CONTINUED PROTECTION AGAINST RISK OF FIRE OR ELECTRICAL SHOCK, REPLACE ONLY WITH SAME TYPE AND RATING FUSE.

AC RATING COPPER WIRE ONLY. RATED 75 C MIN MAXIMUM SERVICE: 30 AMPS, 120V 50/60 HZ SINGLE PHASE LINE TERMINALS SIZE 6-14 AWG LOAD TERMINALS SIZE 6-14 AWG NEUTRAL AND GROUND SIZE 6-14 AWG SHORT CIRCUIT CURRENT RATING: SUITABLE FOR USE ON NO MORE THAN 120 VOLTS AC, 10,000 AMPERES MAX, LIMITED TO THE LOWEST INTERRUPTING CAPACITY OF ANY BREAKER INSTALLED NEUTRAL/GND WIRE COMBINATIONS: (1) #12 STRANDED & (1) #14 SOLID (1) #12 STRANDED & (1) #14 STRANDED (1) #12 SOLID & (1) #14 STRANDED (1) #12 SOLID & (1) #14 SOLID (2) #14 STRANDED OR (2) #14 SOLID (2) #12 STRANDED OR (2) #12 SOLID (2) #10 STRANDED OR (2) #10 SOLID MAXIMUM CONTINUOUS LOADS ON MAINS OR BRANCH CIRCUITS NOT TO EXCEED 80% OF THE CIRCUIT BREAKER RATINGS TORQUE DATA LINE TERMINAL: SEE CIRCUIT BREAKER NEUTRAL BAR & GROUND: #4 - #6 35 IN. LBS #8 30 IN. LBS #10 - #14 25 IN. LBS Page 3 Specifications (Specifications subject to change without notice) Model PD4045 PD4060 AC Section 120 VAC 30 Amps Maximum - 7 Branch Circuits Max * DC Section 12 VDC 60A Max. - 12 Branch Circuits 12 VDC 75A Max - 12 Branch Circuits Converter Section Input: 105-130 VAC 50/60 Hz 725 Watts Output: 13.6 VDC, 45 Amps Weight: 5.70 lbs * Consult local regulatory authority for possible branch circuit restrictions TROUBLE SHOOTING GUIDE Input: 105-130 VAC 50/60 Hz 1000 Watts Output: 13.6 VDC, 60 Amps Weight: 6.35 lbs PROBLEM POSSIBLE CAUSES ACTION No Output Low Output Intermittent or no Output on Generator, works on Shore Power Connect power supply 120 VAC supply not connected Check AC distribution panel for proper operation Reverse battery fuses blown Check for reverse battery connection. (See page 2 for location) Replace fuses with same type and rating (See page 2) Short circuit Trace RV circuits for possible fault Unit has shutdown due to overheating Unit has shutdown due to over voltage (Converter will shut down if the input voltage exceeds 132 VAC) Compartment gets too hot Excessive load for converter Input voltage not between 105-130 VAC Bad battery cell(s) Unit has shutdown due to over voltage. Check air flow Allow unit to cool Check input voltage Correct input voltage Check air flow to the converter Improve ventilation to the compartment Reduce load requirements or install larger converter Correct input supply voltage Replace battery Add another load to the generator, this may reduce the spikes to an acceptable level Some generators exhibit excessive voltage spikes on Contact generator manufacturer for possible defect in the generator the AC power output, this may cause the over voltage protection to shut the unit down Consult a licensed electrician or an RV technician for installation assistance

Page 4 Do not replace the converter section unless the following checks have been performed: 1. Use an AC voltmeter to check for the proper voltage at the 120 VAC breaker that the converter is connected to. This voltage should be between 105 and 130 volts. 2. Remove the reverse battery fuses and check the converter output from the CONVERTER GND to the CONVERTER POS terminals on the DC board. This should be 13.6 VDC. 3. Check the Reverse Battery fuses. These fuses will only blow if the battery or DC output leads were connected in reverse, even for a moment. If they are blown check the polarity of the battery connections before replacing them. 4. If the Converter output is not present and there is AC to the converter, the converter is defective. Disconnect converter wires from DC board. Remove screw that secures metal plate to housing. If you should need to replace the power converter for any reason, follow these steps to safely remove the converter section. Disconnect converter wires from AC hot, NEU, and GND bar connections. Make sure all power is disconnected before proceeding. 1. Remove the neutral, ground, and hot wires that lead to the converter on the AC side. 2. Remove the converter output wires from the DC board, ground and positive. 3. Finally unscrew the screw that holds the metal converter plate to the plastic housing. For factory repairs, return only the converter section. Make sure you use proper packaging to ensure the product s safe arrival.

Notes:

Progressive Dynamics, Inc. 507 Industrial Rd Marshall MI 49068 Visit us on the web for other great products. www.progressivedyn.com