HND-R. Hand-held ph, Redox and Temperature Measuring Units



Similar documents
ELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately:

Compact ph Measuring Instruments

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor

SenTix 950 SenTix 980

Agilent 4338B Milliohm Meter

Agilent 4339B/4349B High Resistance Meters

World Consumer Income and Expenditure Patterns

OSRAM LEDs take downlights into the future. LEDVANCE DOWNLIGHT and PARATHOM KIT LED PRO.

To install the I/O Module Board: 1. Remove AC power from decoder.

DISSOLVED OXYGEN METER Model : DO-5509

Make the invisible visible! SENSORS WITH EXCELLENT BACKGROUND SUPPRESSION

Accuracy counts! SENSORS WITH ANALOG OUTPUT

FACT SHEET Global Direct Selling

NITROGEN CHARGING KIT type PCM 11.2 E 04-11

OXIGENO DISUELTO. Dissolved Oxygen. Install & forget. Sistema autolimpiable. Autoclean system

Appendix 1: Full Country Rankings

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

JUMO tecline HD ph and JUMO tecline HD Rd

Foreign Taxes Paid and Foreign Source Income INTECH Global Income Managed Volatility Fund

Handheld portable appliance testers

Resolution selectable from 0.01 and ph. Range ph. Accuracy ± ph

Agilent 87421A/87422A Power Supply

Duct Humidity Transmitter

MERCER S COMPENSATION ANALYSIS AND REVIEW SYSTEM AN ONLINE TOOL DESIGNED TO TAKE THE WORK OUT OF YOUR COMPENSATION REVIEW PROCESS

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

ph 200 ph-/redox-/temperature Meter Operating instructions

Overview menu: ArminLabs - DHL Medical Express Online-Pickup: Access to the Online System

41 T Korea, Rep T Netherlands T Japan E Bulgaria T Argentina T Czech Republic T Greece 50.

ExStik TM ph Waterproof Meters

BSN Description. 2. Features. 3. Applications. 4. Pinning information. N-channel enhancement mode field-effect transistor

GE Grid Solutions. Providing solutions that keep the world energized Press Conference Call Presentation November 12, Imagination at work.

Hand-held thermometer Model CTH7000

The big pay turnaround: Eurozone recovering, emerging markets falter in 2015

Instruction Manual HI Portable Waterproof Microprocessor Dissolved Oxygen Meter

DPST-ELMETRON-meters. Contents: ELMETRON 100 series pocket instruments. ELMETRON 411 series portable meters. ELMETRON 401 series portable meters

Incubator with mechanical convection

NI USB-6008/6009 OEM USER GUIDE

BT Premium Event Call and Web Rate Card

Triple-play subscriptions to rocket to 400 mil.

GLOBAL DATA CENTER INVESTMENT 2013

1.5 GHz Active Probe TAP1500 Datasheet

Logix5000 Clock Update Tool V /13/2005 Copyright 2005 Rockwell Automation Inc., All Rights Reserved. 1

Cisco 2-Port OC-3/STM-1 Packet-over-SONET Port Adapter

Sulfuric Acid 2013 World Market Outlook and Forecast up to 2017

Quick Connect. quick - simple - efficient.

Portable digital microprocessor thermometers with interchangeable probes

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Motion Graphic Design Census. 10 hrs. motiongraphicdesigncensus.org. 9 hrs.

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

DSV Air & Sea, Inc. Aerospace Sector. DSV Air & Sea, Inc. Aerospace

Reporting practices for domestic and total debt securities

Bar code scanners CLV45x / CLV450 / Standard Density

Measurement data monitoring system

Cisco Conference Connection

Temperature Transmitters ZTT series

THE ETHICS HELPLINE Worldwide Dialing Instructions April 2012

GfK PURCHASING POWER INTERNATIONAL

Senate Committee: Education and Employment. QUESTION ON NOTICE Budget Estimates

Speed sensor MiniCoder GEL 247

STATISTICS FOR THE FURNITURE INDUSTRY AND TRADE

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

High-voltage Differential Probes TMDP THDP THDP P5200A - P5202A - P5205A - P5210A

Global Effective Tax Rates

Temperature Sensors. Accessories. for Injection Molding. Types 6192B, 6193B,

Global Economic Briefing: Global Inflation

Material test chamber with mechanical convection

Table 1: TSQM Version 1.4 Available Translations

USB-500 Series Stand-Alone, Low-Cost Data Loggers

SCHATZ - TEST Tool testing systems. SCHATZ -certest-w. Dynamic testing of torque tools

ph/redox Measurement MyPro CPM 431

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

TS8000. Profibus DP Option 8000/PB/00 HA Issue 1

How To Get A New Phone System For Your Business

Digital TV Research. Research-v3873/ Publisher Sample

Bar code scanners CLX49x / CLX490 / Standard Density

MAUVE GROUP GLOBAL EMPLOYMENT SOLUTIONS PORTFOLIO

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

PAT120, PAT150 and PAT150R Handheld portable appliance testers

Application Note. USD 2995 (a) High Throughput Regeneration Study on MEP HyperCel Mixed-Mode Sorbent on ScreenExpert RoboColumns u

Brochure More information from

Physical Specifications (Custom design available.)

USB-500 Series Low-Cost Data Loggers and Accessories

Milwaukee USER MANUAL

Compact Water Quality Meter B-700 series

Stainless Steel Dissolved Oxygen Electrodes

Customer Support. Superior Service Solutions for Your Laser and Laser Accessories. Superior Reliability & Performance

R&S SMZ Frequency Multiplier Precise output levels from 50 GHz to 170 GHz

Global AML Resource Map Over 2000 AML professionals

IOOF QuantPlus. International Equities Portfolio NZD. Quarterly update

NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES

CISCO AIRONET POWER INJECTOR

Image Lab Software How to Obtain Stain-Free Gel and Blot Images. Instructions

QuickSpecs. HP Wireless Keyboard and Mouse. Models

Turbine Flow Sensor Series VTR

THE CISCO CRM COMMUNICATIONS CONNECTOR GIVES EMPLOYEES SECURE, RELIABLE, AND CONVENIENT ACCESS TO CUSTOMER INFORMATION

Know the Facts. Aon Hewitt Country Profiles can help: Support a decision to establish or not establish operations in a specific country.

UltraBasic Benchtop ph Meter Operation Manual

SUPPLEMENTAL EXECUTIVE RETIREMENT PLANS IN CANADA

Transcription:

Hand-held ph, Redo and Temperature Measuring Units measuring monitoring analysing HND-R A1 P? OMeasuring O range: ph: 0.00...14.00 Redo (ORP): -1999 mv... +2000 mv Temperature: -5 C...+150 C rh: 0.0 rh... 70.0 rh OMeasuring O accuracy: ±0.01 ph / ±0.1% FS (mv) / ±0.2 C / ±0.1 rh OSerial O interface, minimum/maimum memory, hold function, auto-off, automatic temperature compensation O O Robust housing, IP 65, front KOBOLD companies worldwide: ARGENTINA, AUSTRALIA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHILE, CHINA, COLoMBIA, CZECHIA, EGYPT, FRANCE, GERMANY, GREAT BRITAIN, HUNGARY, INDIA, INDONESIA, ITALY, MALAYSIA, MEXICO, NETHERLANDS, PERU, POLAND, Republic of Korea, ROMANIA, SINGAPORE, SPAIN, SWITZERLAND, TAIWAN, THAILAND, TUNISIA, turkey, USA, VIETNAM KOBOLD Messring GmbH Nordring 22-24 D-65719 Hofheim/Ts. Head Office: +49(0)6192 299-0 +49(0)6192 23398 info.de@kobold.com 1

Hand-Held ph, Redo and Temperature Measuring Units Model HND-R Description The KOBOLD hand-held ph, Redo and temperature measuring units of the HND-R106 model are compact and universally applicable measuring units for electrodes with BNC plug connection. An etensive selection of electrodes makes it possible to use the HND-R106 in almost all application areas. The KOBOLD HND-R106 measuring unit offers functions like minimum/maimum value memory, hold function, auto off function and automatic temperature compensation. In addition to ph, Redo and temperature measurement, the device can display the relative humidity value. This is calculated from the measured Redo-value and the previously measured or manually entered ph-value. Areas of application OOChemistry, pharmacy OOWastewater treatment OOLaboratory application Technical Details (The data listed refers to the measuring unit without consideration for the respective electrodes) Measurement input: for ph and Redo electrodes with BNC plug connection Measuring range: ph: Redo (ORP): for Pt 1000 / 2 4 mm banana socket (measuring unit) 0.00...14.00 ph -1999...+2000 mv Temperature: -5...+150 C or 23...+302 F rh: Accuracy: ph: Redo (ORP): Temperature: rh: Display: Operating temp.: 0.0... 70.0 rh (measuring unit) (±1 digit, at nominal temp. 25 C) ±0.01 ph ±0.1% FS (mv) ±0,2 C (-20... +80 C), otherwise ±0.4 C ±0.1 rh two 4-digit LCD 0... +50 C (housing) Storage temperature: -20... +70 C Storage humidity: Electrode: Output: Power supply: 0... +95% rh (non-condensing) see technical data ph-, Redo probe for HND-R serial interface (via 3-pin jack, transformer on RS232 or USB optional) 9 V-monobloc battery (included in the scope of delivery), eternal 10.5-12 V DC via jack Material: housing made of impact-resistant ABS plastic Protection: IP 65, front Dimensions: 142 71 26 mm (H W D) Weight: appro. 165 g Scope of functions OOMinimum/maimum value memory OOHold-function:»freezing«of the current value OOAutomatic-off function: 1...120 min (can be deactivated) O O Automatic temperature compensation with connected temperature probes (manually: without connected temperature probes) OOReplace battery display Order Details Order no. HND-R 106 Housing design ph and Redo with BNCelectrode connection, temperature with 2 4 mm banana socket 2

Hand-Held ph, Redo and Temperature Measuring Units Model HND-R ph-electrodes for HND-R HND-RF02 HND-RF03 HND-RF06 HND-RF11 HND-RF15 HND-RF17 Measuring range 0... 14 ph 2... 11 ph 0... 14 ph 0... 14 ph 2... 14 ph 0... 14 ph 0... 80 C 0... 60 C 0... 80 C 0... 60 C 0... 80 C 0... 80 C Conductivity >100 μs / cm >100 μs / cm >100 μs / cm >200 μs / cm >20 μs / cm >100 μs / cm Temperature sensor no no no no no integr. Pt1000 4 mm banana Water-proof no no no no no no Pressure resistant no no 6 bar no no 6 bar Cable 1 m 1 m 2 m 1 m 1 m 2 m Electrolyte 3 mol/l KCl 3 mol/l KCl gel electrolyte gel electrolyte 3 mol/l KCl gel electrolyte Diaphragm 2 ceramic 2 ceramic 2 ceramic 1 Pellon moving joint 2 ceramic Thread without without PG 13,5 without without PG 13.5 Electrode shank Features Tyril, Ø12 mm low-cost, universal electrode glass, Ø12 bzw. 6 mm tip Ø 6 mm, small sample volume PSU, Ø12 mm low maintenance epoy, Ø12 mm low-cost, low maintenance glass, Ø12 mm for low-ion media PSU, Ø12 mm temperature compensated HND-RF10 Electrode type Supplementary set consisting of: HND-RF02, HND-TF07* (Pt1000), HND-Z023 and HND-Z076 * HND-TF07: Pt 1000 temperature immersion sensor for liquids, 1m PVC cable with two banana plugs Diaphragm The diaphragm makes the electric connection between reference system and sample. Additionally it should prevent the spoiling of the reference electrolyte by the measured medium. Ceramic diaphragm Several porous ceramic rods are mounted. Application: general applications in clean till lightly soiled media Joint / movable joint The roughened surface between the cut glass of the electrode and a cut glass sleeve permits a electrolyte flow of several ml/h. Application: low-ion or heavily soiled samples Pellon diaphragm A pellon mesh is introduced. A fast response and stable readings are possible through the permeable diaphragm. Application: from clean to slightly dirty media Reference electrolyte The reference electrolyte offers a constant voltage of the reference system and makes the electrical connection between sample and reference electrode. Liquid electrolyte Mainly 3 mol/l KCl is used. Liquid electrolytes offer fast response times in general and can be replaced if contaminated. Gel electrolyte The electrolyte is solidified for low-maintenance electrodes able to measure irrespective to its position. Under normal measurement conditions no noticeable electrolyte leakage is observable. 1/04-2015 3

Hand-Held ph, Redo and Temperature Measuring Units Model HND-R Application areas for ph electrodes Application HND-RF02 HND-RF03 HND-RF08 HND-RF11 HND-RF15 HND-RF17 Aquarium water Soil testing Emulsions On-site measurements Fish farming Low-ion media Cosmetics Food samples Sea water Swimming pool water Suspensions Drinking water Water-based lacquers Redo-electrode for HND-R HND-RF08 Electrode type Redo-electrode, ± 2000 mv, 0-80 C, > 25 μs/cm, incl. 100 ml Redo testing solution, 3 mol/l KCL, refillable 4

Hand-Held ph, Redo and Temperature Measuring Units Model HND-R Accessories for ph-, Redo and temperature measuring units HND-R and HND-RF electrodes HND-Z002 HND-Z012 HND-Z021* HND-Z022* HND-Z023* HND-Z031 HND-Z032 HND-Z033 BUS-S20M HND-Z071 HND-Z072 HND-Z073 HND-Z074 HND-Z075 Description Plug power supply unit (220/240 V AC, 50/60 Hz), 10,5 V DC /10 ma Protective housing bag, nappa leather, 2 with cut-outs for round sensor connections Case with recess (275 229 83 mm) Universal case with egg crate foam (275 229 83 mm) Large case with recess (394 294 106 mm) Interface converter on RS 232, galvanically isolated Interface converter on USB, galvanically isolated Adapter RS 232-converter on USB-interface Software for recording measurement data on a computer, for instruments of the HND-series without logger function 3 mol /l KCl-electrolyte for refilling or storing electrodes, 100 ml wash bottle 1 mol /l KNO3-electrolyte, 100 ml wash bottle 100 ml Pepsin cleaning solution 100 ml Redo testing solution (220 mv at 25 C) 100 ml plastic wide mouth bottle HND-Z076 Work and calibration set, consisting of 5 buffer capsules each ph 4, ph 7, ph 10, 3 HND-Z075, 1 HND-Z071, 1 HND-Z073 * Observe instrument dimensions Additional accessories upon request 1/04-2015 5