Domestic Refrigerators for Vaccine Storage in Tunisia



Similar documents
OBJECTIVE: To provide safe storage and handling for vaccines and medications that require refrigeration.

VACCINE CARRIERS AND COLD BOXES

Assessment of a remote alarm system for vaccine storage in Albania

New York State Department of Health (NYSDOH) Bureau of Immunization Vaccine Storage and Handling Plan

WHO PQS Prequalification System

Facility Name. Day of Month

Breakeven Analysis for Various Human Papillomavirus Vaccine Presentations in Vietnam and Uganda

Facility Name. Day of Month

VFC. Vaccine Management Guide. Vaccines for children. Chicago Department of Public Health

Cold Chain Shipping: Protecting Temperature Sensitive Products. Diane McLean Pfizer Global Manufacturing

11 MEDICATION MANAGEMENT

HSE Guidelines for maintaining the vaccine cold-chain including maintenance of vaccine fridges and management of vaccines

(WHO Technical Report Series, No. 961, 2011), Annex 9. Temperature and humidity monitoring systems for fixed storage areas 107

SECTION 7 STORAGE AND HANDLING OF IMMUNIZATION AGENTS

Best-Practice Guide Pharmaceutical-Chain Temperature Control and Recording

Thermo Scientific Guide for Vaccine Storage. Four steps for. safe and secure vaccine storage

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

Protocol for ordering, storing and handling vaccines. March 2014

Measuring equipment in a laboratory.

A Stability Program for the Distribution of Drug Products

SOP: Prepare Cold Chain (2-8 C) shipment of clinical samples in tropical settings.

Data Logger Basics For VFC Providers. Montana Immunization Program

Immunization Healthcare Branch. Storage & Handling Questions and Answers. Prepared by. Immunization Healthcare Branch (IHB), Defense Health Agency

Qualification of temperature-controlled storage areas

VFC Program Requirements for 2015

Guidelines for Storage and Temperature Monitoring of Refrigerated Vaccines

Temperature mapping of storage areas

Vaccine regional distribution center cost assessment

Frequently Asked Questions. Isotherm Fridge & Freezers

Variable Capacity Compressors, a new dimension for refrigeration engineers to explore

Transport Boxes (active & passive systems)

How to choose a heat pump and use it wisely

MT I Transport Boxes (Active & Passive)

The Cold Chain and Vaccine storage

Vaccine Storage Practices Appropriate Vaccine and Diluent Storage Conditions

IC+ NEW inverter compressor technology delivers energy saving, high performance cooling

A fridge that takes only 0.1 kwh a day?

UNICEF s Quality Assurance System for procurement of medicines

THE PREPARATION OF SINGLE DONOR CRYOPRECIPITATE

Key energy-efficient features of your new home

Smallpox Vaccine Logistics: Distribution, Storage, and Security

SIBIR MANUAL V110 KE. English page 5 RKE - 1D

Program Manual Policy & Practice Standards Manual

Seventh Avenue Inc. 1

CHAPTER 7 THE SECOND LAW OF THERMODYNAMICS. Blank

An Assessment of Vaccine Supply Chain and Logistics Systems in Thailand

Healthcare Logistics. Delivered by

Bring the fresh in. Dedicated Outside Air Systems

Dienstleistung. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses

INSTRUCTION MANUAL FOR RECREATIONAL REFRIGERATOR/FREEZER MODEL

Care and Monitoring of Refrigerators and Freezers

HOW TO USE PASSIVE CONTAINERS AND COOLANT-PACKS FOR VACCINE TRANSPORT AND OUTREACH OPERATIONS

Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now

Heat Pump Training System

RESEARCH HIGHLIGHT. The Impact of Heat Pump Water Heaters on Whole-House Energy Consumption

INTRODUCTION. Viral shedding is crucial for Gene Therapy Products Safety linked with shedding data

Heat Recovery from Data Centres Conference Designing Energy Efficient Data Centres

Page 2 of Routine Monitoring Daily (For C135 and MB B-46 only)

Operating Procedures of the PAHO Revolving Fund. for the Purchase of Vaccines, Syringes, and Other Related Supplies

Clean & Clever Energy Toolkits Hot Water System

Temperature mapping of storage areas Technical supplement to WHO Technical Report Series, No. 961, 2011

S IJDERS SCIE TIFIC B.V.

Appendix 2: Example Validation Plan

Around the Corner or Around the World

Freezers - Ultrafreezers. Platilab & Irilab Series

Sample DTE Energy Rebate Programs Follow:

How do I set up the requirements?

Temperature and humidity monitoring systems for fixed storage areas

LIBERO: Innovation Leader in Cold Chain Monitoring

Intelligent control system with integrated electronic expansion valves in an air-conditioning system operating at a Telecom telephone exchange

How to choose a heat pump and use it wisely

Energy Saving Tips. Adjust set point temperature up a few degrees... Window contact. Occupancy sensor. A Programmable Thermostat

User Guide. rev. 08/11. RENTAL SALES SERVICE LOGISTICS Toll free number:

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

Temperature and humidity monitoring systems for fixed storage areas

SAFETY PRECAUTIONS Read all of the instructions before using this appliance. When using this appliance, always exercise basic safely precautions,

BIOMEDICAL REFRIGERATORS

DNA Ladders shipped at ambient temperature reduce environmental impact and retain their quality and stability

The ebike Rechargeable Battery Guide

Professional Kitchens

Understanding Energy Use, Taking Steps to Reduce Energy Use (Intermediate/Advanced ESOL level)

Air-Conditioning Buying Guide

Saving energy in your business

[4] SA1.2 The student demonstrates an understanding of the processes of science by observing,

REPUBLIC OF KENYA MINISTRY OF FOREIGN AFFAIRS AND INTERNATIONAL TRADE PRE-QUALIFICATION/REGISTRATION OF SUPPLIERS FY /

Natural gas heating versus split system heating and the current and future viability of the Natural gas network

Optimization of combined heating and cooling in Supermarkets

Split units TH with hermetic compressors

Draft UCL Heating, Cooling and Ventilation Policy

Why and How we Use Capacity Control

Passiv Haus Institut. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses

Step 3: Vaccine Handling and Storage

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Transcription:

Domestic Refrigerators for Vaccine Storage in Tunisia Conclusion and recommendations October 2012 Batiment Avant Centre 13 Chemin du Levant 01210 Ferney Voltaire France Phone: 33.450.28.00.49 Fax: 33.450.28.04.07 www.path.org www.who.int

This report was commissioned by Optimize: Immunization Systems and Technologies for Tomorrow, a World Health Organization (WHO) and PATH collaboration. The report was authored by John Lloyd and Steve McCarney, consultants; and Dr. Ramzi Ouhichi, WHO. Contact information: Joanie Robertson Manager jrobertson@path.org Mail PO Box 900922 Seattle, WA 98109 USA Street 2201 Westlake Avenue, Suite 200 Seattle, WA 98121 USA www.path.org Suggested citation: PATH, WHO. Domestic Refrigerators for Vaccine Storage in Tunisia: Conclusion and Recommendations. Seattle: PATH, WHO; 2012. This work was funded in whole or part by a grant from the Bill & Melinda Gates Foundation. The views expressed herein are solely those of the authors and do not necessarily reflect the views of the Foundation. Copyright 2012, Program for Appropriate Technology in Health (PATH), World Health Organization (WHO). All rights reserved. The material in this document may be freely used for educational or noncommercial purposes, provided that the material is accompanied by an acknowledgment. ii

Domestic Refrigerators for Vaccine Storage in Tunisia Conclusion and recommendations October 2012 iii

Table of contents Executive summary... vi Background... 1 Objectives of testing... 2 Selection of refrigerator models... 2 Test program at CETIME, Tunis... 2 Phase 1 testing... 3 Phase 2 testing... 4 Conclusion on laboratory testing... 5 Field monitoring in the Kasserine Region... 6 Discussion and recommendations... 7 iv

Acronyms CETIME DSSB EPI PATH PQS WHO Centre Technique des Industries Mécaniques et Electriques Direction des Soins de Santé de Base Expanded Programme on Immunization Program for Appropriate Technology in Health Performance, Quality and Safety World Health Organization v

Executive summary Today, the Tunisian government does not classify refrigerators from the domestic market that are procured and used to store vaccines as medical equipment, and their performance is not controlled. This document summarizes a laboratory report on performance testing of four models of domestic refrigerators that are available on the Tunisian market to assess their suitability for storage of vaccines. Project Optimize contracted the tests to demonstrate to the government the importance of prequalification of models according to World Health Organization (WHO)/Quality, Safety and Standards norms for the storage of vaccines and to provide appropriate recommendations. The testing revealed a number of weaknesses in the performance of all models in ambient test temperatures of 32 C and 43 C, which call for close monitoring of temperatures in the field. The refrigerator model BOSCH KDN36X03/04 performed the best of the four models tested and is therefore closest to meeting WHO requirements. To minimize the risk of using refrigerators from the domestic market, project Optimize recommends the following policies and practices: Reclassify refrigerators intended for vaccine storage as medical equipment that should meet international or national norms of performance. Require that models be prequalified in an independent laboratory according to these norms before countries and partners procure them. Require that health workers use a wall of water-filled packs to surround the vaccines within the refrigerators to protect them from temperature fluctuations. Require that health workers follow the standard refrigerator operating procedures. Require that health workers use 30-day temperature recorders that meet WHO norms (E006/TR06.3) to monitor the temperatures in all refrigerators used to store vaccines and that sufficient training is provided for this purpose. vi

Background Refrigerators that are used to store vaccines are required by the World Health Organization (WHO) to meet certain performance standards so that the conditions of storage are maintained even in the extremes of ambient temperature in areas where they are used. In many areas of Tunisia, including the region of Kasserine, the ambient temperature in summer can reach 43 C (see Figure 1), and the temperatures in winter can drop toward 0 C, even within store buildings. Therefore, it is important that vaccines are protected against high temperatures and freezing temperatures, and that storage temperatures are maintained during power cuts. Figure 1. Annual range of ambient temperatures in the region of Kasserine. The Tunisian government does not verify the performance of refrigerators used for vaccine storage because they are not classified as medical equipment. Instead, domestic refrigerators designed to store food in temperate climates are used in the majority of district stores and health centers to store vaccines. In early 2010, the project team logged temperatures in ten refrigerators over 82 days. The results revealed problems including both freezing temperatures and high temperatures placing vaccine at risk. The Tunisian Ministry of Health is aware of these problems and in recent years has tried to interest local suppliers of refrigerators to adapt a model to meet the needs of vaccine storage. This initiative has been blocked to date by the small scale of the vaccine cold chain market in Tunisia (approximately100 units per year) and the unwillingness of parent international corporations to license deviations from the standard domestic models. The refrigerator testing reviewed in this report is part of a broader demonstration of improvements to the vaccine supply chain in Tunisia by project Optimize. Project Optimize and the Tunisian Ministry of Public Health are collaborating to explore new logistics and supply chain solutions that can optimize the vaccine supply chain. The project aims to establish a high-efficiency cold chain from Tunis to the point of vaccine administration. The effectiveness of the vaccine cold chain depends on refrigerators functioning correctly so that they can maintain a constant 2 C to 8 C, the required temperature range for vaccines.

Objectives of testing Considering the risks of using domestic refrigerators for vaccine storage, the project Optimize team decided to safeguard the quality of the Tunisian cold chain from Tunis, through Sousse, to the region of Kasserine. In order to accomplish this, the project: Established a system of 30-day recording of temperatures in every refrigerator and a system of monthly supervision supported by temperature compliance reports of all refrigerators by area. Conducted performance testing in the laboratory on a selection of preferred models of refrigerators for this purpose available in the Tunisian market. In this way the project sought to identify and replace dysfunctional refrigerators with new refrigerators whose performance had been verified by laboratory tests to WHO Performance, Quality and Safety (PQS) norms. Selection of refrigerator models The Ministry (DSSB) selected four models (see Table 1) for testing from those available in the Tunisian market. The models were selected on the basis of the following criteria: Purchase cost between 700 and 1000 dinars. Capacity usable for vaccines. Energy rating (class 1, 2, or 3). Table 1. Refrigerator models selected for testing against WHO norms. Manufacturer Model Energy rating (kwh/year) Volume of refrigerator (liters) Volume of freezer (liters) Cost (Dinars) Remarks LG GN392 3 (468) 260 61 900 Thermometer, auto-defrost Bosch NKD 36 X 03 2 (383) 257 78 1000 Samsung RT45MASW 3 (408) 266 78 949 Auto-defrost Electrolux ERD24001W 2 (363) 186 44 900 kwh = kilowatt hour. Test program at CETIME, Tunis Testing was conducted at the Laboratories of the Centre Technique des Industries Mécaniques et Electriques (CETIME), the Tunisian state refrigeration testing facility in Tunis. This was done according to selected test procedures of WHO/PQS (see Table 2) in two phases: 1. Testing at 27 C and 32 C ambient temperature. 2

2. Testing at 43 C ambient temperature. Table 2. Test phases by PQS and ambient temperature. PQS test number Ambient temperature Test descriptions 27 C and 32 C Tests included cool-down, stable 1 WHO/PQS/ RFO1-VP.2 i running, ice pack freeze capacity, holdover time, and day/night cycle tests. 43 C Tests included stable running, 2 WHO/PQS/ RFO1-VP.2 ii holdover time, and day/night cycle tests. Phase 1 testing Of the models tested, none of the models passed all the tests, and all models failed the holdover test. One model, BOSCH KDN36X03/04, passed all of the tests at 32 C except the holdover test. Based on the results at 27 C and 32 C ambient temperatures, the project team decided that only two models, BOSCH KDN36X03/04 and ELECTROLUX ERD24001W, would be tested at 43 C in Phase 2. Table 3. Comparative performance at 27 C and 32 C against test pass criteria. Models Tests Results at 27 C BOSCH KDN36X03/04 Results at 32 C Between 3.3 C Pass criteria Cool-down test empty Between 2.2 C and 8.3 C and 7.3 C Stable running test Between 3.3 C Between 3 C and 10.5 C and 7.3 C Ice-pack freezing rate 16.675 kg 16.675 kg 2.4 kg/24 hours ELECTROLUX ERD24001W Holdover test 43 minutes 50 minutes Greater than 4 hours at less than 10 C within the vaccine load Day/night test: 32 C/15 C and 27 C/10 C Between 2.8 C and 10.8 C Between 3 C and 7.3 C Cool-down test empty Between 2.3 C Between 3 C and 7.4 C and 9.1 C Stable running test Between 2.8 C Between 4.2 C and 7.9 C and 9.4 C Ice-pack freezing rate 13 kg 13 kg 2.4 kg/24 hours i Essais de performances des réfrigérateurs congélateurs combinés selon le protocole d essai de type indépendent PQS à 32C ; Rapport IAT 103/2012 Project A3031202. ii Essais de performances des réfrigérateurs congélateurs combinés selon le protocole d essai de type indépendent PQS à 32C ; Rapport: IAT 456-b /2010 Project A30310137. 3

Models Tests Results at Results at Pass criteria 27 C 32 C Holdover test 34 minutes 44 minutes Greater than 4 hours at less than 10 C within the vaccine load LG GN392 Day/night test: 32 C/15 C and 27 C/10 C Between 1.85 C and 7.88 C Between 4.4 C and 9.3 C Cool-down test empty -3.5 C -1.6 C Stable running test -3.5 C -1.2 C Ice-pack freezing rate 17.4 kg 17.4 kg 2.4 kg/24 hours SAMSUNG RT45MASW Holdover test 99 minutes 80 minutes Greater than 4 hours at less than 10 C within the vaccine load Day/night test: 32 C/15 C and 27 C/10 C Cool-down test empty -3.9 C -1 C Between 0.9 C and 7.4 C Between 4.13 C and 9.4 C Between 2.8 C and 9.1 C Stable running test Between 3.1 C and 7.7 C Ice-pack freezing rate 17.4 kg 17.4 kg 2.4 kg/24 hours Holdover test 64 minutes 64 minutes Greater than 4 hours at less than 10 C within the vaccine load Day/night test: 32 C/15 C and 27 C/10 C Pass Fail and 7.5 C Between 2.5 C and 8.9 C Phase 2 testing The project team modified the test procedures for Phase 2 to conduct the tests two times to evaluate the stabilizing effect of adding mass surrounding the vaccine load. The team reasoned that considering the performance results at 32 C, the extra stability would be important at 43 C. Therefore, the laboratory conducted two test cycles: 1. With a dummy vaccine load only, as specified in WHO procedure. 2. With a dummy vaccine load and with a wall of water-filled packs surrounding the vaccine, or with a wall of water-filled packs surrounding the vaccine. 4

Neither model passed all criteria for 43 C testing. Test data showed marginal improvements in performance in cycle 2 of the testing compared to cycle 1. The performance of the two models was similar, but the Bosch passed the day/night test and only marginally failed the stable running test (1.1 C above the limit) in cycle 2. Table 4. Comparative performance at 43 C ambient against test pass criteria. Models Tests Results Pass criteria BOSCH KDN36X03/04 Holdover test with waterfilled packs Holdover test with vaccine only 3 hours 42 minutes Greater than 4 hours at less than 10 C within the vaccine load 43 C/25 C day/night test with water-filled packs 43 C/25 C day/night test with vaccine only 2.4 C/9.1 C min/max Between 3.7 C and 12.7 C Stable running with waterfilled packs Stable running with vaccine only Between 2.4 C and 9.1 C Between 3.7 C and 12.7 C ELECTROLUX ERD24001W Holdover test with waterfilled packs Holdover test with vaccine only 13 minutes 0 minutes Greater than 4 hours at less than 10 C 43 C/25 C day/night test with water-filled packs 43 C/25 C day/night test with vaccine only Between -5.5 C and 9 C Between -8.5 C and 8.3 C Stable running with waterfilled packs Between 5.8 C and 11.1 C Stable running with vaccine only Between 4.3 C and 8.8 C Note: 43 C/25 C The / indicates the day/night temperature profile of this test. Fail Pass Conclusion on laboratory testing Although all four models failed one or more tests at the two test temperatures, the performance of two models in Phase 2 was improved by adding a wall of water-filled packs surrounding the vaccine load (see Figure 2). 5

Figure 2. Arrangement of water-filled packs in refrigerator. Photo: WHO/Dr. Ramzi Ouhichi, Tunisia 2012 Although neither refrigerator succeeded in passing the holdover test, there was a marked performance improvement associated with packs filled with water. The team recommends that, of the two options, the water-filled packs will protect best against accidental freezing of vaccine that has occurred frequently in the project facilities following a power cut. Overall, one model, BOSCH KDN36X03/04, performed best in the Phase 1 and 2 testing and came closest to meeting WHO norms. Field monitoring in the Kasserine Region Temperature records on vaccine storage are now available from all facilities included in the in the Kasserine Region studied by project Optimize for the first six months of 2012. They show that pharmaceutical refrigerators designed for the storage of biologicals in the Kasserine Regional store (Electrolux) maintain correct temperatures. However, 79 percent of domestic refrigerators (n = 34) used in district and health center facilities have demonstrated one or more of the following failure modes: Temperature excursions above 8 C without alarm. Temperature excursions below 2 C without alarm. High-alarm incidents(s): above 8 C for more than 10 consecutive hours. Low-alarm incidents(s): below -0.5 C for more than 60 consecutive minutes. The causes of these failures have not yet been fully investigated but they include: Thermostat failure. Inadequate insulation. Door left open. Thermostat incorrectly adjusted. Prolonged power cut. 6

The responses to the failures include: Planned for replacement of refrigerator. Training provided by supervisor on refrigerator management. Discussion and recommendations Domestic refrigerators often pose higher risks for vaccines than pharmaceutical refrigerators that meet WHO norms. The risks associated with the use of domestic refrigerators for vaccine storage are evident in these results and they are well known in the literature iii,iv from other countries. The problems include: Refrigerator warm-up during a power failure is too rapid due to inadequate insulation or door seals. Thermostat allows too wide a fluctuation of temperatures and has a short life. Danger of freezing vaccines when ambient temperature fluctuates or following a power cut when ice packs have been inserted to maintain cooling. Domestic refrigerators are not classified or prequalified as medical products in Tunisia and are available at competitive prices. On the other hand, pharmaceutical refrigerators meeting WHO norms are more costly and are not available locally. Although domestic refrigerators on the Tunisian market are now subject to energy testing to national norms that ensure a higher standard of insulation and performance, they still fail to meet the WHO norms for vaccine storage. If pharmaceutical refrigerators meeting WHO norms cannot be imported for vaccine storage purposes, Optimize recommends that the Tunisian Ministry of Health should: Reclassify refrigerators intended for vaccine storage as medical equipment that should meet international or national norms of performance. Require that models be prequalified in an independent laboratory according to these norms before countries and partners procure them. Require that health workers use a wall of water-filled packs to surround the vaccines within the refrigerators to protect them from temperature fluctuations. Require that health workers follow a national standard refrigerator operating procedure. Require that health workers use 30-day temperature recorders that meet WHO norms (E006/TR06.3) to monitor the temperatures in all refrigerators used to store vaccines and that sufficient training is provided for this purpose. iii McColloster PJ. US vaccine refrigeration guidelines: loose links in the cold chain. Human Vaccines. 2011;7(5):574 575. iv McColloster P, Vallbona C. Graphic-output temperature data loggers for monitoring vaccine refrigeration: implications for pertussis. American Journal of Public Health. 2011;101(1):46 47. 7