Dupline Car Park System Type GP6220 330x 724-US 3-Colour Ultrasonic Sensor



Similar documents
Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Dupline Field- and Installationbus Dupline Profibus-DP Gateway Type G

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Drayton Digistat +2RF/+3RF

Adding Pneumatic Preset Counter. Type 497. Continuously visible preset Integrated pneumatic reset 3 or 5-digit display Convenient button setting

Dupline Carpark Guidance System

Tubular Analog model resolution: 0,5 mm (SLOW mode), 1 mm (FAST mode) Right angle Repeatibility: 0,7 mm Vdc

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Disturbance Recoder SPCR 8C27. Product Guide

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

PCS0100en Persy Control Services B.V. Netherlands

Sturdy aluminium housing, anodized in blue Female connector for optical fiber (please order optical fiber separately) Mounting holes

Inwall 4 Input / 4 Output Module

IO-DIM6 6-Channel, Digital to Analogue Converters

Operating and installation instructions. Professional plasma torch height control. Model: MyPlasm THC

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Electronic Pressure Switch EDS 300

Duct Humidity Transmitter

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

DMX2PWM 9 Channel Dimmer Setup Manual

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

DS 600. A contact free flux gate based current measurement sensor 600A rms

Modular I/O System Analog and Digital Interface Modules

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

Short information Parameters are programmed via front-side membrane keypad

IBS IP KIS A. Data Sheet INTERBUS-S. Digital I/O Module

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: Data sheet GIOD.1 V_3.0

ABB Drives. User s Manual HTL Encoder Interface FEN-31

SYSTEM 45. C R H Electronics Design

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

SYSTEM 4C. C R H Electronics Design

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

NC-12 Modbus Application

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

New XUY roller sensors

Parking Guidance System

Contents. Document information

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

Cross-beam scanning system to detect slim objects. 100 mm in

Product Information Sheet UH36 Hi Pot Tester

PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

Digital input modules

LED red (-): Measuring value < lower tolerance threshold LED red (+): Measuring value > upper tolerance threshold. Page 1/6

ATL Fuel Level Sender Probes

Voltage Regulator SPAU 341 C. Product Guide

User's Guide. Integrating Sound Level Datalogger. Model Introduction

VAV compact controller KNX / PL-Link

Frequency Converter Fv

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Install the DeviceNet Module using the following procedure:

EBDSPIR-PRM, EBDSPIR-PRM-IP

G-100/200 Operation & Installation

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Number 1 in efficiency

USER MANUAL V5.0 ST100

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

ABB i-bus EIB Logic Module LM/S 1.1

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

POINTS POSITION INDICATOR PPI4

MLC TM Maximum Productivity and Versatility for Control without Compromise!

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

Differential Charge Amplifier

ACS-30-EU-EMDR-10-MOD

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

Everything you need for protection scheme testing

PART 1 PRODUCT (GENERAL)...1.

BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC

connecdim Gateway G1 Ethernet TCP/IP to DALI

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

RealSSD Embedded USB Mass Storage Drive MTFDCAE001SAF, MTFDCAE002SAF, MTFDCAE004SAF, MTFDCAE008SAF

Electrical connection

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

PS25202 EPIC Ultra High Impedance ECG Sensor Advance Information

2M IR Mini Dome Quick Installation Guide

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

KNX IP Gateway. Light-Control R. User manual-ver.1 LC-IPGW-001. KNX Gateway. KNX/EIB Intelligent Installation Systems

Guangzhou HC Information Technology Co., Ltd. Product Data Sheet

TP32MTT.03 TP32MTT [ GB ] Probes for soil thermal profile measurement

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Charge Controller CC611/CC612 Preliminary datasheet

basicdim DGC Compact control module

MAGICAR M871A. Car alarm with two-way remote User s guide

Safety technique. Emergency stop module BO 5988 safemaster

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2012

TEMON 8-C. Doc. N MO-0370-ING TEMPERATURE MONITOR DEVICE TYPE TEMON 8-C OPERATION MANUAL. Microener - Copyright 2010 FW 2.2 Date Rev.

StructureScan HD Module. Installation Guide ENGLISH

Installation Guide. DEVIreg 530. Electronic Thermostat.

Quick Connect. quick - simple - efficient.

High Temperature InfraRed Thermometer with Laser Pointer

Transcription:

Dupline Car Park System Type GP6220 330x 724-US 3-Colour Ultrasonic Sensor Product Description GP6220 330x 724-US is an ultrasonic sensor with a built-in 3 colour LED indicator and part of the Dupline parking guidance system. The GP6220 330x 724-US sensor is installed in the middle of the ceiling above the parking bay and detects whether a car is parked in the bay. The parking bay status is indicated using the built in LEDs. The colour of the built-in LED indicator is controlled via the bus by an external device (e.g. a PC or a PLC). Different colour combinations are available to facilitate different applications. E.g. the combination red/ green/amber can be used in a parking facility with an automated booking system, and amber can indicate spaces booked for a specific event or for VIPs. Each sensor needs to be connected to the Dupline 3-wire bus. The bus provides power and enables the sensors to transmit the status of the parking bays to the carpark monitoring devices (GP3482 9091 724- X), which keep track of the number of free parking bays in an area and show the result on the connected displays. Ultrasonic sensor with a 3-colour LED indicator LED colour control via the bus Low current consumption Self-calibration of the sensor can be performed globally on all sensors at once or locally on a single sensor Automatic temperature compensation Wide measuring range Protected against dust and moisture Dupline 3-wire bus system with power Address coding with Carpark Configurator GP73800080 GP6220 3301-US has a built in red/green/amber LED indicator GP6220 3302-US has a built in red/green/blue LED indicator GP6220 3303-US has a built in red/blue/amber LED indicator culus approved Ordering key Type: Dupline Housing Input type Addresses Inputs Supply Type Selection GP 6220 330x 724-US GP6220 3301 724-US Sensor with red/green/amber LED GP6220 3302 724-US Sensor with red/green/blue LED GP6220 3303 724-US Sensor with red/blue/amber LED Input/Output Specifications Supply Specifications RJ12 connector 2x3-pin connector for address programming with Carpark Configurator GP7380 0080 Printed dot on the sensor is Dupline + D- or Gnd POW (power from or Coupler). See drawing on page 3 (System diagram) Power supply: Max. supply current Nominal Supply 21 V min.; 30 V max. (Overvoltage category III (IEC60664)) 20 ma 28 V / 19 ma 0,53 W 1x2-pin connector. NOTE: The sensor connectors are using the push-wire connection methode. Use a 1.5 mm 2 single core wire for the sensor installation. Specifications are subject to change without notice (05.08.2014) 1

General Specifications Ultrasonic frequency Max. distance between ceiling and floor Min. distance between ceiling and floor Min. calibration distance Hysteresis Sensor in Normal mode Sensor activations time Sensor in mode Sensor activations time 40 khz 4.0 m 1.5 m 1.5 m ±30 cm 3 sec. See fig. 1 (Default) 0.4 sec. with a max car speed on 20 km/hour. See fig. 2 Programming unit GP7380 0080 Sensor temperature compensation The sensor uses one Dupline input address The built-in temperature compensation makes the sensor stable and reliable without any calibration is used to transmit the status of the sensor on the bus The sensor uses 3 Dupline output addresses Calibration address LED CH1, LED CH2 Default adress is used for global cali bration. Common address for all sensors on the bus These two addresses are used for control of the LED colour. LED CH1 = A1 LED CH2 = A2 LED colour coding GP6220 3301 724-US LED CH1, LED CH2 = 0,0 Green LED ON LED CH1, LED CH2 = 0,1 Amber LED ON GP6220 3302 724-US LED CH1, LED CH2 = 0,0 Green LED ON LED CH1, LED CH2 = 0,1 Blue LED ON GP6220 3303 724-US LED CH1, LED CH2 = 0,0 Blue LED ON LED CH1, LED CH2 = 0,1 Amber LED ON Approval culus (UL60950) In case of a Dupline fault the sensor s red LED will start flashing at 1 second intervals. System Diagram GP34960005700 L 1 120 <= 26 <= 24 Sensor Sensor Sensor Sensor Sensor Sensor <= 32 GP34960005700 L 1 120 G3496005700 Master Monitor <= 082 NOTE: The on L 1 must be the type GP3496 0005 700. The on must be an another type. We recommend the G3496 0005 700 because of the modbus RTU protocol 2 Specifications are subject to change without notice (05.08.2014)

Mode of Operation The ceramic sensor emits an acoustic signal at a frequency of 40 khz. The signal is reflected when it hits the floor and returned to the sensor. The reflected signal indicates whether the parking bay is available or occupied. Sensor addresses Status Dupline address The Dupline bus address used by the sensor to transmit the status of the parking bay. Calibration Dupline address This address is used to trigger the sensor to perform a self calibration. Several sensors can be given the same calibration address, thereby making it possible to calibrate multiple sensors at once by sending a single trigger signal on that address. The programming unit GP73800080 is used to send out the trigger signal. Modes The sensor has two modes. Normal mode or mode. In Normal mode, the sensor is designed to be mounted in the ceiling directly above the car in the Carpark bay. The sensor detects the presence or no presence of a car and sends a signal on the Dupline bus to the Carpark Monitor and Master module. Through the modbus interface of the Carpark Master Module GP34960005 the PC/PLC can control the status of the two Dupline bit-addresses (LED CH1, LED CH2) assigned to the sensor. Each of the four bit-combinations will result in a specific indication as shown above under LED colour coding. The sensors will not react to objects lower than 30 cm. To avoid a weak signal, the sensor must be installed pointing directly at a hard surface, as for instance concrete. A soft or uneven surface will reduce the signal. In mode, the sensor is designed to be mounted in the ceiling above the lane. The sensor is able to detect moving cars with a maximum speed of 20 km/hour. See fig. 2 on page 4. When the sensor detects a moving car it sends a signal to the Carpark system that reduces the total amount of free places. The reduced amount is shown on the local display - but also on the display that shows the total amount of free places. This is to prevent to many moving cars in a specific carpark area. The sensor does not show the actual status on the LEDs. The LEDs only work as feedback during calbration, startup and show the fail status. The sensor is designed to work in an area which is: 2.02,5 mm Parking Parkeringspladser Spaces Max. 4 m Min. 1.5 m 4 m 0.3 0,8 mmeter The sensor Sensoren will reagerer not react ikke på to emner objects mindre lower end than 0,8 m. 0.3 m. The Sensoren sensor can kan operate operere in i 4 a m 4 m lang long og and 2,5 2 m bred wide parkeringsplads parking bay The sensor should be placed freely, e.g. in the following way: Mounting the Sensor Sensor B MAX ±5 Ceiling beam Loftbjælke A A A = = Min. 202 meter cm mellem between loftbjælker ceiling beams B B = = Max. 65 50 cm høje tall loftbjælker ceiling beams To receive the best signal, the sensor must be installed with an angle on the ceiling on maximum ±5. Specifications are subject to change without notice (05.08.2014) 3

Calibration The sensor is self-calibrating. It is important to perform the ca libration when the parking bay is empty. There are two ways of calibrating a sensor. Manual calibration is a local calibration of the single sensor. - Push the button on the outside of the sensor. - The LED flashes green for 30 seconds with 1 Hz. (The electrician has time to get clear of the sensor before the calibration starts). - The calibration starts when the LED flashes green for 6 seconds with 4 Hz. - If the calibration is OK, the LED will respond with a constant green light. Error messages: - If the calibration fails, the LED will respond with a constant flashing red light. If the LED flashes red, the sensor could be out of range or the sensor is not aligned correctly. - Adjust the sensor into the sensing area and recalibrate the sensor. - If Dupline is not connected/defect the LED will flash red. - If Dupline is short circuit the LED will flash red. - Sensor first time start up. The sensor LED will flash red because it needs calibration. Automatic calibration with the Carpark Configurator GP7380 0080 is a global calibration of all connected sensors. The parking bay must be empty during the calibration process. Fig. 1 and Fig. 2 Fig. 1 Fig. 2 Sensor 4 Sensor 5 B1 B2 B3 B4 B5 LED indicator (Optional) sensor LED indicator (Optional) The sensors can be used as both parking bay (Normal mode) and lane sensors ( mode). See the manual on how to program the sensors. Fig. 2 Environment Dimensions Protection: IP 34 Operating temperature: -40 C to 70 C Storage temperature: senor -40 C to 85 C Pollution Degree: 3 (IEC 60664) Dimensions: Ø118 x 76 mm Material: The case is made of polypropylene. The sensor lid is made of clear Polycarbonate. 118 mm 76 mm Push button for local calibration 4 Specifications are subject to change without notice (05.08.2014)

Bottom part: mounted in ceiling Wiring Diagram Programmable connector for GP 7380 0080 Power D- To other sensors To other sensors D- X Power Y Note: The 2 x 3 pin connectors are internally connected on the PCB. Note: X and Y is not in use for model number GP6220 330x- US. NOTE: The wiring of the sensors must always be made with 1.5 mm 2 single core wire Connection diagram D- 24 V Sensor X GP3496 0005 700 Specifications are subject to change without notice (05.08.2014) 5