DMX Relais /Analog Interface. User Manual



Similar documents
DMX-RELAIS 2 INRUSH. User manual

USB-DMX STAGE-PROFI MK2. User Manual

ArtNet-LED-Dimmer 4 ArtNet-LED-Dimmer 4R

Modular I/O System Analog and Digital Interface Modules

DMX2PWM 9 Channel Dimmer Setup Manual

MADRIX NEO Quick Start Guide & User Manual

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

PS25202 EPIC Ultra High Impedance ECG Sensor Advance Information

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

PUSH CV. Vi säljer och konsulterar Ledbelysning. Utebelysning Innebelysning Led-strip RGB Drivdon. SÄLJKONTOR Torstensviksvägen Frillesås

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

User manual BETSO WTCS. 16 channel wireless digital TC slate. 1 Copyright BETSO ELECTRONICS Ltd.

Video Splitter VS-104 / VS-108 User's Manual

Data sheet GIOD.1 Input/output module with CAN bus. ERP no.: Data sheet GIOD.1 V_3.0

ASP-DTH. DVI & Audio to HDMI Converter. User Manual. Manual Number:

DR 70 Portable Digital DAB+ and FM Radio Receiver User Manual English Please read carefully before using this product

MIDI control allows the Split Personality to be used remotely in rack systems, or integrated into MIDI controlled setups for easy preset recall.

T O K I S T A R L I G H T I N G I N S T R U C T I O N M A N U A L LC-1CH-MULTI Dimmer Module

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

Single Channel Loop Detector

POINTS POSITION INDICATOR PPI4

ITA3D 710. RGB DMX laser with 3D effect. User manual

WEB log. Device connection plans

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Product Information Sheet UH28CS-12kV Hi Pot Tester

Product Information Sheet UH36 Hi Pot Tester

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

KNX Gateway RGK E-01

GV- RK1352 Card Reader

DISCRETE SEMICONDUCTORS DATA SHEET M3D848. CGD MHz, 20 db gain power doubler amplifier. Product specification 2002 Oct 08

Contents. Document information

USER MANUAL V5.0 ST100

9,'(2 #6(3$5$725 8VHU V#0DQXDO 96043;

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Note monitors controlled by analog signals CRT monitors are controlled by analog voltage. i. e. the level of analog signal delivered through the

9,'(2 #6(3$5$725 8VHU V#0DQXDO

2-Wire/4-Wire Telephone Line Interface. XE0204 Block Diagram

LynX TM Silicon Photomultiplier Module - LynX-A T1-A User Guide Understanding Silicon Photomultiplier Module for improving system performance

Duct Humidity Transmitter

TR7322U-OR RDS / MP3-USB TUNER (24 Volt)

USER MANUAL MODEL

Controlers. Controler

WHITE PAPER. LVDS Flat Panel Display Interface on Intel Desktop Boards. July 2009 Order Number: E

X8 Option 2 - Technology

VE02AL / VE05AL / VE02ALR VGA & Stereo Audio CAT5 Extender with Chainable Output

TYXIA. * _Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF channel

ServoOne. Specification. Option 2 - Technology. x 11. x 8 X 8. x 10. x 9. x 7. x 6 TTL Encoder / TTL Encoder simulation

Multifunction devices

USB I/O CONTROL BOX 8 relays, 8 digital I/O lines and 8 HV inputs

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Product Information Fire alarm panel 8000 C

ABB Drives. User s Manual HTL Encoder Interface FEN-31

RC Camera Control. User Guide v /20/2012

RGB Wall Washer Using ILD4035

Original instructions Tina 3A/Aps Adaptor unit

Multi-Protocol decoder with Load regulation

ECD 2 High Performance Balanced DAC. 24 Bit /192kHz. Owner's Manual

Data Sheet. Adaptive Design ltd. Arduino Dual L6470 Stepper Motor Shield V th November L6470 Stepper Motor Shield

Features, Benefits, and Operation


VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

PS 155 WIRELESS INTERCOM USER MANUAL

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Hardware Manual CAN-IB130/PCIe CAN-IB230/PCIe PCIe/104 CAN Interface

Multi-Protocol decoder

Tina 2A/B Adaptor unit

WEB log. Device connection plans

NC-12 Modbus Application

Wireless DMX Connector

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

How To Use A Ves-0116 Video Splitter With Audio And Video From A Computer Or Tv Aten (Ves-116)

Total solder points: 167 Difficulty level: beginner advanced DMX CONTROLLED RELAY K8072 ILLUSTRATED ASSEMBLY MANUAL

T0118 T2118 T3118. Instruction Manual

NEW. EVEN MORE data acquisition and test stand automation

SMS GSM Alarm Messenger

Description ELGO PNO 1 SSI/ Profibus - Converter

DK40 Datasheet & Hardware manual Version 2

HSeries. High Power High Quality. Ultra-High Speed, Sensing Ionizer SJ-H Series

RX-AM4SF Receiver. Pin-out. Connections

US-SPI New generation of High performances Ultrasonic device

Copyrights 2010 Victron Energy B.V. All Rights Reserved

DCREG INTERFACE VIA DEVICENET

KAB-ADAPT-LVDStoTTL. Document Revision 1.0

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

BITxxPA. RF Power Amplifier. Applications. Product Description. Key Features

Digital Keypad Use s Manual

Technical Description. Multifunctional Desk-Top Call Station Digital Version 8, 16 Keys L.No ,

DLP-PU/E Instruction Manual

F2400 FOM II Series Fiber Optic Modem Technical Manual

Recording Server Module BANK

Temperature & Humidity SMS Alert Controller

I STAR COMPUTER CO., LTD

Operating instructions for built-in electronic timers with Day and Week programms. Series 884

E&P HYDRAULICS Remote control EPRC-01 Level System Camper

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

7 OUT1 8 OUT2 9 OUT3 10 OUT4 11 OUT5 12 OUT6 13 OUT7 14 OUT8 15 OUT9 16 OUT10 17 OUT11 18 OUT12 19 OUT13 20 OUT14 21 OUT15 22 OUT16 OUT17 23 OUT18

Automotive CAN gateway module

Transcription:

DMX Relais /Analog Interface User Manual

DMX RELAIS/ANALOG INTERFACE 2 Description The DMX Relais and Analog Interfaces are designed for controlling tasks different kinds. Thereby 4 independent switching contacts and 2 analog 0-10V outputs are available. RELAY 1 RELAY 2 DMX DMX INTERFACE RISC CONTROLLER RELAY 3 RELAY 4 ANALOG 1 ANALOG 2 The board has on one site 3 or 5 pin XLR-connectors as well as the address settings via DIP-switch. Technical Data Power supply: 12V DC / 500mA DMX-channels: depending on operating modes 6 or 8 channels DMX-connections: via 3 or 5 pin XLR-connector (Depending on version) Outputs: 4 switching output (reverser) max. 5A / 250V~ 2 analog outputs 0-10V with 256 or 1024 steps Board dimensions: 100mm x 73mm

DMX RELAIS/ANALOG INTERFACE 3 LED-Display The LED is a multifunctional display. In the normal operation mode the LED lights non-stop. In this case the device is working. If the LED is permanently dark, there is no DMX512-input-signal. Furthermore the LED signals the operation status. In this case, the LED lights up in short pitches and then turns into off modus. The number of flashing signals is equal to the number of the error status: Error Error Description status 1 Settings saved The settings are saved 2 Address error Please check if a valid DMX-starting address is adjusted at the DIP-switch 3 DMX-signal erro An invalid DMX input signal is determined, invert the signal line by changing switch 2 and 3 or use a twisted pair wire. Addressing The starting address is adjustable via a DIP-Switch. Switch 1 has the valency 2 0 (=1), switch 2 has the valency 2 1 (=2) and so on finally switch 9 has the valency 2 8 (=256). The sum of the switches showing ON, represents the starting address. Address Switch Address Switch 1...... 2 508 3 509 4 510 5 511

Setting the operation mode DMX RELAIS/ANALOG INTERFACE 4 The analog outputs of this DMX-Interface can be conducted with a resolution of 8Bit (256 steps) or 10Bit (1024 steps). You define the operation mode by setting switch 10 on ON. Then you can perform the settings as follows: Switch 1 open 8 Bit (256 steps) Switch1 closed 10 Bit (1024 steps) Switch 2 open Switch 2 closed Outputs will be shut down at DMX-breakdown Outputs stay in the latest condition at DMX-breakdown Please carry out the settings in a power supply free condition and switch on the power supply to save the settings. The LED flashes now with the error status 1. Depending on the analog outputs resolution one or two DMX-channels are necessary. The following table shows the DMX-channels assignment: DMX-channel 8 Bit operation 10 Bit operation 1 Analog 1 Analog 1 roughly 2 Analog 2 Analog 1 fine 3 Relais 1 Analog 2 roughly 4 Relais 2 Analog 2 fine 5 Relais 3 Relais 1 6 Relais 4 Relais 2 7 Relais 3 8 Relais 4

Connecting the interface DMX RELAIS/ANALOG INTERFACE 5 DMX OUT 1 GND 2 DATA- 3 DATA+ DMX IN 1 GND 2 DATA- 3 DATA+ DMX-starting address Switching output Power supply Analog outputs

DMX RELAIS/ANALOG INTERFACE 6 Dimensions Board fixation 4x d=4 23 73 69 4 8 26 7 17,8 23 96 100 Front cover cutaway 4x d=3,2 2x d=3,2 22 10 3 2,54 22,4 7,62 2,6 12,5 8 26 33 40,9 50,8 60,7 63,9 73,8 83,7 (all infos in mm)

DMX RELAIS/ANALOG INTERFACE 7 CE-conformity This assembly (board) is controlled by a microprocessor and uses high frequency (8MHz). To get the characteristics of the assembly in relation to the CE-conformity, an installation in a compact metal casing is necessary. Risk-Notes You purchased a technical product. Conformable to the best available technology the following risks should not excluded: Failure risk: The device can drop out partially or completely at any time without warning. To reduce the probability of a failure a redundant system structure is necessary. Initiation risk: For the installation of the board, the board must be connected and adjusted to foreign components according to the device paperwork. This work can only be done by qualified personnel, which read the full device paperwork and understand it. Operating risk: The Change or the operation under special conditions of the installed systems/components could as well as hidden defects cause to breakdown within the running time. Misusage risk: Any nonstandard use could cause incalculable risks and is not allowed. Warning: It is not allowed to use the device in an operation, where the safety of persons depend on this device.

DMX4ALL GmbH Reiterweg 2A D-44869 Bochum Germany Copyright 2009 DMX4ALL GmbH All rights reserve. No part of this manual may be reproduced in any form (photocopy, pressure, microfilm or in another procedure) without written permission or processed, multiplied or spread using electronic systems. All information contained in this manual was arranged with largest care and after best knowledge. Nevertheless errors are to be excluded not completely. For this reason I see myself compelled to point out that I can take over neither a warranty nor the legal responsibility or any adhesion for consequences, which decrease/go back to incorrect data. This document does not contain assured characteristics. The guidance and the characteristics can be changed at any time and without previous announcement.