Engine Power Plant 5,2 MW Stationary Dual Fuel (Diesel / Gas ) Engine (12 VDS 48/42 )



Similar documents
Current state of plant Functioning as a peak and emergency centre. Statistics Accumulated operating hours:

Technical Specification. Generating Set with Waukesha engine burning natural gas

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Refrigeration Compressed Air Dryer Buran Ultrapulse

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

Diesel Generating Set

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

Ambient Temperature Operation and Matching MAN B&W Two-stroke Engines

Specifications for Volkswagen Industrial Engine

WÄRTSILÄ 50DF PRODUCT GUIDE

Half the cost Half the carbon

Annex-A TECHNICAL SPECIFICATION

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL

Diesel Engine Driven Generators Page 1 of 6

Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1

Atlas Copco Generators

OUTCOME 2 INTERNAL COMBUSTION ENGINE PERFORMANCE. TUTORIAL No. 5 PERFORMANCE CHARACTERISTICS

Technical data UNIBLOCK UBSF

Floating. Diesel power stations

WÄRTSILÄ 34DF PRODUCT GUIDE

Heavy Fuel Oil supply units. The world s best selling HFO supply unit. The right choice for any conditions

Energy Savings through Electric-assist Turbocharger for Marine Diesel Engines

Rotary screw compressors kw 5,5 7, , bar MODULO

5. State the function of pulveriser. The pulverisers are the equipments which are used to powdered coal.

IEA Workshop Copenhagen Small scale biomass co-generation with modern steam engines

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Top Technology for Industry, Agriculture, Business and Communities

LANDFILL GAS TO ENERGY- COMBINED ENGINE AND ORC-PROCESS

Basic Hydraulics and Pneumatics

MANTA Piston Distributor for Oil and Fluid Grease

MEMBRANE VACUUM MINI PUMPS

C18 ACERT Fire Pump Tier bkw/ rpm

AIR-CONDITIONER SPLIT TYPE

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

12 November 2008 *** I:\CIRC\MEPC\01\642.DOC INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR

Titan Makina Ltd. Şti Sok. No: 9 Ostim Ankara Tel: Fax: Web:

Unit 96: Marine Propulsion Power Plant

Why and How we Use Capacity Control

ORC TURBOGENERATOR TYPE CHP - Organic Rankine Cycle Turbogenerator fed by thermal oil, for the combined production of electric energy and heat -

Screw Compressors 11-22kW

MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM. Key features: NOVAIR quality and service:

Experimental study on atmospheric pollutant emissions from heating systems, in Italy

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

SP 4K/5K Efecto & SP 5K Brilliant Parallel Installation Guide 1. Introduction

Portable Compressors MOBILAIR M 270 With the world-renowned SIGMA PROFILE Free air delivery 20.0 to 26.9 m³/min.

1 DESCRIPTION OF THE APPLIANCE

ROTARY SCREW COMPRESSOR. RMD kw

HYDRUS ULTRASONIC METER

Wind-Diesel Hybrid System Options for Alaska. Steve Drouilhet National Renewable Energy Laboratory Golden, CO

Compact Air Solutions C Series kw Screw Compressors Want a 5. year warranty? Ask for details!

ECOCIAT. Domestic hot water heat recovery unit

DIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET

Rickmeier Solutions. Gear pumps for superior Lubrication

Rotary Screw Compressor. MSM MINI 2, ,5 kw

Portable Compressors MOBILAIR M122 With the world-renowned SIGMA PROFILE Free air delivery 11.1 m³/min.

Offshore Platform Powered With New Electrical Motor Drive System

Digital Pressure Measuring Instrument MDR480

Series description: Wilo-Star-Z

BHKW. Power. Power. Gas engines for CHP units and gensets. MAN Engines. A Division of MAN Truck & Bus

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

SIX REASONS TO DRY BIOGAS To A LOW DEWPOINT BEFORE COMBUSTION IN A CHP ENGINE STEVEN SCOTT MARKET DEVELOPMENT MANAGER ALTERNATIVE ENERGIES

THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER

300 Series PA Pump and Cooler Assemblies

Marine Generating Sets 3.7 to 50 kva

ETC -SV. Class 0 oil-free compressed air through catalysis

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

Torino Nord. Cogeneration Plant. The gas turbine. The steam generator. The Torino Nord cogeneration plant produces electricity and heat for district

Table Z. Troubleshooting Chart for Air Conditioners. Cause

Electric Coolant Pumps. Always at the Correct Temperature

DRYPOINT AC HP PREMIUM HIGH-PRESSURE DRYING

DIESEL GENERATOR SETS

Quick Connect. quick - simple - efficient.

Element D Services Plumbing

Installation and maintenance instructions. Danfoss Vent

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

These pumps provide a well proven solution in many cases.

912. The engine for construction equipment.

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

ONE STAGE LIGHT OIL AND KEROSENE BURNERS

POLYCITY. Technical measures and experiences at a 6 MW cogeneration plant with wood chip furnace POLYCITY

Catalogue Wilo- Stratos PARA

4KVA/5KVA Parallel Installation Guide

OPERATING MANUAL. Table of contents. 2 Phase Stepping Motor Driver 2M542. Rev. A. Introduction page 2. Specifications page 2 Timing chart page 3

TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

AGP15 Perkins Series Gen Set Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ

Condensate water pump with neutralisation system

Electronic Diesel Control EDC 16

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

GEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer

Data Realty Colocation Data Center Ignition Park, South Bend, IN. Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures

A study into the fuel savings potential by a major rebuild of propulsion system

Phase Modular Finally the benefits of Modular ups are for all

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

1. A belt pulley is 3 ft. in diameter and rotates at 250 rpm. The belt which is 5 ins. wide makes an angle of contact of 190 over the pulley.

MODERNIZATION OF STEAM GENERATORS

HEATER, AIR CONDITIONING AND VENTILATION

Transcription:

Engine Power Plant 5,2 MW Stationary Dual Fuel (Diesel / Gas ) Engine (12 VDS 48/42 ) Table of Contents 1. General technical description 2. Specification of the equipment 2.1 Diesel / gas unit 2.2 Alternator 2.3 Description of systems 2.3.1 Foundation work 2.3.2 Lubricating oil system 2.3.3 Cooling water system 2.3.4 Charge air and exhaust gas system 2.3.5 Compressed-air system 2.3.6 Ventilation system 2.3.7 Measurement and control system of the engine-alternator-set 2.3.8 Medium voltage system 3. Consumption figures per engine 4. Technical marginal conditions 4.1 Ambient conditions 4.1.1 Design data 4.2 Process materials 4.2.1 Electrical power 4.2.2 Medium voltage 4.2.3 Fuel 4.2.3.1 Gas or diesel oil 4.2.4 Lubricating oil 4.2.5 Steam and condensate system 4.2.6 Cooling water / jacket cooling water 5. Documentation 1. General technical description The engine power plant is a unit with gas and diesel fired engine of the type 12 VDS 48/42. The engine is directly connected with a self-starting, brushless three-phase alternator. The offer includes the complete power plant, consisting of the one dual fuel diesel / gas engine of the aforementioned type with the belonging alternators, the motor control boxes and speed control units, the foundation documents, spring elements, the specification of important parts, the nozzle heating modules, the elastic connecting elements between engines and pipe systems, engineering as well as deliveries of components concerning the lubricating oil system to be specified in detail.

The engine 12 VDS 48/42 AL works with diesel and gas. The fuel oil used in diesel operation is light fuel or diesel oil. It is supplied to the engine from a storage tank by means of fuel oil system units., For reasons of operating safety, the engine unit have a own cooling system. The heat resulting from the cooling of the engine, jacket cooling water and charge air cooling 1 st stage (intercooler), are carried away to the hot water system. Moreover, the unit have its own lubricating oil system, with a pump supplying lubricating oil to the engine from a separate circulation tank. The tank should be installed at a lower level nearby the engine. Filters for the cleaning of the oil should be installed between pump and engine. For treatment of the lubricating oil, separators should be used for each engine unit, which separate the lubricating oil in bypass. The emissions contained in the engine exhaust gas (pollutants and noise) must not be released uncontrolled to the environment. The pollutants, above all nitrogen oxides and carbon monoxide are therefore reduced in a SCR-catalyser with oxidation number. Depending on the site, noise emissions have to be reduced to permissible values through an exhaust gas silencer and constructional project measures. The exhaust gas is carried off through a chimney. Compressed air (30 bar/10 bar) start the engine. The total plant is controlled and regulated by a central process control technique which is in the scope of supply. The control system includes the engine protection and alternator protection. In case of emergency stop, the fuel supply to the engines will be cut off and the alternator switch will be opened. The maximum output depends on the conditions on site. All data of engine and alternator referred to are based on standard conditions. 2. Description of the scope of supply of the MBH Engine-Generator Set MBH Engine-Generator Sets consisting of a MBH Engine 12 VDS 48/42 and a synchronous alternator. Length: 8.5 m Height: 5.5 m Height with concrete block: 8.0 m Width: 4.0 m Engine and alternator coupled directly. Both, engine and alternator will be mounted with separate base frames on the top of a concrete block.

MBH Engine 12 VDS 48/42 2.1 1 engine 12-cylinder, 4-stroke-system, V-engine, with direct fuel injection, exhaust gas turbo charger and 2-stage charge air cooling, equipped for operation with gas and oil. Maximum nominal output: 5300 kw Nominal speed: 500 1/min const. Cylinder bore: 420 mm Piston stroke: 480 mm Configuration:... V-type engine Piston capacity: 66,5 litre per cylinder Mean effective pressure: 15,9 bar Mean piston speed: 8 m/s Weight: ca. 90 t 2.2 Alternator

1 Synchronous Alternator Apparent output: 6400 kva Effective output: 5120 kw Power factor: cos phi = 0,8 Frequency: 50 Hz Voltage: 10,5 kv 2.3 Description of systems 2.3.1 Foundation work The foundation consists of the static foundation (sub-foundation), the elastically bedded vibrating foundation, the foundation base frame separate for engine and alternator - spring elements and fasteners. The engine/alternator set is screwed up on the vibrating foundation. In order to avoid the spreading of impact sound, the vibrating foundation is elastically bedded on spring elements. Dynamic forces are not passed on to the subfoundation. 2.3.2 Lubricating oil system The lubricating oil system supplies lubricating oil to the engine and passes the heat of the engine contained in the oil on to the cooling water system. It is required to use lubricating oil of the SAE class 40 with a maximum operating temperature of about 70 C behind the engine and a working pressure of about 4,5 bar before the engine. The lubricating oil pressure and temperature are being monitored. The lubrication oil system of the engine is a circuit from the lubricating oil circulation tank over lubricating oil pump, lubricating oil cooler, lubricating oil automatic filter and indicating filter to the engine and back to the lubricating oil circulation tank. The operation is monitored through motor-acted control. Monitored values are temperature (max) and pressure (min). The lubricating oil is cleaned in the main circuit by means of the automatic filter and the indicator filter and in the bypass flow in a special circuit by means of the separator. The plant is designed with a separator for each engine/alternator set. The residues resulting from the separation are collected in the lubricating oil sludge tank of the separator and pumped into the sludge tank of the fuel oil system. From the joint lubricating oil tank and pump unit, lubricating oil is transported to the respective lubricating oil circulation tanks and to the internal cylinder lubrication systems of the engine. 2.3.3 Cooling water system The cooling water system of the engine plant takes care of the carrying off of heat from the 2 nd stage of the charge air cooler (intercooler) and of the lubrication oil system. The secondary cooling water system is a closed circuit from the circulation pump over the heat exchanger to the air cooler and back to the pump. The operation is monitored by motor control. Monitored values are temperature and pressure. The secondary cooling water system consists of the components circulation pump, dry coolers, cooling water service tank with refill/pressure maintaining pump and membrane expansion tank. 2.3.4 Charge air and exhaust gas system The exhaust gas and charge air system of the engine serves to supply the engine with

charge air and to carry off exhaust gases of the engine. Through direct engine suction from the power house, the charge air passes a silencer of the exhaust gas turbo charger. As alternative and when required by the local conditions, the charge air can be fetched through a filter, a silencer and a suction line from outside the power house. The heat of compression resulting from the process of compression of the intake air in the exhaust gas turbo charger is carried off to the cooling water system by means of a charge air cooler (intercooler). The operation is monitored by motor control. Monitored value is the temperature (max). This value is indicated through motor control. The exhaust gas system consists of the pipes, the pipework equipment, silencer, exhaust gas cleaning system, exhaust gas boiler, chimney and various fixing devices. 2.3.5 Compressed air system The compressed air system supplies the engine and the components of the plant with the necessary control and working air. Two compressors fill two compressed-air bottles of 1000l each and with a working pressure of 30 bar. The compressed air with 30 bar is used as starting air for the diesel engines. In a second system, compressed air is reduced to 10 bar which serves to the control and monitoring systems of engine and plant components. Compressors and compressed-air bottles are integrated in one system unit for both engine plant. 2.3.6 Ventilation system The ventilation of the power house has to be designed in a way that the necessary charge air for the engines as well as the dissipation of the radiant heat from the particular units and system components guarantee a safe engine operation. 2.3.7 Measurement and control system of the engine alternator set The engine control boxes, speed control (Heinzmann) as well as the cabling of the engine control boxes Heinzmann controller belongs to the scope of supply. Moreover, for the total plant, there have to be dimensioned and specified: - fire alarm system - low voltage main distribution - grounding and equipotent bonding - For motor control: - all necessary control boxes and systems to operate the motor control (control, monitoring, 400V-drive distribution, etc.) - SPS - software for the monitoring and control of all engine systems - emergency shutdown circuit motive power unit - engine control (start, stop, charge, discharge, modification of operational mode) and monitoring - lubricating oil system, jacket cooling water system, fuel oil system, charge air and exhaust gas system, hot and secondary cooling water system with air cooler - protection and automatic synchronisation of the alternator - monitoring of the bearing temperature - monitoring of the winding temperature - differential protection

- monitoring stator earth - monitoring overload (graduated) - monitoring short circuit (graduated) - directional circuit breaking - monitoring of voltage (+/-) - monitoring of frequency (+/-) - monitoring of short interruption - processing of the signals from the exciting unit - measurement, display, counting of the electric values - hardware locking circuit for engine protection - 24V USV unit for engine plant - 24V supply for the motor control unit with charging set and battery unit - general control all necessary switch boxes and systems to operate the general system (control, monitoring, 400V drive distribution, 24V-distribution etc.) - SPS - software for monitoring and control of the following systems - medium voltage unit - low voltage distribution - 24V USV-unit - compressed air system with compressors - emergency shutdown for the engine unit - separator unit - tank unit, fuel oil system units 2.3.8 Medium voltage unit 10,5 kv Consisting of: - alternator feeding field - cable outlet field - cable outlet field to the existing unit - cabling 3. Consumption figures per engine Natural Gas: 230 cubic meter/mw +/- 10 % Lubricating oil: approx. 400 t/a 4. Technical marginal conditions 4.1 Ambient conditions 4.1.1 Design data air intake temperature (power house, min.) 10 C air intake temperature (power house, max.) 40 C Relative humidity, normal 70 % installation altitude < 500 m above M.S.L. Dust concentration in the air < 10 mg/m³ 4.2 Process materials 4.2.1 Electrical Power Network AC 3-phase (3PNE)

Voltage 230/400V +/-2% Frequency 50 Hz 4.2.2 Medium voltage Type 3-conductors Frequency 50 Hz Voltage 10,5 KV 4.2.3 Fuel 4.2.3.1 Gas or diesel fuel oil Net calorific value Hu 42 700 kj/kg Viscosity 40 C ca. 2 6 cst Density 15 C ca. 0,81 0,85 g/ml Flash point >60 C (according to Pensky-Martens) Pour point -9 C Sediment < 0,30 % w/w Water < 0,20 % w/w Sulphur < 1,0 % w/w Ash < 0,01 % w/w Cetane number > 45 Specification DIN 51601 DIN 51603 4.2.4 Lubricating oil The specification of the lubricating oil has to be specifically selected for the prevailing engine operating conditions. The quality and type of the lubricating oil to be used are subject to prior approval by MBH. Viscosity class SAE 40 Viscosity 40 C ca. 145 cst 100 C ca. 14.5 cst Density at 15 C ca. 890 kg/m³ Flash point > 220 C Pour point - 15 C TBN diesel oil 10-20 mg KOH/g Ash (as sulphatees) < 0.75 % w/w Ash (as oxides) < 0.02 % w/w Possible suppliers: Shell Argina 40 Esso Exmar 40 Texaco Taro 40 Mobil Mobilgard Fina Stellano Castrol TLX Water quality according to the special prescriptions of the tank manufacturer 4.2.5 Fresh water

Fresh water is required for producing internal cooling water, for turbine washing, in the separator etc. Limits: PH (25 C) 6,5 7,5 Conductivity 25 C < 1000 ms/m Total hardness (Ca²+, Mg²+) < 20 dh Silicate (as SiO2) < 15 mg/l Chloride Cl- < 50 mg/l Sulphate (SO4 ²-) < 50 mg/l Fe < 0.02 mg/l Appearance clear, colourless, free from un-dissolved matter 4.2.6 Cooling water / jacket cooling water The cooling water and jacket cooling water have to be treated according to the below requirements. The cooling water system forms a closed circle together with the jacket cooling water system. This cooling circuit must be treated with the corrosion preventive CWT Diesel/QC2. Before using a different corrosion preventive, it is necessary to consult the engine manufacturer. Only those reagents may be used, which prevent corrosion and cavitations during the operation and stop period of the plant and which do not act upon material and seals in the cooling system. Water quality Water type : fresh water, free from solid foreign substances Total hardness : max. 8 dh Permanent hardness: max. 3 dh ph value of the untreated water at 20 C 7 8 ph value of the water in the cooling circuit at 20 C 8 9 level of chlorides and sulphates max. 50 mg/dm³ level of cilicic acid max. 30 mg/dm³ 5. Documentation The following documents in German or English language are part of this plant documentation: - installation drawing engine - Specifications of operating material and possible components (MBH scope of supply) - key plans and flow chart (proposal) - foundation documents