NCCEP Standards. NCCEP Standards for EMS Equipment



Similar documents
OFFICIAL AIR AMBULANCE, GROUND AMBULANCE, AND FIREFIGHTING AGENCY INVENTORY

PENNSYLVANIA DEPARTMENT OF HEALTH EMERGENCY MEDICAL SERVICES OFFICE. Vehicle # ALS Mobile Care and BLS Inspection Checklist

DEPARTMENT OF PUBLIC HEALTH AND ENVIRONMENT. Health Facilities and Emergency Medical Services Division

Enables MDA Medical Teams to categorize victims in mass casualty scenarios, in order to be able to triage and treat casualties

ALS Ambulance. Limited (L-ALS) Laryngoscope blades (Adult) straight 1 set 1 set N/A 1 set

SECTION OF EMERGENCY MEDICAL SERVICES MINIMUM REQUIRED EQUIPMENT LIST PARAMEDIC

Premier Pharmaceutical, Medical Equipment, Supply and Distribution FAQs

Ground Vehicle Supply Requirements for EMR Quick Response Units.

Health System Compliance Division Inspection Department Ambulance Inspection Checklist Class III Advanced Life Support (ALS)

Pediatric Equipment for Ground Ambulances

CITY OF HOUSTON Department of Health and Human Services Emergency Medical Services Program

CITY OF HOUSTON Department of Health and Human Services Emergency Medical Services Program

SUBJECT: BASIC LIFE SUPPORT AMBULANCE EQUIPMENT REFERENCE NO. 710

CONTRA COSTA HEALTH SERVICES EMERGENCY MEDICAL SERVICES

GENERAL INSTRUCTIONS. The regulations can be downloaded from the Section s web site at: 2 AS

APPLICATION FORM FOR ADVANCED LIFE SUPPORT AMBULANCE. (For Certification by Committee for Registration of Ambulances in Delhi)

EQUIPMENT FOR GROUND AMBULANCES Summary of Changes

Emergency Medical Services Division. ALS Bike Medic Program Policies and Procedures August 15, 2014

Located On IV Pole Front of cart- Arrest Board

SAN LUIS OBISPO COUNTY EMERGENCY MEDICAL SERVICES AGENCY PREHOSPITAL POLICY

Scope of Practice Approved by the State Board of EMS (EMS Board), within the Division of EMS of the Ohio Department of Public Safety

County of Kern. Emergency Medical Services. ALS BOAT MEDIC PROGRAM May 13, 2013

Registration of Ambulances

Required Ground and Air Ambulance Equipment and Supplies

Required Ground and Air Ambulance Equipment and Supplies

Aerospace Medical Association

Ground Ambulance Equipment and Supply List

AHA Instructor Renewal

DRAFT V5 09/14/ Air ambulance services.

ESIC MODEL HOSPITAL CUM ODC

Southern Stone County Fire Protection District Emergency Medical Protocols

Standards for type V air ambulance vehicles and equipment. (a) The operator shall ensure that the patient compartment is configured in

Virginia Office of Emergency Medical Services Scope of Practice - Procedures for EMS Personnel

Scope of Practice Approved by State Board of Emergency Medical, Fire and Transportation Services Division of EMS, Ohio Department of Public Safety

CHAPTER 64J-1 Emergency Medical Services

STATUTORY AUTHORITY: KRS 311A.020, 311A.025, 311A.030, 311A.190. NECESSITY, FUNCTION, AND CONFORMITY: KRS 311A.020 requires the board to

Standards for fixed-wing ambulance aircraft and equipment. (a) Each air

E q u i pm e n t f o r A m b u l a n c e s

Target groups: Paramedics, nurses, respiratory therapists, physicians, and others who manage respiratory emergencies.

Occupational Health & Safety. First Aid in Saskatchewan Workplaces

Emergency Medical Services Advanced Level Competency Checklist

(a) A rotor-wing air medical provider that advertises and/or operates in Texas is required to have a valid Texas EMS Provider License.

Title 15 - Mississippi Department of Health. Office of Health Protection. Bureau of Emergency Medical Services

EMS Course Requirements

Airway and Breathing Skills Levels Interpretive Guidelines

PAEMS BLS Non-Transport Supply List (Use in conjunction with IDPH Non-Transport Vehicle Inspection Form)

AMERICAN COLLEGE OF EMERGENCY PHYSICIANS CRUISE SHIP MEDICINE SECTION (CSMS) CRUISE SHIP HEALTHCARE GUIDELINES. January 2013

MEDICAL SUPPORT, TRAINING, AND CASUALTY EVACUATION

Procedure Code A Insulin pen needles A4230 Infusion set for external insulin pump, non needle cannula type A4231 Infusion set for external

Vacuum mattress, Bariatric Transfer, Monitoring Documents Lisa Curatolo / Pete Davis Reviewer Stephen Hearns / Alistair Kennedy

First Responder: The National EMS Scope of Practice changes the name to Emergency Medical Responder.

Minimum Standards for Transport of Critically Ill Patients

Title 15: Mississippi Department of Health. Part 12: Bureau of Emergency Medical Services. Subpart 31: Emergency Medical Services

Frequently Asked Questions About the District of Columbia School Health Nursing Program

CIVIL AVIATION REQUIREMENTS SECTION 2 AIRWORTHINESS SERIES X PART III DATED 12 TH JUNE, 1997 EFFECTIVE: 1 st MARCH 2011

EMERGENCY MEDICAL TECHNICIAN

Neonatal Intubation. Purpose. Scope. Indications. Equipment Cardiorespiratory monitor SaO 2 monitor. Anatomic Considerations.

GWAS Competency Mapping Levels of Medical Support Within GWAS

CITY OF COLORADO SPRINGS TAX GUIDE MEDICAL EXEMPTIONS

Medical Surgical Nursing Skills List

RECERTIFICATION PROTOCOL FOR EMERGENCY MEDICAL SERVICES PERSONNEL MANUAL

CUESTA COLLEGE REGISTERED NURSING PROGRAM CRITICAL ELEMENTS

INFORMATION ON CUSTOMS CLEARANCES FOR TRADERS FOR CLASS A MEDICAL DEVICES EXEMPTED FROM PRODUCT REGISTRATION

State of New Hampshire Department of Safety Division of Fire Standards and Training & Emergency Medical Services

EMS Educational Institution. Certification Renewal Assessment & Site Visit Report

EMERGENCY NURSING SERVICES PROCEDURES A.

Medications or therapeutic solutions may be injected directly into the bloodstream

IAC Ch 132, p (147A) Definitions. For the purpose of these rules, the following definitions shall apply:

EMERGENCY MEDICAL TECHNICIANS REGULATION

National Registry Skill Sheets

MONTGOMERY COUNTY FIRE AND RESCUE SERVICE

MegaCode Kid Advanced ECG Kid

UC Davis Medical Center Emergency Medicine Airway Equipment: Contents, Cleaning and Stocking

VOLUNTARY AMBULANCE INSPECTION PROGRAM SEAL OF EXCELLENCE

THE AIRWAY IN AEROMEDICAL EVACUATION. PBLD (Problem Based Learning Discussion)

Monitoring and Evaluation Tool for Emergency and Essential Surgical Care (Reference: WHO training manual 'Surgical Care at the District Hospital')

TRANSPORT OF CRITICALLY ILL PATIENTS

Gotta- Have- It Chart

BLS TREATMENT GUIDELINES - CARDIAC

Fire Risk Assessment Tool: Instructions for Use

EMERGENCY NURSING SERVICES GUIDELINES

MEDICAL STANDARDS FOR MOUNTAIN RESCUE OPERATIONS USING HELICOPTERS

GUIDELINES FOR TRANSPORT OF CRITICALLY ILL PATIENTS

Transcription:

NCCEP Standards NCCEP Standards for EMS Equipment Performance Standards 2009

. The baseline equipment required in all systems (including Specialty Care Transport Programs) with EMS personnel credentialed at the specified level. S. The equipment required in all Specialty Care Transport Programs (in addition to the baseline equipment required in all EMS Systems). All Air Medical Specialty Care Transport Programs and dedicated Neonatal Transport Programs are required to carry and maintain equipment and medications specific to each mission, as defined by medical control and OEMS approved protocols. O. The equipment, which is optional for any system with EMS personnel, credentialed at the specified level. Ventilation and Airway Equipment ag Valve Mask (adult and child size bag with 4 sizes of masks) ulb Syringe O lind Insertion Airway Device (IAD) with 2 sizes (one adult and one pediatric) 5 5 3 Cricothyroidotomy (Surgical) equipment 3 Endotracheal tubes (ETT)-cuffed in all 10 sizes from 2.5 through 7.0 Capnometry (Color) ETCO2 detectors 4 4 4 Laryngoscope blades in 4 straight sizes 0-4 and 3 curves sizes 2-4 Laryngoscope handle with extra batteries, bulbs McGill forceps or equivalent with 2 sizes (one adult and one pediatric) Meconium Aspirator adaptor Nasal cannula for Oxygen Delivery with 2 sizes (one adult and one pediatric) Nasopharyngeal airways in sizes 14, 18, 20, 22, 24, 26, 28, 30, and 32 O Nebulizer Needle at least 3.25 in. and large bore for Chest Decompression Oropharyngeal airways in 6 sizes 0-5 Oxygen Mask (Non-Rebreathing) in 2 sizes (one adult and one pediatric) Oxygen Tubing Portable Oxygen with variable flow regulator (Portable and Fixed) Rigid pharyngeal suction device Stylettes for every required Endotracheal tube size Suction apparatus (Portable and Fixed) Suction catheters (one between 6 and 10F size, one between 12 and 16F size) O Syringe in 10ml size (non-luerlock) Ventilator (Pressure or Volume based with PEEP)* S, O Wide-bore suction tubing O Monitoring and Defibrillation Automatic External Defibrillator with 2 pad sizes (one adult and one pediatric) O 1 1 O Capnography (ETCO2) monitoring, continuous 7 7 7 Performance Standards (Page 1 of 4) 2009

Glucose Measuring Device 2 Pacemaker- External Pacemaker-Transvenous S Monitor with 12 lead EKG 6 6 6 Monitor/defibrillator with electrodes and 2 sizes of pads or paddles Pulse oximeter with 2 probe sizes (one adult and one pediatric) O 2 Immobilization Devices Cervical spine immobilization device in at least 3 sizes (small, medium, and O, S 1 large) CPR oard Femur traction device in at least 2 sizes (one adult and one pediatric) O, S 1 Head immobilization device O, S 1 ackboards, short and long (Radiolucent preferred) with appropriate O 8 8 8, S 1 restraints (minimum of 3 straps) Spinal immobilization and extrication device O, S 1 Upper and Lower extremity immobilization devices O, S 1 andages urn sheet O Cold packs O Dressings, bandages, gauze rolls, adhesive tape (must have 2 triangular bandages with 2 safety pins each) Heavy scissors for clothing removal Occlusive dressing O Sterile saline solution for irrigation (may use IV solution) O Medication Administration Alcohol wipes O Intraosseous needles in at least 2 sizes (one adult and one pediatric) IV administration sets IV arm boards IV catheters in at least 4 sizes (14, 18, 20, and 24 Gauge) IV pole/hook O O 8 8 Needles in various sizes (at least 1 must be 1.5 in. for IM injections) Syringes in at least 3 sizes (1ml, 5ml, and 10ml) Tourniquet O Obstetrical Thermal blanket capable of also covering the head Sterile O kit, scissors, bulb suction, cord clamps O Miscellaneous edpan and urinal 8 8 8 roselow Tape or equivalent Cellular phone O Emesis basins Lubricating jelly O Gastric tubes in at least 6 sizes (6, 8, 10, 12, 14, and 16F) S, O Sheets, pillows, pillow cases, and towels 8 8 8 Sphygmomanometer (cuffs and device) with at least 3 sizes (pediatric, normal adult, and large adult) Stair chair/folding stretcher O 8 8 8, S 1 Stethoscope Thermometer with low temperature capability O Performance Standards (Page 2 of 4) 2009

Triage tags O, S 1 Wheeled cot with security for patient transport 8 8 8, S 1 Injury Prevention Equipment Appropriate Restraints for Crew and non-patient passengers Fire Extinguisher Flashlight with extra batteries Heat and cooling source for ambulance compartment 8 8 8 8 Thermal blanket or other heat conserving device Infection Control Disinfectant hand wash Disinfectant solution for cleaning equipment Disposable biohazard trash bags Eye protection O Gloves, non-sterile N-95 or HEPA Masks Jumpsuits/gown O Latex Allergy Kit (If not using latex free equipment)**** O Latex Free Gloves Masks Sharps containers (Fixed and Portable) O Shoe covers O Conv. = Convalescent Transport Program, EMT = Emergency Medical Technician, EMT-I = EMT- Intermediate, EMT-P = EMT-Paramedic 1 = Automated External Defibrillators (AED) currently in service may or may not be capable of using pediatric sized pads. As AEDs that are not capable of accepting pediatric pads are retired and replaced, pediatric capable devices should be implemented. 2 = Glucose Measuring Devices and Pulse Oximetry must be available to monitor any patient cared for within an EMT-asic System. This should be monitored by the EMS System Peer Review Process if not required by the EMS System. 3 = All EMT-Paramedic Systems must have an airway backup. This can be a any lind Insertion Airway Device such as the Combitube, King LT, Laryngeal Mask Airway (LMA). It is highly recommended that this airway backup have pediatric sizes. Systems performing Drug Assisted Intubation must also have the ability to perform Surgical Cricothyrotomy. Commercial Cricothyrotomy or Tracheostomy kits that create an airway comparable to a surgical Cricothyrotomy are acceptable. 4 = All EMT-asic, EMT-Intermediate and Paramedic Systems must at a minimum use Capnometry (Color) to confirm the placement of every IAD or intubation. EMT-Paramedic systems performing Drug Assisted Intubation must use Capnography (numeric or waveform) to confirm tube placement. Waveform Capnography is recommended for this requirement. 5 = All EMS System at all levels must have a lind Insertion Airway Device of some type. This could be a Combitube, King LT, or LMA. IAD devices with pediatric sizes are highly recommended. 6 = It is not required but highly recommended that all EMS Systems at all levels work to have 12 lead ECG capability at the scene of every emergent event. 7 = It is not required but highly recommended that all EMS Systems at all levels work to have waveform Capnography capability at the scene of every emergent event. 8 = Equipment which is considered optional (not mandatory) to non-transport EMS vehicles. Performance Standards (Page 3 of 4) 2009

S 1 = Specialty Care Transport Programs are not required to maintain this equipment on every response, but the equipment must be available on a case by case basis dependent on the patient care scenario. All Specialty Care Transport Programs which are listed in a counties primary 911 response plan or provide backup 911 primary response service, are required to maintain the same level of skills, medications and equipment which the county system maintains. *For the purposes of this document, a ventilator is a ventilation device, which attaches to an endotracheal or tracheostomy tube. It is capable of ventilating by a pressure or volume delivery mechanism. It must have adjustments for respiratory rate, volume/pressure settings, and for assisted or full ventilation. It has the capabilities of PEEP or other pressure based manipulations. A respirator is any other device that assists with ventilations during a respiratory/cardiac arrest. **All EMS Systems must carry at a minimum the equipment associated with the EMT Level unless functioning as a convalescent transport service. **All EMS Systems must carry pediatric and adult when size is important. Items that require pediatric sizes are shaded ORANGE. ****A Latex Allergy Kit should be composed of all the necessary personal protection equipment and materials necessary to obtain and maintain IV access. Performance Standards (Page 4 of 4) 2009