INSTRUCTIONS FOR USING THE KNEE SOCIETY RADIOGRAPHIC EVALUATION FORM



Similar documents
High-Flex Solutions for the MIS Era. Zimmer Unicompartmental High Flex Knee System

Malrotation Causing Patellofemoral Complications After Total Knee Arthroplasty

THE MEASUREMENT AND ANALYSIS OF AXIAL DEFORMITY AT THE KNEE

Posterior Referencing. Surgical Technique

Zimmer Persona Adverse Events Reported to FDA Through 3/27/2015

for Image Scaling Enabling Digital Orthopaedics

The patellofemoral joint and the total knee replacement

Rotational alignment of the femoral component in total knee arthroplasty

Zimmer FuZion Instruments. Surgical Technique (Beta Version)

Patellofemoral Joint: Superior Glide of the Patella

The Influence of Iliotibial Tract on Patellar Tracking

Medial patellofemoral ligament reconstruction for patellar maltracking following total knee arthroplasty is effective

NEXGEN COMPLETE KNEE SOLUTION. Epicondylar Instrumentation Surgical Technique For Legacy Posterior Stabilized Knees

Zimmer Gender Solutions NexGen High-Flex Implants

Patellofemoral Chondrosis

Knee Kinematics and Kinetics

Zimmer NexGen CR-Flex and LPS-Flex Knees. Surgical Technique with Posterior Referencing Instrumentation

Structure & Function of the Knee. One of the most complex simple structures in the human body. The middle child of the lower extremity.

Malleolar fractures Anna Ekman, Lena Brauer

VEGA System. PS Knee Replacement Technology. Aesculap Orthopaedics

Evaluate the hindfoot alignment after total knee arthroplasty; new radiographic view of the hindfoot.

SALVATION. Fusion Bolts and Beams SURGICAL TECHNIQUE

Anatomic Percutaneous Ankle Reconstruction of Lateral Ligaments (A Percutaneous Anti ROLL)

Zimmer MOST Options System

Total Knee Replacement Specifications 2014 (01/01/2012 to 12/31/2012 Dates of Procedure)

FEMORAL NECK FRACTURE FOLLOWING TOTAL KNEE REPLACEMENT

BONE PRESERVATION STEM

Custom Design of Knee Joint Prosthesis By Using Computerized Tomography (CT) Images and 3D Modelling

How To Perform An Elbow Operation

Zimmer M/L Taper Hip Prosthesis. Surgical Technique

How To Treat A Patella Dislocation

Trabecular Metal Femoral Component. Surgical Technique

Zimmer NexGen LCCK. Surgical Technique for use with LCCK 4-in-1 Instrumentation. Contact your Zimmer representative or visit us at

VERSYS HERITAGE CDH HIP PROSTHESIS. Surgical Technique for CDH Hip Arthroplasty

Terminology of Human Walking From North American Society for Gait and Human Movement 1993 and AAOP Gait Society 1994

MOST Operations Manual page 1 KNEE AND FULL LIMB RADIOGRAPHY

INTUITION INSTRUMENTS SURGICAL TECHNIQUE

Zimmer Periarticular Proximal Tibial Locking Plate

NexGen Complete Knee Solution Intramedullary Instrumentation Surgical Technique

Oxford Partial Knee. A Definitive Implant. Tibial Component. Anatomical shape for optimal bone coverage

Oftentimes, as implant surgeons, we are

Surgical procedure. METS Modular Distal Femur


Your Practice Online

Scorpio NRG CR & PS. Single Radius Primary Knee System Surgical Protocol. Anterior Referencing

Know-how brings motion back to life. SM. Solution UC-PLUS. Unicompartmental Knee Prosthesis. Surgical Technique

Restoration Modular Cone Body/Conical Distal Stem Femoral Components Using the Restoration Modular Instrument System Surgical Technique

Temporomandibular Joint Imaging Using CBCT: Technology Now Captures Reality!

Basic Radiographic Procedures

Synopsis of Causation

To access the Podiatry tools; open a Patient Study, left click on 2020 logo at the top left which

DIAGNOSING SCAPHOID FRACTURES. Anthony Hewitt

Osteotomy for medial compartment arthritis of the knee using a closing wedge or an opening wedge controlled by a Puddu plate

Spinal Arthrodesis Group Exercises

Biomechanics of Knee Replacement. Ryan Keyfitz Rohinton Richard


Total Knee Arthroplasty Rehabilitation

Cervical Spondylotic Myelopathy Associated with Kyphosis or Sagittal Sigmoid Alignment: Outcome after Anterior or Posterior Decompression

DRAFTING MANUAL. Gears (Bevel and Hypoid) Drafting Practice

Restoration Modular. Revision Hip System Surgical Protocol

Kinematic Alignment in Total Knee Arthroplasty

The information contained in this document is intended for healthcare professionals only.

FUSEFORCE. Hand Fixation System SURGIC A L T ECHNIQUE

it s time for rubber to meet the road

Zimmer Segmental System. Distal Femoral Surgical Technique

Surgical Technique and Reference Guide

Primary V40 Surgical Protocol. Exeter. total hip system

Making Better Medical Devices with Multisensor Metrology

CHAPTER 5 QC Test For Radiographic Equipment. Prepared by:- Kamarul Amin bin Abu Bakar School of Medical Imaging KLMUC

Product overview and surgical technique

Get-Snap. Once you have installed the DataCAD 9.03 update, you are ready to take advantage of this new feature.

Radiographic Grid. Principles of Imaging Science II (RAD 120) Image-Forming X-Rays. Radiographic Grids

Solving Simultaneous Equations and Matrices

The University of the State of New York REGENTS HIGH SCHOOL EXAMINATION GEOMETRY. Tuesday, August 13, :30 to 11:30 a.m., only.

Scorpio Total Stabiliser Revision Knee System. Surgical Protocol

Versa-Fx II Femoral Fixation System Surgical Techniques

Zimmer M/L Taper Hip Prosthesis with Kinectiv Technology. Surgical Technique

Wednesday 15 January 2014 Morning Time: 2 hours

The University of the State of New York REGENTS HIGH SCHOOL EXAMINATION GEOMETRY. Wednesday, January 28, :15 a.m. to 12:15 p.m.

Total hip arthroplasty (THA) through the anterior approach

Exeter X3 RimFit. Acetabular Cup Surgical Protocol

Structure and Function of the Hip

Structural Integrity Analysis

Corporate Medical Policy Computer Assisted Surgical Navigational Orthopedic Procedures

ROTATING PLATFORM TOTAL KNEE REPLACEMENT BRIGHAM AND WOMEN S HOSPITAL, BOSTON, MA Broadcast May 20, 2004

Lower Extremity Orthopedic Surgery in Cerebral Palsy. Hank Chambers, MD Rady Children s Hospital - San Diego

ORTHOPAEDIC SURGERY FOR THE LOWER LIMBS IN CHILDREN WITH CEREBRAL PALSY

The University of the State of New York REGENTS HIGH SCHOOL EXAMINATION GEOMETRY. Student Name:

S-ROM NOILES. This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE

Rear Impact Guard TEST METHOD 223. Standards and Regulations Division. Issued: December 2003

Dip is the vertical angle perpendicular to strike between the imaginary horizontal plane and the inclined planar geological feature.

PRIMARY KNEE SYSTEM SIGMA SURGICAL TECHNIQUE. Balanced Surgical Technique INSTRUMENTS

Zimmer PSI Knee System For Use with Persona The Personalized Knee System Surgical Technique

Transcription:

INSTRUCTIONS FOR USING THE KNEE SOCIETY RADIOGRAPHIC EVALUATION FORM Routine standing and recumbent anterior-posterior, lateral, and skyline patellar roentgenograms are made pre-operative, at time of hospital discharge post-operative, and at each follow-up visit. The skyline patellar views use the technique suggested by Laurin et al (3) except the knees are flexed 60 degrees instead of twenty to thirty degrees as recommended by Laurin. This radiographic positioning is similar to the technique described by Merchant et al (4) except the radiographic beam is directed cephalad instead of towards the foot. In addition the knee may be more flexed (45-60 degrees) compared to forty-five degrees recommended by Merchant. In both the Laurin and Merchant views the radiographic beam is perpendicular to the radiographic cassette. Three foot long cassette roentgenograms at a six foot tube to film distance with the patient standing are not routinely made except when unusual deformity or special knee alignment problems are anticipated. Roentgenographic data is recorded using the Knee Society total knee evaluation and scoring system (1) pre-operatively and postoperatively on the latest set of films made for each knee. All linear measurements are made with a 15% magnification ruler in millimeters. Angle measurements were recorded in degrees. Additional radiographic measurements using the general systems of Gomes et al (2) and Laurin et al (3) are made of the patella in the skyline views pre-operative and post-operatively. These measurements are patellar thickness, width, tilt, medial-lateral displacement, and the angle of the patellar prosthesis in patellar bone.

Figure 1a shows the patellar tilt angle ( ) for the unsurfaced patella, pre and post-operative using the evaluation system of Laurin et al (3). The patellar tilt angle for the pre-operative or unsurfaced patella is formed by a line drawn across the anterior limits of the femoral condyle or prosthesis in the skyline view and a line connecting the apex of the patellar articular surface (point where medial and lateral patellar facets join) with the lateral edge of the lateral patellar facet. If the angle is positive as indicated in the drawing, the patellar angle is considered normal. If the angle is zero or reversed, patellar tilt is considered abnormal. Subluxation and dislocation are also indicated by this measurement, because a low or reversed angle indicates subluxation and displacement. If the reversed angle is high, complete dislocation will be present.

Figure 1b measures patellar thickness (T) pre and post-operatively as the vertical distance from the anterior cortex of the patella to the depth of the femoral patellar sulcus. Patellar tilt ( ) after a patellar prosthesis has been implanted is the angle between a line drawn connecting the anterior limits of the condyles and a line drawn through the prosthesis bone-interface. Figure 1c measures the patellar prosthesis-bone angle ( ) at the intersection of a line drawn through the equator of the patellar bony remnant and a line drawn through the patellar prosthesis-bone interface. Figure 1d measures the medial-lateral position of the bony patella pre and post-operative and the prosthesis-bone complex post-operative patellar replacement. This measurement is the horizontal distance between two vertical lines perpendicular to a line drawn across the femoral condyles. One line is formed by the midpoint of the bony patella and the other line by a point in the depth of the femoral patellar sulcus. The later point can be estimated by visual inspection or by the intersection of the medial and lateral tangent lines of the femoral condyles converging in the depths of the sulcus.

Figure 2a measures the position of the joint line by the shortest distance on a recumbent anterior-posterior film between the tip of the fibula and a line drawn between the two subchondral plates of the femoral condyles pre-operative and postoperatively using the femoral metal component. Figure 2b measures the position of the patellar prosthesis in the superior-inferior direction post-operative. This measurement is made between the most inferior bony point of the patella and a horizontal line from the distal point of the articular surface pre-operatively and the most distal point of the patellar prosthesis post-operatively. The distal point of the replaced patella is identified by the cement margin or in some cases by the outline of the polyethylene patellar prosthesis. REFERENCES: 1. Ewald, FC: The Knee Society total knee arthroplasty roentgenographic evaluation and scoring system. Clin Orthop 248:9-12, 1989.

2. Gomes LS. Bechtold JE, Gustilo RB: Patellar prosthesis positioning in total knee arthroplasty; A roentgenographic study. Clin Orthop 236:72-81, 1988. 3. Laurin CA, Levesque HP, Dussault R, Labelle H, Peides JP: The abnormal lateral patellofemoral angle. J Bone and Joint Surg 60- A:55-60, 1978. 4. Merchant AC, Mercer RL, Jacobsen RH, Coal CR: Roentgenographic analysis of patellofemoral congruence. J Bone Joint Surg 56-A:1391-1396, l974.