ATL Fuel Level Sender Probes



Similar documents
PART 1 - INTRODUCTION...

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Electronic Pressure Switch EDS 300

TS1 Ultra Sonic Tank Sender Training. 27 November 2007

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Electronic Pressure Switch EDS 3000

Givare NC-SRS 280 och 880

Toroidal Conductivity Sensor

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

HF series Hall effect joysticks

Contents. Document information

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Drayton Digistat +2RF/+3RF

PMP 4000 Series. Druck Amplified Output Pressure Transducers. GE Sensing. Applications. Features

Cable Plug acc. to DIN EN , Form A

Series 510 Submersible Level Transmitters

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

CONTOIL DFM 8EDM. Table of contents. Mounting and operating instructions

Series 6000 Torque measured metal bellow coupling

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Series 7500 Torque Sensor

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Water Leak Detection System

Pressure transmitter For general industrial applications Model A-10

Technical data sheet TDS0070

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

Digital inductive conductivity transmitter

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

ALARMLINE ANALOGUE Linear Heat Detection System

Duct Humidity Transmitter

User s Manual. BNC Mini-High Res, 75 Ohm Termination Kit Connector Installation Guide ( )

Model 201 Wiegand Touchpad Reader Installation Guide

ENAiKOON ultrasonic fuel-level sensor

Telefon (+45) Telefax (+45) Installation and operating manual

HYDRA HV OPERATION MANUAL. 2.0 Making Connections on your HYDRA speed control. Rosin core electrical solder

i ChatterBox! Motorcycle Security

Global Water Instrumentation, Inc.

1993 ACCESSORIES & EQUIPMENT Volkswagen Instrument Panels. Volkswagen; EuroVan, Passat

AUTOMOTIVE LED LIGHT CATALOG

MTB Load Cell. Globally Approved for Accuracy and Safety. MTB Load Cell

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Absolute Rotary Encoder E6CP

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Instruction Manual. T3111 T3111L T3111P T3111Ex

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Manual Ranging MultiMeter

Hand-held thermometer Model CTH7000

SELECTION, APPLICATION AND MAINTENANCE

How To Read A Pipe From A Sensor

tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable

EN 3 ABSORPTION, READY TO USE ANALYSE BULK DESULPHATION SOFT START. L: 2000 mm MODE- BUTTON SUPPLY PLUG* SUPPLY

FLR 1000 & 1000-BR Series Flow Sensors & Meters For Gases

Proportional pressure regulators VPPE

Shunt lock function 3066

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34

IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

Compact Sensors - S8 Series. Compact size and high performance for the most challenging detection applications

TECHNICAL DATASHEET Incremental Encoder RI 58-O / RI 58-T

SX460. Generator Automatic Voltage Regulator Operation Manual

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Malibu Monte Carlo El Camino

2 & 5-Wire Overfill Sensors

LENORD. +BAUER... automates motion. PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space

OLI. Oil level indicator

Mounting Instructions. Torque Transducer. A en

Digital Ground Resistance Tester. Models 4620 & Digital Ground Resistance Tester

Models SFP33 & SFP32 Pressure Transmitters

MOUNTING AND OPERATING INSTRUCTIONS

MAGTROL. ZS Series Load Cell. ZS Data Sheet. Features. Description

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

G-100/200 Operation & Installation

SYMMETRIC 1A POWER SUPPLY K8042

GREISINGER electronic GmbH

TMS TANK MANAGEMENT SYSTEM

Charge Regulator SCR 12 Marine

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

Part I - Installation

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Turbine Flow Sensor Series VTR

VOYAGER 570G. 744A Sprayer Control

Technical Update TAA.TU Rev. 1

A99B Series Temperature Sensors

MANUAL EN 3 SUPPLY PLUG* MAINS CABLE CTEK COMFORT CONNECT ABSORPTION, READY TO USE ANALYSE FLOAT, FULLY CHARGED PULSE, MAINTENANCE CHARGING

Liquid Level Limit Switch liquiphant T FTL 20

Heating oven with mechanical convection

Bathroom Cabinet. Installation & User Guide. Illuminated Mirrors.

Transcription:

T E C H N I C A L S P E C I F I C A T I O N The ATL EL-AD-151 (Resistance Output) and EL-AD-152 (Voltage Output) Fuel Level Senders are highly advanced sensors for continuously measuring the contents of a fuel tank. These sensors are both adjustable and can be cut to length (between 540mm and 200mm). A low level alarm switches when the fuel drops below a predetermined level (default is 1/8th of the tank), but the alarm point can be optionally specified anywhere between 0-100%. Dimensions: Probe length: 540mm Note: The probe length should leave min. 16mm from the end of the probe to the base of the tank. The probe shaft cannot be cut shorter than 200mm. Electrical: Supply voltage: 12 or 24Vdc nominal* Supply current: 28mA@12Vdc + output load Connections: 500mm long flying leads which can be Accuracy: ±2.0% of depth @ 20ºC (+68ºF) optionally fitted with any specified receptacle *Protected against overvoltage (80Vdc for 2 minutes) and incorrect electrical connection Outputs: Resistive (EL-AD-151): 240Ω (Empty) to 33Ω (Full). Not suitable for constant current application. Voltage (EL-AD-152): Alarm: Warning Output Load: 0-5V [Note: V out is protected from damage if misconnected to V+ (>32V) or Gnd.] Switch to ground at 1/8 tank depth - max load 100mA - optionally adjustable between Empty and Full. 100mA max. Construction: Housing: 30% glass filled Nylon 66 Internal sensor: Aluminium Sensor tube: Stainless steel 316 Wetted seals: PTFE & Nitrile Internal insulators: Fluid Types: PTFE Only suitable for EU standard pump fuel (diesel and petrol). Environmental Ratings: Temperature - operating: -40ºC to +85ºC (-4ºF to +185ºF) Sealing: IP67 - storage: -40ºC to +105ºC (-40ºF to +221ºF) Shock: 50g 6.3mS Max tank pressure: For use in unpressurised tanks Weight: 300g (10 oz) (1M long unit) Vibration: BS EN 60068-2-64:1993 (15.3grms) EMC: Type approval in accordance with EN ISO 13766:2006 Wire colour codes: Red: V+ (9 ~ 34V) Green: V- (Ground) Yellow: LLA max 100mA Blue: Signal out (V) Black: Signal out (O) White: Calibration Issue Date: 11/01/2012 Page 1 of 6 Approval:

LEVEL PROBE CUTTING, WIRING & CALIBRATION INSTRUCTIONS Before starting this procedure, please ensure that the correct ATL Fuel Level Probe is being used with the correct Dashboard Gauge/Data Logger. Note: ATL Dashboard Gauge EL-AD-068 only works with Fuel Level Probe EL-AD-151 (Resistive 240-33 Ohms Output). For customers using the Fuel Level Probe EL-AD-152 (Voltage 0-5V Output), these will only work with a Data-Logger. Stage 1) Stage 2) Stage 3) Cutting Instructions Wiring Instructions Calibration Instructions Stage 1: Cutting Instructions 1. Measure the depth of your fuel cell from the inside bottom face to top of mounting plate, where the Header will be positioned. 2. Measure length of probe (from the DATUM POINT), mark this distance on the probe shaft and deduct 16mm. The 16mm reduction in length allows clearance between the probe shaft and the bottom of the tank. Note: Please do not cut shaft to less than 200mm 3. Using soft jaws, place probe in vice and gently grip the sensor shaft. Note: Do not crush the sensor shaft in vice as this is just to support the shaft from turning when trimming to length. Issue Date: 11/01/2012 Page 2 of 6 Approval:

4. Using a tube cutter, cut the steel tube at the point marked at point (2). Note: When using the cutting tool, adjust cutting blade slowly to prevent the outer tube being crushed. 5. Once cut, use a twisting action, to free the centre rod from its end plug, carefully remove and discard the excess tube length. 6. Measure and mark the length of the centre aluminium rod, 1 to 2 mm longer than the steel outer tube. 7. Using a fine toothed hacksaw carefully cut the centre aluminium rod. Please ensure that this inner rod does NOT rotate as this could damage the Sender unit beyond repair. 8. De-burr the cut edge of outer tube and centre rod. 9. To ensure that the centre rod is located centrally in the outer tube insert the white PTFE insert. Issue Date: 11/01/2012 Page 3 of 6 Approval:

10. Fit the special black end plug to the end of the outer tube. This end plug is designed to be an interference fit and no mechanical fixing is required. Stage 2: Wiring Information: Please check wire colours according to choice of Fuel Level Sender Probe EL-AD-151 (Resistance 240-33 Ω) EL-AD-152 (Voltage 0-5V) Red: V+ (9 ~ 34V) Red: V+ (9 ~ 34V) Green: V- (Ground) Green: V- (Ground) Yellow: LLA max 100mA Yellow: LLA max 100mA Black: Signal out (Ohm) Blue: Signal out (V) White: Calibration White: Calibration IMPORTANT: PLEASE ENSURE THAT VEHICLE HAS A NEGATIVE EARTH SYSTEM. Issue Date: 11/01/2012 Page 4 of 6 Approval:

Stage 3: Calibration Instructions 1. With the probe out of the Fuel Cell, wire up the Fuel Level Sender Probe to the ATL Dashboard, or Data Logger, as per the wiring diagram (Page 4). Connect the calibration wire (white) to ground, or onto the shaft of the Sensor Probe, and then power up the Sender with a 12V supply. Disconnect the calibration wire (white) after 10 seconds, but keep the Sender connected to the 12V supply. This has calibrated the Zero (Empty) point of the Sender output. Note: If using a Dashboard Gauge, this will stay on Full. Please ensure that a 12V supply is connected at all times during calibration. 2. Insert the Fuel Level Probe into the Fuel Cell and refuel the cell until the fuel level reaches above the Full Level hole in shaft (see diagram). 3. Touch the calibration wire (white) to ground for 10 seconds and then remove it. This has calibrated the Full point of the Sender output. Notes: After calibration, the sender can be manually raised and lowered, in and out of the fuel cell so that the fuel level output can be observed on the Gauge or Data Logger. Issue Date: 11/01/2012 Page 5 of 6 Approval:

Troubleshooting Questions 1. Is the correct sender being used for the application? EL-AD-151 gives a resistance output EL-AD-152 gives a voltage output 2. Is the correct probe being used with the gauge? Gauge EL-AD-068 only works with Probe EL-AD-151 3. Are the vehicle electrics negative earth? Sender probe only works with negative earth. 4. Is the power supply 12 volts, as per instructions? 5. Has the probe been cut to correct length? Sender probe must only be cut as per the instructions. Take care not to bend or damage the central element when cutting to length. Care must be taken when fitting the plastic centre into tube. The inner tube must NOT touch the outer tube. 6. Was the foot fitted leaving clearance to the base of the cell? If the sender foot is trapped when it is bolted in (i.e. it is too long) then it is unlikely to read the fuel level unless full. It may also read full as the level drops (as fuel is trapped in the tube). 7. When fitting the plastic spacer (after cutting the tube to length), please ensure that it does not form a seal against the foot as the foot is fitted to the outer tube. Ensure it is a minimum of 10mm from the end of the tube. 8. Does the installer have the instruction sheets? 9. Is the probe being immersed in the fuel that will be used? Please note that due to differing dielectric constants, the Fuel Level Probe must be re-calibrated each time a different fuel is used (e.g. race or road). 10. Has the wiring diagram been followed as per instructions? 11. Is the number on the shaft of the probe correct? 12. When calculating low and high settings the time delay should be between 3 and 10 seconds. 13. Once the system has been correctly set up, the temperature of the fuel during use may affect the reading at the gauge. 14. If the sender has been cut to length, both low and full settings will have to be re-calibrated. This is because the default factory settings are for the manufactured length not the cut length. Issue Date: 11/01/2012 Page 6 of 6 Approval: